Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct electron detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Research progress in radiation detectors, pattern recognition programs, and radiation damage determination in DNA

The radiological implications of statistical variations in energy deposition by ionizing radiation were investigated in the conduct of the following experiments: (1) study of the production of secondary particles generated by the passage of the primary radiation through bone and muscle; (2) the study of the ratio of nonreparable to reparable damage in DNA as a function of different energy deposition patterns generated by X rays versus heavy fast charged particles; (3) the use of electronic radiography systems for direct fluoroscopic tomography and for the synthesis of multiple planes and; (4) the determination of the characteristics of systems response to split fields having different contrast levels, and of minimum detectable contrast levels between the halves under realistic clinical situations.

Baily, N. A.↗

Characterization of the corrosion resistance of several alloys to dilute biologically active solutions

Sulfate reducing bacteria and acid producing bacteria/fungi detected in hygiene waters increased the corrosion rate in aluminum alloy. Biologically active media enhanced the formation of pits on metal coupons. Direct observation of gas evolved at the corrosion sample, coupled with scanning electron microscopy (SEM) and energy dispersive x-ray analysis of the corrosion products indicates that the corrosion rate is increased because the presence of bacteria favor the reduction of hydrogen as the cathodic reaction through the reaction of oxygen and water. SEM verifies the presence of microbes in a biofilm on the surface of corroding samples. The bacterial consortia are associated with anodic sites on the metal surface, aggressive pitting occurs adjacent to biofilms. Many pits are associated with triple points and inclusions in the aluminum alloy microstructure. Similar bacterial colonization was found on the stainless steel samples. Fourier transform Infrared Spectroscopy confirmed the presence of carbonyl groups in pitted areas of samples exposed to biologically active waters.

Walsh, Daniel W.↗

Spectroscopic Chemical Analysis Methods and Apparatus

This invention relates to non-contact spectroscopic methods and apparatus for performing chemical analysis and the ideal wavelengths and sources needed for this analysis. It employs deep ultraviolet (200- to 300-nm spectral range) electron-beam-pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor lightemitting devices, and hollow cathode metal ion lasers. Three achieved goals for this innovation are to reduce the size (under 20 L), reduce the weight [under 100 lb (.45 kg)], and reduce the power consumption (under 100 W). This method can be used in microscope or macroscope to provide measurement of Raman and/or native fluorescence emission spectra either by point-by-point measurement, or by global imaging of emissions within specific ultraviolet spectral bands. In other embodiments, the method can be used in analytical instruments such as capillary electrophoresis, capillary electro-chromatography, high-performance liquid chromatography, flow cytometry, and related instruments for detection and identification of unknown analytes using a combination of native fluorescence and/or Raman spectroscopic methods. This design provides an electron-beampumped semiconductor radiation-producing method, or source, that can emit at a wavelength (or wavelengths) below 300 nm, e.g. in the deep ultraviolet between about 200 and 300 nm, and more preferably less than 260 nm. In some variations, the method is to produce incoherent radiation, while in other implementations it produces laser radiation. In some variations, this object is achieved by using an AlGaN emission medium, while in other implementations a diamond emission medium may be used. This instrument irradiates a sample with deep UV radiation, and then uses an improved filter for separating wavelengths to be detected. This provides a multi-stage analysis of the sample. To avoid the difficulties related to producing deep UV semiconductor sources, a pumping approach has been developed that uses ballistic electron beam injection directly into the active region of a wide bandgap semiconductor material.

Hug, William F.↗

Cosmological constraints on dark matter interactions with ordinary matter

Dark matter interactions with electrons or protons during the early Universe leave imprints on the cosmic microwave background and the matter power spectrum, and can be probed through cosmological and astrophysical observations. These interactions lead to momentum and heat exchange between the ordinary and dark matter components, which in turn results in a transfer of pressure from the ordinary to the dark matter. We explore these interactions using a diverse suite of data: cosmic microwave background anisotropies, baryon acoustic oscillations, the Lyman-α forest, and the abundance of Milky-Way subhalos. We derive constraints using model-independent parameterizations of the dark matter–electron and dark matter–proton interaction cross sections and map these constraints onto concrete dark matter models. Our constraints are complementary to other probes of dark matter interactions with ordinary matter, such as direct detection, big bang nucleosynthesis, various astrophysical systems, and accelerator based experiments. They exclude sufficiently large cross sections for a large range of dark matter masses, which cannot be accessed by direct-detection experiments due to the overburden from the Earth’s atmosphere or crust.

Manuel A. Buen-Abad↗

Detection of CO Cameron band emission in comet P/Hartley 2 (1991 XV) with the Hubble Space Telescope

Ultraviolet (UV) spectra of comet P/Hartley 2 (1991 XV) taken with the Faint Object Spectrograph (FOS) on the Hubble Space Telescope (HST) in 1991 September reveal several bands of the Cameron system of CO (a 3 Pi-X 1 Sigma). These band are most likely due to 'prompt' emission from CO2 and, thus, provide a direct tracer of the CO2 abundance in the nucleus. Photodissociative excitation of CO2 is probably the largest contributor to the Cameron band emission, but significant contributions from electron impact excitation of CO, electron impact dissociation of CO2, and dissociative recombination of CO2(+), are also possible. Using our estimate that photodissociative excitation is responsible for approximately 60% of the total excitation of the Cameron system, we derive Q(sub CO2) approximately 2.6 x 10(exp 27) molecules/s, which implies CO2/H20 approximately 4%. If all of the Cameron band emission is due to photodissociative excitation, then CO2/H2O = 7 +/- 2%. For the largest possible contributions from the other excitation mechanisms considered, the CO2 abundance could be as a small as aproximately 2-3%. We did not detect CO Fourth Positive Group emission in our data and derive an upper limit of CO/H2O less than or equal to 1% (3 sigma) for CO coming directly from the nucleus. Comparison of the relative CO2 and CO abundances in P/Hartley 2 to those in P/Halley (CO2/H2O approximately 3%-4%, CO/H20 approximately 4% for the nucleus source) indicates that selective devolatilization of the nucleus may have occurred for P/Hartley 2. A relatively large CO2/CO ratio (i.e., approximately greater than 1) seems to be a common property of cometary nuclei. Since gas phase chemistry, in either the solar nebula or the interstellar medium (ISM), appears incapable of producing large relative CO2 abundances, the CO2 in cometary nuclei is probably produced either by UV and/or cosmic ray irradiation of ISM grains prior to the formation of the Solar System, or by condensation fractionation in the solar nebula.

Weaver, H. A.↗

Magnetotail electric fields observed from lunar orbit

Direct observations of convection electric fields in the earth's magnetotail are reported. The electric fields have been measured from lunar orbit by detection of the E x B/B-squared drift displacement of low-energy electrons at the limb of the moon. It is found that electric fields range in magnitude from a value less than or equal to 0.02 mV/m, the limit of sensitivity of the method, to 2 mV/M. The typical value is 0.15 mV/M, and the corresponding convection velocity is 15 km/s. The sense of the electric field is almost always dawn to dusk. The electric field is often variable on a time scale of hours and sometimes minutes. The observations indicate that the electric field is not uniform across the magnetotail. If it is assumed that the typical measured electric-field value represents an average over the inhomogeneities, the potential drop across the entire tail is of the order of 40 kV.

Mccoy, J. E.↗

Acceleration of H, He, and heavy ions observed in the magnetosheath, magnetotail, and near-by interplanetary space

Pulses of electrons and ions composed of H, He, and heavier elements were observed in the magnetosheath, magnetotail, and near-by interplanetary space. From the spatial positions where these particles were detected and the ion flow directions, it is concluded that they were accelerated at the bow shock near the sub-solar point and in the near-earth region of the neutral sheet of the magnetotail.

Fan, C. Y.↗

A Hot Microflare Observed with RHESSI and HINODE

RHESSI and Hinode observations of a GOES B-class flare are combined to investigate the origin of 15 MK plasma. The absence of any detectable hard X-ray emission coupled with weak blueshifted emission lines (indicating upward velocities averaging only 14 km/s) suggests that this was a result of direct heating in the corona, as opposed to nonthermal electron precipitation causing chromospheric evaporation. These findings are in agreement with a recent hydrodynamical simulation of microflare plasmas that found that higher temperatures can be attained when less energy is used to accelerate electrons out of the thermal distribution. In addition, unusual redshifts in the 2 MK Fe xv line (indicating downward velocities of approx.14 km/s) were observed cospatial with one of the flare ribbons during the event. Downflows of such high-temperature plasma are not predicted by any common flare model.

Milligan, Ryan O.↗

Ground and Space-Based Measurement of Rocket Engine Burns in the Ionosphere

On-orbit firings of both liquid and solid rocket motors provide localized disturbances to the plasma in the upper atmosphere. Large amounts of energy are deposited to ionosphere in the form of expanding exhaust vapors which change the composition and flow velocity. Charge exchange between the neutral exhaust molecules and the background ions (mainly O+) yields energetic ion beams. The rapidly moving pickup ions excite plasma instabilities and yield optical emissions after dissociative recombination with ambient electrons. Line-of-sight techniques for remote measurements rocket burn effects include direct observation of plume optical emissions with ground and satellite cameras, and plume scatter with UHF and higher frequency radars. Long range detection with HF radars is possible if the burns occur in the dense part of the ionosphere. The exhaust vapors initiate plasma turbulence in the ionosphere that can scatter HF radar waves launched from ground transmitters. Solid rocket motors provide particulates that become charged in the ionosphere and may excite dusty plasma instabilities. Hypersonic exhaust flow impacting the ionospheric plasma launches a low-frequency, electromagnetic pulse that is detectable using satellites with electric field booms. If the exhaust cloud itself passes over a satellite, in situ detectors measure increased ion-acoustic wave turbulence, enhanced neutral and plasma densities, elevated ion temperatures, and magnetic field perturbations. All of these techniques can be used for long range observations of plumes in the ionosphere. To demonstrate such long range measurements, several experiments were conducted by the Naval Research Laboratory including the Charged Aerosol Release Experiment, the Shuttle Ionospheric Modification with Pulsed Localized Exhaust experiments, and the Shuttle Exhaust Ionospheric Turbulence Experiments.

Bernhardt, P. A.↗

Direct VLBI detection of the magnetosphere surrounding the young star S1 in Rho Ophiuchi

VLBI 6-mm data are presently used to investigate the circularly polarized radio core previously identified around the young B3 star S1 in Rho Ophiuchi. The measured angular diameter and brightness temperature are found to be consistent with gyrosynchrotrom radiation emission from mildly relativistic electrons. A simple model based on a pole-on dipolar magnetic field of about 2 kG at the stellar surface suggests itself as consistent with the main observed features of the S1 magnetosphere; an important feature of the model is its taking the influence of the X-ray-emitting plasma into account. S1 may represent a new type of young stellar object, characterized by very extended magnetic fields.

Andre, Philippe↗

X-Ray Microanalysis and Electron Energy Loss Spectrometry in the Analytical Electron Microscope: Review and Future Directions

This paper reviews and discusses future directions in analytical electron microscopy for microchemical analysis using X-ray and Electron Energy Loss Spectroscopy (EELS). The technique of X-ray microanalysis, using the ratio method and k(sub AB) factors, is outlined. The X-ray absorption correction is the major barrier to the objective of obtaining I% accuracy and precision in analysis. Spatial resolution and Minimum Detectability Limits (MDL) are considered with present limitations of spatial resolution in the 2 to 3 microns range and of MDL in the 0.1 to 0.2 wt. % range when a Field Emission Gun (FEG) system is used. Future directions of X-ray analysis include improvement in X-ray spatial resolution to the I to 2 microns range and MDL as low as 0.01 wt. %. With these improvements the detection of single atoms in the analysis volume will be possible. Other future improvements include the use of clean room techniques for thin specimen preparation, quantification available at the I% accuracy and precision level with light element analysis quantification available at better than the 10% accuracy and precision level, the incorporation of a compact wavelength dispersive spectrometer to improve X-ray spectral resolution, light element analysis and MDL, and instrument improvements including source stability, on-line probe current measurements, stage stability, and computerized stage control. The paper reviews the EELS technique, recognizing that it has been slow to develop and still remains firmly in research laboratories rather than in applications laboratories. Consideration of microanalysis with core-loss edges is given along with a discussion of the limitations such as specimen thickness. Spatial resolution and MDL are considered, recognizing that single atom detection is already possible. Plasmon loss analysis is discussed as well as fine structure analysis. New techniques for energy-loss imaging are also summarized. Future directions in the EELS technique will be the development of new spectrometers and improvements in thin specimen preparation. The microanalysis technique needs to be simplified and software developed so that the EELS technique approaches the relative simplicity of the X-ray technique. Finally, one can expect major improvements in EELS imaging as data storage and processing improvements occur.

Goldstein, J. I.↗

Gamma ray polarimetry

Spectroscopic instruments currently being proposed may possess polarimetric capabilities which sould be nurtured and enhanced to permit characterization of basic emission mechanisms which are impossible using other techniques. Compton scattering and pair production detected the polarization of high energy (E is greater than 50 keV) protons in laboratory experiments. The polarization properties of a detection system consisting of 19 germanium crystals in a closed packed array are examined and the advantages of such a detector over Thompson scattering are discussed. The possiblity of using pair production to detect polarization of high energy gamma rays, and the associated modulation factors are discussed. The central difficulty involved in using pair production polarimeters in astrophysical applications is that the typical opening of the electron or positron direction with respect to the incident photon aircitron is small, of order E/sq mc. Multiple scattering in the material used to convert the photons to an electron positron pair causes deviations in the direction of the electron and positron.

Long, K. S.↗

Fiber optic links for microwave/millimeter-wave systems

Recent advances in device technology for microwave/mm-wave (M/MMW) analog fiber-optic communication systems are surveyed, with discussion of system parameters, design optimization methods, and hardware selection and manufacturing considerations. Particular attention is given to 1-km-link systems operating at 21, 30, and 12 GHz for satellite-communication, electronic-warfare, and radar applications. The design and fabrication simplicity of direct modulation is weighed against the wide bandwidth, low distortion, and mm-wave and frequency operation advantages of external modulation. Homodyne or heterodyne coherent detection is shown to improve system S/N by 10-20 dB over conventional detection methods. Diagrams, drawings, photographs, and graphs of typical performance data are included.

Pan, J. J.↗

The EGRET high energy gamma ray telescope

The Energetic Gamma Ray Experiment Telescope (EGRET) on the Compton Gamma Ray Observatory (GRO) is sensitive in the energy range from about 20 MeV to about 30,000 MeV. Electron-positron pair production by incident gamma photons is utilized as the detection mechanism. The pair production occurs in tantalum foils interleaved with the layers of a digital spark chamber system; the spark chamber records the tracks of the electron and positron, allowing the reconstruction of the arrival direction of the gamma ray. If there is no signal from the charged particle anticoincidence detector which surrounds the upper part of the detector, the spark chamber array is triggered by two hodoscopes of plastic scintillators. A time of flight requirement is included to reject events moving backward through the telescope. The energy of the gamma ray is primarily determined by absorption of the energies of the electron and positron in a 20 cm deep NaI(Tl) scintillator.

Hartman, R. C.↗

Forecasting the arrival of fast coronal mass ejecta at Earth by the detection of 2-20 keV neutral atoms

Studies have shown that Earth passages of fast coronal mass ejections (CMEs) trigger geomagnetic storms. Early identification of fast earth-directed CME can help provide storm warnings, but detection of such by coronagraphs is extremely difficult. We suggest that energetic hydrogen atoms (EHA) between 2 and 10 keV produced during the transit phase of an Earth-directed CME by recombination between protons and electrons in the CME can travel ahead of the CME and act as harbingers of a magnetic storm. This forecasting scheme should work if enough EHA are produced, because while CMEs decelerate continuously after their ejection, the EHA fluxes produced in the initial phase of fast CMEs propagate at their initial high speeds. Model simulations support this proposed mechanism.

Hsieh, K. C.↗

Auroral ionospheric signatures of the plasma sheet boundary layer in the evening sector

We report on particles and fields observed during Defense Meteorological Satellite Program (DMSP) F9 and DE 2 crossings of the polar cap/auroral oval boundary in the evening magnetic local time (MLT) sector. Season-dependent, latitudinally narrow regions of rapid, eastward plasma flows were encountered by DMSP near the poleward boundary of auroral electron precipitation. Ten DE 2 orbits exhibiting electric field spikes that drive these plasma flows were chosen for detailed analysis. The boundary region is characterized by pairs of oppositely-directed, field-aligned current sheets. The more poleward of the two current sheets is directed into the ionosphere. Within this downward current sheet, precipitating electrons either had average energies of a few hundred eV or were below polar rain flux levels. Near the transition to upward currents, DE 2 generally detected intense fluxes of accelerated electrons and weak fluxes of ions, both with average energies between 5 and 12 keV. In two instances, precipitating ions with energies greater than 5 keV spanned both current sheets. Comparisons with satellite measurements at higher altitudes suggest that the particles and fields originated in the magnetotail inside the distant reconnection region and propagated to Earth through the plasma sheet boundary layer. Auroral electrons are accelerated by parallel electric fields produced by the different pitch angle distributions of protons and electrons in this layer interacting with the near-Earth magnetic mirror. Electric field spikes driving rapid plasma flows along the poleward boundaries of intense, keV electron precipitation represent ionospheric responses to the field-aligned currents and conductivity gradients. The generation of field-aligned currents in the boundary layer may be understood qualitatively as resulting from the different rates of earthward drift for electrons and protons in the magnetotail's current sheet.

Burke, W. J.↗

Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250

Van Amerom, Friso H.↗

Measurement of plasma temperature and density using radiation absorption

A light beam of predetermined wavelength, preferably monochromatic, is directed through a plasma to be measured. The absorption of the light by the plasma is detected for deriving an absorption coefficient of the plasma. Knowing the absorption coefficient of the plasma and independently measuring either the electron density or temperature of the plasma allows solution of an equation to derive the other unknown quantity, i.e. either electron density or temperature. In a preferred method, the absorption coefficient of the plasma is derived simultaneously for two probing light beams of substantially different predetermined wave-lengths. Knowing these two coefficients allows solution of two simultaneous equations to derive the electron density and temperature of the plasma.

Kenneth W Billman↗