Exploring the structural changes on excitation of a luminescent organic bromine-substituted complex by in-house time-resolved pump-probe diffraction

The structural changes accompanying the excitation of the luminescent dibromobenzene derivative, 1,4-dibromo-2,5-bis(octyloxy)benzene, have been measured by in-house monochromatic time-resolved (TR) diffraction at 90 K. Results show an increment of the very short intermolecular Br•••Br contact distance from 3.290 Å to 3.380 Å. These calculations show the Br…Br interaction to be strongly repulsive in both the Ground and Excited states but significantly relaxed by the lengthening of the contact distance on excitation. The stability of the crystals is attributed to the many weak C-H···Br and C-H···π intermolecular interactions. Our study described is the first practical application of In-House Time-Resolved diffraction, made possible by the continuing increase in the brightness of X-ray sources and the sensitivity of our detectors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monitoring molecular nonadiabatic dynamics with femtosecond X-ray diffraction

Significance X-ray crystallography has long been used to determine the structure of crystals and molecular samples. More recent advancements in light sources and computational methods made it possible to routinely determine the structure of large proteins. The introduction of X-ray free-electron lasers opens up the possibility to track the dynamics of molecular structures on a femtosecond time scale and to create molecular movies of chemical reactions. The theory of time-independent diffraction is well known. However, time-resolved diffraction techniques pose not only new challenges to experiments but also to their interpretation. In this work, we present a unified theoretical framework that will aid experimental interpretations as well as predictions of types of X-ray diffraction experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bandgap modulation in photoexcited topological insulator Bi{sub 2}Te{sub 3} via atomic displacements

The atomic and electronic dynamics in the topological insulator (TI) Bi{sub 2}Te{sub 3} under strong photoexcitation were characterized with time-resolved electron diffraction and time-resolved mid-infrared spectroscopy. Three-dimensional TIs characterized as bulk insulators with an electronic conduction surface band have shown a variety of exotic responses in terms of electronic transport when observed under conditions of applied pressure, magnetic field, or circularly polarized light. However, the atomic motions and their correlation between electronic systems in TIs under strong photoexcitation have not been explored. The artificial and transient modification of the electronic structures in TIs via photoinduced atomic motions represents a novel mechanism for providing a comparable level of bandgap control. The results of time-domain crystallography indicate that photoexcitation induces two-step atomic motions: first bismuth and then tellurium center-symmetric displacements. These atomic motions in Bi{sub 2}Te{sub 3} trigger 10% bulk bandgap narrowing, which is consistent with the time-resolved mid-infrared spectroscopy results.

36 MATERIALS SCIENCE↗

Neutron diffraction measurements of time-dependent residual stresses generated by severe thermomechanical deformation

Residual stresses were generated by severe thermomechanical deformation in an aluminum alloy plate. The evolution of the residual stresses during natural aging was investigated by neutron diffraction up to 10,000h. A data reduction method was developed to eliminate microstructure influences (solute variations) on the lattice spacing changes, thereby allowing the determination of the long-range macroscopic residual stresses. The residual stress decreased ({approx}25MPa) with time due to the microstructural modification within the deformed region during natural aging.

36 MATERIALS SCIENCE↗

Asymmetric band flipping for time-of-flight neutron diffraction data

Charge flipping with powder diffraction data is known to produce a result more reliably with high-resolution data, i.e. visible reflections at small d spacings. This data are readily accessible with the neutron time-of-flight technique but the assumption that negative scattering density is nonphysical is no longer valid where elements with negative scattering lengths are present. The concept of band flipping was introduced in the literature, where a negative threshold is used in addition to a positive threshold during the flipping. But, it was not tested with experimental data at the time. Finallly, band flipping has been implemented in TOPAS together with the band modification of low-density elimination and tested with experimental powder and Laue single-crystal neutron data.

36 MATERIALS SCIENCE↗

Experimental determination of precision, resolution, accuracy and trueness of time-of-flight neutron diffraction strain measurements

We discuss a simple statistical analysis which yields the precision, resolution, accuracy and trueness of diffraction-based lattice strain measurements. The procedure consists of measuring the thermal expansion induced in each component of an ideal, non-reacting, two-component, crystalline powder sample in situ. One component, with a high coefficient of thermal expansion (CTE), serves as an internal thermometer. The quantities of interest are obtained by determining the smallest, statistically significant, thermal lattice strain which can be detected through diffraction analysis in the second, low CTE, component in response to controlled temperature changes. This procedure also provides a robust check of the alignment of the diffraction system and is able to reveal the presence of systematic errors. The application of this technique to a time-of-flight engineering diffractometer/strain scanner is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Expanding Lorentz and spectrum corrections to large volumes of reciprocal space for single-crystal time-of-flight neutron diffraction

Evidence is mounting that potentially exploitable properties of technologically and chemically interesting crystalline materials are often attributable to local structure effects, which can be observed as modulated diffuse scattering (mDS) next to Bragg diffraction (BD). BD forms a regular sparse grid of intense discrete points in reciprocal space. Traditionally, the intensity of each Bragg peak is extracted by integration of each individual reflection first, followed by application of the required corrections. In contrast, mDS is weak and covers expansive volumes of reciprocal space close to, or between, Bragg reflections. For a representative measurement of the diffuse scattering, multiple sample orientations are generally required, where many points in reciprocal space are measured multiple times and the resulting data are combined. The common post-integration data reduction method is not optimal with regard to counting statistics. A general and inclusive data processing method is needed. In this contribution, a comprehensive data analysis approach is introduced to correct and merge the full volume of scattering data in a single step, while correctly accounting for the statistical weight of the individual measurements. Development of this new approach required the exploration of a data treatment and correction protocol that includes the entire collected reciprocal space volume, using neutron time-of-flight or wavelength-resolved data collected at TOPAZ at the Spallation Neutron Source at Oak Ridge National Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time resolved X-ray diffraction using the FIDDLE diagnostic at NIF: Preliminary assessment of diffraction precision

The Flexible Imaging Diffraction Diagnostic for Laser Experiments (FIDDLE) is a new diagnostic at the National Ignition Facility (NIF) designed to observe in situ solid-solid phase changes at high pressures using time resolved X-ray diffraction. FIDDLE currently incorporates five Icarus Ultrafast X-ray Imager sensors that take 2 ns snapshots and can be tuned to collect X-rays for tens of ns. The platform utilizes the laser power at NIF for both the laser drive and the generation of 10 keV X-rays for ~10 ns using a Ge backlighter foil. We aim to use FIDDLE to observe diffraction at different times during compression to probe the kinetics of phase changes. Pb undergoes two solid-solid phase transitions during ramp compression: from FCC to HCP and HCP to BCC. Results will be reported on some of the first shots using the FIDDLE diagnostic at NIF on ramp compressed Pb to a peak pressure of ~110 GPa and a single undriven CeO2 calibration shot. A discussion of the uncertainties in the observed diffraction is included.

Vennari, C. E.↗

Real-time synchrotoron radiation X-ray diffraction and abnormal temperature dependence of photoluminescence from erbium silicates on SiO{sub 2}/Si substrates

The erbium silicate formation processes during annealing in Ar gas were monitored by synchrotron radiation grazing incidence X-ray diffraction (GIXD) in real time and the optical properties of the silicates were investigated by photoluminescence measurements in spectral and time-resolved domains. The GIXD measurements show that erbium silicates and erbium oxide are formed by interface reactions between silicon oxide and erbium oxides deposited on silicon oxide by reactive sputtering in Ar gas and O{sub 2}/Ar mixture gas ambiences. The erbium silicates are formed above 1060 degree sign C in Ar gas ambience and above 1010 degree sign C in O{sub 2}/Ar gas ambience, and erbium silicides are dominantly formed above 1250 degree sign C. The I{sub 15/2}-I{sub 13/2} Er{sup 3+} photoluminescence from the erbium oxide and erbium silicate exhibits abnormal temperature dependence, which can be explained by the phonon-assisted resonant absorption of the 532-nm excitation photons into the {sup 2}H{sub 11/2} levels of Er{sup 3+} ions of the erbium compounds.

36 MATERIALS SCIENCE↗

Electrical design of the flexible imaging diffraction diagnostic for laser experiments (FIDDLE) at the National Ignition Facility (NIF)—Requirements, design, and performance

The Flexible Imaging Diffraction Diagnostic for Laser Experiments (FIDDLE) is a newly developed diagnostic for imaging time resolved diffraction in experiments at the National Ignition Facility (NIF). It builds on the successes of its predecessor, the Gated Diffraction Development Diagnostic (G3D). The FIDDLE was designed to support eight Daedalus version 2 sensors (six more hCMOS sensors than any other hCMOS-based diagnostic in NIF to date) and an integrated streak camera. We will review the electrical requirements, design, and performance of the electrical subsystems that were created to support this large number of cameras in the FIDDLE. The analysis of the data that the FIDDLE is intended to collect relies heavily on the accurate and well-understood timing of each sensor. We report camera-to-camera timing jitter of less than 100 ps rms and sensor integration times of 2.2 ns FWHM in 2-2 timing mode. Additionally, diffraction experiments on the NIF produce electric fields (EMI) on the order of 1 kV/m, which have been observed to negatively impact the performance of some electrical components of the FIDDLE. We report on the results of testing hCMOS camera electronics in a similar EMI environment generated in an offline lab. In addition, we also summarize the use of a novel approach to using a vector network analyzer as an EMI leak detector to understand and reduce the negative impacts of EMI on the FIDDLE.

47 OTHER INSTRUMENTATION↗

Kinetic Analysis of Cation Exchange in Birnessite using Time-resolved Synchrotron X-ray Diffraction

In this study, we applied time-resolved synchrotron X-ray diffraction (TRXRD) to develop kinetic models that test a proposed two-stage reaction pathway for cation exchange in birnessite. These represent the first rate equations calculated for cation exchange in layered manganates. Our previous work has shown that the substitution of K, Cs, and Ba for interlayer Na in synthetic triclinic birnessite induces measurable changes in unit-cell parameters. New kinetic modeling of this crystallographic data supports our previously postulated two-stage reaction pathway for cation exchange, and we can correlate the kinetic steps with changes in crystal structure. In addition, the initial rates of cation exchange, R ({angstrom}{sup 3} min{sup -1}), were determined from changes in unit-cell volume to follow these rate laws: R = 1.75[K{sup +}{sub (aq)}]{sup 0.56}, R = 41.1[Cs{sup +}{sub (aq)}]{sup 1.10}, R = 1.15[Ba{sup 2+}{sub (aq)}]{sup 0.50}. Thus, the exchange rates for Na in triclinic birnessite decreased in the order: Cs >> K > Ba. These results are likely a function of hydration energy differences of the cations and the preference of the solution phase for the more readily hydrated cation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-domain model of gyroklystrons with diffraction power input and output

A time-domain theory of gyroklystrons with diffraction input and output has been developed. The theory is based on the description of the wave excitation and propagation by a parabolic equation. The results of the simulations are in good agreement with the experimental studies of two-cavity gyroklystrons operating at the first and second cyclotron harmonics. Along with the basic characteristics of the amplification regimes, such as the gain and efficiency, the developed method makes it possible to define the conditions of spurious self-excitation and frequency-locking by an external signal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-resolved x-ray diffraction techniques for bulk polycrystalline materials under dynamic loading

We have developed two techniques for time-resolved x-ray diffraction from bulk polycrystalline materials during dynamic loading. In the first technique, we synchronize a fast detector with loading of samples at strain rates of ∼10{sup 3}–10{sup 4} s{sup −1} in a compression Kolsky bar (split Hopkinson pressure bar) apparatus to obtain in situ diffraction patterns with exposures as short as 70 ns. This approach employs moderate x-ray energies (10–20 keV) and is well suited to weakly absorbing materials such as magnesium alloys. The second technique is useful for more strongly absorbing materials, and uses high-energy x-rays (86 keV) and a fast shutter synchronized with the Kolsky bar to produce short (∼40 μs) pulses timed with the arrival of the strain pulse at the specimen, recording the diffraction pattern on a large-format amorphous silicon detector. For both techniques we present sample data demonstrating the ability of these techniques to characterize elastic strains and polycrystalline texture as a function of time during high-rate deformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Few-femtosecond resolved imaging of laser-driven nanoplasma expansion

Abstract The free expansion of a planar plasma surface is a fundamental non-equilibrium process relevant for various fields but as-yet experimentally still difficult to capture. The significance of the associated spatiotemporal plasma motion ranges from astrophysics and controlled fusion to laser machining, surface high-harmonic generation, plasma mirrors, and laser-driven particle acceleration. Here, we show that x-ray coherent diffractive imaging can surpass existing approaches and enables the quantitative real-time analysis of the sudden free expansion of laser-heated nanoplasmas. For laser-ionized SiO 2 nanospheres, we resolve the formation of the emerging nearly self-similar plasma profile evolution and expose the so far inaccessible shell-wise expansion dynamics including the associated startup delay and rarefaction front velocity. Our results establish time-resolved diffractive imaging as an accurate quantitative diagnostic platform for tracing and characterizing plasma expansion and indicate the possibility to resolve various laser-driven processes including shock formation and wave-breaking phenomena with unprecedented resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal transport in thin films measured by time-resolved, grazing incidence x-ray diffraction.

We use depth- and time-resolved x-ray diffraction to study thermal transport across single crystal Bi films grown on sapphire in order to determine the thermal conductivity of the film and the Kapitza conductance of the interface. Ultrafast Ti:sapphire laser pulses were used to heat the films; x-ray diffraction then measured the film's lattice expansion. Use of grazing incidence diffraction geometry provided depth sensitivity, as the x-ray angle of incidence was varied near the critical angle. The shift of the film's Bragg peak position with time was used to determine the film temperature averaged over an x-ray penetration depth that could be selected by choice of the angle of incidence. For films that were thick compared to the laser penetration depth, we observed a large temperature gradient at early times. In this case, measurements with the incident angle near or well above the critical angle were more sensitive to the film conductivity or Kapitza conductance, respectively. For thinner films, however, cooling was dominated by the Kapitza conductance at all accessible time scales.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Structural Preablation Dynamics of Graphite Observed by Ultrafast Electron Crystallography

By means of time-resolved electron crystallography, we report direct observation of the structural dynamics of graphite, providing new insights into the processes involving coherent lattice motions and ultrafast graphene ablation. When graphite is excited by an ultrashort laser pulse, the excited carriers reach their equilibrium in less then one picosecond by transferring heat to a subset of strongly coupled optical phonons. The time-resolved diffraction data show that on such a time scale the crystal undergoes a contraction whose velocity depends on the excitation fluence. The contraction is followed by a large expansion which, at sufficiently high fluence, leads to the ablation of entire graphene layers, as recently predicted theoretically.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Continuous Time-Resolved X-ray Diffraction of the Biocatalyzed Reduction of Mn Oxide

Here we report the first continuous time-resolved X-ray diffraction analysis of a biologically mediated mineral reaction. We incubated total membrane (TM) fractions of the facultative anaerobe Shewanella oneidensis in an anoxic environmental reaction cell with formate (as electron donor via formate dehydrogenase) and powdered birnessite, a layered Mn{sup 3+,4+} oxide common to many soils. Using both synchrotron and conventional X-ray sources, we irradiated the reaction mixtures for up to two weeks and observed bioreduction and dissolution of birnessite and the concomitant precipitation of rhodochrosite (Mn{sup +C}O{sub 3}) and hausmannite (Mn{sup 2+}Mn{sub 2}{sup 3+}O{sub 4}). The high time resolution of these experiments documented systematic changes in crystal structure during the breakdown of birnessite and the emergence of nanocarystalline rhodochrosite. In addition, the relative abundances of birnessite and rhodochrosite were quantified over time for different concentrations of TM fraction, allowing for the determination of rate equations that govern this bioreaction. Importantly, constant irradiation for two weeks did not stop the enzymatic reaction, suggesting that enzymes may be more resilient than whole cells when exposed to X-ray radiation.

36 MATERIALS SCIENCE↗