Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrochemical sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Electropolymerized-molecularly imprinted polymers (E-MIPS) as sensing elements for the detection of dengue infection

Here, a straightforward in situ detection method for dengue infection was demonstrated through the molecular imprinting of a dengue nonstructural protein 1 (NS1) epitope into an electropolymerized molecularly imprinted polyterthiophene (E-MIP) film sensor. The key enabling step in the sensor fabrication is based on an epitope imprinting strategy, in which short peptide sequences derived from the original target molecules were employed as the main template for detection and analysis. The formation of the E-MIP sensor films was facilitated using cyclic voltammetry (CV) and monitored in situ by electrochemical quartz crystal microbalance (EC-QCM). Surface properties were analyzed using different techniques including atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and polarization modulation-infrared reflection-adsorption (PM-IRRAS). The standard calibration curve (R = 0.9830) was generated for the detection of the epitope, Ac-VHTWTEQYKFQ-NH 2 , with a linear range of 0.2 to 30 μg/mL and detection limit of 0.073 μg/mL. A separate calibration curve (R = 0.9786) was obtained using spiked buffered solutions of dengue NS1 protein, which resulted in a linear range of 0.2 to 10 μg/mL and a detection limit of 0.056 μg/mL. The fabricated E-MIP sensor exhibited long-term stability, high sensitivity, and good selectivity towards the targeted molecules. These results indicated that the formation of the exact and stable cavity imprints in terms of size, shape, and functionalities was successful. In our future work, we aim to use our E-MIP sensors for NS1 detection in real-life samples such as serum and blood.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoporous Pt(Au) Alloys for the Enhanced, Non–enzymatic Detection of Hydrogen Peroxide under Biofouling Conditions

The non-enzymatic electrochemical sensing of hydrogen peroxide (H 2 O 2 ) is described. This study utilized a 3D bicontinuous nanoporous platinum-gold alloy-based sensor (NP-Pt(Au) electrode), which has a morphology that resembles a molecular sieve. SEM and CV were used to evaluate the morphological and electrochemical characteristics of the NP-Pt(Au) electrodes. The cathodic voltammetric response of H 2 O 2 was enhanced at the NP-Pt(Au) as compared to planar Pt electrodes. Further, the nanoporous electrode was able to maintain the H 2 O 2 voltammetric profile even in the presence of the biofouling agent, serum albumin. Its application as a non-enzymatic sensor for the amperometric measurement of H 2 O 2 was explored.

36 MATERIALS SCIENCE↗

A high-temperature mixed potential CO gas sensor for in situ combustion control

An in situ, accurate and robust sensor that can sustain a high temperature of above 1000 °C is needed for on-site combustion monitoring because it can give real-time and local data to the control system to adjust the overall combustion efficiency. In this work, we find that nickel oxide (NiO) is a promising sensing material for CO which is a direct indicator of the status of the combustion process of a power plant. Under the conditions of 0.5–3% O 2 and 1000 °C, the fabricated yttrium-stabilized zirconia (YSZ)-based mixed potential sensor using porous NiO demonstrates good sensitivity to CO, showing a signal as high as 36 mV to 1000 ppm CO. The effects of gas transport, structure and geometry of the NiO electrode on the sensing performance are studied. Results show that fast gas transport is much beneficial to improved sensitivity. NiO having a porous structure is much more sensitive to CO than that having a dense structure. But the t90 (time to achieve 90% final signal magnitude) of the former is much longer due to slower gas diffusion inside the pores. It's worth noting that the NiO sensor exhibits a positive relationship with the CO content, opposite to other reported results of mixed potential sensors to detect CO. We find that this might be due to the electrochemical reduction, instead of oxidation of CO during the interaction with NiO at 1000 °C. Selectivity tests on how CO 2 , CH 4 and steam affect CO sensing are also demonstrated. NiO is insensitive to even 10% CO 2 . CH 4 does not shift the average value of the CO sensing response. However, it makes the sensing signal fluctuate more intensively. 2% steam exerts a great influence on NiO sensitivity to CO: it magnifies the sensitivity of the porous NiO electrode to a low CO range of 0–100 ppm, but inhibits its sensitivity to a CO range of 100 ppm to 1000 ppm. Lastly, an 11 day stability test demonstrates the promising stability property of the proposed NiO-based YSZ sensor.

20 FOSSIL-FUELED POWER PLANTS↗

Single-atom materials boosting wearable orthogonal uric acid detection

Abstract Uric acid (UA) is a vital biomarker for the diagnosis and management of various health conditions, including cardiovascular diseases, gout, kidney disorders, metabolic syndrome, and wound healing. Despite significant advances in wearable sensor technology, challenges persist in developing wearable sensors that are capable of maintaining high sensitivity, selectivity, and stability. In this study, we present an epidermal sensing platform enhanced with single-atom materials (SAMs) designed for flexible and orthogonal electrochemical detection of UA. We designed and synthesized an SAM with Fe-N 5 active sites to boost the electrochemical sensing signals, integrating it with laser-engraved graphene (LEG) to fabricate a wearable SAM-based UA patch sensor. This design provides superior UA detection performance compared to sensors based on conventional nanomaterials. In addition, we enhanced the detection accuracy and range by using an orthogonal approach that combines direct oxidation through differential pulse voltammetry (DPV) along with parallel biocatalytic amperometric detection. The resulting SAM-based UA orthogonal sensor patch demonstrated exceptional performance in wearable applications through tests measuring sweat UA levels in subjects before and after consuming a purine-rich diet. Graphical Abstract

Ding, Shichao↗

Lithium-Ion Battery Diagnostics Using Electrochemical Impedance via Machine-Learning

Diagnosing battery states such as health, state-of-charge, or temperature is crucial for ensuring the safety and reliability of electrochemical energy storage systems. While some states, such as temperature, may be measured using cheap sensors, accurate diagnosis of battery health metrics usually requires time-consuming performance measurements, making them infeasible for use in real-world operation. These health metrics can be measured during lab-testing and then estimated on-line using predictive life models or via state observer algorithms such as Kalman filters, but these predictive methods should be supplemented by actual measurement of battery health whenever possible to ensure reliability. Rapid measurement of battery health may be done by various types of fast diagnostic techniques such as electrochemical impedance spectroscopy (EIS), which can be performed in only a few minutes and require only a fraction of the energy and power needed for a full charge and discharge measurement. But there is a substantial challenge for estimating battery health using EIS data, as EIS is sensitive to cell temperature, state-of-charge, current, and resting time in addition to health. Thus, utilizing EIS data to predict battery capacity requires correcting for all these additional variables, a task that is extremely difficult to handle analytically. This talk utilizes machine-learning methods to estimate the effectiveness of battery capacity prediction from EIS data, leveraging a data set of hundreds of EIS measurements recorded at varying temperature and state-of-charge throughout a 500-day aging study of 32 commercial, large-format NMC-Graphite lithium-ion batteries. Using EIS as input to machine-learning models is complicated by the nonlinear response of impedance to battery health, temperature, and state-of-charge, as well as the collinearity between the impedance response at neighboring frequencies, which can easily lead to overfit models. To train robust models, features from EIS data need to be extracted from the data or some subset of critical frequencies selected. Many approaches for extracting and selecting features from EIS data from electrochemical analysis and machine-learning fields were identified for analysis: using the entire raw spectra; selection of one, two, or many frequencies from the entire spectra; selecting interesting points from the EIS measurement using domain knowledge; fitting EIS with an equivalent-circuit model; calculating statistics on the raw impedance values; and reducing the dimensionality of the data using unsupervised linear (principal component analysis) and non-linear (uniform manifold approximation and projection) methods. These approaches were rigorously compared using a machine-learning pipeline approach, training linear, Gaussian process, and random forest regression models and quantifying performance using cross-validation as well as a held-out test set. An artificial neural network model trained on the raw spectra was also tested. Promising pipelines were fine-tuned via Bayesian hyperparameter optimization using cross-validation loss and training with class-specific weights to counter data set imbalance. The most reliable method for utilizing impedance in this work was the selection of two optimal frequencies through an exhaustive search, resulting in about 2% mean absolute error on test data for both Gaussian process and random forest model architectures. Interrogation of a variety of models reveals critical frequencies of 100 Hz and 103 Hz for this data set, though the optimal set of frequencies is not necessarily intuitive, i.e., the best performing models are not simply those that use impedance at frequencies that have the highest correlation to the relative discharge capacity. The best performing model is an ensemble model, which is able to predict battery capacity with 1.9% mean absolute error for unseen cells using impedance recorded at a variety of temperatures and states-of-charge.

battery↗

Enhancement‐Mode PEDOT:PSS Organic Electrochemical Transistors Using Molecular De‐Doping

Abstract Organic electrochemical transistors (OECTs) show great promise for flexible, low‐cost, and low‐voltage sensors for aqueous solutions. The majority of OECT devices are made using the polymer blend poly(ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS), in which PEDOT is intrinsically doped due to inclusion of PSS. Because of this intrinsic doping, PEDOT:PSS OECTs generally operate in depletion mode, which results in a higher power consumption and limits stability. Here, a straightforward method to de‐dope PEDOT:PSS using commercially available amine‐based molecular de‐dopants to achieve stable enhancement‐mode OECTs is presented. The enhancement‐mode OECTs show mobilities near that of pristine PEDOT:PSS (≈2 cm 2 V −1 s −1 ) with stable operation over 1000 on/off cycles. The electron and proton exchange among PEDOT, PSS, and the molecular de‐dopants are characterized to reveal the underlying chemical mechanism of the threshold voltage shift to negative voltages. Finally, the effect of the de‐doping on the microstructure of the spin‐cast PEDOT:PSS films is investigated.

Keene, Scott T.↗

Microfluidic cells for the 1–10 2 MPa pressure range

Thin membrane-delimited fluid cells supporting up to 1 at (0.1 MPa) of pressure are well known and commercially available for use in vacuum chambers of electron, photon, or various particle beam microscopies or spectroscopies. Hereby, we report on the development of fluid cells capable of working at 1–10 MPa, extending the analysis domain for investigating chemical, biochemical, or physical processes at pressures of interest in chemical synthesis, underwater biochemistry studies or underground geology. We explored ways to optimize cell membranes to better resist pressure beyond simply increasing the thickness or decreasing the size of the membranes, using finite element analysis and experimental validation via membrane bulging experiments and failure statistics. Fluid cell prototypes were fabricated using ∼75 nm-thick SiN x membranes, engineered to withstand 4.7 MPa (average value), compared to regular (un-engineered) membranes withstanding only 3.4 MPa (average value). The fluid cell prototypes include eight microchannels for feeding/evacuating the fluids and applying pressure into micro-reaction chambers, two electrodes for electrochemical or conduction measurements in the sample, and a possible pressure or temperature sensor, customizable for specific experiments.

hi-pressure↗

Secondary battery management system

A method and system for managing a battery system. The method including receiving at least one measured characteristic of the battery over a pre-defined time horizon from the at least one sensor, receiving at least one estimated characteristic of the battery from a electrochemical-based battery model based on differential algebraic equations, determining a cost function of a Moving Horizon Estimation based on the at least one measured characteristic and the at least one estimated characteristic, updating the electrochemical-based battery model based on the cost function, estimating at least one state of the at least one battery cell by applying the electrochemical-based battery model, and regulating at least one of charging or discharging of the battery based on the estimation of the at least one state of the at least one battery cell.

MirTabatabaei, Anahita↗

Transformation of TiN to TiNO Films via In-Situ Temperature-Dependent Oxygen Diffusion Process and Their Electrochemical Behavior

Titanium oxynitride (TiNO) thin films represent a multifaceted material system applicable in diverse fields, including energy storage, solar cells, sensors, protective coatings, and electrocatalysis. This study reports the synthesis of TiNO thin films grown at different substrate temperatures using pulsed laser deposition. A comprehensive structural investigation was conducted by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), Non-Rutherford backscattering spectrometry (N-RBS), and X-ray absorption spectroscopy (XAS), which facilitated a detailed analysis that determined the phase, composition, and crystallinity of the films. Structural control was achieved via temperature-dependent oxygen in-diffusion, nitrogen out-diffusion, and the nucleation growth process related to adatom mobility. The XPS analysis indicates that the TiNO films consist of heterogeneous mixtures of TiN, TiNO, and TiO2 phases with temperature-dependent relative abundances. The correlation between the structure and electrochemical behavior of the thin films was examined. The TiNO films with relatively higher N/O ratio, meaning less oxidized, were more electrochemically active than the films with lower N/O ratio, i.e., more oxidized films. Films with higher oxidation levels demonstrated enhanced crystallinity and greater stability under electrochemical polarization. These findings demonstrate the importance of substrate temperature control in tailoring the properties of TiNO film, which is a fundamental part of designing and optimizing an efficient electrode material.

Cherono, Sheilah↗

A machine learning degradation model for electrochemical capacitors operated at high temperature

Electrochemical capacitors (ECs) have only recently been considered as an alternative power source for telemetry sensors of drilling equipment for geothermal or oil and gas exploration. The lifecycle analysis and modelling of ECs is underrepresented in literature in comparison to other storage devices e.g. Li-ion batteries. This paper investigates the degradation of ECs when cycled outside the manufacturer-specified operating temperature envelope and proposes a machine learning-based approach for modelling the degradation. Experimental results show that end of life, defined as a 30% decrease in capacitance, occurs at 1,000 cycles when the environmental temperature exceeds the maximum operating temperature by 30%. The life-cycle test data is then used as an input to a Gaussian process regression (GPR) algorithm to predict the capacitance fade trend. The GPR is validated on a total of nine commercial cells from two different manufacturers, achieving an average root mean squared percent error of less than 2% and a mean calibration score of 93% when referenced to a 95% confidence interval. The model can be utilized to determine the EC degradation rate at a range of operating temperature values.

42 ENGINEERING↗

Electrochemical Synthesis of Zeolite Coatings with Controlled Crystal Polymorphism and Self-Regulating Growth

Zeolite coatings are studied as molecular sieves for membrane separation, membrane reactors, and chemical sensor applications. They are also studied as anticorrosive films for metals and alloys, antimicrobial and hydrophobic films for heating, ventilation, and air conditioning, and dielectrics for semiconductor applications. Zeolite coatings are synthesized by hydrothermal, ionothermal, and dry-gel conversion approaches, which require high process temperatures and lengthy times (ranging from hours to days). Here, we report the first zeolite coatings synthesized via electrochemical deposition on a cathodic electrode, with controlled crystal polymorphism achieved within subhourly duration. We demonstrate this approach by developing sodium zeolite (e.g., sodalite (SOD), NaA (LTA), and Linde Type N (LTN)) coatings on a titanium electrode and extending the synthesis method to porous stainless steel. The coating morphology and crystallinity depend on the temperature, time, and applied current. The coating thickness is independent of the applied current, showing the presence of a self-regulating mechanism to ensure a uniform coating thickness across the metal surface. The electrochemical zeolite growth mechanism was elucidated with high-resolution transmission electron microscopy, and applications of the resultant zeolite coatings for oil/water separation and ethanol/water pervaporation were exploited. Electrochemical synthesis represents a novel, simple, fast, and environmentally friendly approach to preparing zeolite coatings. It can potentially be generalized for developing zeolite materials with diverse framework structures, morphologies, and orientations for substrates with complicated geometries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Connection between the physicochemical characteristics of amorphous carbon thin films and their electrochemical properties

Connecting a material's surface chemistry with its electrocatalytic performance is one of the major questions in analytical electrochemistry. This is especially important in many sensor applications where analytes from complex media need to be measured. Unfortunately, today this connection is still largely missing except perhaps for the most simple ideal model systems. Here we present an approach that can be used to obtain insights about this missing connection and apply it to the case of carbon nanomaterials. In this paper we show that by combining advanced computational techniques augmented by machine learning methods with x-ray absorption spectroscopy (XAS) and electrochemical measurements, it is possible to obtain a deeper understanding of the correlation between local surface chemistry and electrochemical performance. As a test case we show how by computationally assessing the growth of amorphous carbon (a-C) thin films at the atomic level, we can create computational structural motifs that may in turn be used to deconvolute the XAS data from the real samples resulting in local chemical information. Then, by carrying out electrochemical measurements on the same samples from which x-ray spectra were measured and that were further characterized computationally, it is possible to gain insight into the interplay between the local surface chemistry and electrochemical performance. To demonstrate this methodology, we proceed as follows: after assessing the basic electrochemical properties of a-C films, we investigate the effect of short HNO 3 treatment on the sensitivity of these electrodes towards an inner sphere redox probe dopamine to gain knowledge about the influence of altered surface chemistry to observed electrochemical performance. Overall, these results pave the way towards a more general assessment of electrocatalysis in different systems and provide the first steps towards data driven tailoring of electrode surfaces to gain optimal performance in a given application.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Predicting battery capacity from impedance at varying temperature and state of charge using machine learning

Prediction of battery health from electrochemical impedance spectroscopy (EIS) data can enable rapid measurement of battery state in real-world applications without using additional sensors or time-consuming performance measurements. However, deconvoluting the effect of capacity, state of charge, and temperature on EIS response is complicated analytically. Here, various machine-learning models, such as linear, Gaussian process, random forest, and artificial neural network regression, are utilized to predict capacity from EIS using hundreds of capacity, direct current (DC) resistance, and EIS measurements recorded under varying conditions of health, temperature, and state of charge (SOC). Several feature extraction and selection methods from traditional electrochemical analysis and statistical modeling are explored using machine-learning pipelines. EIS data from just two frequencies can accurately predict capacity, and interrogation shows that the optimal set of frequencies is not usually intuitive. Best results are achieved with an ensemble model, which predicts battery capacity with a mean absolute error of 1.9% on data from unobserved cells.

25 ENERGY STORAGE↗

Field deployable trace radioisotope analysis through combined electrochemical and alpha spectroscopy methods

A method for depositing actinides directly onto a 4H-SiC Schottky barrier diode (SBD) detector as a field deployable actinides sensor was developed to enable off-site analysis, shortening the time to obtain critical information such as elements, concentration, and/or isotopic ratio related to the radiological situation. A thin film of Hg was first electrodeposited onto the Pt contact of the SiC diode, followed by chronoamperometric deposition of microgram levels of actinides under conventional control conditions. The 4H-SiC diode maintained consistent functionality through the electrodeposition process and showed resolved alpha-energy spectra that contained accurate isotopic information demonstrating the feasibility of a combined chemical and radiological sensor for field actinide detection and quantification.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Deployment of Advanced Electroanalytical Sensors in the Kairos Power Engineering Test Unit (ETU) (Final CRADA Report)

This document serves as a summary report for the work conducted under CRADA 2022-22119 between Argonne National Laboratory and Kairos Power LLC. As part of this project, Argonne and Kairos worked to develop an advanced electrochemical system and testing protocol for the Kairos Power Enineering Test Unit (ETU), an industrial scale 14 ton molten FLiBe salt system. The main goals were (1) measurements of fundamental properties for key salt species, (2) the deployment and operations of sensors in the ETU, and (3) the development of automated approaches to analyze the measurements.

42 ENGINEERING↗

Super-porous Pt/CuO/Pt hybrid platform for ultra-sensitive and selective H 2 O 2 detection

A super-porous Pt/CuO/Pt hybrid electrode is demonstrated with extremely high sensing performance parameters for the hydrogen peroxide (H 2 O 2 ) detection. A unique physiochemical approach is adapted for the fabrication of 3-D super-porous Pt/CuO/Pt sensing platform. Here, the super-porous Pt/CuO/Pt hybrid platform demonstrates a superior sensitivity of 16,694 µA mM -1 cm -2 with a limit of detection of 2.91 nM (S/N = 3). It also demonstrates an excellent selectivity against the interfering molecules such as NaCl, fructose, ascorbic acid, citric acid, dopamine and glucose with a wide linear range. The demonstrated performance ranks the Pt/CuO/Pt hybrid platform as one of the best H 2 O 2 sensors as summarized in the Table 2. The super-porous CuO layer is fabricated by a dynamic hydrogen bubbling technique of electrochemical deposition and metallic Pt NP decoration is achieved by the physical vapor deposition (PVD) and post-annealing. The super-porous CuO layer offers a drastically improved electrochemical active surface area, and the Pt NP decoration offers a significantly improved conductivity and improved charge accumulation for the H 2 O 2 reduction. The DFT simulations confirm the predominance of CuO over Cu 2 O and Pt over Pd for the H 2 O 2 detection based on the adsorption energy, density of states and charge accumulation calculations.

36 MATERIALS SCIENCE↗