Search NASA⌕ Search

SEARCH · Search NASA

Results for “digitalization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Evaluation of Digital Twin Modeling and Simulation

A digital twin has intelligent modules that continuously monitor the condition of the individual components and the whole of a system. Digital twins can provide nuclear power plants (NPP) operators an unprecedented level of monitoring, control, supervision, and security by contributing a greater volume of data for more comprehensive data analysis and increased accuracy of insights and predictions for decision making throughout the entire NPP lifecycle. NPP operators and managers have historically relied on limited, second hand or incomplete data. With proper implementation, digital twins can provide a central hub of all intel that allows for a multidisciplinary view of an NPP. This equips operators and managers with the ability to have more information, context, and intel that can be used for greater granularity during planning and decision making. Digital twins can be used in many activities as the technology has many different concepts surrounding it. From the various definitions of a digital twin within the industry, digital twins can be differentiated by levels of integration/automation. The three main models include digital model, digital shadow, and digital twin. Digital twins offer many potential advancements to the nuclear industry that could reduce costs, improve designs, provide safer operation, and improve their overall security.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Theoretical Open Architecture Framework and Technology Stack for Digital Twins in Energy Sector Applications

Digital twin is often viewed as a technology that can assist engineers and researchers make data-driven system and network-level decisions. Across the scientific literature, digital twins have been consistently theorized as a strong solution to facilitate proactive discovery of system failures, system and network efficiency improvement, system and network operation optimization, among others. With their strong affinity to the industrial metaverse concept, digital twins have the potential to offer high-value propositions that are unique to the energy sector stakeholders to realize the true potential of physical and digital convergence and pertinent sustainability goals. Although the technology has been known for a long time in theory, its practical real-world applications have been so far limited, nevertheless with tremendous growth projections. In the energy sector, there have been theoretical and lab-level experimental analysis of digital twins but few of those experiments resulted in real-world deployments. There may be many contributing factors to any friction associated with real-world scalable deployment in the energy sector such as cost, regulatory, and compliance requirements, and measurable and comparable methods to evaluate performance and return on investment. Those factors can be potentially addressed if the digital twin applications are built on the foundations of a scalable and interoperable framework that can drive a digital twin application across the project lifecycle: from ideation to theoretical deep dive to proof of concept to large-scale experiment to real-world deployment at scale. This paper is an attempt to define a digital twin open architecture framework that comprises a digital twin technology stack (D-Arc) coupled with information flow, sequence, and object diagrams. Those artifacts can be used by energy sector engineers and researchers to use any digital twin platform to drive research and engineering. This paper also provides critical details related to cybersecurity aspects, data management processes, and relevant energy sector use cases.

Gourisetti, Sri, Nikhil Gupta (ORCID:0000000188778↗

A probabilistic graphical model foundation for enabling predictive digital twins at scale

A unifying mathematical formulation is needed to move from one-off digital twins built through custom implementations to robust digital twin implementations at scale. This work proposes a probabilistic graphical model as a formal mathematical representation of a digital twin and its associated physical asset. We create an abstraction of the asset–twin system as a set of coupled dynamical systems, evolving over time through their respective state spaces and interacting via observed data and control inputs. The formal definition of this coupled system as a probabilistic graphical model enables us to draw upon well-established theory and methods from Bayesian statistics, dynamical systems and control theory. The declarative and general nature of the proposed digital twin model make it rigorous yet flexible, enabling its application at scale in a diverse range of application areas. Here, we demonstrate how the model is instantiated to enable a structural digital twin of an unmanned aerial vehicle (UAV). The digital twin is calibrated using experimental data from a physical UAV asset. Its use in dynamic decision-making is then illustrated in a synthetic example where the UAV undergoes an in-flight damage event and the digital twin is dynamically updated using sensor data. The graphical model foundation ensures that the digital twin calibration and updating process is principled, unified and able to scale to an entire fleet of digital twins.

42 ENGINEERING↗

Digital Actuator Technology

There are significant developments underway in new types of actuators for power plant active components. Many of these make use of digital technology to provide a wide array of benefits in performance of the actuators and in reduced burden to maintain them. These new product offerings have gained considerable acceptance in use in process plants. In addition, they have been used in conventional power generation very successfully. This technology has been proven to deliver the benefits promised and substantiate the claims of improved performance. The nuclear industry has been reluctant to incorporate digital actuator technology into nuclear plant designs due to concerns due to a number of concerns. These could be summarized as cost, regulatory uncertainty, and a certain comfort factor with legacy analog technology. The replacement opportunity for these types of components represents a decision point for whether to invest in more modern technology that would provide superior operational and maintenance benefits. Yet, the application of digital technology has been problematic for the nuclear industry, due to qualification and regulatory issues. With some notable exceptions, the result has been a continuing reluctance to undertake the risks and uncertainties of implementing digital actuator technology when replacement opportunities present themselves. Rather, utilities would typically prefer to accept the performance limitations of the legacy analog actuator technologies to avoid impacts to project costs and schedules. The purpose of this report is to demonstrate that the benefits of digital actuator technology can be significant in terms of plant performance and that it is worthwhile to address the barriers currently holding back the widespread development and use of this technology. It addresses two important objectives in pursuit of the beneficial use of digital actuator technology for nuclear power plants: 1. To demonstrate the benefits of digital actuator technology over legacy analog sensor technology in both quantitative and qualitative ways. 2. To recognize and address the added difficulty of digital technology qualification, especially in regard to software common cause failure (SCCF), that is introduced by the use of digital actuator technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NRC technical basis for evaluation of its position on protection against common cause failure in digital systems used in nuclear power plants - 378

Digital technology has advantages over analog systems, including automated monitoring and alerts for standby safety functions, and predictive algorithms to maintain critical safety systems. Additionally, digital technology generally has higher reliability and can be designed to reduce single point vulnerabilities. For these reasons many nuclear plants have applied digital technology to safety and non-safety related applications, including reactor protection system, feedwater and turbine controls, etc. with a corresponding significant improvement in trip reduction. Nonetheless, digital instrumentation and control (I and C) systems also present potential new vulnerabilities that need to be assessed, including potential failures due to increased complexity of digital systems, the introduction of unique failure modes due to software (including software common cause failure (CCF)), and limited operating history of digital systems in nuclear safety related applications compared to analog systems. The fact that software is intangible means that common methods, such as analysis or testing, used for detecting CCF may not be effective when applied to software. Consequently, digital technology is perceived to pose a potential risk from the introduction of undetected systematic faults that could result in CCF. Despite the I and C system upgrades and modifications performed to date, the U.S. Nuclear Regulatory Commission (NRC) and industry stakeholders have identified the need to modernize the regulatory infrastructure to efficiently address risks associated with the use of digital technology for nuclear safety applications and address regulatory uncertainties. The NRC's current position on CCF is guided by the staff requirements memorandum (SRM) on SECY 93-087. The SRM provides specific acceptance criteria for the evaluation of CCF, which the staff implemented in the Branch Technical Position (BTP) 7-19. However, industry stakeholders have proposed using methods to characterize the likelihood of software CCF and eliminate it from further consideration in a defense-in-depth and diversity analysis. The NRC's current position does not consider these alternatives, and thus corresponding acceptance criteria is not currently available. The work discussed in this paper assesses the underlying technical basis associated with CCF, provides technical support for updating the NRC position and considers proposed methods for addressing potential CCF in digital systems while enhancing efficiency, clarity, and confidence. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of quantitative methods for reliability testing of a nuclear power plant digital rod position indication diagnostic system - 391

Obsolescence, aging, reliability, and performance issues are driving nuclear facilities to replace conventional analog Instrumentation and Control (I and C) systems with digital technologies. In addition, the designs of the next generation of nuclear reactors, including Small Modular Reactors (SMRs), will incorporate digital I and C for most, if not all, of their safety and non-safety related functions. As part of an on-going research and development (R and D) effort under the auspices of the U.S. Department of Energy (DOE), Analysis and Measurement Services Corporation (AMS) is developing a platform to provide automated testing of digital I and C systems and create a standard method of evaluation for reliability assessments. This hands-on R and D effort has produced a Software Reliability Tester (SRT), which is a set of software and hardware tools designed to automate the testing of digital I and C systems to measure and quantify how well the systems perform under normal operating conditions and in the presence of faults. Furthermore, the SRT provides the foundation for a practical tool to automate verification and validation (V and V) activities and reduce the amount of testing time of digital I and C systems. When combined with its capabilities of integrating both reliability and fault tolerance quantification, the SRT can be used to ensure that digital I and C implementations are both safe and cost-effective for the nuclear industry. This paper describes the application of the SRT to perform V and V of a new Digital Rod Position Indication (DRPI) diagnostic system. The DRPI diagnostic system is a digital system that monitors the rod address and rod position data bus voltages of typical DRPI systems in nuclear power plants to detect and diagnose faults. For this application, the SRT was configured to exercise the inputs of the DRPI diagnostic system, and test cases were generated for common system faults such as address and data bit errors, bus voltage, and timing problems. These test cases were applied by the SRT hardware as voltage inputs to the DRPI diagnostic system and the outputs were compared to expected values generated by a model of the DRPI diagnostic system. Included in the paper is a description of the overall design of the SRT including the hardware and software architectures. Methodologies for automating test cases are also described. V and V using the SRT demonstrates the benefits of automated testing and qualification to provide a quantitative assessment of reliability and cost effective implementation of digital I and C in existing and next generation nuclear power plants. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparison of Mutual Awareness in Analog vs. Digital Control Rooms

Control rooms in nuclear power plants are complex, collaborative working environments rife with potential for human error. As control rooms evolve from analog to digital interface environments, crew communication strategies must change as well. Operators in the analog control room operate the plant and communicate with each other with the help of control boards with large control panels, meters, and switches. Reactor operators could choose a particular set of controls on the particular control board which corresponds to the part of the system of interest. Visual display units (VDU), which became a fixture in the control rooms with the shift to digital human-machine interfaces (HMI), bring benefits for safety and flexibility combining information from various sources. With the increase in automation and the use of digital HMIs operators received their personal sitting workstations where they are able to navigate and operate the plant. The amount of information increased as well as the complexity of monitoring and analyzing the system states. Also computerized systems cause operators to get absorbed by their personal screens and reduce interaction between the crew members. Therefore, the collaboration and coordination of task demands requires vigilance and mutual awareness. The level of automation has an influence on the level of mutual awareness experienced by operators in the control rooms. Teams function to carry out highly interdependent tasks, requiring synthesis and sharing of information to achieve common goals. Improving the performance of the team necessitates the operators to focus on the system, the surrounding environment, and situational awareness about the system states. Collaboration of team members is critical when employing the digital operating systems as the acute awareness of the overall progress of the group and individual activities of the operators drives the team to the desired end-states of the plant operations. Out-of-the loop (OOTL) performance problems can be referred to as the lack of supervisory control, system monitoring, and information processing in the digital HMIs. Under some circumstances Senior Reactor Operators (SRO) struggle to follow the actions of other Reactor Operators (RO) because with the new digital interfaces SROs lose track of how the procedures are carried out by ROs, which results in the loss of three way communication. Mutual awareness plays a significant role in keeping the SROs in the loop of plant operations. This paper will investigate, through literature review and expert interviews, the impact and human errors attributed to the increasing complexity of new digital main control rooms. Comparison of the new digital interfaces with the analog interfaces in nuclear power plants has the potential to shed light on increasing mutual awareness and three way communications between the SROs and ROs. Further, identification of the human errors and human actions can provide beneficial information, suggesting significant and critical improvements that can be implemented in the main control rooms to increase safety and reliability of new technology. Additionally, insights on mutual awareness for analog vs. digital control rooms can serve to improve human reliability.

99 GENERAL AND MISCELLANEOUS↗

Comparative life cycle assessments: The case of paper and digital media

The consumption of the written word is changing, as media transitions from paper products to digital alternatives. We reviewed the life cycle assessment (LCA) research literature that compared the environmental footprint of digital and paper media. To validate the role of context in influencing LCA results, we assessed LCAs that did not compare paper and print, but focused on a product or component that is part of the Information and Communication Technology (ICT) sector. Using a framework that identifies problems in LCA conduct, we assessed whether the comparative LCAs were accurate expressions of the environmental footprints of paper and print. We hypothesized that the differences between the product systems that produce paper and digital media weaken LCA's ability to compare environmental footprints. We also hypothesized that the characteristics of ICT as an industrial sector weaken LCA as an environmental assessment methodology. We found that existing comparative LCAs offered problematic comparisons of paper and digital media for two reasons — the stark material differences between ICT products and paper products, and the unique characteristics of the ICT sector. We suggested that the context of the ICT sector, best captured by the concept of “Moore's Law”, will continuously impede the ability of the LCA methodology to measure ICT products. -- Highlights: • We review the LCA research that compares paper and digital media. • We contrast the comparative LCAs with LCAs that examine only digital products. • Stark differences between paper and digital media weakens LCA findings. • Digital products in general challenge the LCA method's reliability. • Continuous innovation and global nature of digital products impedes LCA methodology.

54 ENVIRONMENTAL SCIENCES↗

D-DMTD: Digital Dual Mixer Time Difference

The digital design discussed in the following document is inspired by the digital dual mixer time difference circuit and based on the white paper, Digital femtosecond time difference circuit for CERN's timing system. DMTD is originally an analog technique that measures the time difference between two events with high precision using a commercial time interval counter. Our project applies this analog concept to a digital system programmed onto a Microsemi ProASIC3E FPGA (Field- Programmable Gate Array). D-DMTD is a digital system theoretically capable of measuring the time difference between two digital clock signals with very fine resolution (sub-picosecond) using a relatively low frequency counter. The system essentially acts as a digital phase detector with femtosecond time resolution. The main concern with this processing technique is its feasibility and accuracy when implemented on an FPGA. Another concern is the environmentally-induced, horizontal phase noise in the digital signals; this 'litter" jeopardizes the fidelity of the clocks and generates glitches in the signals. Thus, the majority of the work was focused on determining under what conditions the digital design performs optimally and generates the most accurate estimations for the phase shift.

42 ENGINEERING↗

Comparative Assessment of Experimental Testing of Instrument with an Embedded Digital Device Using Model-Based and Conventional Methods

The use of digital equipment has not been widespread in U.S. nuclear facilities. A major contributing factor to this situation arises from regulatory concerns about common cause failures (CCFs) stemming from the use of identical software in redundant systems, questions as to how to quantify the reliability of software-based products, validity of tools that are used for software verification and validation (V&V), and the effectiveness of software QA procedures. Compounding the concerns are sporadic incidents of digital equipment malfunctions in nuclear power plants, including lockups resulting from software memory leaks, feedwater control malfunctions due to excessive traffic on Ethernet networks, software logic errors, and other problems leading to plant trips. Additionally, the limited amount of demonstrated research and a lack of industry consensus on quantitative software reliability methodologies has hindered the widespread adoption of digital I&C in the nuclear industry. In a recent Regulatory Issue Summary (RIS), the U.S. Nuclear Regulatory Commission (NRC) identified concerns about the impact of greater use of instrumentation and control (I&C) equipment with an embedded digital device (EDD) [1]. Specifically, the NRC staff states that increased use of such devices “may increase a facility’s vulnerability to a CCF” (i.e., common-cause failure). The prevailing NRC guidance regarding software CCF (SCCF) identifies two design attributes that are acceptable for eliminating CCF concerns: (1) diversity or (2) testability (specifically, 100% testability). Either solution can result in high costs and remaining licensing uncertainty (i.e., how much diversity is enough? how to ensure test coverage of every possible sequence of device states?). Consequently, many utilities and reactor designers have limited or avoided more extensive use of digital technology to minimize licensing, scheduling, and financial risk. Without development of cost effective qualification methods to satisfy regulatory requirements and address the potential for CCF vulnerability associated with EDDs, the nuclear power industry may not be able to realize the benefits of digital technology achieved by other industries. In order to address these challenges, the U.S. Department of Energy (DOE) is sponsoring this research to assess the prospect of CCF in digital I&C equipment. The purpose of the current research is to develop an effective approach employing science-based methods to resolve concerns about CCF vulnerability that serve to inhibit deployment of advanced instrumentation (e.g., sensors, actuators, microcontrollers) with EDDs in nuclear power applications. The research objectives address the challenge of establishing high levels of safety and reliability assurance needed for the qualification of EDDs (e.g., microprocessors, programmable logic devices) that are subject to software design faults, complex failure modes, and CCF vulnerability. Specific objectives are: (1) assess the regulatory context for treatment of CCF vulnerability a graded approach to their qualification, (3) develop and extend model-based testing methods to enable effective demonstration of whether devices are subject to CCF, which may arise from vulnerabilities introduced at any stage of the design lifecycle, (4) establish a cost-effective testing framework that incorporates automation and test scenario prioritization, and (5) demonstrate the qualification approach through selection and testing of candidate digital device(s). This report documents an assessment of the results from experimental testing of a representative instrument with an embedded digital device. The experiment serves as a proof-of-concept demonstration of a model-based testing (MBT) framework. The objective of MBT is to ensure that an EDD undergoes suitably comprehensive testing to establish that it is not subject to SCCF. The approach by which MBT accomplishes this objective is through development and application of an effective test suite that provides the appropriate coverage to detect the full range of postulated faults that may arise at the requirements, design, and code (implementation) level of the EDD software. The findings of the experiment involve the application of the MBT framework by Ohio State University (OSU) through testing of the selected demonstration instrument (i.e., the prototype smart pressure sensor developed by Virginia Commonwealth University, VCU). In addition, the experiment findings also involve application of a more conventional black-box testing approach that serves as a baseline against which the MBT methodology can be compared. The primary outcome documented in this report is the comparative analysis of the capabilities demonstrated for each method. The results of the analysis demonstrate clear benefits that arise from the MBT methodology. The comparison indicates greater effectiveness from the more comprehensive evidence available through MBT and enhanced efficiency achieved through automation within the MBT framework. The structure of the report addresses the approach and application of each test method as well as the comparative analysis of the experimental results. Chapter 2 gives a summary overview of the demonstration approach. Chapter 3 covers the baseline testing and Chapter 4 documents the model-based testing. Chapter 5 describes the findings of the comparative analysis and presents the conclusions that can be drawn about the effectiveness and efficiency of the MBT methodology.

47 OTHER INSTRUMENTATION↗

Building Initial Dynamic System Models for Digital Twins of the Cryogenic Moderator System at the ORNL Spallation Neutron Source

This work describes the initial development of dynamic system models of the cryogenic moderator system (CMS) of the Spallation Neutron Source (SNS) at ORNL as a part of the ORNL LDRD funded project Building TRANSFORM to Accelerate Digital Twin Applications for Nuclear Systems, LOIS 10563. The goal of the work is to start the dynamic system modeling effort with the end goal of using them for real-time applications as digital twins. The CMS is a cryogenic liquid hydrogen flow loop that provides moderation of the neutrons that are generated by the SNS. For optimal neutron production, the CMS needs to maintain a steady and controlled density of cryogenic hydrogen in the moderator section thus requiring precise temperature and pressure control. Due to the varied time scales and system characteristics, control of the system is complex, and diagnostics are also difficult. Difficulty in accessing the flow loop during operations, limited instrumentation and unknown design details of the equipment combine to make the case for having sophisticated digital twin models of the system. Operationally the CMS also provides a strong use case for digital twins due to the constant need of optimization and for troubleshooting/diagnostics. The large amount of data collected which are freely available for using in building the model and verifying and validating the model also makes it a great candidate for a proof-of-concept for digital twins. The project extends ORNL's capacity of development and implementation of the open-source dynamic system modeling tool TRANSFORM for engineering design and digital twin/real-time applications. Specific system configuration data for the CMS have been gathered and an initial dynamic model was created in the TRANSFORM library using Dymola as the solution platform. Models of increasing complexity are created to demonstrate the need for a multi-layered approach in digital twin modeling depending on the scale and phenomena being focused on. The dynamic modeling is shown to bring the dynamic operational aspects to the design process for systems as well as serve as a digital twin to the hardware and allow for models to be tuned and compared against real time operational data. These aims should help to push forward strategic goals of application of digital twins and increase the impact of ORNL systems modeling capabilities with TRANSFORM/Modelica for various advanced energy systems.

42 ENGINEERING↗

The Digital Assurance for High Consequence Systems (DAHCS) Mission Campaign Whitepaper

The DAHCS (pronounced “Dax”) MC is a 7-year, $\$$45 million research portfolio within Sandia’s Laboratory Directed Research and Development program. The DAHCS MC arose in response to a great need: to ensure that the use of digital technologies does not weaken our nation’s high consequence systems. Digital technologies offer many benefits in speed, cost, and flexibility, and we seek to reap those benefits without introducing new system failures. However, digital technologies cannot be evaluated the same way as analog technologies. Initiatives across the nation highlight the capability gap that prevents efficient, effective digital assurance. The Challenge Today’s digital assurance tools, techniques, and methods are inadequate to confidently characterize, assess, and manage digital risk; they are ad hoc, slow, costly, and rarely scalable to increasingly complex digital technologies. The rapidly evolving cyber threat landscape exacerbates this problem because digital assurance now must secure against digital risks now and in the future, including those introduced by rapidly evolving technologies, adversaries, and systems.

97 MATHEMATICS AND COMPUTING↗

Feasibility Testing of Delayed Scintillator Screens for Indirect Digital Neutron Radiography of Irradiated Nuclear Fuel

Neutron radiography provides information about the internal condition of irradiated nuclear fuels. Traditionally, neutron radiography of highly radioactive irradiated nuclear fuels has been done with film using indirect radiography methods.[1] While indirect film neutron radiography is insensitive to gamma radiation from radioactive samples, it is a time-consuming and labor-intensive process. Digital neutron radiography requires a fraction of the time to produce a neutron radiograph compared to film-based processes. However, electronic components of digital radiography systems can easily be damaged by gamma radiation, which typically precludes use of digital systems for examination of highly radioactive objects, though recent work has demonstrated that some digital neutron radiography systems can indeed directly examine such samples.[2,3] This paper describes experiments performed using a hybrid transfer-digital method with an activated scintillator screen that can record an image that is subsequently read by a digital camera. The screens used in this study use a dysprosium neutron converter that records a latent image in the form of activation while in a neutron beam, then is physically transported away from the beam and sample to a digital camera elsewhere to record the image while the activated dysprosium decays and the adjacent scintillator produces light from interactions with the decay radiation. This approach could accelerate radiographic examination of irradiated nuclear fuels compared to the current transfer method with film. Current indirect imaging infrastructure was modified and augmented with a digital system. A digital neutron radiograph of a highly-radioactive irradiated nuclear fuel pins was produced in ~20 minutes, which is a significant improvement compared to the current process that takes almost a full day to produce a radiograph.

99 GENERAL AND MISCELLANEOUS↗

Reliability Assessment of Safety-Critical Network Communication in a Digitalized Nuclear Power Plant

In analog instrumentation and control (I and C) systems for nuclear power plants (NPPs), most connections are comprised of hardwired point-to-point types. Since they are based on analog technologies, they are fragile to noise and require analog-to-digital conversion time. Therefore, many NPPs have adopted communication network for the exchange of safety-critical data between programmable logic controllers (PLCs) in digital I and C systems to effectively accommodate a huge number of field controllers. However, the primary issue of digital network communication in a safety-critical system involves potential hazards, such as partial or total loss of communication between PLCs, which may result in a failure of safety critical signal generation when it is needed. Therefore, the probability that a safety-critical system in digitalized NPP becomes unsafe due to a network failure must be evaluated to quantify the risk of digital I and C system. In Korea, the Engineered Safety Feature-Component Control System (ESF-CCS) was developed as one of the digital safety-critical system in Advanced Power Reactor- 1400 (APR-1400). The function of a digital engineered safety feature (ESF) actuation system and field actuator controllers of conventional NPPs are performed by the ESF-CCS. In this system, safety-critical network, High Reliable- Safety Data Network (HR-SDN), was employed for the safety-critical data transmission from group controllers (GCs) to loop controllers (LCs). In this study, a framework for assessing the reliability of a HR-SDN network communication between GCs and LCs in the ESF-CCS in addition to a fault-tree model for ESF components considering network failure between GCs and LCs were developed to assess the plant risk effect of a newly developed digitalized ESF-CCS. Based on the case studies and cut set analysis, the risk effect of network failure on plant risk and the important risk contributors of network failure were quantitatively addressed. A framework for identifying the potential hazardous states of network communication in the ESFCCS was proposed. In addition, a fault-tree model for network communication failure was developed to estimate the risk effects of network failure between the GCs and LCs on ESF-CCS signal failure. The developed fault-tree model was then applied to several case studies. The fault-tree model of ESF-CCS signal failure for ESF components required for various mitigation actions regarding NPP DBAs was designed by considering the identified hazardous states of network failure that would result in a failure to provide input signals to the corresponding LC. As a sensitivity study, three case studies were performed based on the periodic test methods for hardware components in HR-SDN module and their test intervals in this study. The quantitative results for three case studies demonstrated that the probability of overall network communication failure, which was calculated as the sum of the failure probability associated with each failure cause, contributed up to 1.58% on the Small-LOCA CD frequency. The results also revealed the important basic events related to network failure in the case studies which included CCF of hardware and software in HR-SDN module. This study is expected to provide insight into the development of the fault-tree model for the network failure in digital I and C system and into the quantification of the risk effect of network failure for safety-critical data transmission in NPPs. As a further study, the risk effects of network failure in the ESF-CCS on the plant risk can be estimated in a more detailed manner by analyzing the failure modes and causes in a sub-component level and the fault detection coverage of the fault tolerance techniques for network failure implemented in ESF-CCS after the detailed configuration of ESF-CCS is decided. In terms of the failure of manual ESF actuation, the relationship among the human action failures must be investigated to consider multiple human error condition since ESF-CCS provides multiple manual actuation to assure the diversity of the system. Since the conventional HEP method cannot accommodate the multiple conditions in a fault tree, condition-based human reliability assessment (CBHRA) method or the dynamic human reliability modeling approach can be applied to include a complex relationship among the automated safety signal generation and the human operator's manual actuation, avoiding the optimistic estimation of HEP of the human action failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Blocker-tolerant and high-sensitivity $Δ$\!$Σ$ correlation digitizer for radar and coherent receiver applications

In this study, a coherent subsampling digitizer for pulsed Doppler radar systems is proposed. Prior to transmission, the radar system modulates the RF pulse with a known pseudorandom binary phase shift keying (BPSK) sequence. Upon reception, the radar digitizer uses a programmable sample-and-hold circuit to multiply the received waveform by a properly time-delayed version of the known a priori BPSK sequence. This operation demodulates the desired echo signal while suppressing the spectrum of all in-band noncorrelated interferers, making them appear as noise in the frequency domain. The resulting demodulated narrowband Doppler waveform is then subsampled at the IF frequency by a delta-sigma modulator. Because the digitization bandwidth within the delta-sigma feedback loop is much less than the input bandwidth to the digitizer, the thermal noise outside of the Doppler bandwidth is effectively filtered prior to quantization, providing an increase in signal-to-noise ratio (SNR) at the digitizer's output compared with the input SNR. In this demonstration, a delta-sigma correlation digitizer is fabricated in a 0.18-μm CMOS technology. The digitizer has a power consumption of 1.12 mW with an IIP3 of 7.5 dBm. The digitizer is able to recover Doppler tones in the presence of blockers up to 40 dBm greater than the Doppler tone.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Early implementation of digital upgrades on simulators - 347

An important aspect of successful Nuclear Power Plant (NPP) digital control system upgrade projects is to upgrade the Operator Training Simulator (OTS) or a related Engineering Simulator (ES), prior to installation of the Distributed Control System (DCS) on the plant allowing for early testing of the digital controls/HMI and for early training of the plant operators while maintaining OTS configuration management (i.e. OTS in sync with the plant's current design). Experience has shown that early implementation of digital upgrades on the OTS and/or an ES can reduce plant startup duration (related to digital systems commissioning) and ensure operators are proficient with the new digital systems to ensure safe and reliable plant operation. Including simulators in the design process offers many benefits including early identification of design deficiencies, testing deficiency fixes, developing and validating plant procedures and supporting human factors engineering, to name a few. Implementing digital upgrades on the OTS is also a regulatory requirement driven by the ANSI/ANS-3.5-2009 standard (Nuclear Power Plant Simulators for Use in Operator Training and Examination) if the new DCS affects actions to be taken by the plant operator in the main control room. This paper presents the benefits of implementing digital upgrades on the OTS and/or ES prior to plant implementation. The various simulator implementation strategies (stimulation, emulation, simulation or a hybrid solution) and selection factors are discussed. The paper also covers four (4) case studies demonstrating how digital upgrades can be implemented on simulators. The first case study covers the implementation of a Siemens offgas Programmable Logic Controller (PLC) system on the Enrico Fermi OTS (Michigan). The second case study covers the implementation of a GE main generator excitation system on the Cernavoda OTS (Romania). The third case study covers the implementation of a Siemens main feedwater control system on the Callaway OTS and ES (Missouri). The final case study covers the implementation of the non-safety related and safety related DCS on the Nuclear New Build (NNB) Hongyanhe Phase I dual-purpose OTS/ES (China). (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Three-Tier Incremental Approach for Development of Smart Corridor Digital Twins

Development of an arterial smart corridor digital twin requires the integration of real time data streams, data storage, and simulation model execution. This process may be complex, time consuming, and susceptible to errors. To aid in smart corridor digital twin development this paper seeks to provide a framework, best practices, and development guidance. As such, a three-tier incremental approach to smart corridor digital twin development is presented. The paper highlights practical issues in digital twin construction along with key data challenges based on experiences from the development of digital twins for two large Smart Corridor deployments, one in Chattanooga, Tennessee, and the other in Atlanta, Georgia. The presented three-tier incremental approach includes: 1) development of a prepopulated offline simulation, 2) development of a pseudo digital twin that is driven by archived data, and 3) integration of real time data streams to create the online digital twin model. The three-tiered approach facilitates conducting multiple trials and scenarios with increasing complexity, allowing for incremental error processing and updating of the digital twin.

Saroj, Abhilasha↗

Estimation of breast percent density in raw and processed full field digital mammography images via adaptive fuzzy c-means clustering and support vector machine segmentation

Purpose: The amount of fibroglandular tissue content in the breast as estimated mammographically, commonly referred to as breast percent density (PD%), is one of the most significant risk factors for developing breast cancer. Approaches to quantify breast density commonly focus on either semiautomated methods or visual assessment, both of which are highly subjective. Furthermore, most studies published to date investigating computer-aided assessment of breast PD% have been performed using digitized screen-film mammograms, while digital mammography is increasingly replacing screen-film mammography in breast cancer screening protocols. Digital mammography imaging generates two types of images for analysis, raw (i.e., 'FOR PROCESSING') and vendor postprocessed (i.e., 'FOR PRESENTATION'), of which postprocessed images are commonly used in clinical practice. Development of an algorithm which effectively estimates breast PD% in both raw and postprocessed digital mammography images would be beneficial in terms of direct clinical application and retrospective analysis. Methods: This work proposes a new algorithm for fully automated quantification of breast PD% based on adaptive multiclass fuzzy c-means (FCM) clustering and support vector machine (SVM) classification, optimized for the imaging characteristics of both raw and processed digital mammography images as well as for individual patient and image characteristics. Our algorithm first delineates the breast region within the mammogram via an automated thresholding scheme to identify background air followed by a straight line Hough transform to extract the pectoral muscle region. The algorithm then applies adaptive FCM clustering based on an optimal number of clusters derived from image properties of the specific mammogram to subdivide the breast into regions of similar gray-level intensity. Finally, a SVM classifier is trained to identify which clusters within the breast tissue are likely fibroglandular, which are then aggregated into a final dense tissue segmentation that is used to compute breast PD%. Our method is validated on a group of 81 women for whom bilateral, mediolateral oblique, raw and processed screening digital mammograms were available, and agreement is assessed with both continuous and categorical density estimates made by a trained breast-imaging radiologist. Results: Strong association between algorithm-estimated and radiologist-provided breast PD% was detected for both raw (r= 0.82, p < 0.001) and processed (r= 0.85, p < 0.001) digital mammograms on a per-breast basis. Stronger agreement was found when overall breast density was assessed on a per-woman basis for both raw (r= 0.85, p < 0.001) and processed (0.89, p < 0.001) mammograms. Strong agreement between categorical density estimates was also seen (weighted Cohen's {kappa}{>=} 0.79). Repeated measures analysis of variance demonstrated no statistically significant differences between the PD% estimates (p > 0.1) due to either presentation of the image (raw vs processed) or method of PD% assessment (radiologist vs algorithm). Conclusions: The proposed fully automated algorithm was successful in estimating breast percent density from both raw and processed digital mammographic images. Accurate assessment of a woman's breast density is critical in order for the estimate to be incorporated into risk assessment models. These results show promise for the clinical application of the algorithm in quantifying breast density in a repeatable manner, both at time of imaging as well as in retrospective studies.

60 APPLIED LIFE SCIENCES↗