At least 127 records · Page 7

Electrochemical aptamer-based sensors: leveraging the sensing platform for minimally-invasive microneedle measurements and fundamental exploration of sensor biofouling dynamics

The ability to track the concentrations of specific molecules in the body in real time would significantly improve our ability to study, monitor, and respond to diseases. To achieve this, we require sensors that can withstand the complex environment inside the body. Electrochemical aptamer-based sensors are particularly promising for in vivo sensing, as they are among the only generalizable sensing technologies that can achieve real-time molecular monitoring directly in blood and the living body. In this project, we first focused on extending the application space of aptamer sensors to support minimally-invasive wearable measurements. To achieve this, we developed individually-addressable sensors with commercial off-the-shelf microneedles. We demonstrated sensor function in buffer, blood, and porcine skin (a common proxy for human skin). In addition to the applied sensing project, we also worked to improve fundamental understanding of the aptamer sensing platform and how it responds to biomolecular interferents. Specifically, we explored the interfacial dynamics of biofouling – a process impacting sensors placed in complex fluids, such as blood.

59 BASIC BIOLOGICAL SCIENCES↗

Electrochemical approaches for chemical and biological analysis on Mars

Obtaining in situ chemical data from planetary bodies such as Mars or Europa can present significant challenges. The one analytical technique that has many of the requisite characteristics to meet such a challenge is electroanalysis. Described here are three electroanalytical devices designed for in situ geochemical and biological analysis on Mars. The Mars Environmental Compatibility Assessment (MECA) was built and flight qualified for the now cancelled NASA Mars 2001 Lander. Part of MECA consisted of four "cells" containing arrays of electrochemical based sensors for measuring the ionic species in soil samples. A next-generation MECA, the Robotic Chemical Analysis Laboratory (RCAL), uses a carousel-type system to allow for greater customization of analytical procedures. A second instrument, proposed as part of the 2007 CryoScout mission, consists of a flow-through inorganic chemical analyzer (MICA). CryoScout is a torpedo-like device designed for subsurface investigation of the stratigraphic climate record embedded in Mars' north polar cap. As the CryoScout melts its way through the ice cap, MICA will collect and analyze the meltwater for a variety of inorganics and chemical parameters. By analyzing the chemistry locked in the layers of dust, salt, and ice, geologists will be able to determine the recent history of climate, water, and atmosphere on Mars and link it to the past. Finally, electroanalysis shows its abilities in the detection of possible microorganism on Mars or elsewhere in the solar system. To identify an unknown microorganism, one that may not even use Earth-type biochemistry, requires a detection scheme which makes minimal assumptions and looks for the most general features. Recent work has demonstrated that the use of an array of electrochemical sensors which monitors the changes in a solution via electrical conductivity, pH, and ion selective electrodes, can be used to detect minute chemical perturbations caused by the growth of bacteria and with the correct methodology provide unamibiguous detection of such life forms.

Non-NASA Center↗

Miniaturized Amperometric Solid Electrolyte Carbon Dioxide Sensors

A miniaturized electrochemical carbon dioxide (CO2) sensor using Na3Z r2Si2PO12 (NASICON) as a solid electrolyte has been fabricated and de monstrated. Microfabrication techniques were used for sensor fabricat ion to yield a sensing area around 1.0 mm x 1.1 mm. The NASICON solid electrolyte and the Na2CO3/BaCO3 (1:1.7 molar ratio) auxiliary elect rolyte were deposited by sputtering in between and on top of the inte rdigitated finger-shaped platinum electrodes. This structure maximize s the length of the three-phase boundary (electrode, solid electrolyt e, and auxiliary electrolyte), which is critical for gas sensing. The robust CO2 sensor operated up to 600 C in an amperometric mode and a ttempts were made to optimize sensor operating parameters. Concentrat ions of CO2 between 0.02% and 4% were detected and the overall sensor performance was evaluated. Linear response of sensor current output to ln[CO2 concentration] ranging from 0.02% to 1% was achieved.

Hunter, G. W.↗

Root Cause Analysis of Degradation in Protonic Ceramic Electrochemical Cell with Interfacial Electrical Sensors Using Data‐Driven Machine Learning

Abstract Protonic ceramic electrochemical cells (PCECs) offer promising paths for energy storage and conversion. Despite considerable achievements made, PCECs still face challenges such as physiochemical compatibility between componenets and suboptimal solid–solid contact at the interfaces between the electrolytes and electrodes. In this study, a novel approach is proposed that combines in situ electrochemical characterization of interfacial electrical sensor embedded PCECs and machine learning to quantify the contributions of different cell components to total degradation, as well as to predict the remaining useful life. The experimental results suggest that the overpotential induced by the oxygen electrode is 48% less than that of oxygen electrode/electrolyte interfacial contact for up to 1171 h. The data‐driven machine learning simulation predicts the RUL of up to 2132 h. The root cause of degradation is overpotential increase induced by oxygen electrode, which accounts for 82.9% of total cell degradation. The success of the failure diagnostic model is demonstrated by its consistency with degradation modes that do not manifest in electrolysis fade during early real operations. This synergistic approach provides valuable insights into practical failure diagnosis of PCECs and has the potential to revolutionize their development by enabling improved performance prediction and material selection for enhanced durability and efficiency.

25 ENERGY STORAGE↗

Electrochemically Grown Single Nanowire Sensors

We report a fabrication technique that is potentially capable of producing arrays of individually addressable nanowire sensors with controlled dimensions, positions, alignments, and chemical compositions. The concept has been demonstrated with electrodeposition of palladium wires with 75 nm to 350 nm widths. We have also fabricated single and double conducting polymer nanowires (polyaniline and polypyrrole) with 100nm and 200nm widths using electrochemical direct growth. Using single Pd nanowires, we have also demonstrated hydrogen sensing. It is envisioned that these are the first steps towards nanowire sensor arrays capable of simultaneously detecting multiple chemical species.

conducting polymer nanowires↗

A portable hypergolic oxidizer vapor sensor for NASA's Space Shuttle program

The design and performance characteristics of an electrochemical NO2 sensor selected by NASA for the space shuttle program is described. The instrument consists of a sample pump, an electrochemical cell, and control and display electronics. The pump pushes the sample through the electrochemical cell where the vapors are analyzed and an output proportional to the NO2 concentration is produced. The output is displayed on a panel meter, and is also available at a recorder jack. The electrochemical cell is made up of a polypropylene chamber covered with teflon membrane faceplates. Plantinum electrodes are bonded to the faceplates, and the sensing and counter electrodes are potentiostatically controlled at -200 mV with respect to the reference electrode. The cell is filled with electrolyte, consisting of 13.5 cc of 23% solution of KOH.

Helms, W. R.↗

Microbial sensor system for monitoring the environment and surfaces

A microbial sensor, system and method that can be used to determine the biochemical conditions of waters, saturated sediments, unsaturated soils, rhizosphere and other environments is disclosed. The flexibility of the microbial sensor design allows for the monitoring of surfaces (skin, ventilation conduits, etc.). An electrochemical microbial sensor system is composed of an indicator electrode(s) and a reference electrode. The reference electrode employs a hydrogen permeable membrane. The electrochemical system is interfaced into a signal/communication module allowing the manual or automated collection of data from field deployments and laboratory investigations. The data is transmitted using various communication technologies including Bluetooth™, cellular, satellite and radio telemetry to cloud-based data management systems. The stored data may be downloaded by users using open-source dashboard and visualization software to image the various environments and/or surfaces investigated.

Burge, Scott R.↗

Direct and Sensitive Electrochemical Evaluation of Pramipexole Using Graphitic Carbon Nitride (gCN) Sensor

Pramipexole (PMXL) belongs to the benzothiazole class of aromatic compounds and is used in treating Parkinson’s disease; however, overdosage leads to some abnormal effects that could trigger severe side effects. Therefore, it demands a sensitive analytical tool for trace level detection. In this work, we successfully developed an electrochemical sensor for the trace level detection of PMXL, using the voltammetric method. For the analysis, graphitic carbon nitride (gCN) was opted and synthesized by using a high-temperature thermal condensation method. The synthesized nanoparticles were employed for surface characterization, using transmission electron microscopy (TEM), X-ray diffraction (XRD), and atomic force microscopy (AFM) techniques. The electrochemical characterization of the material was evaluated by using the electrochemical impedance spectroscopy (EIS) technique to evaluate the solution–electrode interface property. The cyclic voltammetry (CV) behavior of PMXL displayed an anodic peak in the forward scan, indicating that PMXL underwent electrooxidation, and an enhanced detection peak with lower detection potential was achieved for gCN-modified carbon paste electrode (gCN·CPE). The influence of different parameters on the electrochemical behavior was analyzed, revealing the diffusion governing the electrode process with an equal number of hydronium ions and electron involvement. For the fabricated gCN·CPE, good linearity range was noticed from 0.05 to 500 µM, and a lower detection limit (L D ) of 0.012 µM was achieved for the selected concentration range (0.5 to 30 µM). Selectivity of the electrode in PMXL detection was investigated by conducting an interference study, while the tablet sample analysis demonstrates the sensitive and real-time application of the electrode. The good recovery values for the analysis illustrate the efficiency of the electrode for PMXL analysis.

36 MATERIALS SCIENCE↗

Surface electron modulation of metal oxide‐based electrochemical devices by surface additives—linking sensors and fuel cells

Abstract The interaction between ambient oxygen and the metal oxide surface is central to various electrochemical devices. Solid oxide fuel cell cathodes and semiconducting metal oxide gas sensors are two prominent examples. Parallels between these two systems are highlighted in this perspective. In both cases, the presence of foreign surface species has been found to significantly alter the interactions of the metal oxides’ surfaces with oxygen. On the one hand, interactions are hindered due to the presence of certain impurities, such as the degradation of fuel cell cathode by Si‐species that originate from processing or from operating environments. On the other hand, electrochemically active noble metal additives have been intentionally used to tune the sensor response of metal oxides. In the case of electrochemically active additives, the need for operando spectroscopies to elucidate the mechanism is discussed. Electronic coupling of the surface additive with the metal oxide is found to play a central role in both cases. We use these results to demonstrate that insights gained from either field can be effectively applied to the other.

Materials Science↗

Multielectrode Array Sensors to Enable Long-Duration Corrosion Monitoring and Control of Concentrating Solar Power Systems

Molten mixtures of MgCl2-KCl-NaCl are promising heat transfer fluid (HTF) candidates for the next generation of concentrating solar power systems (Gen3 CSP), because of their low cost, high decomposition temperature, and favorable heat transfer characteristics. However, if the chemistry of the salts is not properly controlled, molten chlorides can cause corrosion of high-temperature metal alloys, such as Inconel (R), in CSP systems. Here we demonstrate a corrosion monitoring system that can be used to monitor the health of the structural alloys over long durations. The monitoring system includes a multielectrode array voltammetry sensor that measures the redox potential of molten MgCl2-KCl-NaCl mixture as well as the presence of corrosion products and impurities. The sensors have been successfully operated in static molten salt environments for long durations, and are capable of detecting corrosion products, such as Cr2+ and Fe2+, quantitatively at low concentrations (i.e., approximately 100 ppm) with less than 4% error.

Concentrated solar power↗

Paper-based gold nanoparticles decorated SWCNTs chemiresistive sensor for sensitive detection of As(III) based on electrochemical doping

A paper-based chemiresistive sensor consisting of a single-walled carbon nanotubes network with electrodeposited gold nanoparticles (AuNPs-SWCNTs) was developed for the sensitive detection of As(III). A new sensing strategy was also proposed combined with a paper-based device for As(III) chemiresistive detection based on the electrochemical doping of As(0) on the AuNPs-SWCNTs channel. Here, the proposed paper-based chemiresistive sensor was manufactured by wax printing and vacuum deposition using a water-based SWCNTs ink. The sensor sensitivity was enhanced by optimizing the volume of SWCNTs ink used in the formation of the sensing network in the paper and the sweep segment of cyclic voltammetry used for the electrochemical deposition of AuNPs. Additionally, the mechanism of the sensing strategy based on the electrochemical n-doping of As(0) to the AuNPs-SWCNTs sensing channel was investigated using a liquid-ion gated FET system. The As(III) concentration detected by the as-fabricated chemiresistive sensor is as low as 1.35 × 10 -5 μM which is even lower than the maximum permissible concentration in drinking water defined by the WHO. In this paper, we provide a simple strategy for developing paper-based chemiresistive sensors with unique properties for practical As(III) determination.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Highly Robust Electrical Interconnects and Ultrasensitive Biosensors Based on Embedded Carbon Nanotube Arrays

We report on our recent breakthroughs in two different applications using well-aligned carbon nanotube (CNT) arrays on Si chips, including (1) a novel processing solution for highly robust electrical interconnects in integrated circuit manufacturing, and (2) the development of ultrasensitive electrochemical DNA sensors. Both of them rely on the invention of a bottom-up fabrication scheme which includes six steps, including: (a) lithographic patterning, (b) depositing bottom conducting contacts, (c) depositing metal catalysts, (d) CNT growth by plasma enhanced chemical vapor deposition (PECVD), (e) dielectric gap-filling, and (f) chemical mechanical polishing (CMP). Such processes produce a stable planarized surface with only the open end of CNTs exposed, whch can be further processed or modified for different applications. By depositing patterned top contacts, the CNT can serve as vertical interconnects between the two conducting layers. This method is fundamentally different fiom current damascene processes and avoids problems associated with etching and filling of high aspect ratio holes at nanoscales. In addition, multiwalled CNTs (MWCNTs) are highly robust and can carry a current density of 10(exp 9) A/square centimeters without degradation. It has great potential to help extending the current Si technology. The embedded MWCNT array without the top contact layer can be also used as a nanoelectrode array in electrochemical biosensors. The cell time-constant and sensitivity can be dramatically improved. By functionalizing the tube ends with specific oligonucleotide probes, specific DNA targets can be detected with electrochemical methods down to subattomoles.

Li, Jun↗