RICH (Robotic Interface Control & Handling) System for VULCAN

High flux neutron beam and high efficiency detectors warrant quick turn arounds of neutron diffraction measurements at the engineering materials diffractometer VULCAN. Efficient change and alignment of samples and automatic measurements at VULCAN are desired for better use of neutron beam time by users. In this work, we aim to develop a proof-of-concept Robotic Interactive Control & Handling System (RICH) for sample handling at VULCAN that could assist high throughput experiments and reduce the overhead time significantly. This was realized by a six-axis desktop robot with trained AI models. The trained AI models can recognize and locate samples in various types of positions in a live video stream. In addition, we developed smart algorithms which used our models on multiple cameras to recognize where samples are with respect to multiple point of views, and then using user-inputted parameters, align them to perform complex measurements.

42 ENGINEERING↗

Neutrons in Structural Biology: Challenges and Opportunities (Workshop Report)

Gaining a thorough understanding of biological systems requires building our knowledge about biological processes from the level of atoms and electrons, and up to whole organisms. Such comprehensive knowledge will allow for a predictive understanding of complex biological systems behavior. It will guide us in the design and development of novel therapeutics and vaccines to tackle existing health threats and to prepare for future pandemics, and it will provide information necessary to create new biomaterials and bio-inspired technologies through manipulation of biological macromolecules, their assemblies, single cells and even microorganisms. Reaching these goals will require a synergistic combination of multiple experimental techniques with molecular calculations and predictive simulations, and the design and development of new techniques and capabilities that bridge current knowledge and technology gaps. Neutron scattering provides unique information about the biomacromolecular structure and function and can play a major role in achieving these goals. A workshop was held to engage the scientific community in identifying pressing challenges in biochemistry, structural biology, enzymology and structure-guided drug design not solved with the current neutron scattering technologies or utilizing other structural biology techniques such as X-ray crystallography, NMR, and cryo-EM. The workshop brought together structural biology, biochemistry and computational experts, as well as early career researchers and students, creating a forum for discussing scientific advancement and collaboration. The workshop included a one-day satellite training workshop where graduate students and postdoctoral researchers were educated in the application of neutron crystallography and small-angle scattering in structural biology. Furthermore, the Instrument Scientific Advisory Board (ISAB) for the development of a macromolecular neutron diffractometer at ORNL’s Second Target Station was introduced at the workshop. The major outcome was that neutrons can provide atomic-level understanding of biomacromolecular structure, function and dynamics which is of paramount importance for addressing the identified challenges. Neutron crystallography, in particular, can resolve long-standing biochemical issues regarding enzyme function by delineating the underlying chemistry and can have a major impact on the design of small-molecule therapeutics, especially in combination with molecular computation (quantum chemistry and molecular dynamics simulations) and the emerging artificial intelligence (AI)-assisted drug design technologies. The unique properties of neutrons, including their high sensitivity to hydrogen and their non-destructive nature, make them ideal probes of biological matter. There is a palpable need in the scientific community to expand and enhance the impact of neutron sciences on biology. Neutron crystallography is the only structural biology method capable of determining positions of all hydrogen atoms in proteins, nucleic acids and their complexes at near-physiological temperatures and of unstable species at cryogenic temperatures. Moreover, neutron analysis is non-ionizing, non-destructive and does not perturb the structure or redox chemistry of active site metal centers and clusters in proteins, which can be invaluable for studying radiation-sensitive metalloprotein complexes. Further, neutron energies used in scattering applications are similar to atomic motions, permitting neutron spectroscopies to characterize the dynamics of biomacromolecules on the picosecond to microsecond timescales. The different sensitivities of neutrons to protium (H) and deuterium (D) isotopes of hydrogen allow enhanced visibility of specific parts of biological complexes through isotopic labeling. The impact of neutrons will be most powerful when neutron scattering is combined with complementary experimental techniques that use photons and electrons, and with high-performance computing. The interconnection and mutuality of the experimental and theoretical capabilities will drive discoveries in biological and health sciences to generate more complete picture of complex biological systems. The major limitation in the field of biological neutron crystallography has been signal-to-noise, demanding large samples that are difficult to produce for the majority of biomacromolecules and limiting the applicability of this technique in biological sciences. A neutron crystallography instrument at the Second Target Station will revolutionize biological science with neutrons by engaging a large scientific community of structural biologists, enabling successful neutron diffraction experiments from radically smaller biomacromolecular crystals, resolving unanswered biochemical questions, and meaningfully contributing to rational drug design. The meeting highlighted 10 grand challenges that will be addressed with this advanced capability over the next decade and beyond, and the recommendations required to help address them are given below.

59 BASIC BIOLOGICAL SCIENCES↗

Status Report on Design of In-situ Thermomechanical Testing at LANSCE

Nuclear fuel encounters severe thermomechanical environments in which its mechanical response is determined by its microstructure, temperature and stress level histories. Simulating the response of such microstructures is crucial for predicting both performance and transient fuel mechanical responses and experimental verification of such predictions is therefore of great interest. While most of the deformation in a nuclear fuel rod occurs in the cladding, deformation of the fuel itself is still of interest with deformation mechanisms at operating temperature and above including creep, swelling, cracking as well as pellet-clad interaction. Characterization of these properties and understanding of the underlying deformation phenomena at operating or excursion temperatures is therefore of great importance for development and ultimately licensing of improved and novel nuclear fuel forms. Diffraction techniques offer unique insight on the atomistic (e.g. crystal structure) and microstructure (e.g. phase transformations, texture, defects) length scales and have a long history of providing unique data to inform relevant deformation models that enable the required predictive capabilities. For example, dislocations lead to diffraction peak broadening that can be characterized to estimate the dislocation density and study the role of dislocations on the deformation while measuring lattice strains allows to studie load sharing in two phase materials. In this report the requirements for a sample environment for high temperature deformation of nuclear fuels are defined. The HIPPO neutron time-of-flight diffractometer at LANSCE will host this sample environment and is also described. This instrument covers diffraction angles from 140° to 40° and is also equipped with an event-mode neutron imaging detector system, enabling energy-resolved neutron imaging in parallel with the diffraction that could measure sample temperature from Doppler broadening of neutron absorption resonances or measure pore densities from changes in the attenuation. Designs of devices to characterize thermomechanical properties of nuclear fuel without diffraction are also considered to guide the design. While this report is focused on applications for nuclear fuels, the device can also characterize cladding, moderator or structural materials and therefore contribute to other fields of research and development for advanced reactors. The temperatures planned to be reached are above 2000℃, thus enabling characterization of LWR reactor fuels under accident scenarios but also reaching temperatures of fuels developed for nuclear thermal propulsion and providing opportunities to characterize those. In conjunction with the energy-resolved neutron imaging detector, this setup would allow to measure neutron cross-sections at high temperatures, filling a gap towards development of reactors operating at high temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multimodal Instrument Concepts for Chemical Sciences at Second Target Station

The development of advanced chemical and energy systems is inherently complex, relying heavily on their unique pathways. Because no two catalysts or batteries follow exactly the same kinetic trajectories, conventional sequential measurements often obscure crucial relationships between structure and dynamics through statistical averaging. This report introduces two neutron scattering instrument concepts for the Second Target Station (STS) specifically designed to overcome this barrier: the Extended Q-range Diffractometer (EQD) and the Multimodal Chemical Spectrometer (MCS).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational Optimization of A 3D Printed Collimator

This contribution describes the computational methodology behind an optimization procedure for a scattered beam collimator. The workflow includes producing a file that can be manufactured via additive methods. A conical collimator, optimized for neutron diffraction experiments in a high pressure clamp cell, is presented as an example. In such a case the scattering from the sample is much smaller than that of the pressure cell. Monte Carlo Ray tracing in MCViNE was used to model scattering from a Si powder sample and the cell. A collimator was inserted into the simulation and the number and size of channels were optimized to maximize the rejection of the parasitic signal coming from the complex sample environment. Constraints, provided by the additive manufacturing process as well as a specific neutron diffractometer, were also included in the optimization. The source code and the tutorials are available in c3dp (Islam (2019)).

74 ATOMIC AND MOLECULAR PHYSICS↗

What Is the Limit of Quantification for the Minor Phase in Time-of-Flight Neutron Diffraction? A Case Study on Fe and Ni Powder Mixtures at VULCAN

A phase present in small quantities within materials may not simply serve as a secondary component; it can play a crucial role in determining the integrity, properties, and performance of the material. These minor but important phases usually draw attention in material design and processing for fundamental understanding as well as material quality control. Accurately quantifying a minor phase amid a majority phase, especially at extremely low fractions, remains a challenging task. Time-of-flight neutron diffraction, coupled with advanced pattern analysis techniques like Rietveld refinement, is a powerful tool for crystal structure identification and phase quantification. The deep penetrating capability of neutrons enables the detection and quantification of trace phases within materials. In this study, the quantification limits of time-of-flight neutron diffraction were explored using the VULCAN diffractometer at the Spallation Neutron Source, using Fe–Ni powder mixtures as a sample system. By comparing the refinement results to the known weighed values, it was determined that the reliable quantification of a minor Ni phase is achievable down to about 0.1 wt% while a Ni fraction as low as 0.02 wt% is difficult to trace. Effective control of the refinement parameters, especially the profile function parameters, are found to significantly influence the convergence of fittings and the accuracy of phase quantification.

Rietveld refinement↗

A Smart Vision-Aided RICH (Robotic Interface Control and Handling) System for VULCAN

High-flux neutron beams and high-efficiency detectors enable rapid neutron diffraction measurements at the Engineering Materials Diffractometer (VULCAN) at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL). To optimize beam time utilization, efficient sample exchange, alignment, and automated measurements are essential. Recent advances in artificial intelligence (AI) have expanded the capabilities of robotic systems. Here, we report the development of a Robotic Interactive Control and Handling (RICH) system for sample handling at VULCAN, designed to support high-throughput experiments and reduce overhead time. The RICH system employs a six-axis desktop robot integrated with AI-based computer vision models capable of recognizing and localizing samples in real time from instrument and depth-resolving cameras. Vision algorithms combine these detections to align samples with designated measurement positions or place them within complex sample environments such as furnaces. This integration of machine learning-assisted vision with robotic handling demonstrates the feasibility of autonomous sample detection and preparation, offering a pathway toward fully unmanned neutron scattering experiments.

automation↗

Through-Thickness Microstructure Characterization in a Centrifugally Cast Austenitic Stainless Steel Nuclear Reactor Primary Loop Pipe Using Time-of-Flight Neutron Diffraction

The US code of Federal Regulations mandates regular inspection of centrifugally cast austenitic stainless steel pipe, commonly used in primary cooling loops in light-water nuclear power plants. These pipes typically have a wall thickness of ~8 cm. Unfortunately, inspection using conventional ultrasonic techniques is not reliable as the microstructure strongly attenuates ultrasonic waves. Work is ongoing to simulate the behavior of acoustic waves in this microstructure and ultimately develop an acoustic inspection method for reactor inspections. In order to account for elastic anisotropy in the material, the texture in the steel was measured as a function of radial distance though the pipe wall. Experiments were conducted on two 10 × 12.7 × 80 mm radial sections of a cast pipe using neutron diffraction scans of 2 mm slices using the HIPPO time-of-flight neutron diffractometer at the Los Alamos Neutron Science Center (LANSCE, Los Alamos, NM, USA). Strong textures dominated by a small number of austenite grains with their (100) direction aligned in the radial direction of the pipe were observed. ODF analysis indicated that up to 70% of the probed volume was occupied by just three single-grain orientations, consistent with grain sizes of almost 1 cm. Texture and phase fraction of both ferrite and austenite phases were measured along the length of the samples. These results will inform the development of a more robust diagnostic tool for regular inspection of this material.

42 ENGINEERING↗

Cryogenic X-ray crystallographic studies of biomacromolecules at Turkish Light Source " Turkish DeLight "

X-ray crystallography is a robust and powerful structural biology technique that provides high-resolution atomic structures of biomacromolecules. Scientists use this technique to unravel mechanistic and structural details of biological macromolecules (e.g., proteins, nucleic acids, protein complexes, protein-nucleic acid complexes, or large biological compartments). Since its inception, single-crystal cryocrystallography has never been performed in Türkiye due to the lack of a single-crystal X-ray diffractometer. The X-ray diffraction facility recently established at the University of Health Sciences, Istanbul, Türkiye will enable Turkish and international researchers to easily perform high-resolution structural analysis of biomacromolecules from single crystals. Here, we describe the technical and practical outlook of a state-of-the-art home-source X-ray, using lysozyme as a model protein. The methods and practice described in this article can be applied to any biological sample for structural studies. Therefore, this article will be a valuable practical guide from sample preparation to data analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Rf-sputtered cadmium sulfide 'thin crystals'

RF-sputtered CdS thin films structural and electrical characteristics from X ray diffractometer tracings, reflection electron diffraction and X ray double crystal spectrometry

Lagnado, I.↗

Science aspects of a remotely controlled Mars surface roving vehicle.

Particular attention is given to aspects pertinent to teleoperation, remote control, onboard control, and man-machine relationships in carrying out scientific operations with such a vehicle. It is assumed that landed operations would comprise one Martian year and that the traverse would extend across an area approximately 500 km wide. The mission is assumed to be planned for the early 1980s. Its objective is to obtain data which will aid in answering a number of questions regarding the history of the solar system, the formation of Mars, and the evolution of life on Mars. A series of candidate rover payloads is proposed to meet the requirements. The smallest payload includes a TV camera, a general-purpose manipulator arm, a crusher and siever, an X-ray diffractometer-spectrometer, a gravimeter, a magnetometer, meteorological instruments, and a radio transponder.

Choate, R.↗

Texturing and residual stress in metals as a result of sliding

Pole figures of the texturing produced by friction in the alloys Cu - 10 at. % Sn, Cu - 10 at. % Si, 440 C stainless steel, and AISI 52100 bearing steel were obtained with an energy-dispersive X-ray diffractometer. While the texturing behavior of these alloys is generally similar to that of pure metals, the 52100 steel and the Cu5Si phase of Cu - 10 at. % Si show no texturing at the loads and speeds used in this experiment. Photographic methods were used in an attempt to measure the uniform residual stress in the wear tracks produced on some pure metals. The stress in copper and iron was, however, below the limit of detectability - about 4.3 x 10 to the 7th power N/sq m (6000 psi). Line broadening under all test conditions in the case of copper and at high load and speed conditions in iron is attributed, at least in part, to the reduction of crystallite size and, perhaps, to nonuniform residual stress, as well.

Wheeler, D. R.↗

Low orthopyroxene from a lunar deep crustal rock - A new pyroxene polymorph of space group P21ca

Bronzite crystals (En86Fs11Wo3) from a slowly-cooled lunar troctolitic granulite, have space group P21ca, a postulated, but previously unreported space group. Diffractions violating the b-glide extinction conditions have been observed in long-exposure X-ray precession photographs from three of these crystals and on an automated X-ray diffractometer. P21ca is a subgroup of the common orthopyroxene space group Pbca, and its cell dimensions (a = 18.235 plus or minus 0.004 A, b = 8.831 plus or minus 0.002 A, c = 5.189 plus or minus 0.001 A) are similar to those of terrestrial bronzites. It is postulated that the lower symmetry space group has developed as a result of very slow cooling at pressures of one to two kilobars deep in the lunar crust.

Smyth, J. R.↗

Reactively sputtered thin film photovoltaic devices

The feasibility of a reactively sputtered thin film CdS - Cu2S solar cell is proven. Identification of the reactively sputtered Cu2S film is made by X-ray diffractometer and spectro-transmission measurements. Because of its simplicity, economical use of material, and high yield, the reactive sputtering process promises to be a low cost method for producing CdS - Cu2S solar cells.