Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Electrical Fault Detection, Power Quality, Distributed Energy Resource Use Cases, and Cyber Event Applications with the Cyber Grid Guard System Using Distributed Ledger Technology

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation and are associated with distributed energy resources (DERs). The integrity and confidentiality of data from IEDs is crucial, and distributed ledger technology (DLT) could improve the resilience of microgrids by helping to make these data more secure. The most popular applications using blockchain technology for electrical utilities is in the field is based on energy trading. However, the dynamism of the penetration of customer owned DERs and the deployment of sensors with IEDs have led to the identification of new applications using DLT that are focused on other areas, such as monitoring, operation and management of the grid and its assets. In addition, the majority of studies on electrical grid applications with blockchain were validated with software simulations. Although general monitoring of power systems for using DLT could be evaluated in operational electric grids, other DLT research applications such as defense against cyber-attacks and/or electrical fault detection are not likely to be performed in a real infrastructure because of possible risks to the network/equipment security. This report summarizes the application of power system applications using distributed ledger technology (DLT), providing a secure DLT framework for collecting data from IEDs like power meters and protective relays inside and outside of an electrical substation and/or between two different electrical utilities. In this study, the use case scenarios were created and assessed for different power system application by using DLT. The electrical fault detection for faulted phases (1), power quality monitoring of phase voltage magnitudes, frequency levels and load power factor (2), DERs use case monitoring (3), and cyber-event applications (4) were performed in a test bed with a Cyber-Grid Guard (CGG) system using DLT. It had a real-time simulator with power meters and protective relays in-the-loop. The first section of this report presents a literature review of power system applications using blockchain at research level. The second section shows the theory and equations used on this report. The third section shows the description of the test bed, equipment, architecture, and electrical grid diagrams. The fourth section shows the experimental models and use case scenarios that were performed for the electrical fault detection, power quality, DERs use case, and cyber event applications with the CGG system using DLT. The fifth section shows the results collected from the tests based on comparing the time stamped events of the analog signals from the IEDs, DLT computer and real time simulator. The sixth section performed the discussion of the results for the use case scenarios. Finally, section seven presents the conclusions for this report were presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Joint Estimation of Behind-the-Meter Solar Generation in a Community

Distribution grid planning, control, and optimization require accurate estimation of solar photovoltaic (PV) generation and electric load in the system. Most of the small residential solar PV systems are installed behind-the-meter making only the net load readings available to the utilities. This paper presents an unsupervised framework for joint disaggregation of the net load readings of a group of customers into the solar PV generation and electric load. Our algorithm synergistically combines a physical PV system performance model for individual solar PV generation estimation with a statistical model for joint load estimation. The electric loads for a group of customers are estimated jointly by a mixed hidden Markov model (MHMM) which enables modeling the general load consumption behavior present in all customers while acknowledging the individual differences. At the same time, the model can capture the change in load patterns over a time period by the hidden Markov states. The proposed algorithm is also capable of estimating the key technical parameters of the solar PV systems. Our proposed method is evaluated using the net load, electric load, and solar PV generation data gathered from residential customers located in Austin, Texas. Testing results show that our proposed method reduces the mean squared error of state-of-the-art net-load disaggregation algorithms by 67%.

behind-the-meter solar generation↗

Advanced Multi-Dimensional Capacitance Sensors Based Subsea Multiphase Mass Flow Meter to Measure and Monitor Offshore Enhanced Oil

This innovation is based on advanced multi-dimensional extensions of ECVT sensors that involve ECVT, Displacement Current Phase Tomography (DCPT), Maxwell-Wagner-Sillars polarization effect (MWS), and velocimetry which exploit the variation of electric properties between the oil, water, and gas coming out of the well. Capacitance sensors are embedded on the inside of a pipe spool and placed in-line with the subsea oil line piping on the extraction end of the well. The difference in dielectric, dielectric loss, surface polarization, and velocity of each phase are used in the multi-dimensional algorithm to measure the volume fraction, distribution, velocity, mass flow rate, and flow regime of the mixture moving through the pipe.

02 PETROLEUM↗

The Uniform Methods Project: Smart Thermostat Evaluation Protocol

A smart thermostat is an internet-connected device that controls home heating, ventilation, and air-conditioning (HVAC) equipment and can automatically adjust temperature set points to optimize performance and achieve energy savings. Smart thermostat features often include two way communication, occupancy detection (such as geofencing and occupancy sensors), schedule learning, and seasonal optimization algorithms. Smart thermostats can control most conventional HVAC systems, including central air conditioners, heat pumps, and forced air furnaces. Several types of residential utility programs offer smart thermostats as replacements measures. Working with smart thermostat vendors, utilities can offer separate optimization programs to produce energy savings beyond those achieved by installing a smart thermostat. From an evaluation perspective, smart thermostat programs have several noteworthy features. First, the energy savings from a smart thermostat may change over the life of the device. As a smart thermostat is connected to the internet, original equipment manufacturers can update the thermostat software to improve the thermostat's energy efficiency. Likewise, users can adjust the thermostat settings and schedules over time in response to changes in weather, thermal comfort, energy prices, or preferences for energy efficiency. Additionally, many thermostat manufacturers offer seasonal optimization programs that recommend changes or make minor, automated adjustments to the thermostat settings to improve energy efficiency. These opt-in programs are now standard offerings for many smart thermostat manufacturers and provided at no additional cost to users. The potential for software updates and continuous optimization and the evolving nature of user interactions mean future energy savings may differ from first-year savings and the energy savings of smart thermostats may need to be evaluated more than once. Second, smart thermostats often have small unit energy savings relative to a home's total energy consumption, especially in comparison to whole- home retrofit programs. This can make it difficult to detect the smart thermostat savings in billing or advanced metering infrastructure (AMI) meter consumption data. For example, as cooling loads in many regions average about 20% of annual electricity consumption, smart thermostat savings of 10% of cooling energy use would equate to a 2% reduction in home electricity consumption. Evaluators should use regression analysis of whole-home billing consumption or advanced metering infrastructure (AMI) meter consumption data to evaluate smart thermostat savings because, as explained at greater length below , these data are usually available to evaluators and regression can control for the impacts of weather and other potentially confounding factors on a home's energy consumption. Finally, as with other energy efficiency programs, participation in smart thermostat programs is self-selective. As discussed at greater length below , smart thermostat participants tend to be, among other things, younger, higher-income, and more likely to adopt electric vehicles (EVs) and internet connected devices than nonparticipants. These differences are often unobservable to the evaluator and correlated with a home's energy consumption, creating the potential for bias in estimating savings. Due to the small unit savings of thermostats, errors and biases from self-selection that may not be very consequential when evaluating a whole- home retrofits (e.g., ±2% of home electricity consumption) can have a major impact when evaluating the savings and cost-effectiveness of smart thermostat programs. A percentage point change in the estimated savings could affect the cost-effectiveness of a program. This means it is important for evaluators to assess and to minimize the potential for error from selection bias in estimating smart thermostat program savings. The Uniform Methods Project provides model protocols for determining energy savings and demand reductions that result from specific energy efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol ; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The UMP protocols can be used by utilities, program administrators, public utility commissions, evaluators, and other stakeholders for both program planning and evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Floating Solar at Lima's Twin Lakes Reservoir

The City of Lima, Ohio is developing a floating photovoltaic (FPV) facility on the surface of Twin Lake Reservoir, adjacent to the City’s water treatment plant. The FPV array is designed with a capacity of 2 megawatts (MW) and will consist of approximately 3,500 solar panels spanning more than four acres of water surface. Based on regional solar conditions, the system will generate 2,000 megawatt-hours (MWh) of electricity annually. While the FPV system will interconnect to the electrical infrastructure serving the water treatment plant, power produced by the system will be net-metered through the utility grid, with energy credits applied to offset the plant’s overall electrical demand rather than directly supplying all plant loads in real time.

14 SOLAR ENERGY↗

Welcome to the Special Issue on Grid-Edge Computing With Behind-the-Meter Resources [Guest Editorial]

The integration of distributed energy resources (DERs), such as solar photovoltaic systems, as well as other synergistic assets, including electric vehicles, energy storage, and smart appliances, in electric power systems has been dramatically increasing in the past few years. These assets have the capability to provide much-needed flexibility to electric power systems for improved grid reliability, resilience, and economic efficiency; however, most of these resources are located behind the meter (BTM) on customer premises, and their flexibility is not fully used in current grid operations. Grid-edge computing plays an important role in unlocking the great benefits and potential that BTM resources could provide to electric power systems by enhancing visibility and controllability at the grid edge.

behind-the-meter resources↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper presents the analysis which help visualize the DER impact on the grid, identify the challenges and provides an insight into the new distribution management and control needs to enable reliable and resilient grid operations.

behind-the-meter↗

Consumer Benefits of Clean Energy: Renewable Energy

Meeting national and state decarbonization goals requires a transition to clean energy technologies. Energy efficiency, demand flexibility, renewable energy and storage can reduce consumers’ electricity bills, lower total electricity system costs, and provide health and resilience benefits. Berkeley Lab developed a series of briefs that explore these consumer benefits of a clean energy transition. This brief discusses some of the possible consumer benefits of utility-scale and behind the meter renewable energy, with a focus on how these resources can contribute to a low-cost electricity system. It begins with a literature review of modeled impacts, primarily considering consumer benefits, of the Inflation Reduction Act and Bipartisan Infrastructure Law. Next, it discusses how utility-scale renewable energy can contribute to a low-cost electricity system (e.g., in some cases, low resource costs relative to other alternatives). It concludes with a discussion of behind-the-meter renewable energy consumer benefits (e.g., reduced host electricity bill, increased property value, resilience).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Supply Chain Management in Cyber Grid Guard Framework

Grid modernization has impeded innovative power grid applications and energy resources that are increasingly distributed. Blockchain/distributed ledger technology (DLT) has the potential to enhance the resilience of the electric infrastructure, particularly in a decentralized and distributed environment. The benefits of blockchain are to ensure asset information and lifecycle events are secure and traceable and identify potential malicious modification of data. Oak Ridge National Laboratory (ORNL) has developed a framework, Cyber Grid Guard (CGG), incorporating blockchain. The system implements a low-energy, fast, and robust enhancement to system trustworthiness within and across electric grid systems, including substations, control centers, and metering infrastructures. Currently, one of the major concerns is supply chain attacks. There have been several recent attacks that have significantly impacted critical infrastructures and organizations around the world. This document focuses on how CGG can be used to address the supply chain issue.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Oak Ridge National Laboratory Pilot Demonstration of an Attestation and Anomaly Detection Framework using Distributed Ledger Technology for Power Grid Infrastructure

This report summarizes the design and pilot demonstration of a framework called Grid Guard that was created to provide increased data and device trustworthiness to electric grid devices by leveraging distributed ledger technology (DLT), specifically blockchain. Grid Guard contains a combination of core cryptographic methods such as the secure hash algorithm (SHA), and asymmetric cryptography, private permissioned blockchain, baselining configuration data, consensus algorithm (Raft) and the Hyperledger Fabric (HLF) framework. The system implements a low energy, fast, and robust enhancement to system trustworthiness within and across electric grid systems such as substations, control centers and metering infrastructures. Blockchain is a distributed database structured that provides a practically unalterable (immutable) timeline of stored transactions. By relying on hashing and the Raft consensus algorithm, if an entity tries to illegitimately alter a record at one instance of the database the other ledger nodes are not altered. They work to cross-reference each other and easily locate any incorrectly added data and remove it. The bulk raw data is stored in an off-chain storage (outside of the blockchain ledger) and a hash of this baseline data is stored in the Blockchain ledger via hashing windows of time-series and configuration data, after aggregation and filtering. The bulk off-chain data repository is then considered to be trust-anchored using the hashes stored in the blockchain. To secure the electric grid testbed devices and data, device configuration baselines were compared to those baselines that had been previously stored in the ledger. Statistical baselines for device configurations, network communication patterns, and high-speed sensor data are calculated and then stored off-chain and hashes stored in the ledger. Measurements such as three-phase voltage and current, frequency, breaker status, protection scheme settings, network configuration settings (and other device configuration artifacts) and network traffic features (packet interarrival times) are compared every minute or other selected time windows. During phase 1 of the Grid Guard DLT project different DLT technologies were studies, and an assessment was performed on DLT technology vulnerabilities, uses, and key characteristics. DLT consensus protocols were studies (e.g., RAFT, named after Reliable, Replicated, Redundant, And Fault-Tolerant). Also, cryptography, public, private and permissioned or permissionless systems were assessed. Grid Guard implements a permissioned private DLT. Consensus algorithm selection and choice of DLT implementation depended heavily on the use-case. For this use-case, parameters were selected to measure performance and existing tools for assessment. Benchmarking was performed theoretically and practically. During phase 2 hashed transactions/blocks were inserted into the ledger every second. During phase 2 of the Grid Guard DLT project, a prototype framework was developed and demonstrated for attestation of critical substation devices and data using precision timing systems that use PTP and IRIG-B protocols) on a testbed of operational devices that emulated a distribution substation, control center, and power metering infrastructure using real Operational Technology (OT). The testbed includes OT devices such as protective relays, human machine interfaces (HMI), and power meters. To determine when to collect and compare system and network baselines, an initial examination of an anomaly detection capability to identify malicious manipulation of data streams was conducted. The resulting anomaly detection was demonstrated in a set of experiments and leveraged to trigger device artifact attestation checks. Attestation checks occur against device configuration baselines when compared with the immutable blockchain-stored baselines, which provided a cryptographically supported means by which to store baselines. The electrical substation-grid testbed was created to test the Grid Guard framework. The testbed emulates the operations of a portion of a power grid and SCADA systems as closely as possible. The testbed integrates real protocols, mainly IEC 61850 standard protocols, such as the Sampled Value (SV) and the GOOSE protocols. The testbed also supports DNP3 and other layer 2 and layer 3 protocols such as Telnet, SSH, SFTP/FTP and other proprietary protocols needed to connect to industrial control system equipment. The testbed emulates real power conditions using the OpalRT hardware-in-the-loop (HIL) device which can create fault situations that cannot be easily tested on real systems. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that electrical utilities commonly use.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wind Turbine Sound Setbacks and Supply Curves: Ordinances and Extrapolated Trends, 110 Hub Height, 130 Rotor Diameter

This dataset provides a comprehensive set of wind turbine sound setbacks from every residential structure in the contiguous United States (CONUS). A sound setback is defined as the minimum required distance between a residential structure and a hypothetical turbine installation site to ensure that modeled sound levels received at the residence do not exceed local sound ordinances, which are commonly expressed in A-weighted decibels (dBA). Therefore, sound setbacks are a local spatial assessment combining multiple factors, including the sound pressure curve as a function of the observer location (distance and direction) relative to the turbine, local sound regulations, and the geographical distribution of residential structures. The dataset is organized into multiple scenario-based products, detailed as follows: 1. Existing and extrapolated sound setbacks. An existing scenario characterizes sound setbacks only in states or counties that have implemented sound regulations as of 2022. The extrapolated scenarios extend a constant sound threshold to counties that lack explicit sound regulations, with thresholds ranging from 35 to 60 dBA, in 5-dBA increments reflecting the variation observed in current sound ordinances. 2. Sound setbacks in directional and worst scenarios. The directional scenario accounts for the distance and orientation of residential structures relative to a hypothetical turbine location, utilizing the turbine's sound emissions in that specific direction. In contrast, the worst scenario takes loudest sound level at each distance step from the turbine, irrespective of directional considerations, which aligns with current industry practice. 3. Supply curves for Open and Reference Access scenarios. This dataset includes supply curves generated by the reV model, which integrates each of the above sound setbacks into both Open and Reference siting scenarios. In addition, two Open and Reference baselines scenarios were included which do not consider sound setbacks for comparative analysis. All sound setback data are stored in TIF files, with partial maps of the data provided in PNG format. The values in the sound setback raster range from 0 to 1, representing the fraction of developable land within a 90 meter by 90 meter pixel due to sound ordinances. A value of 0 indicates areas where wind energy development is prohibited, while a value of 1 signifies areas fully permissible. The wind turbine parameters used in the sound modeling are based on the land-based turbine from International Energy Agency (IEA), featuring a rated electrical power of 3.4 MW, a rotor diameter of 130 meters, and a hub height of 110 meters. The atmospheric conditions, including wind speed/direction, turbulence, air temperature, relative humidity, and air pressure, that drive the sound generation are obtained from the WIND Toolkit dataset.

Array↗

Grid Edge Visibility: Gaps and a Road Map

Behind-The-Meter (BTM) resources at the grid edge are rapidly becoming an important component of the electric grid, requiring a substantial reconfiguration of traditional grid practices, such as policy changes, market redesign, and infrastructure upgrades. This adjustment is challenged by the fact that, by definition, grid edge elements are not easily observable by grid control entities. Increasing the visibility of these resources is therefore an important goal, one that is experiencing much research and discussion by various power system stakeholders. For example, policy makers are analyzing the tradeoffs of using grid edge meters to impose charges on grid edge electricity generation. System operators, such as the Midcontinent Independent System Operator (MISO) in the United States, can identify visibility information on the electrical location and the size of the grid edge resources as a critical consideration across the transmission-and-distribution (T&D) spectrum. This article summarizes the challenges and needs of grid entities resulting from the introduction of grid edge resources as well the gaps in the extant grid edge visibility frameworks.

behind-the-meter↗

Behind-the-Meter Storage [Slides]

This is an overview of the work happening with Behind-the-Meter Storage. NREL is the Project Lead for Behind-the-Meter storage. The goal of this research is to produce behind-the-meter battery solutions deployed at scale to meet the functional requirement of high-power electric-vehicle charging.

25 ENERGY STORAGE↗

Calibration of urban building energy model using smart meter data for district peak load prediction

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level.

AMI data↗

Abatement of ionizing radiation for superconducting quantum devices

Ionizing radiation has been shown to reduce the performance of superconducting quantum circuits. In this report, we evaluate the expected contributions of different sources of ambient radioactivity for typical superconducting qubit experiment platforms. Our assessment of radioactivity inside a typical cryostat highlights the importance of selecting appropriate materials for the experiment components nearest to qubit devices, such as packaging and electrical interconnects. We present a shallow underground facility (30-meter water equivalent) to reduce the flux of cosmic rays and a lead shielded cryostat to abate the naturally occurring radiogenic gamma-ray flux in the laboratory environment. We predict that superconducting qubit devices operated in this facility could experience a reduced rate of correlated multi-qubit errors by a factor of approximately 20 relative to the rate in a typical above-ground, unshielded facility. Finally, we outline overall design improvements that would be required to further reduce the residual ionizing radiation rate, down to the limit of current generation direct detection dark matter experiments.

47 OTHER INSTRUMENTATION↗

Search for continuous gravitational wave signals from luminous dark photon superradiance clouds with LVK O3 observations

Superradiance clouds of kinetically mixed dark photons around spinning black holes can produce observable multimessenger electromagnetic and gravitational wave signals. The cloud generates electric fields of up to a teravolt-per-meter, which leads to a cascade production of charged particles, yielding a turbulent quasiequilibrium plasma around the black hole, and resulting in electromagnetic fluxes ranging from supernova to pulsar-like luminosities. For stellar mass black holes, such systems resemble millisecond pulsars and are expected to emit pulsating radio waves and continuous gravitational waves (CWs) within the LIGO-Virgo-KAGRA (LVK) sensitivity band. We select 44 sources with approximately coincident frequencies or positive frequency drifts from existing pulsar catalogs as potential candidates of long-lasting superradiance clouds around old Galactic black holes. For a subset of 34 sources that are well measured and have not been previously targeted, we perform the first search for CW emission in LVK data from the third observing run. We find no evidence of a CW signal and place 95% confidence level upper limits on the emitted strain amplitude. We interpret these results, together with limits from previous searches, in terms of the underlying dark photon theory by performing an analysis of the expected signals from superradiance clouds from Galactic black holes. Finally, we find that, even for moderately spinning black holes, the absence of an observed CW signal disfavors a discrete set of dark photon masses between about 10 −13 and 10 −12 eV/c 2 and kinetic mixing couplings in the range of 10 −9 –10 −7 , subject to assumptions about the properties of the black hole population and the cloud’s electromagnetic emission.

astronomical black holes↗

Optimal Efficiency and Operational Cost Savings: A Framework for Automated Rooftop PV Placement

Residential energy consumers are charged based on a utility rate structure, such as net metering or feed-in tariff. To lower consumers' electricity bills, expensive batteries are deployed to reduce the electricity fed from the grid during peak hours. However, strategic photovoltaic (PV) panel placement enables the reduction of operational energy cost while considering the spatial feasibility and efficiency for hosting rooftop PV. In this paper, we present a framework to automatically identify the optimal location of rooftop PV panels on residential buildings. Our framework integrates multiple workflows, including energy and environmental simulation, parametric modeling, and optimization to identify the ideal location of PV panels to balance the demand and supply at a building and community scale. These workflows are linked using the Grasshopper plug-in for Rhinoceros CAD software. The framework includes two different workflows, each satisfying a target for optimal PV placement: (a) maximizing PV panel efficiency, where users aim to maximize energy generation, and (b) minimizing operational energy cost, where "best'' panels are selected considering utility rates for operational energy cost. Our framework is demonstrated in a residential community in Fort Collins, Colorado, to generate the optimal PV placement for each of the two aforementioned targets. Results from the two workflows are compared to illustrate the effect of PV location and orientation on solar energy production efficiency and operational energy cost. The developed workflows are introduced as tools within the Grasshopper plug-in to investigate the solar potential of rooftop PV panels while taking into account factors such as contextual shading, utility rate structures, and buildings' energy demand profiles.

30 DIRECT ENERGY CONVERSION↗