At least 127 records · Page 7

Radiation Dose Testing on Juno High Voltage Cables

The Juno mission to Jupiter will have a highly elliptical orbit taking the spacecraft through the radiation belts surrounding the planet. During these passes through the radiation belts, the spacecraft will be subject to high doses of radiation from energetic electrons and protons with energies ranging from 10 keV to 1 GeV. While shielding within the spacecraft main body will reduce the total absorbed dose to much of the spacecraft electronics, instruments and cables on the outside of the spacecraft will receive much higher levels of absorbed dose. In order to estimate the amount of degradation to two such cables, testing has been performed on two coaxial cables intended to provide high voltages to three of the instruments on Juno. Both cables were placed in a vacuum of 5x10-6 torr and cooled to -50 C prior to exposure to the radiation sources. Measurements of the coaxial capacitance per unit length and partial discharge noise floor indicate that increasing levels of radiation make measurable but acceptably small changes to the F EP Teflon utilized in the construction of these cables. In addition to the radiation dose testing, observations were made on the internal electrostatic charging characteristics of these cables and multiple discharges were recorded.

Juno↗

Crane-Load Contact Sensor

An electronic instrument has been developed as a prototype of a portable crane-load contact sensor. Such a sensor could be helpful in an application in which the load rests on a base in a horizontal position determined by vertical alignment pins (see Figure 1). If the crane is not positioned to lift the load precisely vertically, then the load can be expected to swing once it has been lifted clear of the pins. If the load is especially heavy, large, and/or fragile, it could hurt workers and/or damage itself and nearby objects. By indicating whether the load remains in contact with the pins when it has been lifted a fraction of the length of the pins, the crane-load contact sensor helps the crane operator determine whether it is safe to lift the load clear of the pins: If there is contact, then the load is resting against the sides of the pins and, hence, it may not be safe to lift; if contact is occasionally broken, then the load is probably not resting against the pins, so it should be safe to lift. It is assumed that the load and base, or at least the pins and the surfaces of the alignment holes in the load, are electrically conductive, so the instrument can use electrical contact to indicate mechanical contact. However, DC resistance cannot be used as an indicator of contact for the following reasons: The load and the base are both electrically grounded through cables (the load is grounded through the lifting cable of the crane) to prevent discharge of static electricity. In other words, the DC resistance between the load and the pins is always low, as though they were always in direct contact. Therefore, instead of DC resistance, the instrument utilizes the AC electrical impedance between the pins and the load. The signal frequency used in the measurement is high enough (.1 MHz) that the impedance contributed by the cables and the electrical ground network of the building in which the crane and the base are situated is significantly greater than the contact impedance between the pins and the load. The instrument includes a signal generator and voltage-measuring circuitry, and is connected to the load and the base as shown in Figure 2. The output of the signal generator (typically having amplitude of the order of a volt) is applied to the load via a 50-resistor, and the voltage between the load and the pins is measured. When the load and the pins are not in contact, the impedance between them is relatively high, causing the measured voltage to exceed a threshold value. When the load and the pins are in contact, the impedance between them falls to a much lower value, causing the voltage to fall below the threshold value. The voltage-measuring circuitry turns on a red light-emitting diode (LED) to indicate the lower-voltage/ contact condition. Whenever the contact has been broken and the non-contact/higher-voltage condition has lasted for more than 2 ms, the voltage-measuring circuitry indicates this condition by blinking a green LED.

Youngquist, Robert↗

Cryogenic Behavior of the High Temperature Crystal Oscillator PX-570

Microprocessors, data-acquisition systems, and electronic controllers usually require timing signals for proper and accurate operation. These signals are, in most cases, provided by circuits that utilize crystal oscillators due to availability, cost, ease of operation, and accuracy. Stability of these oscillators, i.e. crystal characteristics, is usually governed, amongst other things, by the ambient temperature. Operation of these devices under extreme temperatures requires, therefore, the implementation of some temperature-compensation mechanism either through the manufacturing process of the oscillator part or in the design of the circuit to maintain stability as well as accuracy. NASA future missions into deep space and planetary exploration necessitate operation of electronic instruments and systems in environments where extreme temperatures along with wide-range thermal swings are countered. Most of the commercial devices are very limited in terms of their specified operational temperature while very few custom-made and military-grade parts have the ability to operate in a slightly wider range of temperature. Thus, it is becomes mandatory to design and develop circuits that are capable of operation efficiently and reliably under the space harsh conditions. This report presents the results obtained on the evaluation of a new (COTS) commercial-off-the-shelf crystal oscillator under extreme temperatures. The device selected for evaluation comprised of a 10 MHz, PX-570-series crystal oscillator. This type of device was recently introduced by Vectron International and is designed as high temperature oscillator [1]. These parts are fabricated using proprietary manufacturing processes designed specifically for high temperature and harsh environment applications [1]. The oscillators have a wide continuous operating temperature range; making them ideal for use in military and aerospace industry, industrial process control, geophysical fields, avionics, and engine control. They exhibit low jitter and phase noise, consume little power, and are suited for high shock and vibration applications. The unique package design of these crystal oscillators offers a small ceramic package footprint, as well as providing both through-hole mounting and surface mount options.

Patterson, Richard↗

Airplane Ice Detector Based on a Microwave Transmission Line

An electronic instrument that could detect the potentially dangerous buildup of ice on an airplane wing is undergoing development. The instrument is based on a microwave transmission line configured as a capacitance probe: at selected spots, the transmission-line conductors are partly exposed to allow any ice and/or liquid water present at those spots to act as predominantly capacitive electrical loads on the transmission line. These loads change the input impedance of the transmission line, as measured at a suitable excitation frequency. Thus, it should be possible to infer the presence of ice and/or liquid water from measurements of the input impedance and/or electrical parameters related to the input impedance. The sensory transmission line is of the microstrip type and thus thin enough to be placed on an airplane wing without unduly disturbing airflow in flight. The sensory spots are small areas from which the upper layer of the microstrip has been removed to allow any liquid water or ice on the surface to reach the transmission line. The sensory spots are spaced at nominal open-circuit points, which are at intervals of a half wavelength (in the transmission line, not in air) at the excitation frequency. The excitation frequency used in the experiments has been 1 GHz, for which a half wavelength in the transmission line is .4 in. (.10 cm). The figure depicts a laboratory prototype of the instrument. The impedance-related quantities chosen for use in this version of the instrument are the magnitude and phase of the scattering parameter S11 as manifested in the in-phase (I ) and quadrature (Q) outputs of the phase detector. By careful layout of the transmission line (including the half-wavelength sensor spacing), one can ensure that the amplitude and phase of the input to the phase detector keep shifting in the same direction as ice forms on one or more of the sensor areas. Although only one transmission-line sensor strip is used in the laboratory version, in a practical application, it could be desirable to install multiple strips on different areas to detect localized icing. In that case, a multiplexer should be used to connect the various strips to the phase detector for sequential measurements. Experiments have been performed with freezing and thawing of water and of water/glycol mixtures. The experiments have shown that, whether or not glycol is present, it is possible to distinguish between liquid water and ice via the I and Q outputs; in particular, the equipment can be adjusted so that when water freezes, I decreases and Q increases. With respect to the operation of this instrument, the main effect of glycol is to increase the freezing or thawing time.

Ngo, Phong↗

Next-Generation Tumbleweed Rover

A document describes a next-generation tumbleweed rover that involves a split balloon system that is made up of two half-spherical air bladders with a disc between them. This disc contains all the electronics and instruments. By deflating only the bottom balloon, the rover can sit, bringing the surface probe into contact with the ground. The bottom balloon has a channel passing through it, allowing the surface probe to reach the surface through the balloon. Once the sample has been gathered and analyzed, the rover can re-inflate the lower air bladder and continue rolling. The rover will use a small set of instruments and electronics situated at the center of its inflatable spherical hull. The current version is a large beach-ball-like construction, about 1.8 m in diameter and weighing roughly 15 kg. The rover comprises two major parts, an outer spherical hull (split in half at the central disc) and an inner, disc-shaped cylindrical section. The balloons are attached to the bottom and top of the disc. Inside the disc, there are temperature and pressure sensors to keep track of the inner and outer conditions of the rover. A system of pumps and valves is responsible for independently inflating and deflating the balloons as necessary. There are also accelerometers to record the movement, together with a GPS receiver. The data are then sent through a modem to a control station. This work builds upon the project Tumbleweed rover for planetary exploration, described in the Technical Support Package.

Nosanov, Jeffrey P.↗

Update on Advection-Diffusion Purge Flow Model

Gaseous purge is commonly used in sensitive spacecraft optical or electronic instruments to prevent infiltration of contaminants and/or water vapor. Typically, purge is sized using simplistic zero-dimensional models that do not take into account instrument geometry, surface effects, and the dependence of diffusive flux on the concentration gradient. For this reason, an axisymmetric computational fluid dynamics (CFD) simulation was recently developed to model contaminant infiltration and removal by purge. The solver uses a combined Navier-Stokes and Advection-Diffusion approach. In this talk, we report on updates in the model, namely inclusion of a particulate transport model.

purging↗

James Webb Space Telescope Core 2 Test - Cryogenic Thermal Balance Test of the Observatorys Core Area Thermal Control Hardware

The James Webb Space Telescope (JWST), successor to the Hubble Space Telescope, will be the largest astronomical telescope ever sent into space. To observe the very first light of the early universe, JWST requires a large deployed 6.5-meter primary mirror cryogenically cooled to less than 50 Kelvin. Three scientific instruments are further cooled via a large radiator system to less than 40 Kelvin. A fourth scientific instrument is cooled to less than 7 Kelvin using a combination pulse-tube Joule-Thomson mechanical cooler. Passive cryogenic cooling enables the large scale of the telescope which must be highly folded for launch on an Ariane 5 launch vehicle and deployed once on orbit during its journey to the second Earth-Sun Lagrange point. Passive cooling of the observatory is enabled by the deployment of a large tennis court sized five layer Sunshield combined with the use of a network of high efficiency radiators. A high purity aluminum heat strap system connects the three instrument's detector systems to the radiator systems to dissipate less than a single watt of parasitic and instrument dissipated heat. JWST's large scale features, while enabling passive cooling, also prevent the typical flight configuration fully-deployed thermal balance test that is the keystone of most space missions' thermal verification plans. This paper describes the JWST Core 2 Test, which is a cryogenic thermal balance test of a full size, high fidelity engineering model of the Observatory's 'Core' area thermal control hardware. The 'Core' area is the key mechanical and cryogenic interface area between all Observatory elements. The 'Core' area thermal control hardware allows for temperature transition of 300K to approximately 50 K by attenuating heat from the room temperature IEC (instrument electronics) and the Spacecraft Bus. Since the flight hardware is not available for test, the Core 2 test uses high fidelity and flight-like reproductions.

JWST Thermal Core 2 Test↗

Thermal Stability Testing of Two-Phase Thermal Control Hardware for the Surface Water Ocean Topography Mission

The thermal architecture for the Surface Water Ocean Topography mission utilizes loop heat pipes and constant conductance heat pipes to transport waste heat (> 1000 Watts) from the instrument electronics to the radiator. The main thermal design risk is the ability to maintain a temporal stability of <0.05 Celsius per minute in a low earth orbit environment. The stringent thermal requirements are part of the overall error budget needed to meet the primary mission science objectives. A testbed was developed to simulate flight-like loads and environments in order to validate the thermal subsystem can meet the temporal stability requirements. Preliminary testing showed that the thermal control system can meet the stability requirement and that loop heat pipes are actually helping to maintain stability during transient sink temperature changes for this specific flight application and boundary conditions.

Somawardhana, Ruwan P.↗

Comprehensive Assessment of Models and Events Using Library Tools (CAMEL) Framework: Time Series Comparisons

The Comprehensive Assessment of Models and Events using Library Tools (CAMEL) framework leverages existing Community Coordinated Modeling Center services: Run on Request post processing tools that generate model time series outputs and the new Community Coordinated Modeling Center Metadata Registry that describes simulation runs using Space Physics Archive Search and Extract metadata. The new CAMEL visualization tool compares the modeled time series with observational data and computes a suite of skill scores such as Prediction Efficiency, Root Mean Square Error, and Symmetric Signed Percentage Bias. Model data pairs used for skill calculations are obtained considering a user selected maximum difference between the time of observation and the nearest model output. The system renders available data for all locations and time periods selected using interactive visualizations that allow the user to zoom, pan, and pick data values along traces. Skill scores are reported for each selected event or aggregated over all events for all participating model runs. Separately, scores are reported for all locations (satellites or stations) and for each location individually. We are building on past experiences with model data comparisons of magnetosphere and ionosphere model outputs from GEM2008, GEMCEDAR Electrodynamics Thermosphere Ionosphere, and the SWPC Operational Space Weather Model challenges. The CAMEL visualization tool is demonstrated using three validation studies: (a) Wang Sheeley Arge heliosphere simulations compared against OMNI solar wind data, (b) ground magnetic perturbations from several magnetosphere and ionosphere electrodynamics models as observed by magnetometers, and (c) electron fluxes from several ring current simulations compared to Radiation Belt Storm Probes Helium Oxygen Proton Electron instrument measurements, integrated over different energy ranges.

Rastätter, Lutz↗

VALENTInE: A Concept for a New Frontiers Class Long Duration In-Situ Balloon Mission to Venus

Venus and Earth are similar in bulk composition, size, density, and approximate distance from the Sun, yet Venus’s modern-day climate and surface geology is distinctly different [1]. Previous missions to Venus revealed unusual volcanic features, possible continental crust, widespread volcanic plains, a weak magnetic field [2], and insights into the Venusian atmosphere [3,4]. Unfortunately, data from these missions were limited in spatial and temporal resolution and global extent. A future mission to Venus is critical to address fundamental questions surrounding the chemical composition and dynamics of the Venusian atmosphere [5], its geologic history [6,7], its internal structure [8,9], and its habitability throughout time [10,11]. We present the Venus Air and Land Expedition: a Novel Trailblazer for In situ Exploration (VALENTInE) mission to meet this need. VALENTInE is a variable altitude balloon that will passively float in Venus’s atmosphere between 45 and 55 km altitude. VALENTInE will acquire atmospheric data at varying latitudes and longitudes in addition to mapping the surface geomorphology and mineralogy across multiple terrains. Mission Objectives: The VALENTInE mission concept is driven by four main science objectives: 1. Determine whether the driving force of the superrotation of Venus’s atmosphere is caused by horizontal or vertical momentum transport. 2. Determine whether the atmospheric composition and noble gas inventory of the Venusian atmosphere is a product of outgassing from the initial protoplanetary source or if there are significant contributions from exogenic sources. 3. Determine whether the tesserae regions (particularly Aphrodite Terra) are felsic and relatively older than surrounding regions. 4. Determine if there is any evidence of a recent dynamo preserved in the rock record of Venus. Mission Overview: A balloon architecture provides a robust system that can survive long-term in the Venusian environment while taking accurate measurements of the lower cloud deck and surface. Two prior balloon missions to Venus, VEGA 1 and VEGA 2 in 1984, have demonstrated the potential for such planetary exploration; however, these missions were short-lived (46 hr), with limited range (54 km). Our spacecraft concept consists of a battery powered balloon with a gondola and flyby carrier stage (Fig. 1). Our novel design allows for at least 15 days of atmospheric exploration, including multiple ascents and descents in the Venus atmosphere. VALENTInE is baselined to launch in 2032, cruise on solar power for 128 days, enter, descend, and inflate (EDI) into Venus’s atmosphere above Aphrodite Terra, and float in Venus’s atmosphere for a total nominal mission duration of 15 days. The balloon, able to control its altitude by changing its buoyancy, will make one full circumnavigation every 4–8 days and move poleward ~1 o latitude per day; it will be passively directed by the horizontal air currents on Venus. The balloon can only be controlled in the z direction, and the expected latitude range is ±10° from EDI. The balloon itself will be a tracer for atmospheric structures such as zonal winds [5, 12]. During the 15-day operational period, there will be five dips to 45 km for a compositional study of the lower atmosphere and geological and magnetic mapping of the surface. Dips are used to take images and measurements closer to the surface and to obtain in situ vertical atmospheric profiles between 45 and 55 km. Instruments: The VALENTInE instrument payload will allow for extensive study of the geology, atmosphere, and interior of Venus. The instrument suite consists of six instruments. The mission profile for each instrument is shown in Fig. 2. Lower Atmosphere Meteorology Analyzer (LAMA) is an atmospheric structure instrument consisting of a thermometer, barometer, and accelerometer to continuously measure temperature and pressure as a function of altitude, longitude, and latitude. TracE and Noble Gas Investigator (TENGI) is aneutral mass spectrometer used to sample the dense atmosphere. TENGI will operate continuously at 45 km and 55 km and will measure D/H ratios, as well as Ne, Ar, and O isotopic ratios. Kilometer Scale Spectral Imager (KSSI) is amultispectral imager (850-1150 nm) used to resolve surface features on the order of km. Near InfraRed Multispectral Photometer (NIRMP) is an Infrared (IR) photometer used to image the surface through the clouds to characterize mineral assemblages at five different areas of the surface. NIRMP will be operated during dwell. ELevation REConnaissance (ELREC) is a light detection and ranging (LIDAR) instrument used for measuring topography at five different areas of the surface. The ELREC data will be combined with those of NIRMP to determine mineral assemblages and how they correlate to topography. Magnetic Exploration and Interior Detective (MEID) is a magnetometer used to detect any near-surface magnetic anomalies. The magnetometer will continuously operate at all altitudes. Mission Design: The spacecraft’s propulsion system will have a wet mass of 930 kg and will be launched on an Atlas V rocket. The spacecraft will jettison the payload upon arrival in Venus’s atmosphere before decelerating to orbital velocity. Figure 2. Notional power-dip profile while the balloon is on the dayside. Risks and Challenges: Raising and lowering the spacecraft to dip beneath the haze layer require a large amount of energy. This issue was partly compensated by limiting the number of dips over the 15 day prime mission. Power needs for pumping helium are reduced by slowing the descent speed, which consequently increases spatial resolution of in situ measurements between 45 and 55 km. The main limitation for the duration of the mission is the need to carry 15 days’ worth of batteries. The bus experiences external Venusian temperatures ranging from ~27°C at 55 km altitude to ~110°C at 45 km altitude. These high atmospheric temperatures require thermal protection for the bus (instruments, electronics, and flight systems) during its descent, dwell at 45 km, and ascent. The bus is maintained at a mechanically safe temperature range of -10°C to 50°C using white external paint, multi-layer insulation (MLI), mechanical/thermal isolation (e.g. Ti, composites), and ~57 kg of Phase Change Materials (PCM). Images and spectra taken below the haze dominate the available data transmission regardless of the time spent at 45 km. Therefore, less time at the lower altitude mainly reduces the coverage of in situ measurements there. Further, we assumed an unrealistically low-density material for the helium storage tanks on the gondola. However, this issue is partially resolved if we were to jettison 75% of the spent helium storage tanks. After the entry process, the balloon volume remains mostly inflated and storage tanks are required only for reducing balloon volume in dipping to 45 km. This mission was planned against an expected New Frontiers 5 (NF5) cost cap of $1B, as the NF5 call had not yet been released. The mission we describe fits within the predicted cost cap if the flyby carrier stage, responsible for powering the spacecraft during cruise and for relaying in situ measurements back to Earth, can be contributed by another space agency. Acknowledgments: We thank the JPL Planetary Science Summer School, especially A. Nash, J. Scully, K. Mitchell, L. Lowes, and J. Armijo, and our mentors from JPL Team X. Thank you to our review panel for their insightful review. References: [1] Kane, S. et al. (2019) JGR:Ps, 124 , 2015–2028. [2] Phillips, J. L., & Russell, C. T. (1987). JGR: Space Physics , 92 (A3), 2253-2263. [3] Nakamura, M. et al. (2018) Earth Planets Space, 70 (1), 144. [4] Svedhem, H. et al. (2009) JGR:P 114 (E5). [5] Limaye et al. (2009) Decadal Survey White Paper . [6] Ivanov, M. and Head, J. (2011) PSS, 59 (13) , 1559-1600. [7] Smrekar, S. et al. (2018) Space Sci Rev, 214 (5), 88. [8] O’Rourke, J. et al. (2018) EPSL, 502 , 46-56. [9] O’Rourke J. et al. (2019) GRL , (46), 5768–5777 [10] Way, M. et al. (2016) GRL, 43 (16), 8376-8383. [11] Way, M. et al. (2020) JGR:P, 125 (5), e2019JE006276. [12] Preston, R. A. et al. (1986) Science, 231 (4744), 1414-1416.

Mission Concept↗

Ulysses Plasma Observations in the Jovian Magnetosheath

The solar wind plasma experiment aboard the Ulysses spacecraft, including separate ion and electron instruments, measured the plasma properties of the Jovian magnetosheath during the February 1992 encounter with Jupiter. Seven separate magnetosheath intervals were observed, as well as four bow shock crossings and numerous encounters with the magnetopause and its boundary layer.

Ulysses↗

The Sciencecraft Process

In this paper, the authors propose a new process for the development and operation of inmanned vehicles for the exploration of space. We call the vehicle Sciencecraft to distinguish it from the more traditional vehicle Spacecraft. A Sciencecraft is an integrated unit that combines science instruments, electronics, telecommunications, power, and propulsion elements into a single system.

spacecraft↗

FPGA-based hardware/software co-design instrument command-and-control solutions

Traditional design methodology dictates that an instrument electronics platform should consist of a printed circuit board (PCB)—often multiple boards—populated with many components and support electronics. More specifically, each subsystem is composed of numerous integrated circuits (ICs) spread across the board(s), connected with innumerable traces and wires. Additionally, it is often the case that the hardware and software design teams are quite separated—the hardware team designs a board and hands it to a software team, who must then deal with any hardware quirkiness and may need to rewrite software due to inadequately defined interfaces...

Allen, Mark A.↗

Construction and evaluation of an imaging focussed-mesh electron multiplier for space instrumentation

A focused-mesh electron multiplier (FMEM) has been combined with a wedge and strip position-sensitive anode to create a novel detector that is considered likely to have a number of applications in space astronomy and laboratory image sensing. Results from the first application of a wedge and strip anode to an FMEM are presented including spatial resolution, spatial linearity, background rate, and pulse risetime. The converted multiplier retains the attributes of an FMEM that made it attractive in the first place, such as low background, high speed, and high dynamic range.

Vallerga, J.↗

Measuring Moisture in Sealed Electronic Enclosures

Instrument checks trace amounts accurately. Moisture in hermeticallysealed electronic equipment measured by instrument designed for field use. Instrument also measures pressure, volume, and contaminants of gas in sealed enclosure. Plumbing for instrument uses vacuum-tight valves so any portion of instrument cleansed by opening certain valves to vacuum source. To ensure accuracy, manifolds are of minimal volume, each comprising only volume within cross-shaped tubing fittings.

Krieg, Herman C., Jr.↗

Characterization of runaway electron impact on instrumented sacrificial limiters on DIII-D

Instrumented sacrificial limiter heads, both domed (proud) and flat (flush) are used in DIII-D runaway electron (RE) wall strikes to study the wall impact dynamics with high spatial and time resolution. The approximate structure of the RE wetted area and heating depth on the domed limiter heads were predicted qualitatively using orbit-tracking simulations, although a strong left–right asymmetry (about the magnetic field direction) was not captured well by the simulations. It is hypothesized that this difference is perhaps due to the local 3D magnetic field perturbation of the dome limiter head. The average kinetic energy K and pitch angle θ of REs striking the limiter head were estimated from the spatial distribution of local HXR emission and were estimated to be roughly K ≈ 4 MeV and θ ≈ 0.2 rad. These values are roughly consistent with in-plasma values estimated before the loss event, indicating that RE kinetic energy and pitch angle are not drastically altered when transporting to the wall. Large shot–shot variations (1–10 kJ) in energy deposition into the limiter head were observed and were explained by shot–shot variations in locked magneto-hydrodynamics mode toroidal phase. For the largest deposited energies (10 kJ), graphite material failure and explosive dust release was observed, and the depth of material failure at higher energy deposition was successfully reproduced using modelling of volumetric energy deposition and brittle failure. The presence of energetic (keV) level ion impact during the RE wall strike was confirmed by three different surface analysis techniques. The ratio of energetic ion to RE flux appears to be larger on flat surfaces within the RE wetted area, although the energetic ion flux and total energy flux due to energetic ions have not yet been quantified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Specifying and calibrating instrumentations for wideband electronic power measurements

The wideband electric power measurement related topics of electronic wattmeter calibration and specification are discussed. Tested calibration techniques are described in detail. Analytical methods used to determine the bandwidth requirements of instrumentation for switching circuit waveforms are presented and illustrated with examples from electric vehicle type applications. Analog multiplier wattmeters, digital wattmeters and calculating digital oscilloscopes are compared. The instrumentation characteristics which are critical to accurate wideband power measurement are described.

Lesco, D. J.↗

An electronic circuit for sensing malfunctions in test instrumentation

Monitoring device differentiates between malfunctions occurring in the system undergoing test and malfunctions within the test instrumentation itself. Electronic circuits in the monitor use transistors to commutate silicon controlled rectifiers by removing the drive voltage, display circuits are then used to monitor multiple discrete lines.

Miller, W. M., Jr.↗