Laboratory and Field Testing of Commercially Available Detectors for the Identification of Chemicals of Interest in the Nuclear Fuel Cycle for the Detection of Undeclared Activities

Traditionally, IAEA inspectors have focused on the detection of nuclear indicators as part of infield inspection activities. The ability to rapidly detect and identify chemical as well as nuclear signatures can increase the ability of IAEA inspectors to detect undeclared activities at a site. Identification of chemical indicators have been limited to use in the analysis of environmental samples. Although IAEA analytical laboratories are highly effective, environmental sample processing does not allow for immediate or real-time results to an IAEA inspector at a facility. During a complementary access inspection, under the Additional Protocol, the use of fieldable technologies that can quickly provide accurate information on chemicals that may be indicative of undeclared activities can increase the ability of IAEA to effectively and efficiently complete their mission. The Complementary Access Working Group (CAWG) is a multi-laboratory team with members from Brookhaven National Laboratory, Idaho National Laboratory, Los Alamos National Laboratory, and Sandia National Laboratory. The team identified chemicals at each stage of the nuclear fuel cycle that may provide IAEA inspectors with indications that proliferation activities may be occurring. The group eliminated all indicators related to equipment, technology and training, developing a list of by-products/effluents, non-nuclear materials, nuclear materials, and other observables. These proliferation indicators were prioritized based on detectability from a conduct of operations (CONOPS) perspective of a CA inspection (for example, whether an inspector actually can access the S&O or whether it is in process with no physical access), and the IAEA’s interest in the detection technology in conjunction with radiation detectors. The list was consolidated to general categories (nuclear materials from a chemical detection technique, inorganic chemicals, organic chemicals, halogens, and miscellaneous materials). The team then identified commercial off the shelf (COTS) chemical detectors that may detect the chemicals of interest. Three chemical detectors were selected and tested both in laboratory settings and in field operations settings at Idaho National Laboratory. The instruments selected are: Thermo Scientific TruDefender FT (FTIR), Thermo Scientific FirstDefender RM (Raman), and Bruker Tracer III SD (XRF). Functional specifications, operability, and chemical detectability, selectivity, and limits of detection were determined. Results from the laboratory and field tests will be presented. This work is supported by the Next Generation Safeguards Initiative, Office of Nonproliferation and International Security, National Nuclear Security Administration.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Effect of Plutonium on Uranium Oxide Microstructural Fingerprint

The analysis of particulates from environmental sampling is routinely performed for nuclear forensics applications. In order to increase the tools available for nuclear forensics applications, capability development materials (CDMs), or reference particulates, are necessary for developing and benchmarking new analytical methods. Historically, these CDM particulates have been produced with highly controlled and characterized isotopic and size parameters for applications in developing and benchmarking particle sizers and mass spectrometry analytical methods [1- 4]. However, the development of CDMs with highly characterized particle morphology and phase of the particles is vital for aiding in the development and benchmarking of particle analytical methods for those parameters. In many cases, key properties such as crystallographic phase, morphology, and microstructure, may be correlated to processing history of environmental sampling particulates [5]. To that end, this work investigates determining the structural fingerprint of produced Pu-doped uranium oxide CDMs using transmission electron microscopy (TEM). The particulates, one of which shown in Figure 1, were synthesized to Fig. 1. Single particulate of uranium oxide fabricated using the THESEUS technique. develop capabilities for environmental sampling investigations. These particles are monodisperse at diameter of 1 μm and a range of plutonium concentrations from 0- 1,000 ppm. Given their small diameter, TEM analysis was ideal for studying the particulate structural fingerprint in detail. Previous investigations confirmed the external homogeneity of the particulates at different plutonium concentrations, however this analysis focuses on determining the grain structure, phase distribution, and porosity of the particulates.

Mayer, Jack [Univ. of Florida, Gainesville, FL (Un↗

Characterization of a large-area iQID imager for safeguards applications

Environmental sampling and sample analyses by the International Atomic Energy Agency is a key method for verifying declarations in international safeguards agreements. Quantitative Digital Autoradiography for Environmental Samples is a system developed by Pacific Northwest National Laboratory to examine environmental swipe samples (ESS) prior to subsequent, destructive analysis. This approach is passive and noninvasive for imaging beta and gamma emissions, which transmit through the plastic bags containing the ESS. Alpha particle imaging is also possible with different ESS containers. This technology is based on a portable, real-time, event-counting, high spatial resolution system called iQID (ionizing-radiation Quantum Imaging Detector), which is made from commercial, off-the-shelf components. This includes a scintillator in direct contact with a micro-channel plate image intensifier and a lens for imaging the intensified scintillation events onto a CCD/CMOS camera. The QDARES large-area iQID includes a fiber-optic taper coupled to the image intensifier which increases the imaging area to a ~100 cm square with a 105 mm x 105 mm taper. In this study, we describe new characterization results, including spatial resolution, energy response, minimum detectable activity for several isotopes, detector uniformity, and count-rate capability.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Moving toward automated µFTIR spectra matching for microplastic identification: addressing false identifications and improving accuracy

Abstract Infrared spectroscopy is a widely used tool for studying microplastics and identifying microparticles. Researchers rely on spectral libraries to differentiate between synthetic and natural materials. Unfortunately, spectral library matching is not perfect, and best practices require researchers to use time consuming, manual peak matching to assess spectral matches. Moving toward automated matching requires increased confidence in the matching process. Using spectra matching software may increase the efficiency of particle identification, however some matching strategies may confuse natural materials such as cotton, silk, and plant matter with common classes of synthetics such as polyesters and polyamides. In this experiment, we prepared 22 pristine sample materials from natural and synthetic sources and measured micro-Fourier transform infrared (µFTIR) spectra in transmission mode for each sample using a Thermo Nicolet iN10 MX instrument. The collected spectra were then input into two spectral library matching systems (Omnic Picta and Open Specy), using a total of five identification routines. Next, we placed a subset of four pristine microplastic materials in a biologically active river system for two weeks to simulate environmental samples. These simulated environmental samples were processed using 10% hydrogen peroxide for 24 h to remove organic contamination and then identified using the strongest performing library. We found that libraries with fewer sample spectra produced lower correlation matches and that using derivative correction greatly reduced the number of inaccuracies in identifying materials as either natural or synthetic. We also found that environmental fouling reduced the correlation value of library matches when compared to pristine particles, however the effect was not consistent across the four materials tested. Overall, we found that the accuracy of automated library matching in the tested systems and processing routines varied from 64.1 to 98.0% for distinguishing between natural and synthetic materials, and that a high Hit Quality Index (HQI) did not always correlate with accuracy. These results are important for the microplastic field, demonstrating a need to rigorously test spectral libraries and processing routines with known materials to ensure identification accuracy.

Kozloski, Rachel↗

Development of an ELISA microarray assay for the sensitive and simultaneous detection of ten biodefense toxins.

Plant and microbial toxins are considered bioterrorism threat agents because of their extreme toxicity and/or ease of availability. Additionally, some of these toxins are increasingly responsible for accidental food poisonings. The current study utilized an ELISA-based protein antibody microarray for the multiplexed detection of ten biothreat toxins, botulinum neurotoxins (BoNT) A, B, C, D, E, F, ricin, shiga toxins 1 and 2 (Stx), and staphylococcus enterotoxin B (SEB), in buffer and complex biological matrices. The multiplexed assay displayed a sensitivity of 1.3 pg/mL (BoNT/A, BoNT/B, SEB, Stx-1 and Stx-2), 3.3 pg/mL (BoNT/C, BoNT/E, BoNT/F) and 8.2 pg/mL (BoNT/D, ricin). All assays demonstrated high accuracy (75-120 percent recovery) and reproducibility (most coefficients of variation < 20%). Quantification curves for the ten toxins were also evaluated in clinical samples (serum, plasma, nasal fluid, saliva, stool, and urine) and environmental samples (apple juice, milk and baby food) with overall minimal matrix effects. The multiplex assays were highly specific, with little crossreactivity observed between the selected toxin antibodies. The results demonstrate a multiplex microarray that improves current immunoassay sensitivity for biological warfare agents in buffer, clinical, and environmental samples.

Jenko, Kathryn↗

Predicting Ecological Roles in the Rhizosphere Using Metabolome and Transportome Modeling

The ability to obtain complete genome sequences from bacteria in environmental samples, such as soil samples from the rhizosphere, has highlighted the microbial diversity and complexity of environmental communities. However, new algorithms to analyze genome sequence information in the context of community structure are needed to enhance our understanding of the specific ecological roles of these organisms in soil environments. We present a machine learning approach using sequenced Pseudomonad genomes coupled with outputs of metabolic and transportomic computational models for identifying the most predictive molecular mechanisms indicative of a Pseudomonad's ecological role in the rhizosphere: a biofilm, biocontrol agent, promoter of plant growth, or plant pathogen. Computational predictions of ecological niche were highly accurate overall with models trained on transportomic model output being the most accurate (Leave One Out Validation F-scores between 0.82 and 0.89). The strongest predictive molecular mechanism features for rhizosphere ecological niche overlap with many previously reported analyses of Pseudomonad interactions in the rhizosphere, suggesting that this approach successfully informs a system-scale level understanding of how Pseudomonads sense and interact with their environments. The observation that an organism's transportome is highly predictive of its ecological niche is a novel discovery and may have implications in our understanding microbial ecology. The framework developed here can be generalized to the analysis of any bacteria across a wide range of environments and ecological niches making this approach a powerful tool for providing insights into functional predictions from bacterial genomic data.

59 BASIC BIOLOGICAL SCIENCES↗

Successful application of lead isotopes in source apportionment, legal proceedings, remediation and monitoring

In late 2006, the seaside community in Esperance Western Australia was alerted to thousands of native bird species dying. The source of the lead (Pb) was determined by Pb isotopes to derive from the handling of Pb carbonate concentrate through the Port, which began in July 2005. Concern was expressed for the impact of this on the community. Our objectives were to employ Pb isotope ratios to evaluate the source of Pb in environmental samples for use in legal proceedings, and for use in remediation and monitoring. Isotope measurements were undertaken of bird livers, plants, drinking water, soil, harbour sediments, air, bulk ceiling dust, gutter sludge, surface swabs and blood. The unique lead isotopic signature of the contaminating Pb carbonate enabled diagnostic apportionment of lead in samples. Apart from some soil and water samples, the proportion of contaminating Pb was >95% in the environmental samples. Lead isotopes were critical in resolving legal proceedings, are being used in the remediation of premises, were used in monitoring of workers involved in the decontamination of the storage facility, and monitoring transport of the concentrate through another port facility. Air samples show the continued presence of contaminant Pb, more than one year after shipping of concentrate ceased, probably arising from dust resuspension. Brief details of the comprehensive testing and cleanup of the Esperance community are provided along with the role of the Community. Lead isotopic analyses can provide significant benefits to regulatory agencies, interested parties, and the community where the signature is able to be characterised with a high degree of certainty. - Highlights: Black-Right-Pointing-Triangle Lead carbonate concentrate. Black-Right-Pointing-Triangle Successful use of Pb isotopes in identifying sources of Pb arising from transport and shipping. Black-Right-Pointing-Triangle Use of Pb isotopes in legal proceedings and their use in cleanup of residences. Black-Right-Pointing-Triangle Use of Pb isotopes in cleanup of a residual 9000 tonnes of Pb carbonate and in ongoing monitoring.

54 ENVIRONMENTAL SCIENCES↗

Sample processing approach for detection of ricin in surface samples

With several ricin contamination incidents reported over the past decade, rapid and accurate methods are needed for environmental sample analysis, especially after decontamination. A sample processing method was developed for common surface sampling devices to improve the limit of detection and avoid false negative/positive results for ricin analysis. Potential assay interferents from the sample matrix (bleach residue, sample material, wetting buffer), including reference dust, were tested using a Time-Resolved Fluorescence (TRF) immunoassay. Test results suggested that the sample matrix did not cause the elevated background fluorescence sometimes observed when analyzing post-bleach decontamination samples from ricin incidents. Furthermore, sample particulates (80 mg/mL Arizona Test Dust) did not enhance background fluorescence or interfere with ricin detection by TRF. These results suggested that high background fluorescence in this immunoassay could be due to labeled antibody quality and/or quantity issues. Centrifugal ultrafiltration devices were evaluated for ricin concentration as a part of sample processing. Up to 30-fold concentration of ricin was observed by the devices, which serve to remove soluble interferents and could function as the front-end sample processing step to other ricin analytical methods. Here, the procedure has the potential to be used with a broader range of environmental sample types and with other potential interferences and to be followed by other ricin analytical methods, although additional verification studies would be required.

54 ENVIRONMENTAL SCIENCES↗

Niche and neutral processes both shape community structure in parallelized, aerobic, single carbon-source enrichments

We present DNA sequence data in FASTA-formatted files from aerobic environmental microcosms inoculated with a sole carbon source. DNA sequences are of 16S rRNA genes present in DNA extracted from each microcosm along with the environmental samples (soil, water) used to inoculate them. These samples were sequenced using the Illumina MiSeq platform at the Environmental Sample Preparation and Sequencing Facility at Argonne National Laboratory. This data is compatible with standard microbiome analysis pipelines (e.g., QIIME, mothur, etc.).

Flynn, Theodore M.↗

Sequential chemical separations and multiple ion counting ICP-MS for 241 Pu– 241 Am– 237 Np dating of environmental collections on a single aliquot

In this study, we have developed a combined sequential chemical separation procedure and multiple ion counting ICP-MS measurement method for isotopic measurements of Am in environmental samples. This, in conjunction with established resin bead TIMS measurements for Pu and Np, allows us to measure long-lived Pu–Np–Am nuclides in environmental samples on a single solution aliquot. This single aliquot method reduces time lines and maximizes sample utility for the measurements, improving sensitivity, precision, and accuracy over prior methods. Finally, we have evaluated this new method with environmental reference materials and have obtained accurate results on samples with > 3E6 atoms 241 Am.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Visual Sample Plan Version 7.0 User's Guide

User's guide for VSP 7.0 This user's guide describes Visual Sample Plan (VSP) Version 7.0 and provides instructions for using the software. VSP selects the appropriate number and location of environmental samples to ensure that the results of statistical tests performed to provide input to risk decisions have the required confidence and performance. VSP Version 7.0 provides sample-size equations or algorithms needed by specific statistical tests appropriate for specific environmental sampling objectives. It also provides data quality assessment and statistical analysis functions to support evaluation of the data and determine whether the data support decisions regarding sites suspected of contamination. The easy-to-use program is highly visual and graphic. VSP runs on personal computers with Microsoft Windows operating systems (XP, Vista, Windows 7, and Windows 8). Designed primarily for project managers and users without expertise in statistics, VSP is applicable to two- and three-dimensional populations to be sampled (e.g., rooms and buildings, surface soil, a defined layer of subsurface soil, water bodies, and other similar applications) for studies of environmental quality. VSP is also applicable for designing sampling plans for assessing chem/rad/bio threat and hazard identification within rooms and buildings, and for designing geophysical surveys for unexploded ordnance (UXO) identification.

97 MATHEMATICS AND COMPUTING↗

Development of field-based separations for the rapid identification of uranium and plutonium

The development of rapid, radioanalytical techniques to separate uranium and plutonium from complex, field samples are needed for the timely and accurate determination of nuclear material origin, and processing activities. Widespread use of nuclear power and technology in the world has increased demands on analytical laboratories from the monitoring of numerous low-level, environmental samples with variable compositions. Environmental sampling has proven to be one of the strongest technical measures for detecting nuclear material and activities. With the increase in sampling demands, new technologies must offer improvements such as automation, high throughput, reproducible chemical separations, short analysis times, and reduced costs to be effective. We have been developing a portable, separations system for uranium (U) and plutonium (Pu) separations based upon selective extraction of target elements using an extraction chromatographic resin which would allow for simple and fast identifcation when coupled with the appropriate sample digestor and detection systems. The microfluidic design minimizes elution volumes and concentrates the elements of interest in a purified stream. Flowsheet development and testing was demonstrated on a single, micro-column system with an acidified, iron, uranium, and plutonium nitrate stream. The recovery of Pu was optimized by examining various reducing agents at different concentrations for rapid, quantitative recovery from the flow-through design. Quantitative recovery and high selectivity of U and Pu was achieved in the appropriate stripping stages and provided purified and concentrated U and Pu streams. The microfluidic system suggests automation in a small, footprint unit while exploiting the in-line processing of extraction chromatographic resins as the primary means of concentrating the radionuclides from the raw acidic feed and separating the elements into purified streams.

Extraction Chromatography↗

Transition of Iodine Analysis to Accelerator Mass Spectrometry

This NA 22 funded research project investigated the transition of iodine isotopic analyses from thermal ionization mass spectrometry (TIMS) to an accelerator mass spectrometry (AMS) system. Previous work (Fiscal Year 2010) had demonstrated comparable data from TIMS and AMS. With AMS providing comparable data with improved background levels and vastly superior sample throughput, improvement in the sample extraction from environmental sample matrices was needed to bring sample preparation throughput closer to the operation level of the instrument. Previous research used an extraction chemistry that was not optimized for yield or refined for reduced labor to prove the principle. This research was done to find an extraction with better yield using less labor per sample to produce a sample ready for the AMS instrument.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Los Alamos National Laboratory 2022 Annual Site Environmental Report (Rev. 2)

Los Alamos National Laboratory (Laboratory) annual site environmental reports are prepared each year by the Laboratory’s environmental organizations as required by U.S. Department of Energy Order 231.1B, Administrative Change 1, Environment, Safety, and Health Reporting, and Order 458.1, Administrative Change 4, Radiation Protection of the Public and the Environment. The chapters in this report discuss our compliance with environmental laws, regulations, and orders (Chapter 2, Compliance Summary); how we manage the Laboratory’s environmental performance and assure the quality of data from analysis of environmental samples (Chapter 3, Environmental Programs and Analytical Data Quality); how we monitor for air emissions of radioactive materials and for weather conditions (Chapter 4, Air Quality); how we monitor for effects of Laboratory operations on groundwater quality (Chapter 5, Groundwater Protection); how we monitor the levels of chemicals and radionuclides in storm water runoff and sediment (Chapter 6, Watershed Quality); how we monitor for the levels and effects of chemicals and radionuclides in plants, animals, soil, and vegetation (Chapter 7, Ecosystem Health); and finally, what radioactive dose or risk from chemical exposure that members of the public could experience as a result of Laboratory operations (Chapter 8, Public Dose and Risk Assessment).

54 ENVIRONMENTAL SCIENCES↗

New Developments in LC-MS and Other Hyphenated Techniques

Extensive challenges faced by analytical chemists in studying real world complex samples such as biological body fluids, tissue samples, environmental and geological samples have lead to the development of advanced analytical approaches. The vast array of contemporary technologies can be categorized into two major areas: sample separation and mass spectrometry analysis. Current state-of-the-art sample separation methods include gas chromatography, high performance liquid chromatography, ultra high pressure liquid chromatography, solid phase extraction, capillary electrophoresis, and gas phase separation techniques such as ion mobility spectrometry. The recent trend in sample separation is to combine (or hyphenate) multiple techniques that employ different separation mechanisms to maximize separation efficiency. The most widely used combinations include two-dimensional gas chromatography, strong cation exchange or weak cation exchange chromatography followed by reversed-phase liquid chromatography, two-dimensional reversed-phase liquid chromatography, liquid chromatography followed by ion mobility spectrometry and two-dimensional electrophoresis techniques. The introduction of atmospheric pressure ionization techniques such as electrospray ionization and matrix assisted laser desorption ionization and variations of the two have drastically increased the impact of mass spectrometry on bioanalytical applications. Mass spectrometry itself has tremendously improved over the years in terms of sensitivity, detection limits, dynamic range and sequencing capabilities. Currently, mass spectrometers can attain zeptomolole detection limits with five orders of magnitude dynamic range. In this chapter, we summarize recent developments in hyphenated techniques and their applications to complex sample analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

R&D Outcomes of Surrogate Environmental Swipe Manufacturing Technique Method Development for Arms Control and Treaty Verification Applications

The analysis of environmental samples is a critical component of nuclear compliance verification and safeguards activities. While the associated particle analyses have benefitted from recent advances in the production of actinide-bearing particulates with uniform and well-characterized particle size, material phase, and isotopic ratios to serve as reference materials for calibration and interlaboratory comparisons, there is an outstanding need for surrogate environmental samples, which resemble field-collected samples, with the aforementioned reference particulates to support future nuclear compliance verification exercises and method development. This effort seeks to leverage the recent advances in tailored reference particle production to generate surrogate environmental swipe samples via parallel production techniques (direct and indirect) which are uniquely suited to the hydrothermal and aerosol-based synthesis routes developed at PNNL and SRNL, respectively. PNNL’s hydrothermal particle production method was used to generate surrogate reference particles for the indirect production of test swipes.

54 ENVIRONMENTAL SCIENCES↗

Plutonium Isotopes in the Terrestrial Environment at the Savannah River Site, USA. A Long-Term Study

This work presents the findings of a long term plutonium study at Savannah River Site (SRS) conducted between 2003 and 2013. Terrestrial environmental samples were obtained at Savannah River National Laboratory (SRNL) in A-area. Plutonium content and isotopic abundances were measured over this time period by alpha spectrometry and three stage thermal ionization mass spectrometry (3STIMS). Here we detail the complete sample collection, radiochemical separation, and measurement procedure specifically targeted to trace plutonium in bulk environmental samples. Total plutonium activities were determined to be not significantly above atmospheric global fallout. However, the 238 Pu/ 239+240 Pu activity ratios attributed to SRS are above atmospheric global fallout ranges. The 240 Pu/ 239 Pu atom ratios are reasonably consistent from year to year and are lower than fallout, while the 242 Pu/ 239 Pu atom ratios are higher than fallout values. Overall, the plutonium signatures obtained in this study reflect a mixture of weapons-grade, higher burn-up, and fallout material. This study provides a blue print for long term low level monitoring of plutonium in the environment.

54 ENVIRONMENTAL SCIENCES↗

Microbial Characterization and Comparison of Isolates During the Mir and ISS Missions

Spacecraft represent a semi-closed ecosystem that provides a unique model of microbial interaction with other microbes, potential hosts, and their environment. Environmental samples from the Mir Space Station (1995-1998) and the International Space Station (ISS) (2000-Present) were collected and processed to provide insight into the characterization of microbial diversity aboard spacecraft over time and assess any potential health risks to the crew. All microbiota were isolated using standard media-based methodologies. Isolates from Mir and ISS were processed using various methods of analysis, including VITEK biochemical analysis, 16s ribosomal identification, and fingerprinting using rep-PCR analysis. Over the first 41 months of habitation, the diversity of the microbiota from air and surface samples aboard ISS increased from an initial six to 53 different bacterial species. During the same period, fungal diversity increased from 2 to 24 species. Based upon rep-PCR analysis, the majority of isolates were unique suggesting the need for increased sampling frequency and a more thorough analysis of samples to properly characterize the ISS microbiota. This limited fungal and bacterial data from environmental samples acquired during monitoring currently do not indicate a microbial hazard to ISS or any trends suggesting potential health risks.