Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy consumption reductions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Decision making for implementing non-traditional water sources: a review of challenges and potential solutions

Abstract The effects of climate change, population growth, and future hydrologic uncertainties necessitate increased water conservation, new water resources, and a shift towards sustainable urban water supply portfolios. Diversifying water portfolios with non-traditional water sources can play a key role. Rooftop harvested rainwater (RHRW), atmospheric and condensate harvesting, stormwater, recycled wastewater and greywater, and desalinated seawater and brackish water are all currently utilized and rapidly emerging non-traditional water sources. This review explores the status and trends around these non-traditional water sources, and reviews approaches and models for prioritizing, predicting, and quantifying metrics of concern. The analysis presented here suggests that understanding the challenges of location specific scenarios, socioeconomic knowledge gaps, water supply technologies, and/or water management structure is the crucial first step in establishing a model or framework approach to provide a strategy for improvement going forward. The findings of this study also suggest that clear policy guidance and onsite maintenance is necessary for variable water quality concerns of non-traditional sources like harvested rainwater and greywater. In addition, use of stormwater or reuse of wastewater raises public health concerns due to unknown risks and pathogen levels, thus rapid monitoring technologies and transparent reporting systems can facilitate their adoption. Finally, cost structure of desalination varies significantly around the world, largely due to regulatory requirements and local policies. Further reduction of its capital cost and energy consumption is identified as a hurdle for implementation. Overall, models and process analyses highlight the strength of comparative assessments across scenarios and water supply options.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamics of Permanent-Magnet Biased Active Magnetic Bearings

Active magnetic radial bearings are constructed with a combination of permanent magnets to provide bias forces and electromagnets to generate control forces for the reduction of cost and the operating energy consumption. Ring-shaped permanent magnets with axial magnetization are attached to a shaft and share their magnet stators with the electromagnets. The magnet cores are made of solid iron for simplicity. A simplified magnetic circuit of the combined magnet system is analyzed with linear circuit theory by approximating the characteristics of permanent magnets with a linear relation. A linearized dynamical model of the control force is presented with the first-order approximation of the effects of eddy currents. Frequency responses of the rotor motion to disturbance inputs and the motion for impulsive forces are tested in the non-rotating state. The frequency responses are compared with numerical results. The decay of rotor speed due to magnetic braking is examined. The experimental results and the presented linearized model are similar to those of the all-electromagnetic design.

Fukata, Satoru↗

Reducing the cost of home energy upgrades in the US: An industry survey

Decarbonizing the US residential building stock requires a substantial acceleration in home energy upgrades. Numerous barriers exist to accelerating adoption of efficient and electric building technologies, but foremost among these is high upfront costs. This study uses an industry survey delivered to a sample of home energy professionals to examine promising cost reduction strategies across a range of project types, including HVAC, water heating, and envelope/insulation projects. The survey included quantitative and qualitative questions to collect evidence on the estimated cost reduction potential of these strategies and their likelihood of use in the construction industry. The 167 survey respondents included contractors, energy consultants, architects, manufacturers, and others with experience in delivering energy upgrades in single-family and multifamily buildings in the US. Results show that significant cost reductions are achievable by minimizing additional infrastructure costs (such as replacing electric panels), streamlining project planning/management, and deploying innovations that simplify installation. We find that for a typical deep retrofit project, including heat pumps for space and water heating in addition to envelope upgrades, the strategies could result in a total installed cost reduction of nearly 50%, dramatically improving the customer economics of such a project. This research makes a novel contribution to the literature on strategies to reduce the costs of residential retrofits. We discuss how our study's insights on the highest-value cost reduction strategies for home energy upgrades can further accelerate their uptake in the US housing stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coloured low-emissivity films for building envelopes for year-round energy savings

We report that buildings are responsible for over 40% of total US energy use, of which about 40% is directly related to the operation of heating, ventilation and air-conditioning (HVAC) systems. Saving energy to heat and cool buildings would contribute substantially to sustainability. Here we propose a category of coloured low-emissivity films for building walls that constitute the main component of the building thermal envelope. We demonstrate high reflectance (~90%) in infrared wavelength range and selective reflectance in the visible light wavelength range for desired colours. These films can help minimize radiative heat exchange between the indoor and outdoor environments, thus saving energy for all-year cooling and heating while satisfying the required aesthetical effect. Simulations show that these films can help reduce heat gain and loss by up to 257.6 MJ per installation wall area annually. In the case of a typical midrise apartment building, the HVAC system can save up to 124.46 GJ (equal to 9.87% of the building’s HVAC energy consumption). By rough estimation, a global CO 2 emission reduction of 1.14 billion metric tons annually could be achieved. Our work provides insights for innovative energy-saving building envelope materials that can help achieve global carbon neutrality and sustainability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Thin Triple-Pane Windows in the PNNL Lab Homes

In recent years, improvements in glass manufacturing have allowed the production of thin triple-pane windows, which are manufactured with a thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy is sponsoring laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. To examine the performance of thin triple-pane windows, the Pacific Northwest National Laboratory (PNNL) evaluated the windows at the PNNL Lab Homes, a matched pair of homes located on PNNL’s campus in Richland, Washington. In this study, one Lab Home contained a complete set of nine thin triple-pane windows, while the other Lab Home contained baseline double-pane windows. The Lab Homes experiments demonstrated significant that replacing clear glass double-pane windows with thin triple-pane windows provided year-round energy savings and reduced peak demand both in the heating and cooling seasons. The Lab Homes experiments also validated other performance benefits of the thin triple-pane windows including reduced condensation potential, more even temperatures throughout the home and near the windows, and reduced sound attenuation through the windows, leaving the home quieter and more comfortable for the occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Techno-Economic Assessment of Residential Heat Pump Integrated with Thermal Energy Storage

Phase change material (PCM)-based thermal energy storage (TES) can provide energy and cost savings and peak demand reduction benefits for grid-interactive residential buildings. Researchers established that these benefits vary greatly depending on the PCM phase change temperature (PCT), total TES storage capacity, system configuration and location and climate of the building. In this study, preliminary techno-economic performance is reported for a novel heat pump (HP)-integrated TES system using an idealized approach. A simplified HP-TES was modeled for 1 year of space heating and cooling loads for a residential building in three different climates in the United States. The vapor compression system of the HP was modified to integrate with TES, and all heat transfer to and from the TES was mediated by the HP. A single PCM was used for heating and cooling, and the PCT and TES capacity were varied to observe their effects on the building’s energy consumption, peak load shifting and cost savings. The maximum reduction in electric consumption, utility cost and peak electric demand were achieved at a PCT of 30 °C for New York City and 20 °C for Houston and Birmingham. Peak energy consumption in Houston, New York City, and Birmingham was reduced by 47%, 53%, and 70%, respectively, by shifting peak load using a time-of-use utility schedule. TES with 170 MJ storage capacity allowed for maximum demand shift from on-peak to off-peak hours, with diminishing returns once the TES capacity equaled the daily building thermal loads experienced during the most extreme ambient conditions.

25 ENERGY STORAGE↗

Biomass Resources and Emission Reduction Potential of Agricultural and Livestock Residues in Mainland China from 2013 to 2022

Controlling carbon emissions is a global goal, and China is actively implementing carbon reduction measures. As a major agricultural nation, China has considerable potential for developing agricultural residues as renewable and environmentally friendly biomass energy. In this study, we obtained data on crop yields, crop-to-grain ratios, and livestock excretion coefficients to calculate the biomass resources of agricultural and livestock residues in Chinese provinces from 2013 to 2022. Crop residue biomass resources showed a distribution pattern with higher levels in the north than in the south and the east than in the west. Henan and Heilongjiang provinces consistently had the highest resource levels, exceeding 35 million tons annually for 10 years. The biomass resources from livestock residues were relatively abundant in Sichuan, Henan, Yunnan, Shandong, Hunan, and Inner Mongolia. Inner Mongolia, Sichuan, Shandong, and Henan had the greatest potential for CO2 emission reductions, primarily located in regions abundant in biomass resources and with high traditional energy consumption levels. ArcGIS was used to apply natural break classification to categorize the potential for emission reductions from agricultural and livestock residues across China from 2013 to 2022 into five classes. Based on factors such as crop planting area and livestock numbers, the spatiotemporal distribution of factors influencing the quantity of biomass resources was examined using Geographically and Temporally Weighted Regression. A tailored and integrated approach should be used for biomass, and the development of biomass energy should be promoted through policy support and technological innovation.

Environmental Sciences & Ecology↗

An Electrochemical Hydrogen-Looping System for Low-Cost CO 2 Capture from Seawater

Carbon dioxide (CO 2 ) capture from seawater is a viable, long-term solution for addressing legacy carbon pollution on the planet. However, significant challenges to widespread applicability exist in terms of efficiency, cost, and scalability. In this work, we have developed an electrochemical hydrogen-looping (EHL) system that capitalizes on the generation of proton and OH – from seawater. A CO 2 capture efficiency as high as 91% is achieved for our EHL flow cell. We have demonstrated that the electrochemical hydrogen-looping flow cell can remove CO 2 from simulated seawater at a record low electric energy consumption of 660 kWh ton –1 CO 2 , which is a significant reduction of 56% compared with the currently used bipolar membrane electrodialysis technology. In conclusion, the electrochemical hydrogen-looping flow cell with its much lower energy consumption provides an economical approach for direct removal of CO 2 from seawater at practical scale.

Electrical energy↗

Wheat respiratory O2 consumption falls with night warming alongside greater respiratory CO2 loss and reduced biomass

Abstract Warming nights are correlated with declining wheat growth and yield. As a key determinant of plant biomass, respiration consumes O2 as it produces ATP and releases CO2 and is typically reduced under warming to maintain metabolic efficiency. We compared the response of respiratory O2 and CO2 flux to multiple night and day warming treatments in wheat leaves and roots, using one commercial (Mace) and one breeding cultivar grown in controlled environments. We also examined the effect of night warming and a day heatwave on the capacity of the ATP-uncoupled alternative oxidase (AOX) pathway. Under warm nights, plant biomass fell, respiratory CO2 release measured at a common temperature was unchanged (indicating higher rates of CO2 release at prevailing growth temperature), respiratory O2 consumption at a common temperature declined, and AOX pathway capacity increased. The uncoupling of CO2 and O2 exchange and enhanced AOX pathway capacity suggest a reduction in plant energy demand under warm nights (lower O2 consumption), alongside higher rates of CO2 release under prevailing growth temperature (due to a lack of down-regulation of respiratory CO2 release). Less efficient ATP synthesis, teamed with sustained CO2 flux, could thus be driving observed biomass declines under warm nights.

Posch, Bradley C. (ORCID:0000000309246608)↗

Advanced Shuttle Strategies for Parallel QCCD Architectures

Trapped ions (TIs) are at the forefront of quantum computing implementation, offering unparalleled coherence, fidelity, and connectivity. However, the scalability of TI systems is hampered by the limited capacity of individual ion traps, necessitating intricate ion shuttling for advanced computational tasks. The quantum charge-coupled device (QCCD) framework has emerged as a promising solution, facilitating ion mobility for universal quantum computation. Current QCCD architectures predominantly feature a linear topology, which is increasingly recognized as inefficient for complex quantum operations. Anticipating the shift toward more efficacious designs, this article introduces an innovative quantum scheduling strategy optimized for parallel QCCD topologies. Our strategy proposes a probabilistic formula for ion movement, alongside ingenious methods for local layer generation and layer compression, yielding a significant reduction in ion shuttle times. Through simulations, we demonstrate that our strategy not only substantially outstrips the linear model but also exhibits better performance over other parallel strategies that employ greedy algorithms. This is achieved through our nuanced resolution of complexities, such as traffic blocks and trap capacity limitations. The consequent reduction in shuttle operations leads to lower energy consumption and an enhancement in the quantum computer's fidelity, ultimately accelerating program execution times.

43 PARTICLE ACCELERATORS↗

Human Factors and Technologies Design to Improve User Acceptance of Pooled Rideshare for Increasing Transportation System Energy Efficiency

This multi-year project delivered a comprehensive, human-factors-driven framework to understand, model, and improve pooled rideshare (PR) adoption in the United States. Through three large-scale national survey studies involving more than 16,000 participants across multiple cities and demographic groups, the research established one of the most extensive datasets to date on user perceptions, behavioral barriers, and service expectations related to pooled rideshare. These data revealed key human factors barriers of user acceptance of PR and suggested potential actionable experience optimizations that could lead to increased PR usage. This foundational knowledge guided the development of novel human-factors models and behavioral choice models that quantify how psychological, demographic, and trip-level factors influence willingness to pool. Building on these empirical insights, the project developed advanced behavioral modeling tools, including mixed logit and integrated choice and latent variable models, to capture both observable and latent influences on PR adoption. These models significantly improved the ability to predict riders’ acceptance of pooled trips, explaining choice heterogeneity through latent constructs such as safety, service experience, privacy concerns, time sensitivity, and environmental attitudes. Together, these models provide a robust analytical foundation for designing PR systems that more effectively meet user needs. The project translated human-factors insights and behavioral models into actionable technology innovations by extending POLARIS—an agent-based, activity-based travel simulation platform—into a fully functional pooled rideshare simulation environment. New PR modules, acceptance models, and regional scenarios were implemented for Greenville, SC and Austin, TX, enabling high-fidelity validation of algorithmic strategies under realistic demand and traffic conditions. The simulation platform supported the development and evaluation of adaptive discount-based assignment algorithms, enhanced willingness-to-pay formulations, demographic-aware incentive mechanisms, and a proactive joint assignment and repositioning strategy. Simulation results demonstrated substantial gains in pooling uptake, average vehicle occupancy, energy efficiency, and fleet profitability. In Greenville, pooling adoption more than doubled, while reductions in vehicle-miles traveled and energy consumption were significant. In Austin, pooling improvements were achieved with minimal service-quality trade-offs, and profitability increased across all fleet sizes. Through this research, we developed a comprehensive understanding of the human factors barriers that limit user acceptance of pooled rideshare services. These insights enabled the design of human-factors-aware pooled rideshare technologies that more effectively address user concerns and improve adoption rates. By integrating these models into an advanced agent-based simulation framework, we demonstrated that higher adoption of pooled rideshare can lead to measurable improvements in energy efficiency and system performance. Together, these contributions establish a validated pathway from human-centered analysis to technology development and energy-saving outcomes, supporting national goals for more sustainable and efficient mobility systems.

Jia, Yunyi↗

Evaluation of Electrodialysis Desalination Performance of Novel Bioinspired and Conventional Ion Exchange Membranes with Sodium Chloride Feed Solutions

Electrodialysis (ED) desalination performance of different conventional and laboratory-scale ion exchange membranes (IEMs) has been evaluated by many researchers, but most of these studies used their own sets of experimental parameters such as feed solution compositions and concentrations, superficial velocities of the process streams (diluate, concentrate, and electrode rinse), applied electrical voltages, and types of IEMs. Thus, direct comparison of ED desalination performance of different IEMs is virtually impossible. While the use of different conventional IEMs in ED has been reported, the use of bioinspired ion exchange membrane has not been reported yet. The goal of this study was to evaluate the ED desalination performance differences between novel laboratory‑scale bioinspired IEM and conventional IEMs by determining (i) limiting current density, (ii) current density, (iii) current efficiency, (iv) salinity reduction in diluate stream, (v) normalized specific energy consumption, and (vi) water flux by osmosis as a function of (a) initial concentration of NaCl feed solution (diluate and concentrate streams), (b) superficial velocity of feed solution, and (c) applied stack voltage per cell-pair of membranes. A laboratory‑scale single stage batch-recycle electrodialysis experimental apparatus was assembled with five cell‑pairs of IEMs with an active cross-sectional area of 7.84 cm2. In this study, seven combinations of IEMs (commercial and laboratory-made) were compared: (i) Neosepta AMX/CMX, (ii) PCA PCSA/PCSK, (iii) Fujifilm Type 1 AEM/CEM, (iv) SUEZ AR204SZRA/CR67HMR, (v) Ralex AMH-PES/CMH-PES, (vi) Neosepta AMX/Bare Polycarbonate membrane (Polycarb), and (vii) Neosepta AMX/Sandia novel bioinspired cation exchange membrane (SandiaCEM). ED desalination performance with the Sandia novel bioinspired cation exchange membrane (SandiaCEM) was found to be competitive with commercial Neosepta CMX cation exchange membrane.

42 ENGINEERING↗

Building Operation Model (Morpheus) for Dallas Fort Worth Airport (CRADA CRD-19-16301 Final Report)

The primary objective of this project was to leverage digital twin technology to enhance the design and operation of DFW Airport terminals and their associated energy systems. To achieve this, Morpheus, a building digital twin, was developed to guide improvements in airport operations, specifically targeting reductions in peak power demand and overall energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methods of reducing energy consumption of the oxidant supply system for MHD/steam power plants

An in-depth study was conducted to identify possible improvements to the oxidant supply system for combined cycle MHD power plants which would lead to higher thermal efficiency and reduction in the cost of electricity, COE. Results showed that the oxidant system energy consumption could be minimized when the process was designed to deliver a product O2 concentration of 70 mole percent. The study also led to the development of a new air separation process, referred to as liquid pumping and internal compression. MHD system performance calculations show that the new process would permit an increase in plant thermal efficiency of 0.6 percent while allowing more favorable tradeoffs between magnetic energy and oxidant system capacity requirements.

A. J Juhasz↗

Methods of reducing energy consumption of the oxidant supply system for MHD/steam power plants

An in-depth study was conducted to identify possible improvements to the oxidant supply system for combined cycle MHD power plants which would lead to higher thermal efficiency and reduction in the cost of electricity, COE. Results showed that the oxidant system energy consumption could be minimized when the process was designed to deliver a product O2 concentration of 70 mole percent. The study also led to the development of a new air separation process, referred to as 'liquid pumping and internal compression'. MHD system performance calculations show that the new process would permit an increase in plant thermal efficiency of 0.6 percent while allowing more favorable tradeoffs between magnetic energy and oxidant system capacity requirements.

Juhasz, A. J.↗

Canadian Oil Sands Extraction and Upgrading: A Synthesis of the Data on Energy Consumption, CO 2 Emissions, and Supply Costs

As Canadian crude bitumen production from oil sands has increased in recent decades, the nation’s oil and gas industry has become a significant contributor to national greenhouse gas emissions. Canada has developed carbon emission reduction targets to meet its Nationally Determined Contributions and Mid-Century Strategy goals. A detailed profile of energy consumption pathways in the oil sands industry is necessary to identify potential areas of improvement and to monitor progress toward meeting emissions reduction targets. Much of the existing literature for oil sands modeling provides input assumptions with different technological boundaries. For a set of oil sands extraction and upgrading technologies, this study first reviews the literature and then quantifies energy input requirements, CO 2 emissions, and operating costs for a set of consistent technological boundaries and energy units. Summary results refer to requirements and costs at the production facility, excluding transportation and blending costs. An energy system diagram of oil sands production that matches these boundaries is provided, which can be used by integrated assessment models, oil sands companies, and government ministries to evaluate the present and future energy consumption and emissions pathways of the oil sands industry.

02 PETROLEUM↗

ComStock Measure Scenario Documentation: Reduced Thermostat Setbacks for Heat Pumps

This report provides documentation of a measure for the End Use Savings Shapes project, which consists of analysis of different energy efficiency and renewable energy measures on the commercial building stock, using NREL's ComStock tool. The measure consists of a reduction in thermostat setbacks for air-source heat pump RTUs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing and Reducing Plug and Process Loads in Office Buildings

Plug and process loads (PPLs) account for 33% of U.S. commercial building electricity consumption (McKenney et al. 2010). (See Figure 1.) Minimizing these loads is a significant challenge in the design and operation of an energy-efficient building. Lobato et al. (2011) and Lobato et al. (2012) define PPLs as energy loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and that typically do not provide comfort to the occupants. The percentage of total building energy use from PPLs is increasing. According to the U.S. Department of Energy (DOE), by 2030, commercial building energy consumption is expected to increase by 24%; PPL energy consumption is anticipated to increase by 49% in the same time frame (DOE 2010). These trends illustrate the importance of PPL energy reduction to achieve an overall goal of reducing whole-building energy consumption.

30 DIRECT ENERGY CONVERSION↗