Integration of X-point radiator divertor operation with high beta hybrid core plasmas in DIII-D
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The goal of this project was to develop a fundamental understanding of helium and hydrogen behavior in lithium, both in bulk and at interfaces with tungsten, in order to inform the design of lithium based plasma facing components for fusion devices. Over the course of the award, the project produced the first comprehensive, peer reviewed dataset describing helium energetics, migration behaviors, and defect interactions in lithium. The research demonstrated that helium behaves in ways not previously observed in any other body centered cubic (BCC) metal: its interstitial configurations are more stable than substitutional ones, and its migration barriers are extraordinarily low, in some cases more than an order of magnitude below those in tungsten or iron. These discoveries reveal that helium in lithium diffuses so rapidly that its transport may be dominated by translational motion rather than the vibrationally activated mechanisms that underpin conventional solid state diffusion. This work lays a scientific foundation for understanding gas retention, bubble formation, and wall evolution in lithium based fusion environments and provides new computational tools, most notably a newly developed Li–He interatomic potential, for advancing future modeling efforts.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Original - A slide package that summarizes research progress of 2025 summer high school internship. To be presented at an internal group presentation to all the high school interns and mentors within C200, plus potential more interested audience from INL. Revision - Based on the original LRS-approved slide package, an updated slide package and a poster were prepared with slight changes (e.g., adjusting the layout of slides and reproducing some plots for better clarity) for the interns' final showcase on August 13. The showcase will be public-facing (i.e., not limited to INL attendees).
To successfully show that fusion is an attractive energy source, the ARCTM fusion power plant will need to operate with a robust, integrated power and particle exhaust solution. To maximise ARC’s fusion power output while avoiding excessive erosion of the plasma-facing components, we will need to radiatively dissipate most of the power crossing the last-closed flux surface, injecting radiating impurities such as argon or neon to access divertor detachment. Divertor detachment will need to be integrated with a high-performance core plasma, and with efficient impurity pumping to prevent the accumulation of helium ash in the core. To access and control detachment in high-performance plasmas, we have designed ARC with up–down-symmetric divertors, with secondary X-points in long, tightly baffled outer legs. Using a core-edge modelling workflow, we predict that with this divertor design, ARC will access detachment with modest argon seeding in the divertor (c Ar,div ∼0.9%), which should have minimal impact on the core ( Z eff,core <0.5) for reasonable argon enrichment (c Ar,div /c Ar,core =6). Due to the high predicted divertor neutral pressure (p div ∼20 Pa), we predict that ARC will sufficiently pump helium to limit ash accumulation in the core (c He,core <2%) for a helium enrichment of c He,div /c He,core =0.4. ARC’s divertor design is expected to increase the stability of a detachment front in the outer divertor leg, helping to prevent divertor reattachment during smaller heat-flux transients such as scrape-off-layer filaments associated with the quasi-continuous exhaust regime. However, this buffering will not be sufficient to prevent divertor reattachment during large type-I edge-localised modes (ELMs), and as such these will need to be avoided on ARC. Experiments on SPARC will be used to select an integrated scenario which avoids or mitigates type-I-ELMs while maintaining access to detachment, good core fusion performance and sufficient impurity exhaust. SPARC experiments will also be used to finalise ARC’s divertor design, by studying the impact of magnetic and first-wall geometry on detachment stability, impurity enrichment and neutral baffling under conditions similar to those expected for ARC. In conclusion, our analysis finds that ARC will have a viable power and particle exhaust solution which is compatible with high-power operations, and this solution will be validated in experiments on SPARC.
An initial high fluence campaign was performed in WEST, in 2023, on the newly installed actively cooled tungsten divertor composed of ITER-grade monoblocks. The campaign consisted in the repetition of a 60 s long Deuterium L-mode pulse in attached divertor conditions, cumulating over 10000s of plasma exposure. A maximum deuterium fluence of approximately 5⋅1026 m−2 was reached in the outer strike point region, representative of a few high performance ITER pulses. Gross tungsten erosion inferred from visible spectroscopy shows that the most eroded plasma facing component is the inner divertor target with rates ten times larger than on the outer divertor target. The outer midplane tungsten bumpers, located a few centimeters from the plasma, show gross erosion rates two times lower than at the outer divertor. We conclude that the outer midplane bumpers have a negligible contribution to the long range tungsten migration and deposition onto the lower divertor. The cumulated gross erosion rate on the inner divertor translates in an effective gross erosion thickness of about 20μm, while it is about 2μm for the outer divertor. Strikingly, these orderings coincide with the thickness of deposits found locally on the divertor: the exposed surfaces of high field side monoblocks are covered with several tens of μm tungsten deposits, while on the lower field side, few μm thin tungsten deposits are only found on the magnetically shadowed parts of monoblocks. The strong impact of those deposits on WEST operation, namely perturbation of surface temperature measurement with infra-red thermography, and the emission of flakes causing radiative perturbation of the confined plasma, calls for anticipating similar issues in ITER. In particular, the start of research operation shall consider the definition of a divertor erosion budget in order to anticipate the formation of deleterious deposits.
Abstract Experiments performed during strongly-shaped high-power diverted negative triangularity (NT) experiments in DIII-D achieved detached divertor conditions and a transient-free edge, showcasing the potential for application of NT to a core-edge integrated reactor-like scenario and providing the first characterization of the parametric dependencies for detachment onset. Detached divertor conditions will be required in future devices to mitigate divertor heat fluxes. Access to dissipative divertor conditions was investigated via an increase in upstream density. Detachment onset at the outer strike point was achieved with H-mode level confinement H 98 − y 2 ∼ 1 and reactor-relevant normalized pressures β N ∼ 2 . Confinement degradation was observed with deeper detachment, associated with the loss of an electron temperature pedestal. Differences in geometry, radial transport, impact of cross field drifts are discussed to explain differences in access to detachment in NT discharges. Higher normalized densities, with respect to equivalent discharges in positive triangularity, were necessary to achieve detachment, partially explained by the shorter parallel connection length to the targets. The effect of cross-field particle drifts ( E × B , B × ∇ B ) on access to detachment was demonstrated by the lower upstream density needed to access detachment with ion B × ∇ B drift directed outside of the active divertor (Greenwald fraction f Gw ∼ 0.9–1.0 vs f Gw ∼ 1.3). The upstream density at detachment onset was observed to increase linearly with plasma current with ion B × ∇ B drift into the divertor, consistent with the observed narrowing of the scrape-off layer heat flux width λ q . Edge fluid simulations capture separatrix densities needed to achieve detachment in NT plasma and their dependence on drift direction. The ability to reproduce detachment dynamics in NT plasma increases the confidence in future design studies for NT divertors.
This work explores the challenges and opportunities for power exhaust control in STEP, informed by dedicated MAST-U experiments. The STEP system primarily relies on hydrogenic and argon gas injection into the divertors, compensating for transients originating in the plasma core. Fast transients (>10 Hz) that evolve too quickly for actuators to compensate must be absorbed passively; the enhanced transient buffering of the foreseen long-legged divertor provides a clear advantage over conventional geometries, as demonstrated in the MAST-U Super-X divertor. Experiments further indicate that STEP’s tight divertor baffling enables near-independent control of the upper and lower divertors. The most challenging transients are expected from power-sharing fluctuations, as MAST-U experiments observed extremely fast dynamics. Fluctuations from core pellet fuelling remain relatively benign due to the small pellet size according to simulations. Exhaust control in a reactor like STEP requires an integrated approach befitting its machine-critical nature. A predictive control element, integrated with core plasma control, allows pre-emptive preparation of the divertor for incoming transients. An observer-based diagnostic approach is foreseen to monitor the divertor in the challenging reactor environment, supported by an extended diagnostic set in the non-nuclear phase to validate the required dynamic models.
Abstract This work explores detailed power handling solutions for a class of high-field, highly-radiative negative triangularity (NT) reactors based around the MANTA concept (Rutherford et al 2024 Plasma Phys. Control. Fusion ). The divertor design is kept as simple as possible, opting for a standard divertor with standard leg length. FreeGS is used to create an equilibrium for the boundary region, prioritizing a short outer leg length of only ∼50 cm (∼40% of the minor radius). The UEDGE code package is used for the boundary plasma solution to track plasma temperatures and fluxes to the divertor targets. It is found that for P SOL = 25 MW and n sep = 0.96 × 10 20 m −3 , conditions consistent with initial core transport modeling, little additional power mitigation is necessary. For a fixed impurity fraction of just 0.13% Ne in the plasma, the peak heat flux density at the more heavily loaded outer targets falls to 7.8 MW m −2 , while the electron temperature T e remains just under 5 eV. Scans around the parameter space reveal that even at densities lower than in the primary operating scenario, P SOL can be increased up to 50 MW, so long as a slightly higher fraction of extrinsic radiator is used. With less than 1% neon (Ne) impurity content, the divertor still experiences less than 10 MW m −2 at the outer target. Design of the plasma-facing components includes a close-fitting vacuum vessel with a tungsten inner surface as well as FLiBe-carrying cooling channels fashioned into the VV wall directly behind the divertor targets. For the seeded heat flux profile, Ansys Fluent heat transfer simulations estimate that the outer target temperature remains at just below 1550 ∘ C. Initial scoping of advanced divertor designs shows that for an X-divertor, detachment of the outer target becomes much simpler, and plasma fluxes to the targets drop considerably with only 0.01% Ne content.