Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of Nonflammable Electrolytes for Behind-the-Meter Storage Batteries

Behind-the-Meter Storage (BTMS) is a battery-based, stationary energy storage system that is connected to the residential or industrial customer's side of the electrical grid utility service meter. BTMS systems enable consumers to (A) economically schedule charging and usage of stored energy, (B) store and use energy from on-site generation, especially from inconstant, renewable sources like solar and wind, and (C) avoid overloading the grid during peak hours via supplementation with stored energy. BTMS battery performance requirements and general priorities differentiate from other applications, like EVs, which has prompted the development of batteries with tailored electrode and electrolyte materials. These materials prioritize low cost, avoiding critical materials; longevity, achieving 8000 cycle and 20-year shelf lives; and importantly, high safety. Nonflammable electrolytes show promise to improve safety by mitigating thermal runaway, yet often come with sacrifices to battery performance. In this presentation (1) primary categories of nonflammable electrolytes will be discussed; (2) a rational design of experiment will be presented for efficient performance evaluation of several nonflammables electrolyte in BTMS-relevant battery chemistry, Li4Ti5O12- and LiNi0.90Mn0.10O2; and (3) preliminary results will be presented.

battery↗

A Field Campaign to Study Lightning that Ignites the Bush

The impact of recent wildland fires in the United States and Australia have received much attention in the past several years. As a result, NASA has developed a new Earth Science program to better understand, predict, and manage this phenomenon, as well as a future suborbital mission to studying pyro-cumulonimbus clouds and their effects on the Earth system. In Australia, government and philanthropic stakeholders are supporting a series of field campaigns over the next few years to inform science requirements and advance technology for a future satellite mission to monitor Bushfires. Lightning flashes are a major source of wildland fires, but uncertainties remain about the physical characteristics of lightning and their parent thunderstorms responsible for igniting wildfires. It was long believed that most lightning-ignited wildfires are largely caused by positive flashes to the ground (CGs) and multi-stroke CGs, but a recent study looking at 26-years of NLDN data indicate otherwise. Perhaps this finding is due to statistical chance—there are more negative CGs that occur globally—or perhaps there is some unknown electrical property of the thundercloud from which the igniting flashes emanate. Regardless, new observing strategies are needed. Additionally, long continuing current CGs, which are more likely to ignite a fire, can elude detection by operational ground-based lightning location systems, making it difficult to efficiently identify potential wildland fires and manage them before they have adverse impacts. To address these science and operational gaps, NASA’s Lightning Mapping Array along with electric and magnetic field change meters will be deployed for the Australian Bushfire campaign to document the electrical structure and properties of thunderstorms and lightning that occur in a wildland fire susceptible region. Another aspect of the campaign will be the use of NASA’s airborne lightning observatory, which includes a spectrometer and high-speed imager, to document the radiometric attributes of these flashes coincident with the ground-based RF observations. These observations will be used to better understand the properties of lightning that ignite wildland fires as well as inform design of a lightning detection system for the future Bushfire Monitoring satellite mission.

lightning↗

An analytical method for identifying synergies between behind-the-meter battery and thermal energy storage

Electric utilities build generation capacity to meet the highest demand period, and they often pass on the costs associated with these peaking generators to building owners through demand charges. Building owners can minimize these demand charges by shifting energy use away from peak periods with behind-the-meter storage. This storage can include batteries, which can directly shift the metered load, or thermal energy storage, which can shift thermal-driven electric loads like air conditioning. However, there is a lack of research on how best to combine battery and thermal energy storage. In this study, we develop an analytical sizing method to calculate the potential demand reduction and annualized cost savings for different combinations of thermal and battery energy storage sizes. We show that adding batteries to a thermal energy storage system can increase the total system's load shaving potential. This is particularly true when the building has onsite photovoltaic generation or electric vehicle charging, which add significant variability to the load shape. We also show that for a given total storage size, selecting a higher fraction of thermal energy storage can significantly lower the cycling of the battery, and therefore extend the battery life. This, combined with the expected lower first cost of thermal energy storage materials compared to batteries, shows that hybrid energy storage systems can outperform a standalone battery or standalone thermal storage system. Assuming the thermal storage has a capital cost 6x lower than the battery, our analysis shows that the optimal system is 71% thermal energy storage and 29% battery energy storage for a scenario with electric vehicle charging. The annualized cost savings for this system are $48.6 k/yr, whereas an equivalently sized standalone thermal energy storage system would provide annualized cost savings of $28.5 k/yr and a standalone battery would lead to savings of $8.72 k/yr. The hybrid system also reduces battery cycling by 52% compared to a standalone battery, extending battery lifetime.

25 ENERGY STORAGE↗

Transition to turbulence in solar surges

Transition to turbulence in magnetohydrodynamic (MHD) tearing jets has been invoked as a mechanism underlying some of the complex behavior observed in solar surges, including deceleration of the upflowing plasma and temporal correlations with types I and III radio bursts. In this paper we investigate a possible mechanism for this transition: three-dimensional secondary instabilities on two-dimensional saturated states. We find through linear analysis that these MHD configurations -- in particular, the tearing jet -- are secondarily unstable, with the dominant energy transfer from the one-dimensional field into the 3-dimensional fields. Using nonlinear simulations, we also investigate the system evolution after the secondary modes attain finite amplitude. When the tearing jet transitions to turbulence, the total kinetic energy drops rapidly corresponding to the deceleration of the jet. The electric field grows rapidly as the primary mode saturates and the three-dimensional secondary mode develops, and then decays quickly as the tearing jet becomes turbulent, providing a possible explanation for the finite duration of the associated meter-wave bursts. The electric field decays as the magnetic and velocity fields both decay. The system is dominated at late times by spanwise modes, which strongly resemble the magnetic field-aligned filamentary flows characteristic of many surges.

Dahlburg, Russell B.↗

Instrumentation for Assessing DC Electrical Distribution Systems in Buildings

Direct current (DC) distribution systems is emerging as a favorable option over alternating current in buildings due to its energy and non-energy benefits (e.g., efficiency, resilience, safety). However, limited guidelines exist to evaluate the DC electrical distribution infrastructure. This paper aims to fill that gap by detailing our experience with metering a building-level electrical DC distribution system. Our case study is a DC microgrid at the Direct Energy Partners Research & Development facility located in Charlotte, North Carolina. This paper presents our approach, technical challenges, and lessons learned with DC metering and instrumentation.

buildings↗

Key Observations and Discoveries from the Vector Electric Field Investigation on the C/NOFS Satellite

Launched in 2008 and operating for 7.5 years, the Air Force Communication /Navigation Outage Forecasting System (C/NOFS) satellite included the Vector Electric Field Investigation (VEFI) designed and built at NASA’s Goddard Space Flight Center. VEFI successfully met its objectives: 1) investigate the role of ambient electric fields in initiating nighttime density depletions and turbulence; 2) determine the quasi-DC electric fields associated with abrupt density depletions, and 3) quantify the spectrum of the irregularities associated with density depletions, providing many key observations and discoveries including: -- Global (low latitude) vector DC electric fields at 16 s/sec revealing variations with local time, longitude, and season between extremely low and moderate solar activity-- Reversed zonal E x B drifts below the F-region ledge at sunset and simultaneous observations of large scale Kelvin-Helmholtz instabilities as seeds of spread-F -- Large expanses of quasi-coherent kilometer-scale vector wave observations (electric field and density) below 450 km and their discovery as a source of scintillations using the C/NOFS GPS -- Reversed zonal DC electric fields and simultaneous observations of afternoon counter electrojet-- Enhanced zonal DC electric fields at sunrise and full vector plasma flow continuity at the terminator-- Vector electric field and density irregularities extending to meter-scales within equatorial plasma depletions -- Intense electric field structure within the equatorial ionosphere at night in the absence of density depletions -- First observations of the westward equatorial electrojet in post-midnight ionosphere and possible association with downward meridional drifts-- Spaceborne Dst observations and implications for ring current asymmetries-- Vector electric and magnetic field Poynting flux within depletions and TIDs-- Measurements of ionospheric reflectance and Alfvenic waves associated with TIDs-- Observations of Alfven resonators -- ULF magnetic field structure within the nightime equatorial ionosphere-- Discovery of Schumman resonances in space and implications of ELF radiowave propagation-- Vector observations of 50-60 Hz powerline radiation without harmonics-- Ion cyclotron resonance absorption lines associated with ELF hiss and the identification of ambient ions-- Parallel electric fields associated with lower hybrid waves driven by thunderstorm lightning-related sferics-- Discovery of Z-mode radiation in the equatorial ionosphere including its associated with density depletions-- Optical lightning detector waveforms and electric field sferics observed up to altitudes of 800 km

Robert F Pfaff↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗

Financial Impacts of Net-Metered Distributed PV on a Prototypical Western Utility’s Shareholders and Ratepayers

Distributed solar photovoltaic (DPV) under net-energy metering with volumetric retail electricity pricing has raised concerns among utilities and regulators about adverse financial impacts for shareholders and ratepayers. Using a pro forma financial model, we estimate the financial impacts of different DPV deployment levels on a prototypical Western U.S. investor-owned utility under a varied set of operating conditions that would be expected to affect the value of DPV. Our results show that the financial impacts on shareholders and ratepayers increase as the level of DPV deployment increases, though the magnitude is small even at high DPV penetration levels. Even rather dramatic changes in DPV value result in modest changes to shareholder and ratepayer impacts, but the impacts on the former are greater than the latter (in percentage terms). The range of financial impacts are driven by differences in the amount of incremental capital investment that is deferred, as well as the amount of incremental distribution operating expenses that are incurred. While many of the impacts appear relatively small (on a percentage basis), they demonstrate how the magnitude of impacts depend critically on utility physical, financial, and operating characteristics.

14 SOLAR ENERGY↗

Decarbonizing all-electric communities via carbon-responsive control of behind-the-meter resources

The progression of electrification in the building and transportation sectors brings new opportunities for energy decarbonization. With higher dependence on the grid power supply, the variation of the grid carbon emission intensity can be utilized to reduce the carbon emissions from the two sectors. Existing coordinated control methods for buildings with distributed energy resources (DERs) either consider electricity price or renewable energy generation as the input signal, or adopt optimization in the decision-making, which is difficult to implement in the real-world environment. This paper aims to propose and validate an easy-to-deploy rule-based carbon responsive control framework that facilitates coordination between all-electric buildings and electric vehicles (EVs). The signals of the grid carbon emission intensity and the local photovoltaics (PV) generation are used for shifting the controllable loads. Extensive simulations were conducted using a model of an all-electric mixed-use community in a cold climate to validate the control performance with metrics such as emissions, energy consumption, peak demand, and EV end-of-day state-of-charge (SOC). Our study identifies that 4.5% to 27.1% of annual emission reduction can be achieved with limited impact on energy costs, peak demand, and thermal comfort. Additionally, up to 32.7% of EV emission reduction can be obtained if the EV owners reduce the target SOC by less than 21.2%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data-Driven Voltage Control Strategy for Distribution Grids With Distributed Energy Resources

Traditionally, distribution system control approaches have been model-based. The deployment of advanced metering infrastructure has provided electric utilities with the capability of data-driven control with real-time measurements. The shift from model-based to data-driven control represents a significant advancement in the management of distribution systems, offering a more adaptive approach to system control because of the ability to dynamically adapt to changing conditions without the need for system modeling. Here, in this paper, a behavioral data-driven control method is developed to provide voltage regulation to an actual distribution system by controlling the legacy devices and distributed energy resource (DER) assets. The studied distribution system has a load tap changer and three capacitor banks as the legacy devices and photovoltaic systems as the DERs. The performance of the proposed control algorithm is validated using a laboratory test bed setup considering multiple scenarios. The results show that the proposed control achieved 99% voltage regulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Guide for Distributed Wind

Distributed wind sits at the intersection of grid-connected, off-grid and behind-the-meter cyber-physical electrical energy systems. The unique physical properties and communications requirements for distributed wind systems mean that there are unique cybersecurity considerations, but there is little to no existing guidance on best practices for cybersecurity. This document is intended to be a starting point for distributed wind stakeholders including manufacturers, installers and integrators, and operators (facility, aggregator, or utility). We discuss common distributed wind architectures and describe their role in the larger power system, pointing out some of the key connections to be aware of. Cybersecurity cannot exist in a vacuum, but rather must consider all the system and all its connections holistically. The role of distributed wind and the functions it can serve are described to gain understanding of the full range of capabilities. The purpose and application of relevant standards that may apply to certain distributed wind systems is presented. These standards may not apply to all installations, but even for systems that are not required to meet these standards they can be a good reference for best practices. A holistic threat perspective is used to describe the adversaries, threats, and potential impacts of cyberattacks, with special emphasis on what sets distributed wind systems apart from other distributed energy resources (DER). Finally, we present the recommendations for cybersecurity, both in terms of needs of the system and roles that specific stakeholders should fulfill. Distributed wind systems can come in a variety of architectures and applications, so there is no one-size-fits-all approach to cybersecurity. However, this document contains the relevant information for stakeholders to identify the cybersecurity needs of their system, refer to relevant standards, and apply best practices in a manner most consistent with their security and operational goals.

17 WIND ENERGY↗

Introduction to Voigt's wind power plant

The design and operation of a 100 kilowatt wind driven generator are reported. Its high speed three-bladed turbine operates at a height of 50 meters. Blades are rigidly connected to the hub and turbine revolutions change linearly with wind velocity, maintaining a constant speed ratio of blade tip velocity to wind velocity over the full predetermined wind range. Three generators installed in the gondola generate either dc or ac current. Based on local wind conditions, the device has a maximum output of 720 kilowatts at a wind velocity of 16 meters per second. Total electrical capacity is 750 kilowatts, and power output per year is 2,135,000 kilowatt/hours.

Tompkin, J.↗

Nighttime observations of thunderstorm electrical activity from a high altitude airplane

Photographs from a NASA U-2 airplane flying over nocturnal thunderstorms show frequent lightning activity in the upper part of the cloud. In some cases, unobscured segments of lightning channels 1 km or longer are visible in clear air around and above the cloud. Multiple images of lightning channels indicate multiple discharges in the same channel. Photographs taken through a diffraction grating show that the lightning has a spectrum similar to that observed in the lower troposphere. Lightning spectra obtained with a slitless line-scan spectrometer show strong singly ionized nitrogen emissions at 463.0 and 500.5 nm. Field changes measured with an electric field-change meter correlate with pulses measured with a photocell optical system. Optical signals corresponding to dart leader, return stroke, and continuing current events are readily distinguished in the scattered light emerging from the cloud surface. The variation of light intensity with time in lightning events is consistent with predicted modification of optical lightning signals by clouds. It appears that satellite based optical sensor measurements cannot provide reliable information on current rise times in return strokes. On the other hand, discrimination between cloud-to-ground and intracloud flashes and the counting of ground strokes is possible using the optical pulse pairs which have been identified with leader, return-stroke events in the cloud-to-ground flashes studied.

Brook, M.↗

Ion-neutral Coupling During Deep Solar Minimum

The equatorial ionosphere under conditions of deep solar minimum exhibits structuring due to tidal forces. Data from instruments carried by the Communication Navigation Outage Forecasting System (CNOFS) which was launched in April 2008 have been analyzed for the first 2 years following launch. The Planar Langmuir Probe (PLP), Ion Velocity Meter (IVM) and Vector Electric Field Investigation (VEFI) all detect periodic structures during the 20082010 period which appear to be tides. However when the tidal features detected by these instruments are compared, there are distinctive and significant differences between the observations. Tides in neutral densities measured by the Gravity Recovery and Climate Experiment (GRACE) satellite were also observed during June 2008. In addition, Broad Plasma Decreases (BPDs) appear as a deep absolute minimum in the plasma and neutral density tidal pattern. These are co-located with regions of large downward-directed ion meridional velocities and minima in the zonal drifts, all on the nightside. The region in which BPDs occur coincides with a peak in occurrence rate of dawn depletions in plasma density observed on the Defense Meterological Satellite Program (DMSP) spacecraft, as well as a minimum in radiance detected by UV imagers on the Thermosphere Ionosphere Mesosphere Energetics and Dynamics (TIMED) and IMAGE satellites

IVM↗

Cybersecurity Guide for Distributed Wind Presentation

This presentation communicates information about the MIRACL project Resilience Metrics report and Resilience Framework report. It was created for the 2021 MIRACL advisory board meeting. Distributed wind sits at the intersection of grid-connected, off-grid and behind-the-meter cyber-physical electrical energy systems. The unique physical properties and communications requirements for distributed wind systems mean that there are unique cybersecurity considerations, but there is little to no existing guidance on best practices for cybersecurity. This presentation is intended to be a starting point for distributed wind stakeholders including manufacturers, installers and integrators, and operators (facility, aggregator, or utility). A holistic threat perspective is used to describe the adversaries, threats, and potential impacts of cyberattacks, with special emphasis on what sets distributed wind systems apart from other distributed energy resources (DER). We present the recommendations for cybersecurity, both in terms of needs of the system and roles that specific stakeholders should fulfill. Distributed wind systems can come in a variety of architectures and applications, so there is no one-size-fits-all approach to cybersecurity. However, this document contains the relevant information for stakeholders to identify the cybersecurity needs of their system, refer to relevant standards, and apply best practices in a manner most consistent with their security and operational goals.

17 WIND ENERGY↗

Characterizing patterns and variability of building electric load profiles in time and frequency domains

The rapid development of advanced metering infrastructure provides a new data source—building electrical load profiles with high temporal resolution. Electric load profile characterization can generate useful information to enhance building energy modeling and provide metrics to represent patterns and variability of load profiles. Such characterizations can be used to identify changes to building electricity demand due to operations or faulty equipment and controls. In this study, we proposed a two-path approach to analyze high temporal resolution building electrical load profiles: (1) time-domain analysis and (2) frequency-domain analysis. Furthermore, the commonly adopted time-domain analysis can extract and quantify the distribution of key parameters characterizing load shape such as peak-base load ratio and morning rise time, while a frequency-domain analysis can identify major periodic fluctuations and quantify load variability. We implemented and evaluated both paths using whole-year 15-minute interval smart meter data of 188 commercial office building in Northern California. The results from these two paths are consistent with each other and complementary to represent full dynamics of load profiles. The time- and frequency-domain analyses can be used to enhance building energy modeling by: (1) providing more realistic assumptions about building operation schedules, and (2) validating the simulated electric load profiles using the developed variability metrics against the real building load data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Orbiter environment at S- and Ku-band frequencies

Detailed measurements of the electric field strength associated with the Ku-band radar and S-band communication link were made by the Plasma Diagnostics Package (PDP) on STS 51F. These measurements were made while the PDP was attached to the Remote Manipulation System arm and again while the PDP was released as a subsatellite. The results indicate that cargo elements that remain inside of the scan limits of the radar should experience fields less than 2 V/m and that elements that may encounter the main beam can use 300 V/m as a design guideline with adequate safety margin. S-band fields tended to be several dB lower than worst-case predictions. Safe design practice indicates that an electric field E = 100/r (r in meters) should be used as a guideline for deployable systems. S-band electric fields within the cargo bay envelope should be less than 2 V/m even with edge diffraction effects and reflections from other payloads taken into account. The absolute accuracy of these measurements is about 2 dB.

Murphy, G. B.↗