Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Transmission of Images With Ultrasonic Elastic Shear Waves on a Metallic Pipe Using Amplitude Shift Keying Protocol

Transmission of information using ultrasonic elastic waves on existing metallic pipes provides an alternative communication option across physical barriers in a highly partitioned industrial complex, such as a nuclear facility. This work investigates the feasibility of the transmission of digital images over metallic pipes. Ultrasonic communication systems for transmission of images on a nuclear-grade stainless steel pipe were assembled for bench-scale demonstration. Information carriers in this system are refracted shear waves transmitted and received with piezoelectric transducers (PZTs) operating at 2-MHz nominal frequency. The refraction and propagation of ultrasonic shear waves were modeled with COMSOL software. An amplitude shift keying (ASK) communication protocol for image transmission was developed and implemented in the GNURadio software-defined radio (SDR) environment. Digital information was converted to analog ultrasonic signals using Red Pitaya electronic boards. The performance of the ASK protocol is evaluated at the output of every block in the GNURadio program by monitoring the transmission of select characters. Using the ASK communication protocol, the transmission of the 32-KB image was demonstrated at 2-Kbps bitrate across 6-ft-long stainless steel pipe. Finally, preliminary evaluation of ultrasonic communication on the piping of a nuclear facility, such as signal transmission on bent pipes, was performed with COMSOL computer simulations.

42 ENGINEERING↗

Practical State Machine Replication with Confidentiality

We study how to enable arbitrary randomized algorithms in Byzantine fault-tolerant (BFT) settings. We formalize a randomized BFT protocol and provide a simple and efficient construction that can be built on any existing BFT protocols while adding practically no overhead. We go one step further to revisit a confidential BFT protocol (Yin et al., SOSP '03). We show that their scheme is potentially susceptible to safety and confidentiality attacks. We then present a new protocol that is secure in the stronger model we formalize, by extending the idea of a randomized BFT protocol. Our protocol uses only efficient symmetric cryptography, while Yin et al.'s uses costly threshold signatures. We implemented and evaluated our protocols on microbenchmarks and real-world use cases. We show that our randomized BFT protocol is as efficient as conventional BFT protocols, and our confidential BFT protocol is two to three orders of magnitude faster than Yin et al.'s, which is less secure than ours.

Duan, Sisi↗

Byzantine Reliable Broadcast in Sparse Networks

Modern large-scale networks require the ability to withstand arbitrary failures (i.e., Byzantine failures). Byzantine reliable broadcast algorithms can be used to reliably disseminate information in the presence of Byzantine failures. We design a novel Byzantine reliable broadcast protocol for loosely connected and synchronous networks. While previous such protocols all assume correct senders, our protocol is the first to handle Byzantine senders. To achieve this goal, we have developed new techniques for fault detection and fault tolerance. Our protocol is efficient, and under normal circumstances, no expensive public-key cryptographic operations are used. We implement and evaluate our protocol, demonstrating that our protocol has high throughput and is superior to the existing protocols in uncivil executions.

Byzantine broadcast↗

PRIME: An evaluation framework for protein representation inference and generalization in viral mutation space

Background Protein language models (PLMs) have revolutionized protein fitness prediction, yet their application to rapidly evolving viral pathogens is often confounded by extreme sequence homology. This homology leads to “data leakage” in standard random validation splits, yielding inflated performance metrics that fail to translate into real-world biosurveillance utility. Results We present Protein Representation Inference for Mutation Evaluation (PRIME), a framework that integrates domain-specific fine-tuning with a rigorous position-stratified validation protocol to evaluate viral threats. Using a dataset of 347,432 SARS-CoV-2 receptor binding domain (RBD) sequences, we demonstrate that while random training data split yields deceptive R 2 values (> 0.90), they fail to generalize to novel mutational sites. By benchmarking models up to 650 M parameters, we show that domain-specific fine-tuning of the ESM-C 600 M model with correctly stratified data provides an initial demonstration of predictive signal for binding affinity and expression at unseen mutational sites of binding affinity and expression on unseen sites (R 2 ~0.23), a significant advancement over base foundation models which exhibit no predictive power (R 2 <0). PRIME’s embedding-based clustering identified 3.03% of bat coronavirus sequences as candidates for further experimental prioritization based on their functional similarity to human-infective strains in embedding space, offering a perspective complementary to traditional phylogenetic methods. Conclusion PRIME establishes a new benchmark for the application of PLMs in pathogen surveillance. Our findings demonstrate that state-of-the-art models and fine-tuning, when paired with stratified validation, provide biologically meaningful insights into pathogen evolution and zoonotic risk.

59 BASIC BIOLOGICAL SCIENCES↗

SU-F-J-16: Planar KV Imaging Dose Reduction Study

Purpose: IGRT has become an indispensable tool in modern radiotherapy with kV imaging used in many departments due to superior image quality and lower dose when compared to MV imaging. Many departments use manufacturer supplied protocols for imaging which are not always optimised between image quality and radiation dose (ALARA). Methods: Whole body phantom PBU-50 (Kyoto Kagaku ltd., Japan) for imaging in radiology has been imaged on Varian iX accelerator (Varian Medical Systems, USA) with OBI 1.5 system. Manufacturer’s default protocols were adapted by modifying kV and mAs values when imaging different anatomical regions of the phantom (head, thorax, abdomen, pelvis, extremities). Images with different settings were independently reviewed by two persons and their suitability for IGRT set-up correction protocols were evaluated. The suitable images with the lowest mAs were then selected. The entrance surface dose (ESD) for manufacturer’s default protocols and modified protocols were measured with RTI Black Piranha (RTI Group, Sweden) and compared. Image quality was also measured with kVQC phantom (Standard Imaging, USA) for different protocols. The modified protocols have been applied for clinical work. Results: For most cases optimized protocols reduced the ESD on average by a factor of 3(range 0.9–8.5). Further reduction in ESD has been observed by applying bow-tie filter designed for CBCT. The largest reduction in dose (12.2 times) was observed for Thorax lateral protocol. The dose was slightly increased (by 10%) for large pelvis AP protocol. Conclusion: Manufacturer’s default IGRT protocols could be optimised to reduce the ESD to the patient without losing the necessary image quality for patient set-up correction. For patient set-up with planar kV imaging the bony anatomy is mostly used and optimization should focus on this aspect. Therefore, the current approach with anthropomorphic phantom is more advantageous in optimization over standard kV quality control phantoms and SNR metrics.

60 APPLIED LIFE SCIENCES↗

A systematic strategy for estimating hERG block potency and its implications in a new cardiac safety paradigm

Introduction: hERG block potency is widely used to calculate a drug's safety margin against its torsadogenic potential. Previous studies are confounded by use of different patch clamp electrophysiology protocols and a lack of statistical quantification of experimental variability. Since the new cardiac safety paradigm being discussed by the International Council for Harmonisation promotes a tighter integration of nonclinical and clinical data for torsadogenic risk assessment, a more systematic approach to estimate the hERG block potency and safety margin is needed. Methods: A cross-industry study was performed to collect hERG data on 28 drugs with known torsadogenic risk using a standardized experimental protocol. A Bayesian hierarchical modeling (BHM) approach was used to assess the hERG block potency of these drugs by quantifying both the inter-site and intra-site variability. A modeling and simulation study was also done to evaluate protocol-dependent changes in hERG potency estimates. Results: A systematic approach to estimate hERG block potency is established. The impact of choosing a safety margin threshold on torsadogenic risk evaluation is explored based on the posterior distributions of hERG potency estimated by this method. The modeling and simulation results suggest any potency estimate is specific to the protocol used. Discussion: This methodology can estimate hERG block potency specific to a given voltage protocol. The relationship between safety margin thresholds and torsadogenic risk predictivity suggests the threshold should be tailored to each specific context of use, and safety margin evaluation may need to be integrated with other information to form a more comprehensive risk assessment.

60 APPLIED LIFE SCIENCES↗

Evaluation of Final Radiological Conditions at Areas of the Niagara Falls Storage Site Remediated under the Formerly Utilized Sites Remedial Action Program - 12184

The U.S. Department of Energy (DOE) methods and protocols allow evaluation of remediation and final site conditions to determine if remediated sites remain protective. Two case studies are presented that involve the Niagara Falls Storage Site (NFSS) and associated vicinity properties (VPs), which are being remediated under the Formerly Utilized Sites Remedial Action Program (FUSRAP). These properties are a part of the former Lake Ontario Ordnance Works (LOOW). In response to stakeholders concerns about whether certain remediated NFSS VPs were putting them at risk, DOE met with stakeholders and agreed to evaluate protectiveness. Documentation in the DOE records collection adequately described assessed and final radiological conditions at the completed VPs. All FUSRAP wastes at the completed sites were cleaned up to meet DOE guidelines for unrestricted use. DOE compiled the results of the investigation in a report that was released for public comment. In conducting the review of site conditions, DOE found that stakeholders were also concerned about waste from the Separations Process Research Unit (SPRU) at the Knolls Atomic Power Laboratory (KAPL) that was handled at LOOW. DOE agreed to determine if SPRU waste remained at that needed to be remediated. DOE reviewed records of waste characterization, historical handling locations and methods, and assessment and remediation data. DOE concluded that the SPRU waste was remediated on the LOOW to levels that pose no unacceptable risk and allow unrestricted use and unlimited exposure. This work confirms the following points as tenets of an effective long-term surveillance and maintenance (LTS and M) program: - Stakeholder interaction must be open and transparent, and DOE must respond promptly to stakeholder concerns. - DOE, as the long-term custodian, must collect and preserve site records in order to demonstrate that remediated sites pose no unacceptable risk. - DOE must continue to maintain constructive relationships with the U.S. Army Corps of Engineers and state and federal regulators. After review of historical site documentation, DOE reports, and USACE radiological data, DOE concluded the following: - DOE had access to adequate documentation to evaluate site conditions at the former LOOW. This is important to confirm now, while institutional knowledge of early FUSRAP work remains available. - DOE remediated the completed VPs to conditions that are protective for unrestricted residential use. Sample and walkover gamma scan results indicate that no wastes remain that exceed cleanup criteria. - Process knowledge and field observations establish that Cs-137 is the predominant radionuclide in the KAPL waste stream. Cs-137, a strong gamma emitter, was used as an indicator for remediation of KAPL waste. Other radionuclides were present in much lower relative concentrations and were likely also removed during remediation of the VPs. - KAPL contaminants were removed during remedial activities at the former LOOW as either co-located or co-mingled with other radionuclides. - For the active VPs (VP-E, VP-E', and VP-G), results of DOE's cleanup of the accessible portions of these properties indicate that KAPL waste does not remain at concentrations greater than the DOE cleanup limit: - Inaccessible areas were not associated with historic KAPL waste handling. Therefore, it is unlikely that KAPL waste remains on the active VPs. - Because gamma activity was used by DOE during remediation/verification activities for excavation control, additional USACE cleanup of FUSRAP wastes on these properties will likely result in the remediation of any co-located residual KAPL wastes to acceptable levels or identification of KAPL waste that is not co-located. - Although USACE has not established a cleanup level for Cs-137 on the active NFSS VPs, DOE assessment and remediation data indicate that assessed Cs-137 was remediated and significant Cs-137 is unlikely to remain. Because of the low likelihood of encountering significant KAPL waste on the active NFSS VPs, additional remediation is not anticipated at these properties. - USACE assessment soil sampling results on the NFSS proper indicate that KAPL waste does not exceed the DOE cleanup level for Cs-137. USACE has not established a cleanup level for Cs-137 on NFSS proper. The USACE cleanup of FUSRAP wastes on the NFSS proper will likely result in the remediation of any co-located residual KAPL wastes or identification of KAPL waste that is not co-located. DOE is drafting a report of the investigation of KAPL waste at LOOW. The report will be released to the public for comment when the draft is complete. DOE responses to stakeholder inquiries resulted in a common understanding of site conditions and site risk. DOE expects additional interaction with stakeholders at the former LOOW as USACE completes remediation of the active VPs and the NFSS proper, and these relationships will hopefully have built trust between DOE and the stakeholders that DOE will perform its duties in an open and transparent manner that includes stakeholders as stewards for remediated FUSRAP sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Final Radiological Conditions at Areas of the Niagara Falls Storage Site Remediated under the Formerly Utilized Sites Remedial Action Program -12184

The U. S. Department of Energy (DOE) methods and protocols allow evaluation of remediation and final site conditions to determine if remediated sites remain protective. Two case studies are presented that involve the Niagara Falls Storage Site (NFSS) and associated vicinity properties (VPs), which are being remediated under the Formerly Utilized Sites Remedial Action Program (FUSRAP). These properties are a part of the former Lake Ontario Ordnance Works (LOOW). In response to stakeholders concerns about whether certain remediated NFSS VPs were putting them at risk, DOE met with stakeholders and agreed to evaluate protectiveness. Documentation in the DOE records collection adequately described assessed and final radiological conditions at the completed VPs. All FUSRAP wastes at the completed sites were cleaned up to meet DOE guidelines for unrestricted use. DOE compiled the results of the investigation in a report that was released for public comment. In conducting the review of site conditions, DOE found that stakeholders were also concerned about waste from the Separations Process Research Unit (SPRU) at the Knolls Atomic Power Laboratory (KAPL) that was handled at LOOW. DOE agreed to determine if SPRU waste remained at that needed to be remediated. DOE reviewed records of waste characterization, historical handling locations and methods, and assessment and remediation data. DOE concluded that the SPRU waste was remediated on the LOOW to levels that pose no unacceptable risk and allow unrestricted use and unlimited exposure. This work confirms the following points as tenets of an effective long-term surveillance and maintenance (LTS&M) program: Stakeholder interaction must be open and transparent, and DOE must respond promptly to stakeholder concerns. DOE, as the long-term custodian, must collect and preserve site records in order to demonstrate that remediated sites pose no unacceptable risk. DOE must continue to maintain constructive relationships with the U.S. Army Corps of Engineers and state and federal regulators.

Remediation, Niagara Falls Storage Site, Lake Onta↗

Developing rapid electrochemical relithiation protocols for scalable relithiation of lithium-ion battery cathode materials

The recent and ongoing boom in electric vehicle sales has caused the circularity of the supply chain for electric vehicle battery materials to come under a great deal of scrutiny. Innovative recycling processes, or direct recycling, that offer the possibility of reducing the cost of recycling are one possible solution to regaining resources from end-of-life (EoL) electric vehicle batteries. Electrochemically shuttling lithium back into the cathode, or electrochemical relithiation, is a possible technique for restoring lithium content to NMC materials (EoL) in a direct recycling process. This study provides essential understanding towards developing an electrochemical relithiation protocol that will restore lithium loss in intercalation cathode materials that reach EoL by loss of lithium inventory (LLI) as opposed to other degradation mechanisms like loss of active material (LAM), cation mixing or phase transition. Electrochemically aged NMC cathode materials have been prepared and characterized to establish the extent of EoL material structural degradation and lithium loss. A model-informed experimental process is used to identify the optimal electrochemical relithiation protocol to minimize the time taken to relithiate EoL materials and maximize the amount of lithium restored. Protocols were evaluated based on their ability to enable rapid lithium intercalation, maintain structural uniformity in the EoL material and fully restore lithium content. An optimal protocol was identified at elevated temperatures utilizing a novel scanning voltage step.

25 ENERGY STORAGE↗

An Approach for Performance Based Glove Mobility Requirements

The Space Suit Assembly (SSA) Development Team at NASA Johnson Space Center has invested heavily in the advancement of rear‐entry planetary exploration suit design but largely deferred development of extravehicular activity (EVA) glove designs, and accepted the risk of using the current flight gloves, Phase VI, for exploration missions. However, as design reference missions mature, the risks of using heritage hardware have highlighted the need for developing robust new glove technologies. To address the technology gap, the NASA Space Technology Mission Directorate's Game‐Changing Development Program provided start‐up funding for the High Performance EVA Glove (HPEG) Element as part of the Next Generation Life Support (NGLS) Project in the fall of 2013. The overarching goal of the HPEG Element is to develop a robust glove design that increases human performance during EVA and creates pathway for implementation of emergent technologies, with specific aims of increasing pressurized mobility to 60% of barehanded capability, increasing the durability in on‐pristine environments, and decreasing the potential of gloves to cause injury during use. The HPEG Element focused initial efforts on developing quantifiable and repeatable methodologies for assessing glove performance with respect to mobility, injury potential, thermal conductivity, and abrasion resistance. The team used these methodologies to establish requirements against which emerging technologies and glove designs can be assessed at both the component and assembly levels. The mobility performance testing methodology was an early focus for the HPEG team as it stems from collaborations between the SSA Development team and the JSC Anthropometry and Biomechanics Facility (ABF) that began investigating new methods for suited mobility and fit early in the Constellation Program. The combined HPEG and ABF team used lessons learned from the previous efforts as well as additional reviews of methodologies in physical and occupational therapy arenas to develop a protocol that assesses gloved range of motion, strength, dexterity, tactility, and fit in comparative quantitative terms and also provides qualitative insight to direct hardware design iterations. The protocol was evaluated using five experienced test subjects wearing the EMU pressurized to 4.3psid with three different glove configurations. The results of the testing are presented to illustrate where the protocol is and is not valid for benchmark comparisons. The process for requirements development based upon the results is also presented along with suggested performance values for the High Performance EVA Gloves to be procured in fiscal year 2015.

Aitchison, Lindsay↗

An Approach for Performance Based Glove Mobility Requirements

The Space Suit Assembly (SSA) Development Team at NASA Johnson Space Center has invested heavily in the advancement of rear-entry planetary exploration suit design but largely deferred development of extravehicular activity (EVA) glove designs, and accepted the risk of using the current flight gloves, Phase VI, for exploration missions. However, as design reference missions mature, the risks of using heritage hardware have highlighted the need for developing robust new glove technologies. To address the technology gap, the NASA Space Technology Mission Directorate's Game-Changing Development Program provided start-up funding for the High Performance EVA Glove (HPEG) Element as part of the Next Generation Life Support (NGLS) Project in the fall of 2013. The overarching goal of the HPEG Element is to develop a robust glove design that increases human performance during EVA and creates pathway for implementation of emergent technologies, with specific aims of increasing pressurized mobility to 60% of barehanded capability, increasing the durability in on-pristine environments, and decreasing the potential of gloves to cause injury during use. The HPEG Element focused initial efforts on developing quantifiable and repeatable methodologies for assessing glove performance with respect to mobility, injury potential, thermal conductivity, and abrasion resistance. The team used these methodologies to establish requirements against which emerging technologies and glove designs can be assessed at both the component and assembly levels. The mobility performance testing methodology was an early focus for the HPEG team as it stems from collaborations between the SSA Development team and the JSC Anthropometry and Biomechanics Facility (ABF) that began investigating new methods for suited mobility and fit early in the Constellation Program. The combined HPEG and ABF team used lessons learned from the previous efforts as well as additional reviews of methodologies in physical and occupational therapy arenas to develop a protocol that assesses gloved range of motion, strength, dexterity, tactility, and fit in comparative quantitative terms and also provides qualitative insight to direct hardware design iterations. The protocol was evaluated using five experienced test subjects wearing the EMU pressurized to 4.3psid with three different glove configurations. The results of the testing are presented to illustrate where the protocol is and is not valid for benchmark comparisons. The process for requirements development based upon the results is also presented along with suggested performance values for the High Performance EVA Gloves currently in development.

Aitchison, Lindsay↗

Experimental evaluation of multiprocessor cache-based error recovery

Several variations of cache-based checkpointing for rollback error recovery in shared-memory multiprocessors have been recently developed. By modifying the cache replacement policy, these techniques use the inherent redundancy in the memory hierarchy to periodically checkpoint the computation state. Three schemes, different in the manner in which they avoid rollback propagation, are evaluated. By simulation with address traces from parallel applications running on an Encore Multimax shared-memory multiprocessor, the performance effect of integrating the recovery schemes in the cache coherence protocol are evaluated. The results indicate that the cache-based schemes can provide checkpointing capability with low performance overhead but uncontrollable high variability in the checkpoint interval.

Janssens, Bob↗

Modulation of Bone Marrow Primary Cell Osteoblastogenesis and Cell Senescence by Mechanical Stimulation

Cell and animal studies conducted onboard the International Space Station and formerly the Shuttle flights have provided groundbreaking data illuminating the deleterious biological response of bone to mechanical unloading. Specifically CDKN1A/p-21 a cell senescence protein, was found to be upregulated in osteoprecursor cells of the femur during 15-day spaceflight, leading to the working hypothesis that CDKN1A/p-21 plays a role in inhibition of bone formation via mechanical regulation. To evaluate this hypothesis, utilizing a p-21 knockout mouse-line and relevant wildtype control, we cultured femoral bone marrow primary cells under unloaded (static) and cyclically stretched loading through a 30 day osteoblastogenesis protocol. Morphologic evaluation of the cultures demonstrated that mechanical stretching aligned the cells and increased the presence of defined focal adhesion expressing talin, integrin αvβ3, and PTK2 protein tyrosine kinase 2, also known as focal adhesion kinase (FAK) in both mouse strains. In corroboration with previous investigations of cell survival signals relation to FAK, our study found that with greater concentration of focal adhesions via stretch stimulation the live cell percentage was significantly higher than the unloaded controls (p-21 knockout line: +49.70%, p*=0.009, wildtype control: +18.14%, p*=.01). Also evaluated was the mineralization and ECM secretion capability of the differentiating cells. Von Kossa staining has shown that in the p-21 knockout cells unloaded cells produce more matrix that the stretch stimulated, however the matrix is unorganized presenting in sporadic nodules covering approximately 30% of the culture area at day 14 (n=6 wells) while the stretch stimulated cultures have less mineralization content the surface area containing mineralized matrix is greater (~68% at day 14). Q-PCR evaluation of the p-21 knockout cells revealed that canonical (β-catenin cascade) and non-canonical wnt11 and downstream planar cell polarity (wnt/PCP) pathway molecule RAC1 are prevalently upregulated with mechanical stimulation. Immunofluorescence for β-catenin and RAC1 showed co-localization at the nuclear membrane of the p-21 knockout cells but not the wildtype (n=1) suggesting that molecular communication via the canonical and wnt/PCP pathway are initiated by mechanical loading and experience regulation along the signaling cascade by CDKN1A/p-21. Future investigations will further elucidate this relationship and provide causal data demonstrating mechanical loading’s modulatory effect on p-21 expression change.

Juran, Cassandra M.↗

CAPTIONALS: A computer aided testing environment for the verification and validation of communication protocols

This paper covers the verification and protocol validation for distributed computer and communication systems using a computer aided testing approach. Validation and verification make up the so-called process of conformance testing. Protocol applications which pass conformance testing are then checked to see whether they can operate together. This is referred to as interoperability testing. A new comprehensive approach to protocol testing is presented which address: (1) modeling for inter-layer representation for compatibility between conformance and interoperability testing; (2) computational improvement to current testing methods by using the proposed model inclusive of formulation of new qualitative and quantitative measures and time-dependent behavior; (3) analysis and evaluation of protocol behavior for interactive testing without extensive simulation.

Feng, C.↗

Harnessing land-atmosphere interactions to enhance subseasonal-to-seasonal predictability

2025 Advancing Understanding of Land-Atmosphere Interactions and Processes on S2S Predictability Workshop What: 227 registered workshop participants gathered in person (43%) and online (57%) to discuss state-of-the-art scientific understanding and modeling of land-atmosphere interactions and related processes in the context of subseasonal-to-seasonal (S2S) predictability. Topics covered sources of S2S predictability, land model initialization methods, model diagnosis and evaluation metrics, AI/ML analysis and applications, and coordination of future community multi-model S2S forecast focused experiments. To advance the science, this community workshop, organized by NSF NCAR, NOAA, NASA, and DOE, aimed to 1) identify process- and application-oriented metrics for assessing S2S prediction skill and 2) develop experimental protocols for coordinated experiments to isolate, quantify, and understand the role of land-atmosphere interactions in S2S predictability. When: June 16-18, 2025 Where: Boulder, CO, USA, and online.

Land-Atmosphere Interaction↗

Field Monitoring Protocol: Heat Pump Water Heaters

This document provides a standard field monitoring protocol for evaluating the installed performance of Heat Pump Water Heaters in residential buildings. The report is organized to be consistent with the chronology of field test planning and execution. Research questions are identified first, followed by a discussion of analysis methods, and then the details of measuring the required information are laid out. A field validation of the protocol at a house near the NREL campus is included for reference.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Monitoring Protocol. Heat Pump Water Heaters

This document provides a standard field monitoring protocol for evaluating the installed performance of Heat Pump Water Heaters in residential buildings. The report is organized to be consistent with the chronology of field test planning and execution. Research questions are identified first, followed by a discussion of analysis methods, and then the details of measuring the required information are laid out. A field validation of the protocol at a house near the NREL campus is included for reference.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Systematic Review of Protocols for the Three-Dimensional Morphologic Assessment of Abdominal Aortic Aneurysms Using Computed Tomographic Angiography

The morphology of infrarenal abdominal aortic aneurysms (AAAs) directly influences the perioperative outcome and long-term durability of endovascular aneurysm repair. A variety of methods have been proposed for the characterization of AAA morphology using reconstructed three-dimensional (3D) computed tomography (CT) images. At present, there is lack of consensus as to which of these methods is most applicable to clinical practice or research. The purpose of this review was to evaluate existing protocols that used 3D CT images in the assessment of various aspects of AAA morphology. An electronic search was performed, from January 1996 to the end of October 2010, using the Embase and Medline databases. The literature review conformed to PRISMA statement standards. The literature search identified 604 articles, of which 31 studies met inclusion criteria. Only 15 of 31 studies objectively assessed reproducibility. Existing published protocols were insufficient to define a single evidence-based methodology for preoperative assessment of AAA morphology. Further development and expert consensus are required to establish a standardized and validated protocol to determine precisely how morphology relates to outcomes after endovascular aneurysm repair.

62 RADIOLOGY AND NUCLEAR MEDICINE↗