Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed electrification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Advanced Electric Systems and Aerodynamics for Efficiency Improvements in Heavy Duty Trucks

The Advanced Electric Systems and Aerodynamics for Efficiency Improvements in Heavy Duty Trucks program (DE-FC26-04NT42189), commonly referred to as the AES program, focused on areas that will primarily benefit fuel economy and improve heat rejection while driving over the road. The AES program objectives were to: (1) Analyze, design, build, and test a cooling system that provided a minimum of 10 percent greater heat rejection in the same frontal area with no increase in parasitic fan load. (2) Realize fuel savings with advanced power management and acceleration assist by utilizing an integrated starter/generator (ISG) and energy storage devices. (3) Quantify the effect of aerodynamic drag due to the frontal shape mandated by the area required for the cooling system. The program effort consisted of modeling and designing components for optimum fuel efficiency, completing fabrication of necessary components, integrating these components into the chassis test bed, completing controls programming, and performance testing the system both on a chassis dynamometer and on the road. Emission control measures for heavy-duty engines have resulted in increased engine heat loads, thus introducing added parasitic engine cooling loads. Truck electrification, in the form of thermal management, offers technological solutions to mitigate or even neutralize the effects of this trend. Thermal control offers opportunities to avoid increases in cooling system frontal area and forestall reduced fuel economy brought about by additional aerodynamic vehicle drag. This project explored such thermal concepts by installing a 2007 engine that is compliant with current regulations and bears additional heat rejection associated with meeting these regulations. This newer engine replaced the 2002 engine from a previous project that generated less heat rejection. Advanced power management, utilizing a continuously optimized and controlled power flow between electric components, can offer additional fuel economy benefits to the heavy-duty trucking industry. Control software for power management brings added value to the power distribution and energy storage architecture on board a truck with electric accessories and an ISG. The research team has built upon a previous truck electrification project, formally, 'Parasitic Energy Loss Reduction and Enabling Technologies for Class 7/8 Trucks', DE-FC04-2000AL6701, where the fundamental concept of electrically-driven accessories replacing belt/gear-driven accessories was demonstrated on a Kenworth T2000 truck chassis. The electrical accessories, shown in Figure 1, were controlled to provide 'flow on demand' variable-speed operation and reduced parasitic engine loads for increased fuel economy. These accessories also provided solutions for main engine idle reduction in long haul trucks. The components and systems of the current project have been integrated into the same Kenworth T2000 truck platform. Reducing parasitic engine loading by decoupling accessory loads from the engine and driving them electrically has been a central concept of this project. Belt or gear-driven engine accessories, such as water pump, air conditioning compressor, or air compressor, are necessarily tied to the engine speed dictated by the current vehicle operating conditions. These conventional accessory pumps are sized to provide adequate flow or pressure at low idle or peak torque speeds, resulting in excess flow or pressure at cruising or rated speeds. The excess flow is diverted through a pressure-minimizing device such as a relief valve thereby expending energy to drive unnecessary and inefficient pump operation. This inefficiency causes an increased parasitic load to the engine, which leads to a loss of usable output power and decreased fuel economy. Controlling variable-speed electric motors to provide only the required flow or pressure of a particular accessory system can yield significant increases in fuel economy for a commercial vehicle. Motor loads at relatively high power levels (1-5 kW, or higher) can be efficiently provided current from high-efficiency generators or batteries with system voltages in the range of 250 to 360 volts DC (VDC). In the previous project, the electric accessories could be powered from one of three sources: an AC voltage source ('shore power'), an on-board diesel generator (auxiliary power unit), or an ISG located in the flywheel housing and driven by the main engine. The electric accessories and power sources, including the ISG, have remained in place for the current upgrade of the research platform vehicle. In this project, more emphasis has been placed on determining the best way to use the ISG to power the vehicle and accessories, thereby yielding additional value from existing hardware.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Medium Voltage Power Electronics Enabling DER and Increasing Climate Resiliency

As renewables grow to meet both increased decarbonization and electrification goals, functionality such as grid-forming capability needs to be developed. Medium-voltage power electronic-enabled interfaces for renewables and as new devices within the grid themselves are an ideal platform for implementing these functionalities.

decarbonization↗

Solar+Storage for Household Back-up Power: Implications of building efficiency, load flexibility, and electrification for backup during long-duration power interruptions [Slides]

The study analyzes the evolving role of solar+storage for home backup power during long-duration power interruptions. In particular, it evaluates how required storage sizing is impacted as homes become more efficient, flexible, and electrified. The study relies on NREL’s ResStock building modeling platform to create statistically representative distributions of the existing building stock in ten locations across the United States. It then shows how the amount battery storage required for backup power rises or falls as a series of building envelope efficiency, load flexibility, and electrification measures are applied across the building stock in each region. The study also includes sensitivities to show how backup power requirements are impacted by the timing and duration of power interruptions, and explores variation in backup power requirements across the building stock within each study location. The results demonstrate the value of pairing solar+storage with efficiency upgrades, smart home controls, and (in mild winter climates) efficient heat pump retrofits. That value comes in the form of reducing the amount of storage required and/or extending the range of interruption conditions over which a given system can provide backup power (i.e., more extreme weather and/or longer interruptions). Heat pumps in cold-weather climates can pose a challenge for solar+storage backup power, given the amount of storage required, though are a vast improvement over electric-resistance heating. Retaining existing fossil-based heating systems for occasional use during power interruptions, as either the primary or supplementary source of heat, can mitigate this challenge. Other forms of building electrification (e.g., cooking and water heating) generally have marginal impacts on backup battery sizing, given their relatively small energy demand.

14 SOLAR ENERGY↗

Packetized Energy Management: Coordinating Transmission and Distribution (Final Report)

The project Packetized Energy Management (PEM): Coordinating Transmission and Distribution was part of the ARPA-E NODES program from 2015 to 2023. The high-level goal of the project was to develop and demonstrate novel, scalable, and impactful technologies related to the coordination of networked distributed energy resources (DERs). By demonstrating responsive means by which fleets of DERs could be coordinated to enhance grid operation and reliability, the U.S. could accelerate renewable integration and electrification efforts and meet decarbonization goals.

25 ENERGY STORAGE↗

A High-Efficient Solution for Electro-Hydraulic Actuators with Energy Regeneration Capability

This paper proposes a cost-effective, robustly practical solution for a high-efficient electro-hydraulic actuator (EHA) for linear drives. The solution addresses the challenges of high costs and limited efficiency that limit the application of EHA for the electrification of many off-road vehicles. Based on a variable-speed electric motor and a low-cost technology for a fixed-displacement pump, the proposed solution is suitable for a compact implementation and it is capable of energy regeneration under overrunning load conditions. Two different architectures—an open circuit and a closed circuit one—are considered to determine the most practical and efficient configuration as well as the control features. Both architectures minimize throttling losses associated with the conventional regulation of hydraulic actuators. Actuator velocities below the minimum and beyond the maximum allowable pump flow rate are achieved in both architectures using a proportional valve that bypasses the pump flow. The paper describes the design methodology as well as the simulation and experimental activities performed to verify the control strategies as well as energy efficiency. Considering an EHA system of about 20 kW, a complete efficiency map of the system is determined for all the possible four quadrants of operation thus including both resistive and overrunning loads, where energy recuperation is implemented. Simulation and experimental results show that the energy efficiency of the hydraulic systems can reach 84.7% in resistive phases. In assistive phases, the hydraulic system can recover up to 81.8% of the actuator energy. Here, the comparison between open-circuit and closed-circuit structures shows the advantages of the former in terms of energy efficiency. The proposed solution is suitable for electrified hydraulic actuation systems, in both industrial and mobile applications. With the advantages of the low cost of the hydraulic unit and high energy efficiency, it is particularly suitable for mobile applications such as construction machines, that are recently experiencing a significant electrification trend.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electric and Hydraulic Propel Torque Modulation for a Compact Track Loader With the Hybrid Hydraulic Electric Architecture (HHEA)

Abstract The Hybrid Hydraulic Electric Architecture (HHEA) has previously been proposed for off-highway vehicles to reap the efficiency and controllability benefits of electrification without needing very large electric motors. This is achieved with the use of a set of selectable common pressure rails to transmit the majority of power and small electric motors to modulate that power. Previous work has shown significant energy savings for the work circuits of a variety of machines. In this paper, the energy saving potential of HHEA for the propel circuit of a compact track loader is studied. The ports of the track hydraulic motors are selectably connected to the common pressure rails, and instead of using the electric assist motors to buck/boost pressure, as in HHEA for linear actuators, small electric assist motors are used to add/subtract torque directly. The interplay between the torque limits of the electric motors and the ability of the hydraulic motor to vary displacements is studied, along with the effect these factors have on energy saving potential. It is found that the ability to vary the displacement of the hydraulic motor allows for: more efficient electric motor operating conditions, reduced electric torque requirement, and reduced pressure rail switching events. All three of these advantages can be achieved at once using variable displacements; but trade-offs exist between these advantages (i.e. improved efficiency can be achieved at the expense of a larger electric torque requirement). Overall, the HHEA can reduce energy consumption by ∼ 36% compared to the stock machine, depending on the hydraulic motor’s ability to vary displacements, and assuming the electric motor torque is limited to 20% of that required in a direct electrification scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An OpenStreetMaps based tool to study the energy demand and emissions impact of electrification of medium and heavy-duty freight trucks

In this paper, we present the mathematical formulation of an OpenStreetMaps (OSM) based tool that compares the costs and emissions of long-haul medium and heavy-duty (M&HD) electric and diesel freight trucks, and determines the spatial distribution of added energy demand due to M&HD EVs. The optimization utilizes a combination of information on routes from OSM, utility rate design data across the United States, and freight volume data, to determine these values. In order to deal with the computational complexity of this problem, we formulate the problem as a convex optimization problem that is scalable to a large geographic area. In our analysis, we further evaluate various scenarios of utility rate design (energy charges) and EV penetration rate across different geographic regions and their impact on the operating cost and emissions of the freight trucks. Our approach determines the net emissions reduction benefits of freight electrification by considering the primary energy source in different regions. Such analysis will provide insights to policy makers in designing utility rates for electric vehicle supply equipment (EVSE) operators depending upon the specific geographic region and to electric utilities in deciding infrastructure upgrades based on the spatial distribution of the added energy demand of M&HD EVs. To showcase the results, a case study for the U.S. state of Texas is conducted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovative Thermal Strategies: Electrification's Best Friend

Because transportation and heat are the most significant contributors to greenhouse gas (GHG) emissions in the northern U.S., electrification of transport and heat are prominent elements of many decarbonization plans, such as that of New York State (NYS). A key challenge is then to decarbonize the electric supply and distribution system ("the grid") that supplies electricity, a process colloquially known as "greening the grid", so that the saved direct carbon emissions are not offset by additional indirect emissions from electrical generation on the grid. Applying this "simple" decarbonization plan to locations with high winter heating loads and modest renewable resources is challenging. Understanding the impact of thermal system design to grid demands in these locations and the related marginal power source for electrification options is critical to allocating proper resources to solve decarbonization challenges and quantifying the resultant carbon emissions impact.

battery storage↗

Integrated Distribution Planning

The contemporary distribution planning landscape is comprised of an increasing number of factors that require integration into the engineering of the modern electric grid. Expectations for electric utilities to accommodate heightened awareness of stakeholders' interest in things like decarbonization, resilience and equity are growing. As these interests are formed into objectives, many jurisdictions will experience increasing levels of load modifying technologies like DER, building and industrial electrification and electric vehicles which prove not only to challenge the capabilities of the grid; but the processes by which planning for it is traditionally done. Other related factors that strain the conventional distribution planning mold are the swelling amount and sources of data associated with these technologies and the need it creates for improved capabilities in the processes and tools that manage it. As the complexity of the distribution system expands, so will the distribution system's effects on the transmission and generation systems that it is a part of. Forecasting distribution system load and DER are examples of areas where this complexity will manifest, and harmonizing distribution forecasting with transmission and generation forecasting requires higher amounts of intentionality as these typically separate processes become a solitary one. Of course, core activities do not cease as a utility begins to integrate these other factors, and in this webinar we explore specifics of how distribution planning can be expected to evolve as progress towards Integrated Distribution System Planning is made.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Demand-Side Grid (dsgrid) Model

This presentation gives a high-level overview of the recently published demand-side grid (dsgrid) model documentation. The general modeling philosophy and technical approach of dsgrid is described, as is an initial data set covering 2012 contiguous United States (CONUS) electricity demand. The initial data set describes about 80% of electrical load at an hourly level by county, subsector and end use. Coarser models and data sets are used to describe the remainder. Model residuals are calculated at different levels of aggregation by leveraging historical electricity sector data and a model of 2012 distributed generation. Overall, the dsgrid model has been developed to support analysis of future load scenarios, including interactive effects between energy efficiency, electrification, demand response, renewable energy, battery energy (or other forms of) storage, and future grid conditions broadly construed. Planned future work includes the development of future load scenarios and physically realistic estimates of the flexible load resource.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Diesel-like Fuels, Combustion, and Emissions

The need to reduce the carbon footprint from medium- and heavy-duty diesel engines is clear; low-carbon biofuels are a powerful means to achieve this. Liquid fuels are rapidly deployed because existing infrastructure can be utilized for their production, transport, and distribution. Their impact is unique as they can decrease the greenhouse gas (GHG) emissions of existing vehicles and in applications resistant to electrification. However, introducing new diesel-like bio-blends into the market is very challenging. At a minimum, it requires a comprehensive understanding of the life-cycle GHG emissions of the fuels, the implications for refinery optimization and economics, the fuel’s impact on the infrastructure, the effect on the combustion performance of current and future vehicle fleets, and finally the implications for exhaust aftertreatment systems and compliance with emissions regulations. Such understanding is sought within the Co-Optima project.

02 PETROLEUM↗

Decarbonization Technology Snapshot: Heat Pump Water Heaters

Heat pump water heaters use electricity to move heat from one place to another instead of generating heat directly. In many cases they replace gas-fired water heaters and are significantly more energy efficient, reducing on-site Scope 1 emissions and often resulting in reduced total emissions.

building decarbonization↗

Grid-Enhanced, Mobility-Integrated Network Infrastructures for Extreme Fast Charging (GEMINI-XFC)

Increasing vehicle electrification will require extensive use of extreme fast charging (XFC), especially for larger vehicles. Uncoordinated XFC can create grid challenges, particularly at the distribution level. Two strategies can support widespread XFC: gold-plate the grid (i.e., upgrade all systems to enable worst-case, fully coincident loads) or use integrated planning to codesign a smart system based on advanced controls that leverage load flexibility and distributed energy resources. With the right design and control, XFC can simultaneously support both mobility and grid operations. Fully realizing the potential of XFC, however, will require unprecedented coordination among the charging infrastructure, grid, and vehicles. GEMINI-XFC combines high-fidelity grid and transport modeling at an unprecedented level of resolution and codesigns a smart system based on advanced controls that leverage load flexibility and distributed energy resources to optimize the integration of extreme fast charging (XFC) across a full regional scale with individual customer resolution.

ADVANCED PROPULSION SYSTEMS↗

Addressing Electric Aviation Infrastructure Cybersecurity Implementation

This technical report evaluates key considerations of cybersecurity systems in preparation for the electrification of both legacy and new aviation services. The objectives are to consider the landscape of components and interconnections, review sensitivities and the criticality of data and operations, and aim to understand the applicability of existing best practices or the need for new ones associated with the cybersecurity of electric charging systems for the aviation sector. Given the early stages of electric aviation deployment, developers have the opportunity to plan and integrate cybersecurity strategies into the complete electric aviation system during the initial stages of design and procurement and will benefit from employing a framework for continuous cybersecurity monitoring. This paper presents initial considerations of key cybersecurity strategies and their application to forthcoming electric aviation systems.

airports↗

Demonstrating Load-Shaping Capabilities of Cost Minimizing Heat Pump Water Heater Controls with Varying Price Profiles

Increased penetration of photovoltaics and electrification of traditionally gas appliances are exacerbating existing challenges in cost-effectively balancing electricity grid supply and demand. Decarbonization without incurring expensive transmission and distribution system capacity increases requires shifting building loads from peak demand times to peak renewable production times. Grid operators are evaluating new ways of encouraging load shifting, including using time-varying price structures to provide a financial incentive. If devices incorporate price-responsive controls, a price profile could be designed to yield a wide variety of load curves as needed to optimize grid functionality. Heat pump water heaters (HPWHs) are an ideal device for price-responsive controls because the storage tank enables them to optimize the timing of electricity consumption without impacting hot water delivery service. This paper presents work demonstrating how price-responsive controls for HPWHs can provide different load profiles, as needed to stabilize the grid, in response to different price profiles. HPWH manufacturers now include web API and CTA-2045 communication capabilities which enable sending load shaping control signals. Pilot studies and preliminary programs have utilized these capabilities with uniform control strategies to reduce 4-9 PM electricity consumption. However, no studies have developed flexible controls capable of both a) responding to constantly varying price profiles and b) customizing logic to match the needs of each HPWH. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls utilizing setpoint setting signals for fleets of HPWHs in response to varying price profiles. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of a residential, integrated HPWH manufacturer’s on-board controller. The proposed cost-reducing controls respond to constantly changing price profiles, providing the ability to change the price profile to generate load curves as needed to maintain grid stability. Preliminary simulations studying the load shaping capabilities of price-responsive controls on a fleet of 60 HPWHs have demonstrated an average of a) 135.4% increases in load during low-price periods, b) >36.8% reductions in electricity peak-price period, and c) 6.2% electricity cost savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Proactive and Reactive Thermal Comfort Behaviors

The expansion of renewable electricity generation, growing demands due to electrification, greater prevalence of working from home, and increasing frequency and severity of extreme weather events, will place new demands on the electric supply and distribution grid. Broader adoption of demand response programs (DRPs) for the residential sector may help meet these challenges; however, experience shows that occupant overrides in DRPs compromises their effectiveness. There is a lack of formal understanding of how discomfort, routines, and other motivations affect DRP overrides and other related human building interactions (HBI). This paper reports preliminary findings from a study of 20 households in Colorado and Massachusetts, US over three months. Participants responded to ecological momentary assessments (EMA) triggered by thermostat interactions and at random times throughout the day. EMAs included Likert-scale questions of thermal preference, preference intensity, and changes to 7 different activity types that could affect thermal comfort, and an opened ended question about motivations of such actions. Twelve tags were developed to categorize motivation responses and analyzed statistically to identify associations between motivations, preferences, and HBI actions. Reactions to changes in the thermal environment were the most frequently observed motivation (118 of 220 responses). On the other hand, almost half (47%) responses were at least partially motivated by non-thermal factors, suggesting limited utility for occupant behavior models founded solely on thermal comfort. Changes in activity level and clothing were less likely to be reported when EMAs were triggered by thermostat interactions, while fan interactions were more likely. Windows, shades, and portable heater interactions had no significant dependence on how the EMA was triggered. These results suggest that better understanding of motivations for HBI may improve effectiveness of demand response programs.

Pathak, Maharshi↗

In Hot Water! The Challenges and Barriers of Decarbonizing Water Heating in Multifamily Buildings: Preprint

Domestic hot water heating is responsible for 32% of the total energy consumption in multifamily buildings and offers a significant decarbonization opportunity. An extensive market assessment was conducted to understand and document key technical and economic barriers to electrification of domestic water heating in multifamily buildings throughout the U.S. Through the program, 77 interviews were conducted to understand key market drivers and technical challenges associated with electrification of water heating systems in both retrofit and new construction scenarios. Interviewees encompassed a wide range of stakeholders in the ecosystem surrounding water heating systems, including suppliers, manufacturers, designers, owners, utilities, and developers. This paper documents key interview takeaways, including an extensive list of market barriers, technical challenges, and sought-after technology attributes that can inform pertinent design criteria for electric water heating research, development, and deployment efforts. Among economics and energy efficiency features, interviewees overwhelmingly alluded to space constraints, cold air exhaust, and lack of clear guidance regarding distributed versus centralized design selections as key challenges associated with mass adoption of electric water heating. Owners and developers seek systems with minimal footprint, which maximize rentable space and profits. Moreover, distributed heat pump solutions should balance ducting costs that mitigate cold exhaust entrainment into conditioned zones. Lastly, the market needs clear guidance regarding the selection of distributed versus central electric hot water systems.

challenges of water heating electrification↗