Search NASA⌕ Search

SEARCH · Search NASA

Results for “dose prediction methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Advanced Graphite Creep Uncertainty Analysis

Radiation damage estimation is an important component of the post irradiation analysis of the Advanced Graphite Creep (AGC) experiment. It depends primarily on the fast fluence, which is determined using well established methods of spectral adjustment. These are based on best estimates from models such as Monte Carlo N-Particle (MCNP), input cross-sections, and measured activities from flux wires in the experiment. Each of these parameters can propagate uncertainties which will affect the uncertainty in the calculated dose levels for AGC, or any experiment irradiated within a reactor. While the methods of propagating uncertainty are well-established, the final uncertainty estimates they provide are only as good as the estimates of uncertainty in the inputs on which they are based. The purpose of this work is to outline some deficiencies in the ways these input uncertainties are presently estimated, and to outline a methodology by which they can be improved. The fast fluence and radiation damage received by graphite specimens irradiated in the Advanced Graphite Creep (AGC) experiments is presently estimated using spectral adjustment methods that are based on both flux wire activity measurements, and MCNP model predictions. This work describes an ongoing effort to quantify and propagate uncertainties in inputs to the spectral adjustment process, and thereby quantify the resultant error in radiation damage (dpa) estimates. The effort is multi-faceted, and we consider the impacts of both the set of flux wires selected, and the counting process. An expanded set of flux wires is identified that provides a more comprehensive data set on the fast spectrum. To address the counting process itself, a series of round-robin measurements in several reactor metrology laboratories across the Department of Energy (DOE) complex and nuclear industry are being undertaken to refine the American Society for Testing and Materials (ASTM) standards for flux wire measurements. To address the contribution of uncertainty in the MCNP model predictions, an uncertainty quantification (UQ) tool has been developed that statistically samples the model input parameters, runs a series of cases, and assimilates the results to provide an overall uncertainty. The impact of the MCNP UQ tool results is demonstrated by re-analyzing previous AGC flux wire and irradiation data. While the expanded flux wire set obviously cannot be added to these experiments retroactively, plans for future graphite irradiations are outlined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Predictions of secondary neutrons and their importance to radiation effects inside the International Space Station

As part of a study funded by NASA MSFC to assess thecontribution of secondary particles in producing radiation damage to optoelectronics devices located on the International Space Station (IS), Monte Carlo calculations have been made to predict secondary spectra vs. shielding inside ISS modules and in electronics boxes attached on the truss (Armstrong and Colborn, 1998). The calculations take into account secondary neutron, proton, and charged pion production from the ambient galactic cosmic-ray (GCR) proton, trapped proton, and neutron albedo environments. Comparisons of the predicted neutron spectra with measurments made on the Mir space station and other spacecraft have also been made (Armstrong and Colborn, 1998). In this paper, some initial results from folding the predicted neutron spectrum inside ISS modules from Armstrong and Colborn (1998) with several types of radiation effects response functions related to electronics damage and astronaut-dose are given. These results provide an estimate of the practical importance of neutrons compared to protons in assessing radiation effects for the ISS. Also, the important neutron energy ranges for producing these effects have been estimated, which provides guidance for onboard neutron measurement requirements.

Neutrons↗

Interpretation of Ion Irradiation and Neutron Irradiation Damage in Additively Manufactured 316 Stainless Steel using Multiscale Modeling

The accelerated adoption of nuclear energy necessitates advanced manufacturing technologies, such as additive manufacturing, to meet heightened supply chain requirements and support innovative reactor technologies. Due to the unique microstructural characteristics of additively manufactured materials under distinct solidification conditions, comprehensive evaluation of their performance in reactor environments is essential. The Advanced Materials and Manufacturing Technologies program under the Department of Energy's Office of Nuclear Energy focuses on understanding the irradiation performance and damage evolution of laser powder bed fusion 316 stainless steel, with an emphasis on integrating ion and neutron irradiation data to accelerate the development and qualification of materials for advanced nuclear reactor applications. While ion irradiation is a cost- and time-effective method, modeling and simulation are required to interpret the data for the broader range of irradiation conditions encountered in advanced reactors. In fiscal year 2025, integrated multiscale modeling and simulations were conducted to assess irradiation damage in additively manufactured 316 stainless steel. Key outcomes include predictions of chromium enrichment at grain boundaries, nickel enrichment at dislocation cell walls and void surfaces, and heterogeneous void evolution under ion and neutron irradiation conditions. Cluster dynamics simulations revealed the coarsening of voids at high irradiation temperatures and the suppression of void growth by high network dislocation density, while also demonstrating significant growth and coarsening of voids and self-interstitial atom loops at low dose rates. Machine learning-accelerated atomistic simulations highlighted the impact of the local environment and chromium concentration on vacancy diffusivity, providing key insights on the influence of composition on void swelling and radiation-induced segregation. Additionally, molecular dynamics simulations demonstrated the presence of defect production bias and a significant effect of carbon content on defect cluster behavior. These combined efforts aim to predict the performance of additively manufactured materials under various reactor conditions, supporting their qualification for nuclear reactor applications by interpreting ion irradiation data. This report underscores the potential of integrated multiscale modeling to analyze ion irradiation data in the effort to accelerate the qualification of additively manufactured materials for nuclear reactor components.

316 stainless steel↗

Practical Applications of Cosmic Ray Science: Spacecraft, Aircraft, Ground-Based Computation and Control Systems, and Human Health and Safety

Three twentieth century technological developments, 1) high altitude commercial and military aircraft; 2) manned and unmanned spacecraft; and 3) increasingly complex and sensitive solid state micro-electronics systems, have driven an ongoing evolution of basic cosmic ray science into a set of practical engineering tools needed to design, test, and verify the safety and reliability of modern complex technological systems. The effects of primary cosmic ray particles and secondary particle showers produced by nuclear reactions with the atmosphere, can determine the design and verification processes (as well as the total dollar cost) for manned and unmanned spacecraft avionics systems. Similar considerations apply to commercial and military aircraft operating at high latitudes and altitudes near the atmospheric Pfotzer maximum. Even ground based computational and controls systems can be negatively affected by secondary particle showers at the Earth s surface, especially if the net target area of the sensitive electronic system components is large. Finally, accumulation of both primary cosmic ray and secondary cosmic ray induced particle shower radiation dose is an important health and safety consideration for commercial or military air crews operating at high altitude/latitude and is also one of the most important factors presently limiting manned space flight operations beyond low-Earth orbit (LEO). In this paper we review the discovery of cosmic ray effects on the performance and reliability of microelectronic systems as well as human health and the development of the engineering and health science tools used to evaluate and mitigate cosmic ray effects in ground-based atmospheric flight, and space flight environments. Ground test methods applied to microelectronic components and systems are used in combinations with radiation transport and reaction codes to predict the performance of microelectronic systems in their operating environments. Similar radiation transport codes are used to evaluate possible human health effects of cosmic ray exposure, however, the health effects are based on worst-case analysis and extrapolation of a very limited human exposure data base combined with some limited experimental animal data. Finally, the limitations on human space operations beyond low-Earth orbit imposed by long term exposure to galactic cosmic rays are discussed.

Atwell, William↗

Application of Cell Painting for chemical hazard evaluation in support of screening-level chemical assessments

‘Cell Painting’ is an imaging-based high-throughput phenotypic profiling (HTPP) method in which cultured cells are fluorescently labeled to visualize subcellular structures (i.e., nucleus, nucleoli, endoplasmic reticulum, cytoskeleton, Golgi apparatus / plasma membrane and mitochondria) and to quantify morphological changes in response to chemicals or other perturbagens. HTPP is a high-throughput and cost-effective bioactivity screening method that detects effects associated with many different molecular mechanisms in an untargeted manner, enabling rapid in vitro hazard assessment for thousands of chemicals. Here, 1201 chemicals from the ToxCast library were screened in concentration-response up to ~100 μM in human U-2 OS cells using HTPP. A phenotype altering concentration (PAC) was estimated for chemicals active in the tested range. PACs tended to be higher than lower bound potency values estimated from a broad collection of targeted high-throughput assays, but lower than the threshold for cytotoxicity. In vitro to in vivo extrapolation (IVIVE) was used to estimate administered equivalent doses (AEDs) based on PACs for comparison to human exposure predictions. AEDs for 18/412 chemicals overlapped with predicted human exposures. Phenotypic profile information was also leveraged to identify putative mechanisms of action and group chemicals. Of 58 known nuclear receptor modulators, only glucocorticoids and retinoids produced characteristic profiles; and both receptor types are expressed in U-2 OS cells. Thirteen chemicals with profile similarity to glucocorticoids were tested in a secondary screen and one chemical, pyrene, was confirmed by an orthogonal gene expression assay as a novel putative GR modulating chemical. Most active chemicals demonstrated profiles not associated with a known mechanism-of-action. However, many structurally related chemicals produced similar profiles, with exceptions such as diniconazole, whose profile differed from other active conazoles. Overall, the present study demonstrates how HTPP can be applied in screening-level chemical assessments through a series of examples and brief case studies.

60 APPLIED LIFE SCIENCES↗

Long-term prediction test procedure for most ICs, based on linear response theory

Experimentally, thermal annealing is known to be a factor which enables a number of different integrated circuits (IC's) to recover their operating characteristics after suffering radiation damage in the space radiation environment; thus, decreasing and limiting long term cumulative total-dose effects. This annealing is also known to be accelerated at elevated temperatures both during and after irradiation. Linear response theory (LRT) was applied, and a linear response function (LRF) to predict the radiation/annealing response of sensitive parameters of IC's for long term (several months or years) exposure to the space radiation environment were constructed. Compressing the annealing process from several years in orbit to just a few hours or days in the laboratory is achieved by subjecting the IC to elevated temperatures or by increasing the typical spaceflight dose rate by several orders of magnitude for simultaneous radiation/annealing only. The accomplishments are as follows: (1) the test procedure to make predictions of the radiation response was developed; (2) the calculation of the shift in the threshold potential due to the charge distribution in the oxide was written; (3) electron tunneling processes from the bulk Si to the oxide region in an MOS IC were estimated; (4) in order to connect the experimental annealing data to the theoretical model, constants of the model of the basic annealing process were established; (5) experimental data obtained at elevated temperatures were analyzed; (6) time compression and reliability of predictions for the long term region were shown; (7) a method to compress test time and to make predictions of response for the nonlinear region was proposed; and (8) nonlinearity of the LRF with respect to log(t) was calculated theoretically from a model.

Litovchenko, V.↗

The Doubly Labeled Water Method for Measuring Human Energy Expenditure: Adaptations for Spaceflight

It is essential to determine human energy requirements in space, and the doubly labeled water method has been identified as the most appropriate means of indirect calorimetry to meet this need. The method employs naturally occurring, stable isotopes of hydrogen (H-2, deuterium) and oxygen (O-18) which, after dosing, mix with body water. The deuterium is lost from the body as water while the O-18 is eliminated as both water and CO2. The difference between the two isotope elimination rates is therefore a measure of CO2 production and hence energy expenditure. Spaceflight will present a unique challenge to the application of the doubly labeled water method. Specifically, interpretation of doubly labeled water results assumes that the natural abundance or 'background' levels of the isotopes remain constant during the measurement interval. To address this issue, an equilibration model will be developed in an ongoing ground-based study. As energy requirements of women matched to counterparts in the Astronauts Corps are being determined by doubly labeled water, the baseline isotope concentration will be changed by consumption of 'simulated Shuttle water' which is artificially enriched. One group of subjects will be equilibrated on simulated Shuttle water prior to energy determinations by doubly labeled water while the others will consume simulated Shuttle water after dosing. This process will allow us to derive a prediction equation to mathematically model the effect of changing background isotope concentrations.

Schulz, Leslie O.↗

Ionizing Radiation Environment on the International Space Station: Performance vs. Expectations for Avionics and Material

The role of structural shielding mass in the design, verification, and in-flight performance of International Space Station (ISS), in both the natural and induced orbital ionizing radiation (IR) environments, is reported. Detailed consideration of the effects of both the natural and induced ionizing radiation environment during ISS design, development, and flight operations has produced a safe, efficient manned space platform that is largely immune to deleterious effects of the LEO ionizing radiation environment. The assumption of a small shielding mass for purposes of design and verification has been shown to be a valid worst-case approximation approach to design for reliability, though predicted dependences of single event effect (SEE) effects on latitude, longitude, SEP events, and spacecraft structural shielding mass are not observed. The Figure of Merit (FOM) method over predicts the rate for median shielding masses of about 10g/cm(exp 2) by only a factor of 3, while the Scott Effective Flux Approach (SEFA) method overestimated by about one order of magnitude as expected. The Integral Rectangular Parallelepiped (IRPP), SEFA, and FOM methods for estimating on-orbit (Single Event Upsets) SEU rates all utilize some version of the CREME-96 treatment of energetic particle interaction with structural shielding, which has been shown to underestimate the production of secondary particles in heavily shielded manned spacecraft. The need for more work directed to development of a practical understanding of secondary particle production in massive structural shielding for SEE design and verification is indicated. In contrast, total dose estimates using CAD based shielding mass distributions functions and the Shieldose Code provided a reasonable accurate estimate of accumulated dose in Grays internal to the ISS pressurized elements, albeit as a result of using worst-on-worst case assumptions (500 km altitude x 2) that compensate for ignoring both GCR and secondary particle production in massive structural shielding.

Koontz, Steven L.↗

Insulation Activation and Contamination in Low-Power Experiments

Among the diverse advanced nuclear reactor concepts being developed are designs that expect to operate at much higher temperatures than conventional light-water reactors, and therefore require alternative materials for components capable of withstanding these extreme temperatures. Insulation is one such component where alternative high-temperature industrial composites are being considered. Low-power experiments can provide an opportunity for advancing our understanding of material behavior under irradiation; however, these experiments are not without occupational hazards. The focus of this paper is the potential for activation of insulating composites when exposed to neutron fluence during reactor experiments, and to discuss the subsequent contamination of the testing area. This paper will also discuss practical measures for preventing the creation and inhalation of activated particulate matter (i.e., dust), such as engineering and administrative controls and personal protective equipment. This paper evaluates the suitability of several insulation materials for use in reactor experiments based on their activation from neutron irradiation. The materials considered are Pyrogel XTE by Aspen Aerogel, Cerablanket and Kaowool by Morgan Advanced Materials, Thermo-12 Gold by Johns Manville, and Maxsil CF6-2000 by McAllister Mills. Although these materials are not yet widely used in the nuclear industry, they are common in other industries due to their thermal insulating properties. These materials produce dust while handling that can pose health and safety hazards, which could be further exacerbated by activation. The analysis presented in this paper utilizes a deterministic method developed to predict the activation source term of the provided insulation materials. The method calculates the atomic density of each element within the composites and simulates their exposure to a specified neutron flux density representative of low power experimental conditions. During the irradiation phase and throughout the extensive cooling period, neutron absorptions and nuclear decays are tracked for relevant isotopes. The residual activity within each composite is then assessed to identify the material with the lowest potential radiological hazard to workers. Dust will be created during installation and removal of insulating materials and may also be generated during the experiment. Contamination of surrounding surfaces due to dispersion is highly likely unless preventative measures are taken. The results of this analysis are used to estimate an internal dose from inhalation of activated dust, which is significantly lower than the allowable whole-body dose. However, the risk of internal exposure may increase if the dust becomes a transport vector for nuclear material. The goals of this paper are to enhance the understanding of the potential activation and contamination hazards from the use of these insulating materials in low-power nuclear experiments and to foster safer work environments through informed decision-making and strategic planning. This work ultimately contributes to a broader understanding of how new non-nuclear materials for advanced reactors impact the radiological safety of co-located workers, helping to ensure the responsible management of radioactive materials during installation and decommissioning activities.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

The Analysis of the Patterns of Radiation-Induced DNA Damage Foci by a Stochastic Monte Carlo Model of DNA Double Strand Breaks Induction by Heavy Ions and Image Segmentation Software

To create a generalized mechanistic model of DNA damage in human cells that will generate analytical and image data corresponding to experimentally observed DNA damage foci and will help to improve the experimental foci yields by simulating spatial foci patterns and resolving problems with quantitative image analysis. Material and Methods: The analysis of patterns of RIFs (radiation-induced foci) produced by low- and high-LET (linear energy transfer) radiation was conducted by using a Monte Carlo model that combines the heavy ion track structure with characteristics of the human genome on the level of chromosomes. The foci patterns were also simulated in the maximum projection plane for flat nuclei. Some data analysis was done with the help of image segmentation software that identifies individual classes of RIFs and colocolized RIFs, which is of importance to some experimental assays that assign DNA damage a dual phosphorescent signal. Results: The model predicts the spatial and genomic distributions of DNA DSBs (double strand breaks) and associated RIFs in a human cell nucleus for a particular dose of either low- or high-LET radiation. We used the model to do analyses for different irradiation scenarios. In the beam-parallel-to-the-disk-of-a-flattened-nucleus scenario we found that the foci appeared to be merged due to their high density, while, in the perpendicular-beam scenario, the foci appeared as one bright spot per hit. The statistics and spatial distribution of regions of densely arranged foci, termed DNA foci chains, were predicted numerically using this model. Another analysis was done to evaluate the number of ion hits per nucleus, which were visible from streaks of closely located foci. In another analysis, our image segmentaiton software determined foci yields directly from images with single-class or colocolized foci. Conclusions: We showed that DSB clustering needs to be taken into account to determine the true DNA damage foci yield, which helps to determine the DSB yield. Using the model analysis, a researcher can refine the DSB yield per nucleus per particle. We showed that purely geometric artifacts, present in the experimental images, can be analytically resolved with the model, and that the quantization of track hits and DSB yields can be provided to the experimentalists who use enumeration of radiation-induced foci in immunofluorescence experiments using proteins that detect DNA damage. An automated image segmentaiton software can prove useful in a faster and more precise object counting for colocolized foci images.

Ponomarev, Artem↗

Improving Efficacy and Safety of Pharmacological Treatment Through Precision Health and Pharmacogenomics

INTRODUCTION: Future spaceflight will require increased crew medical autonomy as exploration class missions expand in duration and distance from Earth, especially for Mars missions. As mission duration increases, it will be essential to have appropriate amounts of effective medication to ensure the maintenance of crew health and performance. Conversely, mass and volume constraints will become more severe as future spaceflight expands beyond low Earth orbit, where resupply is difficult or becomes impossible. These constraints thus convey an urgency to tailor medications for individual crewmembers and further examine appropriate dosing regimens. BACKGROUND: Precision Health is an exciting area of medicine focused on maintaining an individual’s health and performance through in-depth understanding of an individual’s unique clinical and environmental history, genetic makeup, and molecular profiles. This approach can be adapted to better predict, monitor, and address physiological responses to the spaceflight environment. A subset of this field is pharmacogenomics (PGX), the study of how the expressed genome impacts drug responses with the goal of prescribing the right dose of the right drug at the right time. Specifically, PGX testing provides valuable information on an individual’s precise allelic variations to guide physicians in making informed decisions on drug choice and dosing to avoid adverse events and maximize efficacy. The study goal was to identify which current space pharmacy drugs could be evaluated using PGX testing and to understand the potential impact on the health and wellness of the astronaut population. Additionally, we sought to evaluate clinically available FDA-approved PGX testing solutions to better understand its applicability. METHODS: A complete list of drugs on the ISS was analyzed for risk and likelihood of drug failure and PGX actionability. This analysis encompassed both astronauts’ personal medications, including supplements and over the counter drugs (n=151) contained in the ISS medical accessory kit (IMAK), and ISS MedKit formulary medications (n=95). Duplicate medications and different formulations were removed, which resulted in a total of 157 drugs used in the subsequent analysis. A 5x5 risk assessment table was produced by examining the likelihood of drug failure compared to the consequence of drug failure (LxC). Likelihood of individual drug failure was defined by whether existing processes are sufficient to prevent ineffective treatment or impactful side effect events, as ranked from 1 (very low, can easily be prevented) to 5 (very high, cannot be prevented) during a Mars mission. In contrast, the consequence of drug failure was defined by impact to safety, schedule, cost, or technical criteria and ranked from 1 (very low) to 5 (very high). An assessment of PGX reference laboratories is currently underway to evaluate sample requirements, benefit analysis (cost vs. utility of allele variant analysis), relevance to inflight medication usage, quality of reporting in enabling clinical application, and ease of integration into electronic medical records. RESULTS: Risk assessments (LxC 5x5 table) indicated 128 medications were in the green zone where risk is acceptable, with the remaining 29 of the medications in the yellow or red zone driven predominantly due to drug failure or safety concerns. We found that current PGX testing results could impact 21% of the total medications in the ISS MedKit and IMAK; of these, 9 medications currently have direct clinically actionable guidance available. Results of the clinical PGX solution evaluations as related to these medications will be presented. CONCLUSION: PGX testing has demonstrated clear benefits in terrestrial medicine and clinical environments for the selection of proper medications, avoiding adverse drug reactions, and maximizing drug efficacy. We propose that similar benefits would be bestowed on the astronaut and commercial spaceflight passenger population by performing preemptive preflight PGX testing to reduce risk of mission failure due to ineffective or toxic medications, improve drug efficacy, and further open the door to countermeasure research. For example, PGX results could allow tailoring of specific medications at optimal doses more precisely to each individual astronaut, particularly in areas of space motion sickness, sleep aids, and analgesics. An additional benefit is that PGX results could provide information for better planning of the components of a space pharmacy for deep space missions to be more effective and efficient in the utilization of limited pharmaceutical resources. Finally, while PGX testing of the astronaut corps is not currently conducted, this approach could provide immediate impact in support of mission success by reducing risks, optimizing astronaut performance, and providing valuable insights into long-term astronaut health. Such advancements in clinical decision making are important next steps in building dynamic individual risk profiles for astronauts, increasing selection of the best treatment choice, and providing tailored countermeasures for individual crewmembers.

Pharmacogenomics↗

Fission foil measurements of neutron and proton fluences in the A0015 experiment

Results are given from sets of fission foil detectors (FFD's) (Ta-181, Bi-209, Th-232, U-238) which were included in the A0015 experiment to measure combined proton/neutron fluences. Use has been made of recent FFD high energy proton calibrations for improved accuracy of response. Comparisons of track density measurements have been made with the predictions of environmental modeling based on simple 1-D (slab) geometry. At 1 g/cm(exp 2) (trailing edge) the calculations were approximately 25 percent lower than measurements; at 13 g/cm(exp 2) (Earthside) calculations were more than a factor of 2 lower. A future 3-D modeling of the experiment is needed for a more meaningful comparison. Approximate mission proton doses and neutron dose equivalents were found. At Earthside (13 g/cm(exp 2) the dose was 171 rad and dose equivalent was 82 rem. At the trailing edge (1 g/cm(exp 2) dose was 315 rad and dose equivalent was 33 rem. The proton doses are less than expected from TLD doses by 16 percent and 37 percent, respectively. These differences can be explained by uncertainties in the proton and neutron spectra and in the method used to separate proton and neutron contributions to the measurements.

Frank, A. L.↗

Improving Efficacy and Safety of Pharmacological Treatment Through Precision Medicine and Pharmacogenomics for Human Deep Space Exploration

INTRODUCTION: Future spaceflight will require increased crew medical autonomy as exploration class missions expanding duration and distance from Earth, especially for Mars missions. As mission duration increases, it will be even more essential to have appropriate amounts of effective medication to ensure the maintenance of crew health and performance. Conversely, mass and volume constraints will become more severe as future spaceflight expands beyond low Earth orbit, where resupply is difficult or becomes impossible. These constraints thus convey an urgency to further tailor medications included in the spacecraft formulary and increased examination of appropriate dosing regimens. BACKGROUND: Precision Health is an exciting area of cutting-edge research and medicine focused on maintaining an individual’s health and performance through in-depth understanding of an individual’s unique factors and molecular profiles. This approach can be adapted to better predict, monitor, and address physiological responses to the spaceflight environment. One example is the field of pharmacogenomics (PGX),the study of how the expressed genome impacts drug responses with the goal of prescribing the right dose of the right drug at the right time. Specifically, PGX testing provides valuable information on an individual’s precise allelic variations to guide physicians in making informed decisions on pharmaceutical choice and dosing to avoid adverse drug events and maximize pharmacological efficacy. The goal of this study was to evaluate which drugs in the current space pharmacy could be evaluated using PGX testing and to understand the potential impact on the health and wellness of the astronaut population. Additionally, we sought to evaluate clinically available FDA-approved PGX testing solutions to better understand its applicability. METHODS: A complete list of drugs onboard the International Space Station (ISS) was analyzed for risk and likelihood of drug failure and PGX actionability. This analysis encompassed both personal astronaut medications, including supplements and over the counter drugs (n=151) and ISS MedKit formulary medications (n=95). Duplicate medications and different formulations were removed, which resulted in 157 total drugs used in the subsequent analysis. A 5x5 risk assessment table was produced by examining the likelihood of drug failure compared to the consequence of drug failure. Likelihood of individual drug failure was defined by whether existing processes are sufficient to prevent adverse events, as ranked from 1 (very low, can easily be prevented) to 5 (very high, cannot be prevented) during a Mars mission. In contrast, the consequence of drug failure was defined by impact to safety, schedule, cost or technical and ranked from 1 (very low) to 5 (very high).A comprehensive assessment of commercially available PGX solutions is currently underway to evaluate specimen requirements, cost/benefit analysis (cost vs. number of alleles assessed), utility of variant analysis, relevance to inflight medication usage, quality of reporting in enabling clinical application, and ease of integration into electronic medical records. RESULTS: Risk assessments(LxC 5x5 table) indicated29medicationswere in the yellow or red zone driven predominantly by drug failure or safety concerns, with the remainder(n=128)of the medications in the green zone where risk is acceptable. We found that current PGX testing results could impact 21% of the total medications in the ISS MedKit and IMAK; of these, 9 medications currently have direct clinically actionable guidance available. Results of the clinical PGX solution evaluations as related to these medications will be presented. CONCLUSION: PGX testing has demonstrated clear benefits in terrestrial medicine and clinical environments for the selection of proper medications, avoiding adverse drug reactions, and maximizing drug efficacy. We propose that similar benefits would be bestowed on the astronaut and commercial spaceflight passenger population by performing preemptive pre-flight PGX testing to reduce risk of mission failure due to ineffective or toxic medications, improve targeting drug efficacy and safety, and further open the door to countermeasure research exploring PGX-related allelic variants. For example, PGX results could allow tailoring of specific medications at optimal doses more precisely to each individual astronaut, particularly in areas of space motion sickness, sleep aids, and analgesics. An additional benefit is that PGX results could provide information for better planning of the components of a space pharmacy for deep space missions to be more cost effective and more efficient in the utilization of limited pharmaceutical resources. Finally, while PGX testing of the astronaut corps is not currently conducted, this approach could provide immediate impact in support of mission success by reducing risks, optimizing astronaut performance, and providing valuable insights into long-term astronaut health. Such advancements in clinical decision making are important next steps in building dynamic individual risk profiles for astronauts, increasing crew autonomy and providing tailored countermeasures

Alice R W Tang↗

Shortcomings in ground testing, environment simulations, and performance predictions for space applications

This paper addresses the issues involved in radiation testing of devices and subsystems to obtain the data that are required to predict the performance and survivability of satellite systems for extended missions in space. The problems associated with space environmental simulations, or the lack thereof, in experiments intended to produce information to describe the degradation and behavior of parts and systems are discussed. Several types of radiation effects in semiconductor components are presented, as for example: ionization dose effects, heavy ion and proton induced Single Event Upsets (SEUs), and Single Event Transient Upsets (SETUs). Examples and illustrations of data relating to these ground testing issues are provided. The primary objective of this presentation is to alert the reader to the shortcomings, pitfalls, variabilities, and uncertainties in acquiring information to logically design electronic subsystems for use in satellites or space stations with long mission lifetimes, and to point out the weaknesses and deficiencies in the methods and procedures by which that information is obtained.

Stassinopoulos, E. G.↗

Atomic-Scale Structural Mapping of Active Sites in Monolayer PGM-Free Catalysts by Low-Voltage 4D-STEM

Two-dimensional (2D) materials have attracted a large amount of attention in both basic and applied fields, and scanning transmission electron microscopy (STEM) is often uniquely well-suited for characterizing the atomic-scale structure of these materials [1-4]. As a result, STEM is poised to significantly impact progress on platinum group metal (PGM)-free catalysts, which are currently under intense development to enable low-cost, commercially viable hydrogen fuel cells [5]. While recent advancements have resulted in fuel cell performance comparable to Pt catalysts by some measures [6], cell durability remains a significant challenge, limiting practical applications [7]. Catalytically active sites in PGM-free materials are proposed to be FeN4 complexes embedded in a graphene lattice (Fig. 1b) within layered or other larger materials, but this is still under debate largely due to the range of potential actives sites predicted by computational methods and lack of methods for directly validating these models [5]. Fundamental insights into the atomic structure and resulting degradation pathways of proposed active sites are therefore needed to fully understand and control cell performance and durability [6].2D materials typically make ideal samples for STEM, but those within PGM-free catalysts present additional challenges since these materials are often defect-rich, with a high density of edges, dopant atoms, etc., which significantly increase susceptibility to beam damage at standard operating voltages. This makes analysis of potential FeN4 active sites particularly challenging, since a large proportion of Fe exists at edge sites where beam-induced atomic displacements can prohibit high-resolution structural characterization [6]. Conventional dark-field imaging compounds this problem by producing less signal for a given dose and being less sensitive to light elements than dose-efficient phase contrast imaging techniques such as those enabled by four-dimensional (4D)-STEM [8-10] (Fig. 1a). Consequently, active site structural analysis is often left to methods such as low-resolution imaging combined with quantum chemical calculations [6], which hinders accurate determination of reaction and degradation mechanisms.Here, we demonstrate direct atomic-scale structural mapping of FeN4 sites by performing low-voltage 4D-STEM on a model PGM-free catalyst system with many exposed monolayer regions. To accomplish this, we pair a 30 keV aberration-corrected probe with a fast pixelated detector that has optimal performance at low beam voltages [11]. This enables us to simultaneously image light and heavy elements with high signal-to-noise by center-of-mass analysis (Fig. 1c) while minimizing beam-induced atomic displacements at sensitive sites. The monolayer nature of these materials additionally allows for experimental validation by direct comparison with multislice simulations [12] of model structures (Fig. 1d-e). This work demonstrates how low-voltage 4D-STEM will provide new insights into the atomic-scale structure and degradation mechanisms of active sites in PGM-free catalysts, facilitating the development of low-cost hydrogen fuel cells and other energy conversion technologies in the future [13].

Zachman, Michael↗

Characterization of radiation damage effects in high-energy neutrino target graphite using low-energy ions

Exposure of graphite targets to high intensity proton beams at neutrino production facilities causes changes in the target material that can result in a shortened operation lifetime. The dominant factors in this process are currently thought to be mechanical in nature resulting primarily from microstructural effects that lead to thermal and structural changes in bulk material properties. As currently planned beam facilities with increased proton energy and intensity begin to come online it will be important to thoroughly understand these processes, and ideally to be able to predict the effects of new beam designs on target properties. Direct analysis of targets exposed to existing high-energy proton beams is complicated by several factors, such as very limited access to proton beam facilities, high associated costs, irradiation times on the order of months, and the resulting radioactivity of irradiated samples that requires special facilities for post-irradiation examination. Much of the existing literature concerning irradiation damage in graphite has been focused on the needs of the nuclear engineering community, however high-energy proton targets operate in a much different environment. In comparison to graphite irradiated in a nuclear reactor, graphite used in proton beam targets receives a higher dose rate, have greater gas production, and experience short irradiation pulses as opposed to continuous irradiation. Low-energy ion irradiation offers a method of inducing similar levels of radiation damage to high-energy protons while avoiding many of the difficulties and limitations associated with high-energy proton beams and the corresponding activated specimen testing. My research described in this thesis focused on investigating how low-energy ion irradiation could be used to induce the same or similar types of microstructural alteration and mechanical property degradation as that seen in high-energy neutrino production target graphites by varying damage le vels and irradiation temperatures prior to post-irradiation characterisation.

43 PARTICLE ACCELERATORS↗

Extrapolation of the dna fragment-size distribution after high-dose irradiation to predict effects at low doses

The patterns of DSBs induced in the genome are different for sparsely and densely ionizing radiations: In the former case, the patterns are well described by a random-breakage model; in the latter, a more sophisticated tool is needed. We used a Monte Carlo algorithm with a random-walk geometry of chromatin, and a track structure defined by the radial distribution of energy deposition from an incident ion, to fit the PFGE data for fragment-size distribution after high-dose irradiation. These fits determined the unknown parameters of the model, enabling the extrapolation of data for high-dose irradiation to the low doses that are relevant for NASA space radiation research. The randomly-located-clusters formalism was used to speed the simulations. It was shown that only one adjustable parameter, Q, the track efficiency parameter, was necessary to predict DNA fragment sizes for wide ranges of doses. This parameter was determined for a variety of radiations and LETs and was used to predict the DSB patterns at the HPRT locus of the human X chromosome after low-dose irradiation. It was found that high-LET radiation would be more likely than low-LET radiation to induce additional DSBs within the HPRT gene if this gene already contained one DSB.

NASA Discipline Radiation Health↗

Machine Learning for Optimized Polarization at Jefferson Lab

Polarized cryo-targets and polarized photon beams are widely used in experiments at Jefferson Lab. Traditional methods for maintaining the optimal polarization involve manual adjustments throughout data taking by human shift takers. This may introduce some level of inconsistency simply due to the wide variety of experience and expertise of the shift takers themselves. Implementing machine learning-based control systems can improve the stability of the polarization without relying on human intervention. The cryo-target polarization is influenced by temperature, microwave energy, the distribution of paramagnetic radicals, as well as operational conditions including the radiation dose. Diamond radiators are used to generate linearly polarized photons from a primary electron beam. The energy spectrum of these photons can drift over time due to changes in the primary electron beam conditions and diamond degradation. As a first step towards automating the continuous optimization and control processes, uncertainty aware surrogate models have been developed to predict the polarization based on historical data. This talk will provide an overview of the use cases and models developed, highlighting the collaboration between data scientists and physicists at Jefferson Lab.

Jeske, Torri [Thomas Jefferson National Accelerato↗