Search NASA⌕ Search

SEARCH · Search NASA

Results for “duration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Advancing Pumped Thermal Energy Storage Performance and Cost Using Silica Storage Media

Pumped Thermal Energy Storage (PTES) is an electricity storage system that is suitable for long-duration energy storage (10-1000 h) due to its low marginal cost of energy capacity. We present a techno-economic model of a PTES system that uses particle thermal energy storage. Particles have low costs and can be operated over a wide temperature range leading to increased efficiency and reduced costs compared to other PTES designs. We show how the round-trip efficiency, specific power output, capital cost, and levelized cost of storage (LCOS) depend on parameters such as the pressure ratio, heat exchanger approach temperature and pressure loss, and maximum temperature. We compare particle-PTES (P-PTES) performance to PTES which uses liquid thermal energy storage - i.e. molten salt hot storage and methanol cold storage (MS-PTES). We find that using silica particles for storage advances PTES technology: P-PTES can be operated at higher maximum temperatures than MS-PTES. Furthermore, P-PTES can achieve lower approach temperatures in the heat exchangers than MS-PTES without increasing capital costs, because P-PTES uses direct-contact heat transfer in fluidized bed heat exchangers. As a result, we find that P-PTES systems achieve higher round-trip efficiency than MS-PTES (66 % versus 57 %) and lower LCOS (e.g. 0.115 +- 0.03 $/kWhe versus 0.171 +- 0.04 $/kWhe for 10 h discharge). The low cost of particles and containment means that P-PTES can provide long-duration energy storage at low capital cost per unit energy capacity. For example, the total capital cost per unit energy reduces from 245 $/kWhe at 10 h to 38 $/kWhe at 100 h. These costs are considerably lower than MS-PTES (72 $/kWhe at 100 h) and also outcompete current and future Li-ion battery system projections (100-265 $/kWhe).

25 ENERGY STORAGE↗

Comparative techno-economic analysis of synthetic renewable natural gas production via reactive CO 2 capture and conversion

Reactive CO 2 capture and conversion (RCC) is an emerging carbon management strategy that integrates CO 2 capture and conversion and avoids intermediate CO 2 purification. In this study, we design an RCC process to capture atmospheric CO 2 and react it with renewable hydrogen to produce synthetic renewable natural gas (SRNG), which serves as a carbon-neutral energy source and a chemical form of long-duration renewable energy storage. We assess the technological potential of RCC through process modeling, techno-economic, carbon footprint, and sensitivity analyses. Our findings demonstrate that RCC offers energy savings and comparable cost to separated capture and conversion processes. The cost is dominated by renewable hydrogen and material replacement cost. SRNG produced via RCC is competitive with existing low-carbon natural gas technologies and presents a promising low-cost option for long-duration energy storage. This work highlights the potential for deploying RCC technologies within a circular carbon economy and the scientific and technical challenges that must be overcome for material and technology developers.

03 NATURAL GAS↗

A review of Geological Thermal Energy Storage for seasonal, grid-scale dispatching

Energy storage is essential for the decarbonization of the U.S. energy grid, especially with the increasing deployment of variable renewable energy sources like solar and wind. Geological thermal energy storage (GeoTES) has emerged as a promising long duration, grid scale solution, providing stability and security through flexible operations and valuable grid services. GeoTES utilizes subsurface reservoirs to store thermal energy for power generation and direct-use heating and cooling. This approach significantly enhances the use of low-temperature reservoirs, which would otherwise be unsuitable for geothermal power plants. It also aligns well with depleted oil and gas reservoirs, concentrating solar power, non-flexible renewables (photovoltaic and wind), and geothermal-related power cycles. Given the favorable marginal costs of GeoTES as storage duration increases, it becomes particularly competitive for seasonal, grid-scale dispatch, where few technologies are viable. This paper provides a comprehensive review of GeoTES systems and the research underpinning itsr development. This analysis begins by defining and categorizing the unique characteristics of thermal energy storage techniques, setting GeoTES apart from other technologies. The various components, configurations, subsurface characteristics, and modeling efforts that guide GeoTES development are then explored. Finally, challenges in GeoTES research, development, and deployment are discussed, along with mitigation strategies and lessons from related technologies. Beyond their economic benefits, GeoTES systems support grid resilience and decarbonize industrial processes. Their scalability, broad distribution, seasonal storage potential, and flexible dispatch capacity make GeoTES a valuable tool for expanding renewable energy deployment and addressing climate change.

15 - GEOTHERMAL ENERGY↗

System and Component Development of Particle-Based Pumped Thermal Energy Storage

Reliable power supply from variable renewable resources requires energy storage at various scales to overcome resource intermittency. Long-duration energy storage (LDES, 10-100 hours) can improve dispatchability and grid reliability with increasing levels of renewable power supply. Thermal energy storage (TES) has siting flexibility and the ability to store a large capacity of energy, and thus has the potential to meet the LDES need and provide charging and discharging durations beyond the economic capacity of conventional batteries. TES technology has evolved from concentrating solar thermal power (CSP) generation and is recognized as an economic large-scale energy storage method. A standalone electric-thermal energy storage system supporting renewable integration of wind and solar power without CSP solar field can firm renewable generation and boost overall grid resilience and security.

concentrating solar thermal power↗

Data and code for Daily and Multi-Day Extreme Rainfall Analysis Under Future Climates Using Stochastic Storm Transposition and NEX-GDDP-CMIP6 Over CONUS

This data package provides inputs, codes, and outputs for a comprehensive analysis of projected changes in extreme precipitation across 10 regions of the continental United States, using 34 downscaled Earth System Models (ESMs) from the NASA Earth Exchange Global Daily Downscaled Projections, Coupled Model Intercomparison Project Phase 6 (NEX-GDDP-CMIP6) dataset. These models are part of the Coupled Model Intercomparison Project Phase 6 (CMIP6), a coordinated climate modeling framework widely used to assess climate change impacts. The analysis applies a stochastic storm transposition method to quantify changes in extreme rainfall under two Shared Socioeconomic Pathway (SSP) climate scenarios—SSP2-4.5 (moderate emissions) and SSP5-8.5 (high emissions)—compared to historical conditions (1995–2014 vs. 2081–2100). The dataset includes rainfall depth estimates for extreme events with return periods from 2 to 500 years across multiple storm durations (1, 3, and 5 days) for each of the 10 U.S. regions. Weighted ensemble statistics are derived from individual ESM performance against historical precipitation patterns, enabling robust uncertainty quantification through both sign-based and permutation-test-based model agreement assessments. Key analyses address: (1) relative changes in extreme precipitation for each climate scenario, (2) differences between SSP scenarios (SSP5-8.5 vs. SSP2-4.5), (3) contrasts between rare and frequent events, and (4) variations between multi-day and daily storm durations. The workflow produces ensemble statistics—median, 5th, 25th, 75th, and 95th percentiles—along with model agreement metrics that identify regions and event types with robust climate change signals. The dataset includes: processed rainfall depth outputs (netCDF format) from the RainyDay Python package, ESM weights from historical performance evaluation using DayMet observations, ensemble statistics across all storm dimensions, and figures summarizing key findings.

54 ENVIRONMENTAL SCIENCES↗

Pilot Development Progress to Demonstrate Electric Thermal Energy Storage (ETES) Using Low-Cost Particles

The rapid growth of future energy demand increases the need to economically store electrical energy over durations up to several days in long-duration energy storage (LDES) applications. LDES can reduce the grid stress for improving the resilience of the grid. The integration of renewable power and storage has several significant and positive impacts including expanding the renewable energy portion of electricity generation, meeting peak-load demand, and coordinating supply and demand. Several energy storage approaches including mechanical, chemical and electrochemical methods are currently deployed or under development. However, LDES requirements pose unique challenges for scalability, energy capacity, and cost. Thermal energy storage (TES) has the ability to store a large capacity of energy with improved site flexibility compared to incumbent LDES technologies (i.e., pumped hydro) and has attracted significant interest. Our development in TES technology using solid particles as the storage medium has shown feasibility and potential in serving LDES purposes. Particle TES has various advantages over commercialized molten nitrate salt TES and has emerged as a promising storage technology originating from Generation 3 concentrating solar power (CSP) development. Stable, inexpensive silica sand produced in the Midwestern U.S. was identified as a suitable storage medium and has been validated through lab heating and cycling tests. We have successfully developed particle TES for bidirectional electric energy storage to broaden the applications for TES beyond CSP technologies and into standalone electric-thermal energy storage (ETES) systems. Key component designs and performance were verified with prototype testing and model simulations. The ETES system uses high-temperature, low-cost particle thermal energy storage coupled with a unique pressurized fluidized bed heat exchanger that supports a high-efficiency, air-Brayton combined power cycle. At times of low energy demand or high renewable production, an electric particle heater heats large quantities of solid particles to high temperatures in excess of 1100 degrees C. The particles are stored in internally insulated silos. At times of high electricity demand, the hot particles are gravity-fed through the heat exchanger where stored thermal energy is transferred to the power cycle working fluid to drive the gas turbine power generation system, thereby converting the thermal energy back into electricity for the grid. The cold particles leaving the heat exchanger are returned to the storage silos by a well-insulated particle conveyor. This ETES technology using particle TES can be sited anywhere and is predicted to be economic and efficient. Moreover, this ETES technology could be co-located with a retired coal or gas plant to leverage existing power generation and grid infrastructure. Our work has focused on the development of each of the key components (e.g., the electric particle heater, particle storage silos, and the particle-to-gas pressurized fluidized bed heat exchanger) through conceptual designs, prototype testing, and computational modeling. These developments demonstrate technological feasibility and are an important step towards the next phase of development of this promising LDES technology. This presentation will show the progress in developing a pilot demonstration of the ETES system on a commercially relevant scale.

25 ENERGY STORAGE↗

Pilot Development Progress to Demonstrate Electric Thermal Energy Storage (ETES) Using Low-Cost Particles

The rapid growth of variable renewable power generation increases the need to economically store electrical energy over durations up to several days in long-duration energy storage (LDES) applications. LDES can bridge the intermittency of increasing variable renewable energy (VRE) and facilitate emission-free dispatchable electricity to improve the resilience of the grid and provide reliable and potentially cost-effective energy. Several energy storage approaches including mechanical, chemical and electrochemical methods are currently deployed or under development. However, LDES requirements pose unique challenges for scalability, energy capacity, and cost. Electro-thermal energy storage (ETES) can store a large capacity of energy with site flexibility and has attracted significant interest for LDES purposes. This paper shows the progress of developing a demonstration test facility for particle ETES technology including pilot-scale component design and fabrication.

25 ENERGY STORAGE↗

Technoeconomic Analysis of Discrete and Unitized Reversible Fuel Cells for Energy Storage Applications

Reversible Fuel Cell (RFC) systems offer promising characteristics for stationary long duration energy storage applications. Two main configurations of RFC systems exist: discrete RFC systems and unitized RFC systems. While discrete RFC systems combine independent fuel cell and electrolyzer systems for energy storage, unitized RFC systems utilize a single electrochemical stack and might share balance of plant (BOP) components for both charging and discharging processes. While this configuration reduces upfront capital costs, challenges of unitized RFC designs include potential performance trade-offs due to dual-mode stack design and operational complexities across varying loads and operating conditions. Furthermore, these tradeoffs might be different for low-temperature PEM RFCs than for high-temperature reversible solid oxide cell systems. The goal of this project is to assess unitized RFC system potential in the context of long duration grid energy storage and HFTO's technical targets for different discrete fuel cell and electrolyzer technologies. This presentation presents preliminary review of state-of-the-art unitized RFC cells and assesses how they perform relative to HFTO's technical targets. It also presents literature-derived system configurations worth investigating. This review indicates that lab-scale unitized RFCs are making good progress towards meeting HFTO's technical targets.

HYDROGEN↗

Interlayer Exciton Polarons in Mesoscopic V 2 O 5 for Broadband Optoelectronic Synapses

Persistent photoconductivity and optoelectronic synaptic behavior are demonstrated in solution-processed mesoscopic α-phase vanadium pentoxide (V 2 O 5 ) thin films. First-principles simulations coupled with the two-site Holstein polaron hopping model show that vacancies at the terminal oxygen position lead to long recombination times because photoexcited electrons and holes reside on different layers separated by the van der Waals gap, forming a weakly coupled interlayer exciton polaron. Mid-gap polaronic states also significantly broaden the photoresponse of the films to span across visible and infrared wavelengths. By controlling the amplitude/intensity, duration, and/or number of optical pulses, tunable optoelectronic memory functions, such as short-term and long-term plasticity, are experimentally established in V 2 O 5 -based optoelectronic synapses. Furthermore, device fabrication was extended to mechanically flexible ultrathin glass substrates. Flexible optoelectronic synapses maintained high performance after 150 bending cycles.

Phan, Thanh Luan [National Renewable Energy Labora↗

Approaching the Lower Temporal Limit of Laser‐Produced Plasma Sources for Table‐Top Soft X‐Ray NEXAFS Measurements

Abstract The increasing popularity of time‐resolved X‐ray absorption measurements for understanding dynamics in molecular and material systems has led to many advances in table‐top sources for pulsed X‐rays. We report on a table‐top laser‐produced plasma (LPP) source that can perform soft X‐ray (SXR), near‐edge X‐ray absorption fine structure (NEXAFS) measurements using a laser source with 23 ps pulse duration. The spectrometer's key specifications, such as brilliance, resolution, and stability, are characterized against the more commonly used longer‐pulse‐duration LPP sources. The 23 ps laser produced approximately an order of magnitude weaker SXR flux than the 8 ns laser for a higher power density due to the smaller total energy absorbed by the plasma. The increased repetition rate, as well as the use of a high line‐density X‐grating, and a self‐referencing scheme still allowed for NEXAFS measurements of Si 3 N 4 and TiO 2 thin films with 2.5 minute acquisition times, a resolving power of E/ΔE=424, and a signal‐to‐noise ratio of 100. It was observed that degradation of the gas jet nozzle led to long‐term instability of the source, which can be remediated using alternative nozzle designs. This work demonstrates the feasibility of achieving higher temporal resolution in future time‐resolved X‐ray absorption measurements using table‐top LPP sources.

Nimlos, Danika [Division of Chemistry and Chemical↗

Applicability of 1D site response analysis to shallow sedimentary basins: A critical evaluation through physics-based 3D ground motion simulations

One-dimensional site response analysis (1D SRA) remains the standard practice in considering the effect of local soil deposits and predicting site-specific ground motions, although its range of applicability to realistic seismic wavefields is still in question. In this 1D approach, horizontal and vertical ground shaking are assumed to be induced by vertically propagating shear and compressional waves, respectively. A recent study based on analytical two-dimensional (2D) plane waves and simple point source earthquake simulations has shown two mechanistic limitations in this 1D modelling technique for general inclined seismic waves, that is, systematic over-prediction of the vertical motion and wave trapping in the 1D soil column. In this article, we evaluate in detail the applicability of this 1D modelling approach to realistic three-dimensional (3D) simulated seismic wavefields in shallow sedimentary basins. Linear-viscoelastic 1D SRA predictions using two types of input motions that are commonly used in practice—rock outcrop and in-column motions, are compared with the reference true site response results from 3D earthquake simulations in terms of various measures in the frequency and time domain. It is shown that the horizontal motion in the 3D seismic wavefield exhibits dominant shear wave propagation phenomenon, while the vertical motion is a combined effect of compressional and shear waves and can be over-predicted by the 1D approach when the incident seismic waves are inclined. Direct evidence of the wave refraction process that leads to the vertical motion over-prediction is provided. 1D SRA with in-column inputs can yield motions that have significantly longer duration compared to the true 3D site response solution due to trapped waves, casting in doubt the frequent need for increased soil damping in existing site studies to compensate for wave attenuation due to scattering alone. Sensitivity investigation on the increase of soil profile damping by a multiplier D mul shows D mul values compatible with those found in the literature for both horizontal and vertical motions. It is shown that the level of D mul optimized for a best match of the spectral acceleration is dependent on the characteristic of the input motion and a larger D mul is typically required for the vertical component. In contrast, 1D SRA with outcrop motions predicts motions with shorter significant duration due to its inability to capture the basin-edge generated surface waves. A suite of ground motion simulations was performed to assess the sensitivity of the observations to the basin geologic structure including the velocity gradient, rock-basin impedance contrast and basin depth. The analysis results show that the accuracy of the simplified 1D procedure is dependent on the wavefield composition of both the input motions and the true 3D site response solution. While the horizontal motions in shallow sedimentary basins can, to the first order, be reasonably captured by the simplified 1D approach, 1D SRA for the vertical component is in general not reliable and contributions from inclined shear waves should be accounted for in site-specific evaluation of the vertical design ground motion.

1D assumption↗

Anticipating how rain-on-snow events will change through the 21st century: lessons from the 1997 new year’s flood event

The California-Nevada 1997 New Year’s flood was an atmospheric river (AR)-driven rain-on-snow (RoS) event and remains the costliest in their history. The joint occurrence of saturated soils, rainfall, and snowmelt generated inundation throughout northern California-Nevada. Although AR RoS events are projected to occur more frequently with climate change, the warming sensitivity of their flood drivers across scales remains understudied. We leverage the regionally refined mesh capabilities of the Energy Exascale Earth System Model (RRM-E3SM) to recreate the 1997 New Year’s flood with horizontal grid spacings of 3.5 km across California, with forecast lead times of up to 4 days, and across six warming levels ranging from pre-industrial conditions to +3.5° C. We describe the sensitivity of the flood drivers to warming including AR duration and intensity, precipitation phase, intensity and efficiency, snowpack mass and energy changes, and runoff efficiency. Our findings indicate current levels of climate change negligibly influence the flood drivers. At warming levels ≥ 1.7° C, AR hazard potential increases, snowpack nonlinearly decreases, antecedent soil moisture decreases (except where the snowline retreats), and runoff decreases (except in the southern Sierra Nevada where antecedent snowpack persists). Storm total precipitation increases, but at rates below warming-induced increases in saturation-specific humidity. Warming intensifies short-duration, high-intensity rainfall, particularly where snowfall-to-rainfall transitions occur. This study highlights the nonlinear tradeoffs in 21st-century RoS flood hazards with warming and provides water management and infrastructure investment adaptation considerations.

54 ENVIRONMENTAL SCIENCES↗

Enhancing Building Resilience: Maintaining Energy Efficiency and Thermal Comfort During Power Outages in Cold Climates

The increasing frequency and intensity of extreme weather events, such as heatwaves and cold snaps, present significant challenges to building energy performance and occupant comfort. Highly correlated with climate events are widespread long duration power interruptions that may affect thousands of buildings and millions of customers. This study evaluates the impact of building energy performance and occupant thermal comfort in medium-sized office buildings in a cold climate region. Using energy models representing pre-1980 and 2019 vintages, simulations were conducted to assess energy performance under typical weather conditions and occupant thermal comfort during power interrupted extreme cold snap and heatwave climate events under both current 2020s and future 2050s weather conditions. The results show a projected 33% increase in cooling energy demand and a 19% reduction in heating energy by 2050. Findings reveal that older buildings are more susceptible to cold discomfort during cold snaps, while modern airtight buildings are more vulnerable to overheating during heatwaves. Various passive energy efficiency measures, such as improved infiltration control, thermal windows, solar-controlled windows, and cool envelopes, were evaluated for their ability to mitigate thermal discomforts. Solar controlled windows and weatherstripping contribute to reducing cold thermal discomfort by 21% during a power-interrupted cold snap. Solar-controlled windows were found to reduce hot thermal discomfort by 34% during a future power-interrupted heatwave. The study highlights the importance of targeted retrofitting strategies to enhance thermal resilience, especially during power outages, to ensure occupant safety and comfort during extreme climate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of fuel film formation and soot emissions in a GDI engine during cold-start with Split-injection strategies

This study investigates the impact of fuel-film formation on engine-out soot emissions in a gasoline direct injection (GDI) engine under cold-start conditions. Split-injection strategies were applied by varying the number of injections, injection duration, and total fuel quantity to affect wall wetting and control the average in-cylinder equivalence ratio. A combined experimental and numerical approach was employed to analyze fuel-film deposition, combustion efficiency, and engine-out soot and unburnt hydrocarbons (UHC) emissions. In particular, fuel film distribution estimated by means of non-reacting, 3-D, computational fluid dynamics (CFD) simulations, together with experimentally measured soot data, were used to investigate fuel film formation and its role in soot generation. In the experiments, a skip-fired engine control strategy was applied to mimic the transient nature of engine cold-start operation. The results indicate that, under the same total number of injections, increasing the average in-cylinder equivalence ratio through longer injection durations improves combustion stability, as indicated by the decrease of the coefficient of variation of IMEP n (Net Indicated Mean Effective Pressure) from 6.0 % to 0.6 %. However, this strategy leads to higher soot emissions, which increased by nearly an order of magnitude, primarily due to enhanced wall-film formation. In contrast, increasing the number of injections while maintaining a constant equivalence ratio significantly impacts fuel-film deposition and, consequently, soot emissions, with a fivefold reduction of the measured engine-out soot, decreasing from 3.5 mg to 0.7 mg. A soot-film correlation was developed and achieved a high coefficient of determination (r 2 = 0.95) and was further extended to account for spark timing effects. These findings confirm the effectiveness of split-injection for avoiding wall film formation and soot emissions, and the critical role of fuel film in soot generation, supporting the hypothesis that pool fires play a crucial role in contributing to soot formation under these cold-start conditions. In conclusion, the study also indicates the value of a predictive soot-film correlation for developing cold-start emission control strategies.

Engine Cold-start↗

Thermoelectric heating and cooling–integrated dishwasher with thermal energy storage

Household dishwashers must address several performance goals: maximize washing and drying performance, while minimizing cycle duration, energy consumption, and water consumption. This study develops and examines a novel thermoelectric heating and cooling (TEHC) system with thermal energy storage applied to a household dishwasher (DW), aiming to improve the energy and drying performance of a commercially-available dishwasher while maintaining its washing performance, water consumption, and cycle duration. Experimental testing conducted on the novel TEHC-DW system demonstrates an 8.7% reduction in total energy consumption, lowering the per-cycle usage to 0.952 kWh, and a 40% reduction in energy consumption for internal water heating. The novel TEHC-DW system also demonstrates better drying performance, shortening the drying time by 42% to reach the same remaining moisture content as a commercially-available system. In addition, a resistance-capacitance network model is developed that predicts total drying time, total energy consumption, and the highest temperature reached in the tub (53.4 °C). The model accuracy is validated with experimental data (within ±1 K), and the model functions as a design tool via a parametric study to evaluate the next-generation design and the effect of the number of thermoelectric modules and thermoelectric driving force (i.e., current). Overall, this study demonstrates the potential for TEHC technology to improve energy efficiency and drying performance in household dishwashers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid power plants: An effective way of decreasing loss-of-load expectation

Diversifying variable renewable resources by combining wind, solar photovoltaic, and battery assets in a hybrid power plant can increase renewable energy usage efficiency and improve system flexibility, particularly in distributed energy systems. However, the resilience impact of these systems, particularly outage mitigation, can be difficult to quantify due to uncertainty in resource, energy demand, and outage occurrence. Here, this study outlines a framework to quantify the incremental benefit of hybrid power plant assets for reducing loss-of-load expectation during random outage events. Hybrid power plant performance during outages (considering varying duration and severity) is simulated using a Monte Carlo methodology to reflect uncertainty associated with renewable resource, load demand, and outage timing. Results demonstrate the additional incremental value from increasingly hybrid designs, in which relative capacities of wind, solar photovoltaic, and storage assets contribute to lower loss-of-load expectation than the constituent technologies would alone. The value of added wind or solar capacity increases as the plant composition approaches an equal split. The value of added battery capacity depends on the outage duration and severity, but the first 50 MWh of added storage capacity is the most valuable for reducing the loss-of-load expectation for all plant designs.

14 SOLAR ENERGY↗

Hybrid combustion modeling approach for turbulent jet ignition in natural-gas pre-chamber spark-ignition engines at high EGR

Here, this study presented a hybrid modeling approach for simulating turbulent jet ignition and combustion processes in a natural-gas pre-chamber spark-ignition engine operating under exhaust gas recirculation (EGR) diluted conditions. In-depth analyses of experimental data and simulation results from previous work [Chinnathambi et al., ICEF2021-67836; Kim et al., Fuel 409: 137815, 2026] revealed two key findings: (i) the magnitude of pressure difference between the pre-chamber and main chamber ($∆P_{PC-MC}$) was positively correlated with the combustion duration from the moment of $∆P_{PC-MC}=0$ to the point of 5% mass fraction burned, with larger $∆P_{PC-MC}$ associated with longer duration; and (ii) the turbulent combustion regime in the main chamber transitioned from the broken reaction zone to the corrugated flamelet regime, with the Karlovitz number exceeding 100 immediately after turbulent hot jets were ejected from nozzles, coinciding with observed local extinction events. To accurately simulate the entire combustion process, a hybrid approach was developed under Reynolds-Averaged Navier Stokes framework, combining the G-equation model for pre-chamber combustion with the multi-zone well-stirred reactor approach and a turbulence-chemistry interaction (TCI) submodel for main chamber combustion. The TCI submodel accounted for the attenuation of reaction rates due to turbulent strain and modeled local extinction by suppressing reaction rates under certain flow and flame conditions. When applied to three EGR rate conditions toward the dilution limit, the hybrid modeling approach accurately reproduced experimental data in terms of cylinder pressure, apparent heat release rate, and the observed positive correlation, including the delayed onset of main chamber combustion—a feature not captured by existing combustion models.

computational fluid dynamics simulation↗

Modeling and Experimental Validation of a Direct-Contact Counter-Flow Fluidized Bed Heat Exchanger for Thermal Energy Storage (TES) Applications

Particle-based thermal energy storage (TES) systems are an emerging energy storage technology. The technological advances have reduced costs, making TES more competitive and reliable in the marketplace but an efficient and reliable operation is heavily dependent on coherent heat transfer between air to particles or vice versa. The particle-based TES technologies provide an intermediate system that can store energy for short (0-10 h), long (10-200 h) and seasonal (> 200 h) timescales. The TES systems store energy by converting electricity to thermal energy; electricity can be directly sourced intermittent generation technologies and/or the grid, helping manage peak loads and other mismatches in supply and demand. The overall efficiency of the TES system depends on the performance of system components (particle storage silos and particle transfer mechanism etc.). The particle heat exchanger is one of the key system components that affects the system efficiency. The pressurized fluidized bed heat exchanger (PFB HX) performance is challenging to predict due to the chaotic behavior of particle and fluid interaction. This research presents a computational study of a novel direct-contact, counter-flow and air-to-particles PFB HX, that contributes in advancing the particle-based long-duration TES technologies. For the current analysis an unsteady Eulerian-Eulerian CFD model was developed and validated against experiments performed at the National Laboratory of the Rockies for two particle sizes (600 ..mu..m and 825 ..mu..m ). Following validation, parametric simulations were conducted to evaluate the effects of interphase drag models (Syamlal-O'Brien and Gidaspow), particle size, bed height and the influence of a frictional-viscosity term on hydrodynamics and heat transfer between the air & particles. The key findings from the analysis are: (1) for the studied operating window Syamlal-O'Brien provides superior agreement with measured gas temperatures (errors generally < 10%) while Gidaspow shows large deviations for the coarse particle case; (2) model predictions are most sensitive in the lower 0.2 m above the air distributor where bubble initiation and local mixing dominate interphase heat transfer; (3) representation of the distributor (number of inlet ports) materially affects predicted local mixing and temperature stratification; and (4) the Eulerian-Eulerian framework reproduces bulk thermal trends but shows regime dependent limitations for coarse particles, motivating mesoscale informed closures for scale-up analysis for future studies. These results provide validated guidance for drag selection and distributor design in particle-based thermal energy storage applications. Collectively, the validated model and parametric results quantify key drivers of PHB-HX performance and provide practical guidance for design and optimization. The results provide confidence in the model predictability and provide a step forward to improve on heat exchange performance. The demonstrated performance and modeling approach support the deployment and further development of this novel PHB-HX concept for robust, particle-based long-duration thermal energy storage systems.

25 ENERGY STORAGE↗