Search NASA⌕ Search

SEARCH · Search NASA

Results for “efficient envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Windows and Building Envelope Research and Development: A Roadmap for Emerging Technologies

This Building Technologies Office (BTO) Research and Development (R&D) Roadmap identifies priority windows and building envelope R&D areas of interest. Cost and performance targets are identified for each key R&D area. The roadmap describes the technical and market challenges to be overcome, R&D activities and milestones, key stakeholders, and potential energy savings that could result if cost and performance targets are met. Methods for improving technology performance and specific strategies for reducing installed costs and mitigating any other market barriers, which would increase the likelihood of mass-market technology adoption, are identified. This roadmap is a useful resource for public and private decision makers evaluating and pursuing high-impact R&D focused on advancing next-generation energy efficient windows and building envelope technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pennsylvania and Delaware Energy Code Field Studies (Final Technical Report (FTR)

Led by Northeast Energy Efficiency Partnerships (NEEP) in partnership with Performance Systems Development (PSD), the project aimed to conduct energy code compliance field studies for single-family residential buildings in Pennsylvania and Delaware, as well as multifamily and commercial buildings in Pennsylvania. Using U.S. Department of Energy (DOE) approved methodologies, trained field teams conducted on-site observations and testing to document compliance with key energy efficiency measures, including building envelope insulation, air sealing, duct leakage, windows, and mechanical systems. Data from these studies would then be analyzed to identify construction trends and compliance gaps. The goals included published baseline data for each study, and a training roadmap tailored to each state’s needs. This roadmap would have guided outreach and training for builders, code officials, and other stakeholders on the specific code requirements that offered the greatest opportunity for improvement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Structure Computation of Quiet Spike[Trademark] Flight-Test Data During Envelope Expansion

System identification or mathematical modeling is used in the aerospace community for development of simulation models for robust control law design. These models are often described as linear time-invariant processes. Nevertheless, it is well known that the underlying process is often nonlinear. The reason for using a linear approach has been due to the lack of a proper set of tools for the identification of nonlinear systems. Over the past several decades, the controls and biomedical communities have made great advances in developing tools for the identification of nonlinear systems. These approaches are robust and readily applicable to aerospace systems. In this paper, we show the application of one such nonlinear system identification technique, structure detection, for the analysis of F-15B Quiet Spike(TradeMark) aeroservoelastic flight-test data. Structure detection is concerned with the selection of a subset of candidate terms that best describe the observed output. This is a necessary procedure to compute an efficient system description that may afford greater insight into the functionality of the system or a simpler controller design. Structure computation as a tool for black-box modeling may be of critical importance for the development of robust parsimonious models for the flight-test community. Moreover, this approach may lead to efficient strategies for rapid envelope expansion, which may save significant development time and costs. The objectives of this study are to demonstrate via analysis of F-15B Quiet Spike aeroservoelastic flight-test data for several flight conditions that 1) linear models are inefficient for modeling aeroservoelastic data, 2) nonlinear identification provides a parsimonious model description while providing a high percent fit for cross-validated data, and 3) the model structure and parameters vary as the flight condition is altered.

Kukreja, Sunil L.↗

F-15B QuietSpike(TradeMark) Aeroservoelastic Flight Test Data Analysis

System identification or mathematical modelling is utilised in the aerospace community for the development of simulation models for robust control law design. These models are often described as linear, time-invariant processes and assumed to be uniform throughout the flight envelope. Nevertheless, it is well known that the underlying process is inherently nonlinear. The reason for utilising a linear approach has been due to the lack of a proper set of tools for the identification of nonlinear systems. Over the past several decades the controls and biomedical communities have made great advances in developing tools for the identification of nonlinear systems. These approaches are robust and readily applicable to aerospace systems. In this paper, we show the application of one such nonlinear system identification technique, structure detection, for the analysis of F-15B QuietSpike(TradeMark) aeroservoelastic flight test data. Structure detection is concerned with the selection of a subset of candidate terms that best describe the observed output. This is a necessary procedure to compute an efficient system description which may afford greater insight into the functionality of the system or a simpler controller design. Structure computation as a tool for black-box modelling may be of critical importance for the development of robust, parsimonious models for the flight-test community. Moreover, this approach may lead to efficient strategies for rapid envelope expansion which may save significant development time and costs. The objectives of this study are to demonstrate via analysis of F-15B QuietSpike(TradeMark) aeroservoelastic flight test data for several flight conditions (Mach number) that (i) linear models are inefficient for modelling aeroservoelastic data, (ii) nonlinear identification provides a parsimonious model description whilst providing a high percent fit for cross-validated data and (iii) the model structure and parameters vary as the flight condition is altered.

Kukreja, Sunil L.↗

Effects of stratification on overshooting and waves atop the convective core of M ⊙ main-sequence stars

As a massive star evolves along the main sequence, its core contracts, leaving behind a stable stratification in helium. We simulate two-dimensional convection in the core at three different stages of evolution of a $5\,\mathrm{ M}_{\odot }$ star, with three different stratifications in helium atop the core. We study the propagation of internal gravity waves in the stably stratified envelope, along with the overshooting length of convective plumes above the convective boundary. We find that the stratification in helium in evolved stars hinders radial motions and effectively shields the radiative envelope against plume penetration. This prevents convective overshooting from being an efficient mixing process in the radiative envelope. In addition, internal gravity waves are less excited in evolved models compared to the zero-age-main-sequence model, and are also more damped in the stratified region above the core. As a result, the wave power is several orders of magnitude lower in mid- and terminal-main-sequence models compared to zero-age-main-sequence stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Excitation of gravity waves in common envelopes

We study the excitation of gravity waves by a low-mass companion orbiting inside the envelope of a giant star, concentrating on brown dwarfs inside the envelope of asymptotic giant branch stars. Efficient g-wave excitations occur only after the brown dwarf has spiraled-in to the radiative zone, well inside the envelope, of the asymptotic giant branch star. The brown dwarf excites g-waves when its orbital radius is about 3-10 solar radii. At this stage of the evolution the envelope mass is below 0.1 solar mass. The g-waves propagate inward from the secondary orbit, carrying angular momentum and energy. We find that the angular momentum transport leads to an efficient spin-up of the inner envelopes. The differential rotation between the envelope and core and nonlinear wave effects, can cause a mixing of heavy elements from the core to the envelope.

Soker, Noam↗

Low-Cost Bio-Based Phase Change Materials as an Energy Storage Medium in Building Envelopes

A promising approach to increasing the energy efficiency of buildings is the implementation of phase change material (PCM) in building envelope systems. Several studies have reported the energy saving potential of PCM in building envelopes. However, wide application of PCMs in building applications has been inhibited, in part, by their high cost. This article describes a novel paraffin product made of naturally occurring fatty acids/glycerides trapped into high density polyethylene (HDPE) pellets and its performance in a building envelope application, with the ultimate goal of commercializing a low-cost PCM platform. The low-cost PCM pellets were mixed with cellulose insulation, installed in external walls and field-tested under natural weatherization conditions for a period of several months. In addition, several PCM samples and PCM-cellulose samples were prepared under controlled conditions for laboratory-scale testing. The laboratory tests were performed to determine the phase change properties of PCM-enhanced cellulose insulation both at microscopic and macroscopic levels. This article presents the data and analysis from the exterior test wall and the laboratory-scale test data. PCM behavior is influenced by the weather and interior conditions, PCM phase change temperature and PCM distribution within the wall cavity, among other factors. Under optimal conditions, the field data showed up to 20% reduction in weekly heat transfer through an external wall due to the PCM compared to cellulose-only insulation.

low-cost PCM↗

Measurements of electron detection efficiencies in solid state detectors.

Detailed laboratory measurement of the electron response of solid state detectors as a function of incident electron energy, detector depletion depth, and energy-loss discriminator threshold. These response functions were determined by exposing totally depleted silicon surface barrier detectors with depletion depths between 50 and 1000 microns to the beam from a magnetic beta-ray spectrometer. The data were extended to 5000 microns depletion depth using the results of previously published Monte Carlo electron calculations. When the electron counting efficiency of a given detector is plotted as a function of energy-loss threshold for various incident energies, the efficiency curves are bounded by a smooth envelope which represents the upper limit to the detection efficiency. These upper limit curves, which scale in a simple way, make it possible to easily estimate the electron sensitivity of solid-state detector systems.

Lupton, J. E.↗

Pathway to Zero Energy Windows: Advancing Technologies and Market Adoption

As of 2021, buildings account for 39.1% of total U.S. primary energy use and 75% of total U.S. electricity use. Much of this energy is used to maintain a comfortable indoor environment. The building envelope consists of transparent and opaque elements that serve as a controllable barrier to help maintain the indoor environment regardless of external conditions. The envelope also allows the exchange of light and air, as well as other transfers with the external environment when it is beneficial for the building occupants. By leveraging desirable external environmental conditions (e.g., fresh air and natural light) and mitigating the influence of undesirable conditions (e.g., moisture, hot or cold temperatures, wind), the building envelope can reduce the need for space conditioning and electric light, and thus reduce energy use associated with lighting and heating, cooling, and ventilation equipment. In turn, high-performance building envelopes can reduce the substantial CO 2 emissions associated with energy use to satisfy heating, cooling, and lighting needs in buildings. The U.S. Department of Energy (DOE) Building Technologies Office's (BTO's) Emerging Technologies program supports R&D for technologies, systems, and software tools that can contribute to reductions in building energy use. Emerging Technologies funding is distributed competitively through solicitations (e.g., Funding Opportunity Announcements and National Lab Calls, which in general are open to applications from industry, academia, national laboratories, and other entities) and other mechanisms. This document focuses on R&D for windows and window system technologies and will provide guidance for BTO's investments in developing the next generation of high-performance, affordable, cost competitive windows, as well as integrated daylighting and shading technologies in partnership with industry and researchers. This document also addresses areas where DOE invests in software and design tools that translate sophisticated and complex physics into easy-to-use energy performance and optimization methods used by industry and other stakeholders for implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A thorough assessment of China’s standard for energy consumption of buildings

China's Design Standard for Energy Efficiency of Public Buildings (the Design Standard) is widely used in the design phase to regulate the energy efficiency of physical assets (envelope, lighting, HVAC) in buildings. However, the standard does not consider many important factors that influence the actual energy use in buildings, and this can lead to gaps between the design estimates and actual energy consumption. To achieve the national energy savings targets defined in the strategic 12th Five-Year Plan, China developed the first standard for energy consumption of buildings GB/T51161-2016 (the Consumption Standard). This study provides an overview of the Consumption Standard, identifies its strengths and weaknesses, and recommends future improvements. The analysis and discussion of the constraint value and the leading value, two key indicators of the energy use intensity, provide insight into the intent and effectiveness of the Consumption Standard. The results indicated that consistency between China's Design Standard GB 50189-2015 and the Consumption Standard GB/T51161-2016 could be achieved if the Design Standard used the actual building operations and occupant behavior in calculating the energy use in Chinese buildings. The development of an outcome-based code in the U.S. was discussed in comparison with China's Consumption Standard, and this revealed the strengths and challenges associated with implementing a new compliance method based on actual energy use in buildings in the U.S. Overall, this study provides important insights into the latest developments of actual consumption-based building energy standards, and this information should be valuable to building designers and energy policy makers in China and the U.S.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental characterization and potential energy savings of insulated cladding for U.S. residential buildings

This study evaluates a novel insulated cladding composed of foamed cement and vinyl siding that is designed as a retrofit product to enhance thermal performance in U.S. residential buildings. Experimental measurements showed that foamed cement exhibits a thermal conductivity of 0.0334–0.0365 W/m-K (R-value of 4.0–4.3 °F⋅ft 2 ⋅h/BTU), which is significantly higher than that of conventional fiber cement boards. Although mechanical testing confirmed the material’s brittleness and low strength, it also indicated its suitability for nonstructural insulation applications. Water vapor permeability testing demonstrated effective moisture resistance with the polymer coating. To evaluate the insulated cladding’s energy performance, we used the U.S. Department of Energy’s prototype single-family building model and simulated across 50 locations spanning 16 International Energy Conservation Code climate zones. The R-7 (R-value of 7 °F⋅ft 2 ⋅h/BTU per inch) retrofit cladding resulted in heating energy savings up to 275 therms (Fairbanks, AK) and cooling energy savings up to 1,547 kWh (Phoenix, AZ). The energy cost savings varied by region, but the highest annual cost savings ($\$$434/year) were observed in Santa Maria, CA, and the highest annual cost savings percentage (37 %) were noted in Monterey, CA. On a national scale, the insulated retrofit provided an average annual energy cost reduction of 16 %, highlighting the cladding system’s broad applicability and financial viability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of building energy asset rating using stock modelling in the USA

The US Building Energy Asset Score helps building stakeholders quickly gain insight into the efficiency of building systems (envelope, electrical and mechanical systems). A robust, easy-to-understand 10-point scoring system was developed to facilitate an unbiased comparison of similar building types across the country. The Asset Score does not rely on a database or specific building baselines to establish a rating. Rather, distributions of energy use intensity (EUI) for various building use types were constructed using Latin hypercube sampling and converted to a series of stepped linear scales to score buildings. A score is calculated based on the modelled source EUI after adjusting for climate. A web-based scoring tool, which incorporates an analytical engine and a simulation engine, was developed to standardize energy modelling and reduce implementation cost. This paper discusses the methodology used to perform several hundred thousand building simulation runs and develop the scoring scales.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Campbell Creek Research Homes (FY 2012 Annual Performance Report)

The Campbell Creek project is funded and managed by the Tennessee Valley Authority (TVA) Technology Innovation, Energy Efficiency, Power Delivery and Utilization Office. Technical support is provided under contract by the Oak Ridge National Laboratory (ORNL) and the Electric Power Research Institute (EPRI). The project was designed to determine the relative energy efficiency of typical new home construction, energy efficiency retrofitting of existing homes, and high-performance new homes built from the ground up for energy efficiency. This project will compare three houses that represented the current construction practices: a base case (Builder House—CC1); a modified house that could represent a major energy-efficient retrofit (Retrofit House—CC2); and a house constructed from the ground up to be a high-performance home (High Performance House—CC3). To enable a valid comparison, it was necessary to simulate occupancy in all three houses and heavily monitor the structural components and the energy usage by component. All three houses are two story, slab on grade, framed construction. CC1 and CC2 are approximately 2,400 ft 2 . CC3 has a pantry option, primarily used as a mechanical equipment room, that adds approximately 100 ft 2 . All three houses are all-electric (with the exception of a gas log fireplace that is not used during the testing) and use air-source heat pumps for heating and cooling. The three homes are located in Knoxville in the Campbell Creek Subdivision. CC1 and CC2 are next door to each other and CC3 is across the street and a couple of houses down. The energy data collected will be used to determine the benefits of retrofit packages and high-performance new home packages. There are over 300 channels of continuous energy performance and thermal comfort data collection in the houses (100 for each house). The data will also be used to evaluate the impact of energy-efficient upgrades on the envelope, mechanical equipment, and demand-response options. Each retrofit will be evaluated incrementally, by both short-term measurements and computer modeling, using a calibrated model. This report is intended to document the comprehensive testing, data analysis, research, and findings within the January 2011 through October 2012 timeframe at the Campbell Creek research houses. The following sections will provide an in-depth assessment of the technology progression in each of the three research houses. A detailed assessment and evaluation of the energy performance of technologies tested will also be provided. Finally, lessons learned and concluding remarks will be highlighted.

Annual Report↗

Greenbelt Homes Pilot Energy Efficiency Program Phase 1 Summary: Existing Conditions and Baseline Energy Use

A multi-year pilot energy efficiency retrofit project has been undertaken by Greenbelt Homes, Inc, (GHI) a 1,566 co-operative of circa 1930 and '40 homes. The three predominate construction methods of the townhomes in the community are materials common to the area and climate zone including 8” CMU block, wood frame with brick veneer and wood frame with vinyl siding. GHI has established a pilot project that will serve as a basis for decision making for the roll out of a decade-long community upgrade program that will incorporate energy efficiency to the building envelope and equipment with the modernization of other systems like plumbing, mechanical equipment, and cladding.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transition prediction using three dimensional stability analysis

Several methods of transition prediction by linear stability analysis are compared. The spectral stability analysis code SALLY is used to analyze flows over laminar flow control wings. It is shown that transition by the envelope method and a new modified wave packet method are comparable in reliability but that the envelope method is more efficient computationally.

Malik, M. R.↗

Influence of computational fluid dynamics on experimental aerospace facilities: A fifteen year projection

An assessment was made of the impact of developments in computational fluid dynamics (CFD) on the traditional role of aerospace ground test facilities over the next fifteen years. With improvements in CFD and more powerful scientific computers projected over this period it is expected to have the capability to compute the flow over a complete aircraft at a unit cost three orders of magnitude lower than presently possible. Over the same period improvements in ground test facilities will progress by application of computational techniques including CFD to data acquisition, facility operational efficiency, and simulation of the light envelope; however, no dramatic change in unit cost is expected as greater efficiency will be countered by higher energy and labor costs.

Source record↗

Performance of an optimized rotor blade at off-design flight conditions

An investigation is made of the dynamic and aerodynamic performance of a helicopter rotor previously optimized for minimum 4/rev vertical shear and blade weight subject to certain dynamic and structural constraints. The program CAMRAD which was used in designing the optimized blade is used for both dynamic and aerodynamic analaysis. The behavior of the optimized rotor is analyzed over a wide range of operating conditions and for a larger number of rotor characteristics than those considered in designing the blade. To assess the dynamic behavior, the blade root vibratory shears and moments that are transmitted to the rotor hub are calculated. The aerodynamic performance assessments are made based on the power required by the rotor for a given rotor task, the rotor lifting efficiencies, maximum rotor thrust envelopes and the control margins. Results are presented for the optimized blade and the control margins. Results are presented for the optimized blade and the reference blade, which was used as the baseline for the optimized blade, for two rotor tasks.

Chattopadhyay, Aditi↗

Performance of an optimized rotor blade at off-design flight conditions

An investigation is made of the dynamic and aerodynamic performance of a helicopter rotor previously optimized for minimum 4/rev vertical shear and blade weight subject to certain dynamic and structural constraints. The program CAMRAD which was used in designing the optimized blade is used for both dynamic and aerodynamic analysis. The behavior of the optimized rotor is analyzed over a wide range of operating conditions and for a larger number rotor characteristics than those considered in designing the blade. To assess the dynamic behavior, the blade root vibratory shears and moments that are transmitted to the rotor hub are calculated. The aerodynamic performance assessments are made based on the power required by the rotor for a given rotor task, the rotor lifting efficiencies, maximum rotor thrust envelopes and the control margins. Results are presented for the optimized blade and the reference blade which was used as the baseline for the optimized blade, for two rotor tasks.

Chattopadhyay, Aditi↗