Search NASA⌕ Search

SEARCH · Search NASA

Results for “electromagnetic coils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Enhancement of EM Pump Performance through Modeling and Testing

Liquid sodium has seen development as a nuclear reactor coolant in the United States for over 50 years. While sodium has many desirable characteristics as a heat transfer fluid, its reactivity poses numerous engineering challenges for even the most basic plant components like pumps. Despite the challenges, mechanical pumps have seen success in sodium service albeit at the expense of simplicity and flexibility. In fact, significant failures of these pumps have been recorded which can be attributed to their complexity. Notwithstanding the complexity, mechanical pumps are still widely proposed for the main circuit pump of sodium cooled reactors. However, an alternative to mechanical pumps are Electromagnetic Induction Pumps (EMIPs) which use the principle of the Lorentz Force. EMIPs avoid mechanically moving parts in contact with sodium which simplifies the design by avoiding mechanical wear and seals. Therefore, these pumps are generally safer and more reliable than their mechanical counterparts. That being said, EMIPs suffer from relatively low efficiencies that range from 5% to 45%. Some of the inefficiencies are inherent to the EMIPs pumps; namely, inefficiencies arise in the form of resistive heating losses in the fluid itself. However, other inefficiencies arise from Edge Effects which include Finite Length and Finite Width effects. Due to the significant safety advantages EMIPs have compared to mechanical pumps, there is a strong motivation to integrate these technologies into the design of Generation IV liquid-metal-cooled nuclear power plants. However, EMIPs have low efficiencies partly attributed to Edge Effects. Much of the literature focusing on Edge Effects is dated or simply does not exist in the public domain. More recently, numerical models of EMIPs have shown promising results. However, these models are often custom solvers or use complex software suits which limit their application. This report describes the work completed to understand Edge Effects in two EMIPs designs. These designs are the Annular Linear Induction Pump (ALIP) and Permanent Magnet Induction Pump (PMIP) also known as a Moving Magnet Pump (MMP). The methodology developed during this project aim at measuring key performance parameters (pressure-flowrate and efficiency-slip performance) using high temperature liquid-sodium. Baseline experimental measurements were then used to verify the accuracy of numerical models developed in the software suit ANSYS/FLUENT. On the experimental side, instrumentation was developed to characterize the pressure-flowrate and efficiency-slip performance of both the ALIP and PMIP in high-temperature liquid-sodium. Additionally, instrumentation was developed to measure potential output pressure pulsations and the magnetic field distributions. Moreover, a specialized ALIP was constructed to study the impacts magnetic field tapering, also known as coil grading, on the Finite Length Effect. Lastly, experimental performance curves of the PMIP were collected at 300 oC and 600 oC and compared to analytical theory which accounted for Finite Width Effects. These results showed that the Finite Width Effect and non-uniform magnetic field in a PMIP impact the performance. On the numerical side, models were developed using the software suit FLUENT/ANSYS. These methods were initially compared against a simple MHD flow in a Permanent Magnet Electromagnet Flowmeter (PMEMFM). The results were significant in that they showed agreeance between the numerical model and demonstrated that PMEMFM’s could be calibrated numerically. These modeling methods were then applied to a prototypic PMIP. Results showed that this simple model provided reasonably accurate results of the PMIP p-Q performance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Absolute magneto-optical measurement of magnetic field on a long pulse high electrical current driven solenoid

We describe a direct absolute magneto-optical approach to measuring the magnetic field driven by long pulse width (>5 ms) and high electrical current (∼kA) in a solenoidal coil. The magnetic field and electrical current are among the most important operating parameters in lightning research and electrical power distribution and are essential to understanding the properties of the radiation output in pulsed energy accelerators as well as other research platforms. However, accurately measuring these magnetic fields and electrical currents using conventional electrical diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element material sensing crystal that is highly resistant to electromagnetic interference, allows for absolute measurement, and does not require an external calibration. Here, we focus on device theory, operating parameters, magneto-optical results from an experiment on a high current solenoid, and comparison with a calculation of the magnetic field and reference electrical current flowing downstream of the solenoid.

Owens, Israel [Sandia National Laboratories (SNL-N↗

Concept Study of Robotic Camera-Based Foreign Object Detection for EV Wireless Charging

Wireless charging of an electric vehicle (EV) is an emerging charging technology promising convenient, autonomous, and highly efficient EV charging without requiring heavy gauge cables. However, due to the strong electromagnetic field created by this process that surrounds the wireless charger, the presence of foreign objects can detrimentally interact with it, thus affecting wireless power transfer (WPT) performance or leading to harmful and unwanted safety risks. This paper presents the results for a concept study on a robotic camera-based foreign object detection (FOD) system, as a supplement to the industry-existing overlapped FOD coil array method, for EV wireless charging. A Raspberry PI 4 control board and compatible Raspberry PI Camera Module 2 are used to implement camera-based object detection. The FOD program was developed using a state-of-the-art deep learning object detection model with the OpenCV and Pytorch library and is compatible with camera module hardware. A dry-run test with Raspberry PI and a camera module was conducted and the preliminary FOD function was verified. The feasibility assessment is also validated by comparing the performance of five existing state-of-the-art deep learning object detection models for vehicles, animals, persons, and metals subsets, respectively. Satisfactory performance on the benchmark datasets is observed by the tests, but further improvements are needed in future work when detecting small-sized metallic objects. A programable robotic car is also under development as ongoing work for carrying the Raspberry PI and camera module while moving for the maintenance process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Efficient Silicon Carbide (SiC) Fiber Manufacture: Continuous Processing of Novel Precursors via Modified Material Handling

General Atomics Electromagnetic Systems (GA-EMS) together with The Nonwovens Institute (NWI) and Harper International have executed on a development project to improve the production efficiency and reduce the production cost of silicon carbide (SiC) fiber – a critical material that advances US energy security and aerospace leadership. In the first budget period (BP1), the modified tow throughput (MTT) apparatus was developed, enabling fiber spinning in the form of loose coils rather than tightly packed spools (Figure 1) for batch processing of SiC fiber. This coil-based approach was proven to be capable of uniform fiber crosslinking and ceramic conversion, as well as demonstrating key process efficiencies while meeting the program fiber property targets.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Positron orbit effects during injection and confinement in a magnetic dipole trap

Lossless injection of positrons into a magnetic dipole trap and their subsequent confinement have been demonstrated. Here, we investigate by numerical single-particle simulations how the radial distribution of positrons in the trap is affected by the measurement itself, the choice of injection parameters, the asymmetry of the electric potential, and by elastic collisions. The results are compared to experimental data. A comprehensive understanding of these effects is a milestone on the road to creating an electron–positron plasma in a trap with a levitating superconducting coil.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design Optimization and Measurement Uncertainty of an Electromagnetic Level Sensor for Liquid Metal Reactors

Here, this article describes the design and operation of a prototype mutual inductance level sensor (MILS) and the development and validation of a finite-element analysis (FEA) model describing its behavior. The MILS was designed for use in liquid sodium up to temperatures of 650 °C in the Mechanisms Engineering Test Loop (METL) at Argonne National Laboratory (ANL). Preliminary testing was performed in a room temperature test stand with aluminum acting as an analog for the sodium to better understand sensor performance and provide accurate code validation data. This experimental data, along with material properties found in literature, were used to validate an FEA model in ANSYS Maxwell. The validated ANSYS Maxwell model was used to examine the performance of the MILS in various environments and under various operating conditions. Simulations suggest the following: The MILS will perform adequately in liquid sodium and liquid lead at temperatures up to 650 °C . The temperature dependence of electrical conductivity imposes a temperature dependence on the sensor that requires proper compensation. The MILS signal sensitivity is maximized when mutual inductance between sensor coils is maximized, and sensor geometry should be selected to account for this factor. The operating frequency of the MILS can be optimized and is dependent on process fluid material, operating temperature, and materials/geometry of sensor system. Finally, the use of a stainless-steel isolating thimble does not adversely affect the sensor signal. The primary sources of error for this MILS system are the accuracy of the calibration standard against which the sensor is calibrated, and the temperature dependence of the sensor. This work contains all the necessary details to recreate the FEA model and results. This model can be used to optimize the performance of a MILS in any operating environment to read any electrically conductive working fluid.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Computation of the Biot–Savart line integral with higher-order convergence using straight segments

One common approach to computing the magnetic field produced by a filamentary current-carrying coil is to approximate the coil as a series of straight segments. The Biot–Savart field from each straight segment is analytically known. However, if the endpoints of the straight segments are chosen to lie on the coil, then the accuracy of the Biot–Savart computation is generally only the second order in the number of endpoints. In this work, we propose a simple modification: shift each end point of the coil in the outward normal direction by an amount proportional to the local curvature. With this modification, the Biot–Savart accuracy increases to the fourth order and the numerical error is dramatically reduced for a given number of discretization points.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Shield Design for the Double-D Coil-Based Wireless Charging System

In this work, magnetic field emission (MFE) of the high-power double-D (DD) coil-based wireless charging system is investigated and a shielding technique is proposed. The MFE pattern produced by the DD coils is significantly different from the MFE of the unipolar (e.g., circular, square, or rectangular) coils, and the traditional aluminum shield does not suppress the MFE from the DD coils. This study shows that a conventional aluminum shield increases the MFE, and a magnetic shield effectively suppresses the MFE of the DD coils. Therefore, a magnetic shield consisting of high-permeability magnetic material, such as ferrites, nanocrystalline, etc., is proposed for the DD pads. The shielding effectiveness of the proposed shield is evaluated through finite element analysis and verified through experiments. An 11 kW DD coil-based wireless charging system was used to test the proposed shielding technique. The experimental results show that a traditional aluminum shield increased the MFE by 29.8%, and the proposed magnetic shield suppressed the MFE by 50.5%.

42 ENGINEERING↗

Fully Distributed Multi-Material Magnetic Sensing Structures for Multiparameter DAS Applications

This dissertation demonstrates the first of its kind distributed magnetic field sensor based on a fiber optic distributed acoustic sensing (DAS) scheme. Ferromagnetic nickel and Metglas® were dispersed internally within a fiber optic preform and then drawn on an in-house fiber optic draw tower to lengths in the kilometers. Due to the close proximity of the ferromagnetic metals and fiber optic core, the magnetostrictive strain response of the ferromagnetic materials when exposed to a magnetic field would perturbate within the fiber cladding and transfer that strain, internally, to the fiber optic core. Strain resulting from the magnetostrictive effect allows the DAS based sensor to accurately translate strain into readable magnetic field data. Due to the high sensitivity seen in this sensor design, multiparameter sources, acoustic and magnetic fields, were tested and validated and a three dimensional magnetic-field vector sensor was proposed. Numerical analysis of the novel sensor design was first implemented using COMSOL Multiphysics, where inputs such as magnetostrictive element shape, size, distance, and number were first investigated. Upon optimizing system constraints, the sensor design was further modified such that single mode operation was consistent across multiple fiber draws while retaining high strain transfer from the ferromagnetic elements to the fiber optic core. Ferromagnetic material selection was evaluated as a function of the saturation magnetostriction constants and a total of 4 modules were used to fully characterize the complex physics involved in this sensor design. All fabrication and testing were performed in-house using a full scale 3-story fiber draw tower and custom environmental testing stations to imitate naturally occurring events such as magnetic or acoustic point sources. A unique stacking method was used to embed ferromagnetic nickel and Metglas® into a fiber optic preform which when combined with a custom fiber draw process resulted in consistent multi-material fibers drawn to lengths of 1-km. In-house testing facilities included different types of electromagnetic generators, in addition to a soil test bed, and an outdoor test bed which allowed 100 meters of fiber to be tested simultaneously. All tested sensors demonstrated high strain transfer capabilities on the order of 0.01-10 μϵ depending on the materials used, ferromagnetic rod number, and core to metal spacing. Due to the sensitivity of the system the difference between AC and DC was distinct, and directional magnetostriction was studied. Transverse and longitudinal magnetic wave propagation was controlled through a solenoid and rectangular Helmholtz coil, both built in-house. A three-dimensional magnetic field vector sensor was proposed due to the success of the magnetic field sensor, and a design was proposed and initially tested to validate direction as a function of field strength and distance. To summarize, this dissertation explores the first fully distributed magnetic field sensor using DAS based techniques and one of the first multi-material fiber draw processes which can produce consistent single mode fiber up to 1-km. Due to extensive FEA modeling, multiple iterations of the magnetic sensor were fully characterized and an equation describing the relationship between sensor design and strain transfer has been created and validated experimentally. Multi-parameter tests including acoustic and magnetic fields were implemented and an algorithm was developed to separate the mixed signals. Finally, a test was performed to demonstrate the feasibility of sensing magnetic fields directionally. Cumulative results demonstrate a high-quality sensor alternative to current designs which may surpass other magnetic sensors due to innate multi-parameter capabilities, in addition to the inexpensive production cost and extremely long operating lengths.

02 PETROLEUM↗

Preliminary Design of Ironless Linear Induction Motors for ITER MSE Shutter Actuators

In this article, the shutters need to be closed or opened during the operation and calibration period time for the fusion diagnostic systems, such as the International Thermonuclear Experimental Reactor (ITER) motional stark effect (MSE). Standard electric motors and actuators will not work in a strong magnetic field environment due to the presence of the magnetic field of fusion reactors. The innovative linear induction motor (LIM) with an ironless feature overcomes this kind of challenge and can be used for any application that requires controlled motion with a large stroke in the magnetic field environment. It consists of a high-electrical conductivity plate like copper and three-phase motor windings with nonferrous or stainless-steel stators. The conductor plate attached with the shutter is simply driven by the underneath three-phase linear windings to achieve linear motion. The motor drive can be controlled remotely by a controller using the electrical connection, so no sensitive electronic components are located in the harsh environment where the motor itself is located. The design requirements and test facility have been described. Several 3-D transient Maxwell electromagnetic (EM) models with different locations of three-phase linear motor windings and shutter stators have been analyzed and evolved to meet any applications allowed in the harsh environment inside the vacuum vessel of fusion reactors. The preliminary design results are presented in this article.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of passive and structural conductors for tokamaks using thin-wall eddy current modeling

Abstract A new three-dimensional electromagnetic modeling tool ( ThinCurr ) has been developed using the existing PSI-Tet finite-element code in support of conducting structure design work for both the SPARC and DIII-D tokamaks. Within this framework a 3D conducting structure model was created for both the SPARC and DIII-D tokamaks in the thin-wall limit. This model includes accurate details of the vacuum vessel and other conducting structural elements with realistic material resistivities. This model was leveraged to support the design of a passive runaway electron mitigation coil (REMC), studying the effect of various design parameters, including coil resistivity, current quench duration, and plasma vertical position, on the effectiveness of the coil. The REMC is a non-axisymmetric coil designed to passively drive large non-axisymmetric fields during the plasma disruption thereby destroying flux surfaces and deconfining RE seed populations. These studies indicate that current designs should apply substantial 3D fields at the plasma surface during future plasma current disruptions as well as highlight the importance of having the REMC conductors away from the machine midplane in order to ensure they are robust to off-normal disruption scenarios.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel and Rugged Electromagnetic Wireless System for Long-Term Subsurface CO₂ Plume Monitoring and Saturation Mapping

Novel and rugged electromagnetic wireless system for long-term subsurface CO₂ plume monitoring and saturation mapping is a Phase I SBIR project led by Cyentech Consulting LLC to develop a permanently installed, outside-casing electromagnetic monitoring system for long-term carbon storage monitoring. The project addresses a major challenge in carbon capture and storage: the need for reliable, cable-free downhole monitoring that can detect CO₂ plume movement and saturation changes without compromising well integrity through casing perforations or external umbilical cables.

58 GEOSCIENCES↗

The Sensitivity Analysis of Coil Misalignment for a 200-kW Dynamic Wireless Power Transfer System with an LCC-S and LCC-P Compensation

The dynamic wireless power transfer systems may reduce the battery size of electric vehicles while maintaining the travel range. Similar to the stationary wireless power transfer systems, the compensation networks are desired in dynamic wireless charging systems at the primary and secondary sides to reduce the reactive power requirement from the source and improve the efficiency. Consequently, it is essential to understand the behavior of the compensation networks, especially the sensitivity to misalignments. This paper presents a sensitivity analysis of LCC-S and LCC-P compensation networks for a 200-kW power transfer with variations in the coupling coefficient due to the electric vehicle travel and misalignments between the pads. The sensitivity study combines the electromagnetic finite element analysis and circuit analysis to determine the impact of misalignments on the wireless power transfer system characteristics. The theoretical analysis is verified by conducting circuit simulations at discrete points to verify the accuracy of the mathematical model.

Kavimandan, Utkarsh↗

Electromagnetic Shielding Design for 200 kW Stationary Wireless Charging of Light-Duty EV

Wireless power transfer (WPT) is a developing technology with the advantage of convenience and flexible charging. SAE recommended practice J2954 defines typical size and geometry with aluminum or ferrite plate shielding to limit leakage electromagnetic (EM) fields for WPT with power levels lower than 22 kVA from the input side. However, as the WPT power goes up to 100- or 200-kW level, EM safety surrounding the WPT becomes a critical concern. To address this oncoming safety challenge, a novel ferrite shielding design is proposed in this paper. Different misalignment scenarios in accordance with definitions in SAE J2954 are also taken into consideration to ensure EM safety under various operation scenarios. Simulation results, which are preliminarily verified by magnetic field measurements at 1.1 m from the center of the vehicle side coil under 100 kW operation, indicate that the magnetic field leakage can be maintained below the limits defined in SAE J2954 for 200 kW operation. A 3.3 kW scale-down test was also carried out and compared to parallel scale-down simulations. 26.8% field emission reduction is observed from the scale-down test, which supports the effectiveness of the proposed shielding design.

Zhang, Bo↗

In-Field Testing of Components for Feedback and Control of the ITER Disruption Mitigation System

Here, the shattered pellet injection (SPI) method has been chosen as the disruption mitigation system (DMS) for ITER. To protect the device from plasma disruptions that cause damaging heat and electromagnetic loads, SPI is used to inject high-Z material into the plasma. The process of SPI utilizes cryogenic cooling to form solid pellets. Pellets are accelerated down a barrel and into an angled surface, causing the pellet to shatter prior to entering the tokamak chamber. For the DMS to function reliably, the 27 separate shattered pellet injectors planned for ITER must rely on many components to provide accurate feedback data and for control functions. Each component in the DMS is exposed to an elevated background magnetic field depending on its placement and proximity to the plasma chamber. A Helmholtz coil test stand that is operated at Oak Ridge National Laboratory was utilized to test the components in relevant background field levels to assess component performance. This paper details the test design and results for in-field component operation for a variety of components. This list includes the following components: two different network switches for camera connectivity, a VAT fast shutter valve intended to reduce the flow of SPI propellant gas into the torus, a solenoid control valve intended for use in the pellet formation process, pressure/vacuum switches to be used for feedback and control, a printed circuit board piezo pressure sensor to be used to measure breech pressure, and various relays for the high-voltage pulsed power supply used to drive the SPI propellant valve.

Disruption mitigation↗

Diagnosing magnetic fields in cylindrical implosions with oblique proton radiography

Two experiments at the OMEGA Laser System used oblique proton radiography to measure magnetic fields in cylindrical implosions with and without an applied axial magnetic field. Although the goal of both experiments was to measure the magnitude of the compressed axial magnetic field in the core of the implosion, this field was obfuscated by two features in the coronal plasma produced by the compression beams: an azimuthal self-generated magnetic field and small length scale, high-amplitude structures attributed to collisionless effects. In order to understand these features, synthetic radiographs are generated using fields produced by 3D HYDRA simulations. These synthetic radiographs reproduce the features of the experimental radiographs with the exception of the small-scale structures. A direct inversion algorithm is successfully applied to a synthetic radiograph but is only partially able to invert the experimental radiographs in part because some protons are blocked by the field coils. The origins of the radiograph features and their dependence on various experimental parameters are explored. Furthermore, the results of this analysis should inform future measurements of compressed axial magnetic fields in cylindrical implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Contoured PPM-EMAT Design for Ultrasonic Communication On Metallic Pipe Channels

Ultrasonic guided waves can be used as the carriers of information in ultrasonic communication for pipe or plate channels. Permanent Periodic Magnet (PPM) Electromagnetic Acoustic Transducer (EMAT) can potentially provide unique capabilities for a communication system as a non-contact transmitter and receiver, which can selectively generate different modes of shear-horizontal (SH) waves. The SH wave shows the potentials in achieving high bitrate without error in ultrasonic communication. However, when a steel pipe is used as the communication channel, especially one with a radius comparable to the size of the transducer, no guided wave signal can be excited or detected by existing PPM-EMAT's with flat coupling surface. In this paper, a 3D printed magnet holder is designed which can shape the magnet array. Also, the transmitter/receiver coils are made of flexible printed circuit which can fit over the curvature of the pipe channels. The contoured PPM-EMAT transmitter and receiver can conform to the surface of the steel pipe channel in order to generate and detect torsional waves. Experimental tests of signal transmission with PPM-EMAT on a 160cm-long stainless steel pipe determine the optimal frequency for communication to be 916KHz. Information transmission experimental results confirm the validity of contoured PPM-EMAT for communication with a bitrate of 5kbps.

Huang, Xin↗

Design and Analysis of a Mutual Inductance Level Sensor for Liquid Metals

Here, this article describes the design and analysis of an electromagnetic level sensor for use in high-temperature liquid metal systems. The mutual inductance level sensor (MILS) described in this work was fabricated using two single-conductor mineral insulated cables wrapped in a bifilar fashion around a stainless steel tube core and was housed in an isolating thimble that preserved the pressure boundary of the test vessel. Two sensor variations were fabricated that differ only in active length, 1016 and 1778 mm. Experimental data were collected using the 1016-mm sensor (MILS-MKII-040) that demonstrated a sensitivity of 9.2 μ V/mm in a room temperature testing stand that used solid aluminum as a surrogate for liquid metal. Experimental data were collected using the 1778-mm sensor (MILS-MKII-070) that demonstrated a sensitivity of 6.9 μ V/mm in the high-temperature (300 ° C) liquid sodium environment at the mechanisms engineering test loop (METL) of Argonne National Laboratory. The sensor performance was found to be repeatable over the course of several months, with roughly ±1% deviation from nominal output. Finite element models were developed in COMSOL Multiphysics that fully describe each test setup, and the models were validated using experimental data. The validated COMSOL models were used to perform an array of analyses that examined the performance of the sensor in differing environments. Maximizing the coil diameter inside the isolating thimble was found to maximize the signal and sensitivity of the sensor. An optimal operating frequency was found near 1000 Hz using both experimental data and COMSOL. The influence of a metallic thimble surrounding the sensor and a metallic sensor core was quantified and found to be negligible at the optimal operating frequency. The sensitivity of the sensor was quantified when monitoring the level of additional liquid metals. These include lead, lead-bismuth eutectic (LBE), sodium-potassium alloy (NaK), and lithium (in addition to sodium). The sensitivities were quantified using liquid metal properties at 350 ° C and 650 ° C. The geometry of the test stand model, all material properties used in the model, and the results are presented in a manner that allows the reader can replicate the model and perform additional analyses.

COMSOL↗