Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET

Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cryogenic Front-End ASICs for Low-Noise Readout of Charge Signals

This paper presents design details and measurement results of LArASIC, a front-end application specific integrated circuit (ASIC) designed for low-noise readout of charge signals generated in neutrino study experiments within liquid argon time projection chambers. LArASIC comprises of 16-channels of programmable charge amplification and pulse shaping stages that provide a voltage readout proportional to the input charge and was optimized for operation at liquid argon temperature, i.e., 89 K. The chip was fabricated in a 180 nm CMOS process. Measurements at liquid nitrogen temperature, i.e., 77 K, indicate that the channel outputs have high linearity (INL < 0.1%) within the operating range, an equivalent noise charge of 534 electrons for a peaking time of 1 µs and a detector capacitance of 150 pF, and a worst-case inter-channel cross-talk of 0.35%. The paper also presents design choices made in the process of migrating LArASIC to CHARMS, an ASIC to be fabricated in a 65 nm process that includes all features provided by LArASIC, along with additional digital programmability for improved robustness and flexibility. CHARMS is intended for use in future high-energy physics experiments that require high-resolution charge or light readout with shorter pulse peaking times.

47 OTHER INSTRUMENTATION↗

Signal digitizing system and method based on amplitude-to-time optical mapping

A signal digitizing system and method based on analog-to-time optical mapping, optically maps amplitude information of an analog signal of interest first into wavelength information using an amplitude tunable filter (ATF) to impress spectral changes induced by the amplitude of the analog signal onto a carrier signal, i.e. a train of optical pulses, and next from wavelength information to temporal information using a dispersive element so that temporal information representing the amplitude information is encoded in the time domain in the carrier signal. Optical-to-electrical conversion of the optical pulses into voltage waveforms and subsequently digitizing the voltage waveforms into a digital image enables the temporal information to be resolved and quantized in the time domain. The digital image may them be digital signal processed to digitally reconstruct the analog signal based on the temporal information with high fidelity.

47 OTHER INSTRUMENTATION↗

Injection moulding of optical functional micro structures using laser structured, PVD-coated mould inserts

Micro structured optical plastics components are intensively used i. e. in consumer electronics, for optical sensors in metrology, innovative LED-lighting or laser technology. Injection moulding has proven to be successful for the large-scale production of those parts. However, the production of those parts still causes difficulties due to challenges in the moulding and demoulding of plastics parts created with laser structured mould inserts. A complete moulding of the structures often leads to increased demoulding forces, which then cause a breaking of the structures and a clogging of the mould. An innovative approach is to combine PVD-coated (physical vapour deposition), laser structured inserts and a variothermal moulding process to create functional mic8iüro structures in a one-step process. Therefore, a PVD-coating is applied after the laser structuring process in order to improve the wear resistance and the anti-adhesive properties against the plastics melt. In a series of moulding trials with polycarbonate (PC) and polymethylmethacrylate (PMMA) using different coated moulds, the mould temperature during injection was varied in the range of the glass transition and the melt temperature of the polymers. Subsequently, the surface topography of the moulded parts is evaluated by digital 3D laser-scanning microscopy. The influence of the moulding parameters and the coating of the mould insert on the moulding accuracy and the demoulding behaviour are being analysed. It is shown that micro structures created by ultra-short pulse laser ablation can be successfully replicated in a variothermal moulding process. Due to the mould coating, significant improvements could be achieved in producing micro structured optical plastics components.

36 MATERIALS SCIENCE↗

Implant for in-vivo parameter monitoring, processing and transmitting

The present invention relates to a completely implantable intracranial pressure monitor, which can couple to existing fluid shunting systems as well as other internal monitoring probes. The implant sensor produces an analog data signal which is then converted electronically to a digital pulse by generation of a spreading code signal and then transmitted to a location outside the patient by a radio-frequency transmitter to an external receiver. The implanted device can receive power from an internal source as well as an inductive external source. Remote control of the implant is also provided by a control receiver which passes commands from an external source to the implant system logic. Alarm parameters can be programmed into the device which are capable of producing an audible or visual alarm signal. The utility of the monitor can be greatly expanded by using multiple pressure sensors simultaneously or by combining sensors of various physiological types.

60 APPLIED LIFE SCIENCES↗

Continued Data Acquisition Development

This task focused on improving techniques for integrating data acquisition of secondary particles correlated in time with detected cosmic-ray muons. Scintillation detectors with Pulse Shape Discrimination (PSD) capability show the most promise as a detector technology based on work in FY13. Typically PSD parameters are determined prior to an experiment and the results are based on these parameters. By saving data in list mode, including the fully digitized waveform, any experiment can effectively be replayed to adjust PSD and other parameters for the best data capture. List mode requires time synchronization of two independent data acquisitions (DAQ) systems: the muon tracker and the particle detector system. Techniques to synchronize these systems were studied. Two basic techniques were identified: real time mode and sequential mode. Real time mode is the preferred system but has proven to be a significant challenge since two FPGA systems with different clocking parameters must be synchronized. Sequential processing is expected to work with virtually any DAQ but requires more post processing to extract the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PVT Compensation for Wilkinson Single-Slope Measurement Systems

A pulse-width locked loop (PWLL) circuit is reported that compensates for process, voltage, and temperature (PVT) variations of a linear ramp generator within a 12-bit multi-channel Wilkinson (single-slope integrating) Analog-to-Digital (ADC). This PWLL was designed and fabricated in a 0.5- m Silicon Germanium (SiGe) BiCMOS process. Simulation and silicon measurement data are shown that demonstrate a large improvement in the accuracy of the PVT-compensated ADC over the uncompensated ADC.

Britton, Jr, Charles L↗

Eigenvalue-Based Micromagnetic Analysis of Switching in Spin-Torque-Driven Structures

We present an eigenvalue-based approach for studying the magnetization dynamics in magnetic nanostructures driven by spintronic excitations, such as spin-transfer torque and spin-orbit torque. The approach represents the system dynamics in terms of normal oscillation modes (eigenstates) with corresponding complex eigenfrequencies. The dynamics is driven by a small number of active eigenstates and often considering just a single eigenstate is sufficient. We develop a perturbation theory that provides semianalytical dynamic solutions by using eigenstates for the case in the absence of damping and spintronic excitations as a basis. The approach provides useful insights into dynamics in such systems and allows solving several difficulties in their modeling, such as extracting the switching current in magnetic random-access memories and understanding switching mechanisms. We show that the presented approach directly predicts the critical switching current, i.e., switching current for an infinite time. The approach also provides solutions for the switching dynamics allowing the switching current to be obtained for a finite switching time, provided that the system symmetry is broken, e.g., by tilting the polarizer, so that switching by a finite pulse is possible.

42 ENGINEERING↗

Burst design and signal processing for the speed of sound measurement of fluids with the pulse-echo technique

The pulse-echo technique determines the propagation time of acoustic wave bursts in a fluid over a known propagation distance. It is limited by the signal quality of the received echoes of the acoustic wave bursts, which degrades with decreasing density of the fluid due to acoustic impedance and attenuation effects. Signal sampling is significantly improved in this work by burst design and signal processing such that a wider range of thermodynamic states can be investigated. Applying a Fourier transformation based digital filter on acoustic wave signals increases their signal-to-noise ratio and enhances their time and amplitude resolutions, improving the overall measurement accuracy. In addition, burst design leads to technical advantages for determining the propagation time due to the associated conditioning of the echo. It is shown that the according operation procedure enlarges the measuring range of the pulse-echo technique for supercritical argon and nitrogen at 300 K down to 5 MPa, where it was limited to around 20 MPa before.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Continuous measurement of the arrival times of x-ray photon sequence

In order to record x-ray pulse profile for x-ray pulsar-based navigation and timing, this paper presents a continuous, high-precision method for measuring arrival times of photon sequence with a common starting point. In this method, a high stability atomic clock is counted to measure the coarse time of arrival photon. A high resolution time-to-digital converter is used to measure the fine time of arrival photon. The coarse times and the fine times are recorded continuously and then transferred to computer memory by way of memory switch. The pulse profile is obtained by a special data processing method. A special circuit was developed and a low-level x-ray pulse profile measurement experiment system was setup. The arrival times of x-ray photon sequence can be consecutively recorded with a time resolution of 500 ps and the profile of x-ray pulse was constructed. The data also can be used for analysis by many other methods, such as statistical distribution of photon events per time interval, statistical distribution of time interval between two photon events, photon counting histogram, autocorrelation and higher order autocorrelation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Body composition to climate change studies - the many facets of neutron induced prompt gamma-ray analysis

In-vivo body composition analysis of humans and animals and in-situ analysis of soil using fast neutron inelastic scattering and thermal neutron capture induced prompt-gamma rays have been described. By measuring carbon (C), nitrogen (N) and oxygen (O), protein, fat and water are determined. C determination in soil has become important for understanding below ground carbon sequestration process in the light of climate change studies. Various neutron sources ranging from radio isotopic to compact 14 MeV neutron generators employing the associated particle neutron time-of-flight technique or micro-second pulsing were implemented. Gamma spectroscopy using recently developed digital multi-channel analyzers has also been described.

54 ENVIRONMENTAL SCIENCES↗

Toward scalable information processing with ultracold polar molecules in an electric field: A numerical investigation

We numerically investigate the possibilities of driving quantum algorithms with laser pulses in a register of ultracold NaCs polar molecules in a static electric field. We focus on the possibilities of performing scalable logical operations by considering circuits that involve intermolecular gates (implemented on adjacent interacting molecules) to enable the transfer of information from one molecule to another during conditional laser-driven population inversions. We study the implementation of an arithmetic operation (the addition of 0 or 1 on a binary digit and a carry in) which requires population inversions only and the Deutsch-Jozsa algorithm which requires a control of the phases. Under typical experimental conditions, our simulations show that high-fidelity logical operations involving several qubits can be performed in a time scale of a few hundreds of microseconds, opening promising perspectives for the manipulation of a large number of qubits in these systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Time-Gated, Time-Correlated Single-Photon-Counting Lidar to Observe Atmospheric Clouds at Submeter Resolution

Most lidars used for cloud observations have the range resolution of about 10 m, so they are incapable of resolving submeter-scale processes that are crucial to cloud evolution. This article describes a prototype of a ground-based, vertically pointing, time-gated, time-correlated single-photon-counting lidar (referred to as the T2 lidar) developed to explore atmospheric clouds at range resolution two orders of magnitude finer than traditional atmospheric lidars. The T2 lidar emits green-light pulses (532 nm) at a repetition rate of 20.6 kHz and a pulse width of ∼650 ps, which enables the observation of aerosol and cloud layers at heights from a few hundred meters to 7.28 km above the ground level at range resolution down to 10 cm. In addition, a digital delay pulse generator controls the detector to only receive photons for a short period after each laser pulse. This time-gated technique blocks photons arriving from regions outside the target zone, thus significantly reducing the noise level and allowing observation even inside clouds. Initial observations show that the T2 lidar can detect sharp cloud boundaries and fine structures near the cloud base. Such refined measurements of cloud structure could lead to an improved understanding of microphysical processes such as droplet activation, entrainment and mixing, and precipitation.

54 ENVIRONMENTAL SCIENCES↗

Measurement and Analysis of Field Emission Electrons in the LCLS Gun

The field emission was measured during the high-power testing of the LCLS photocathode RF gun. A careful study and analysis of the field emission electrons, or dark current is important in assessing the gun's internal surface quality in actual operation, especially those surfaces with high fields. The first indication of a good RF gun design and fabrication is short processing time to the required fields and low electron emission at high fields. The charge per 2 microsecond long RF pulse (the dark charge) was measured as a function of the peak cathode field for the 1.6 cell, 2.856GHz LCLS RF gun. Faraday cup data was taken for cathode peak RF fields up to 120MV/m producing a maximum of 0.6nC/RF pulse for a diamond-turned polycrystalline copper cathode installed in the gun. Digitized images of the dark charge were taken using a 100 micron thick YAG crystal for a range of solenoid fields to determine the location and angular distribution of the field emitters. The FN plots and emitter image analysis will be described in this paper.

43 PARTICLE ACCELERATORS↗

ADC Nonlinearity Correction for the Majorana Demonstrator

Imperfections in analog-to-digital conversion cannot be ignored when signal digitization requirements demand both wide dynamic range and high resolution, as is the case for the MAJORANA DEMONSTRATOR 76 Ge neutrinoless double beta decay search. Enabling the experiment's high-resolution spectral analysis and efficient pulse shape discrimination required careful measurement and correction of ADC nonlinearites. Here, a simple measurement protocol was developed that did not require sophisticated equipment or lengthy data taking campaigns. A slope-dependent hysteresis was observed and characterized. A correction applied to digitized waveforms prior to signal processing reduced the differential and integral nonlinearites by an order of magnitude, eliminating these as dominant contributions to the systematic energy uncertainty at the double-beta decay Q value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronics Upgrades to the Green is Clean Phoswich Detector Systems and Programmatic Implementation at LANL - Phase II Completion - 18403

Los Alamos National Laboratory (LANL) radiological facilities produce low-density room trash that, in many cases, is not contaminated with radioactivity. It has been estimated that 50 to 90% of low-density room trash is free of radioactive contamination and eligible for inclusion in LANL's Green is Clean (GIC) program. The GIC program is a verification program for non-regulated waste from radiation controlled areas that has been actively segregated as nonradioactive through the use of the waste generator's acceptable knowledge. The GIC program has employed two large area Phoswich gamma ray detector systems (HERCULES and ZEUS) to verify that GIC candidate low-density waste contains no radioactivity above background. The large area (127 cm{sup 2}) Phoswich detectors consist of a thin NaI front crystal (3 mm thick) that is optically coupled to a thick CsI back crystal (50 mm thick). The scintillation properties of the two crystals are different enough to allow the system's electronic components to identify the origin of any pulse. The original systems utilize Nuclear Instrumentation Module (NIM) electronics to process the detector signals. The electronics currently in use by the systems are out of date and some components are no longer manufactured. In 2015, phase I upgrades to the GIC detector systems were completed. Phase I objectives included identifying more modern commercially available electronics that could replace the NIM electronics. A pulse shape discriminator (PSD) module, the Digital Gamma Finder (DGF) Pixie-4 made by XIA LLC, that fits in a compact National Instruments{sup TM} PXI chassis was identified to replace the majority of the original NIM bin electronics - a single Pixie-4 module replaces four NIM amplifiers and four NIM pulse shape analyzers (PSAs). Another phase I objective was to show that that new PSD could separate out the NaI and CsI detector signals in a manner equivalent to or better than the NIM electronics. Proof of concept was achieved in 2015 when a prototype upgrade system on ZEUS was built and tested and gating parameter settings were determined that successfully separated the NaI and CsI signals. Phase II required establishing a LabVIEW software interface with Pixie-4 electronics in lieu of the manufacturer provided Pixie-4 software called the Pixie Viewer. In addition, phase II included 1) final optimization of the gating parameters on the prototype Pixie-4 ZEUS system, 2) finalizing Requirements, Design and Test Plan documents, 3) LabVIEW software interface quality assurance (QA) testing, 4) setting up the HERCULES system with the Pixie-4 upgrade electronics, 5) check source and background calibration of both systems, 6) absolute efficiency determination on both systems and 7) procedure revisions and implementation of both systems into routine operations. In 2017 phase II was completed including the preparation of detailed Requirements, Design and Test Plan documents. The LabVIEW interface software that communicates and controls the Pixie-4 has been completed, merged with the preexisting LabVIEW operations software and fully tested. Gating parameter optimization, configuration of HERCULES with the Pixie-4 electronics, check source and background calibrations and absolute efficiency determinations have all been performed - quantitative results are presented in the full paper. For performance validation, comparison measurements of actual GIC bags on both the HERCULES system using the old NIM Bin electronics and the ZEUS system using the upgraded Pixie-4 electronics have been done and evaluated. Finally, procedure revisions and implementation of both systems into routine operations is currently in process and planned to be complete by the end of calendar year 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

UWB radar technique for arc detection in coaxial cables and waveguides

As spread spectrum technology has revolutionized the communications industry, Ultra Wide Band (UWB) technology is dramatically improving radar performances. These advanced signal processing techniques have been adapted to coaxial cables and waveguides to provide new features and enhanced performance on arc detection. UWB signals constituted by a sequence of chips (properly chosen to reduce side lobes and to improve detection accuracy) are transmitted along the transmission lines at a specified Pulse Repetition Frequency (PRF) and their echoes are received by means of directional couplers. The core of the receiver is an ultra high-speed correlator implemented in a Digital Signal Processor (DSP). When a target (arc) is detected, its position and its 'radar cross section' are calculated to be able to provide the arc position along the transmission line and to be able to classify the type of detected arc. The 'background scattering' is routinely extracted from the received signal at any pulse. This permits to be resilient to the background structure of transmission lines (bends, junctions, windows, etc.). Thanks to the localization feature, segmentation is also possible for creating sensed and non-sensed zones (for example, to be insensitive to antenna load variations)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-and-space resolved comparison of plasma expansion velocities in high-power diodes with velvet cathodes

Time-and-space resolved comparison of the expansion velocities of plasmas in the planar diode with cathodes made of carbon velvet and polymer velvet has been performed. The diode was powered by a 200 kV, 110 ns pulse, and the peak current density was nearly 477 A/cm{sup 2}. A four-channel high speed framing camera (HSFC) was used to observe the formation and subsequent movement of the cathode plasmas. More accurate and valuable information about the two-dimensional (radial and axial) velocity components of the cathode plasmas was also acquired by utilizing the digital image processing methods. Additionally, the perveance model based on the Child-Langmuir law was used to calculate the expansion velocities of the diode plasmas from voltage and current profiles. Results from the two diagnostics were compared. Comparing the average values of the radial and axial velocity components indicated that the former was much larger than the latter during the initial period of the current. It was also found that the radial velocity of the carbon velvet cathode (190 cm/{mu}s) was much larger than that (90 cm/{mu}s) of the polymer velvet cathode. Moreover, the average values of both the radial and axial velocity components of the carbon velvet cathode were typically in the range of 2.5 {+-} 1.5 cm/{mu}s, which were smaller than that of the polymer velvet cathode during the current flattop. These results, together with the comparison of calculated values from the perveance model, indicated that the diode with carbon velvet cathode was more robust as compared with the polymer velvet cathode for the same electron current densities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗