Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Optimal measurement strategies for effective suppression of drift errors

Drifting of experimental setups with change in temperature or other environmental conditions is the limiting factor of many, if not all, precision measurements. The measurement error due to a drift is, in some sense, in-between random noise and systematic error. In the general case, the error contribution of a drift cannot be averaged out using a number of measurements identically carried out over a reasonable time. In contrast to systematic errors, drifts are usually not stable enough for a precise calibration. Here a rather general method for effective suppression of the spurious effects caused by slow drifts in a large variety of instruments and experimental setups is described. An analytical derivation of an identity, describing the optimal measurement strategies suitable for suppressing the contribution of a slow drift described with a certain order polynomial function, is presented. A recursion rule as well as a general mathematical proof of the identity is given. The effectiveness of the discussed method is illustrated with an application of the derived optimal scanning strategies to precise surface slope measurements with a surface profiler.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Harnessing the power of an X-ray laser for serial crystallography of membrane proteins crystallized in lipidic cubic phase

Serial femtosecond crystallography (SFX) with X-ray free-electron lasers (XFELs) has proven highly successful for structure determination of challenging membrane proteins crystallized in lipidic cubic phase; however, like most techniques, it has limitations. Here we attempt to address some of these limitations related to the use of a vacuum chamber and the need for attenuation of the XFEL beam, in order to further improve the efficiency of this method. Using an optimized SFX experimental setup in a helium atmosphere, the room-temperature structure of the adenosine A 2A receptor (A 2A AR) at 2.0 Å resolution is determined and compared with previous A 2A AR structures determined in vacuum and/or at cryogenic temperatures. Specifically, the capability of utilizing high XFEL beam transmissions is demonstrated, in conjunction with a high dynamic range detector, to collect high-resolution SFX data while reducing crystalline material consumption and shortening the collection time required for a complete dataset. The experimental setup presented herein can be applied to future SFX applications for protein nanocrystal samples to aid in structure-based discovery efforts of therapeutic targets that are difficult to crystallize.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

VAPOR PRESSURE ISOTOPE EFFECTS IN THE MEASUREMENT OF ENVIRONMENTAL TRITIUM SAMPLES.

Standard procedures for the measurement of tritium in water samples often require distillation of an appropriate sample aliquot. This distillation process may result in a fractionation of tritiated water and regular light water due to the vapor pressure isotope effect, introducing either a bias or an additional contribution to the total tritium measurement uncertainty. The magnitude of the vapor pressure isotope effect is characterized as functions of the amount of water distilled from the sample aliquot and the heat settings for the distillation process. The tritium concentration in the distillate is higher than the tritium concentration in the sample early in the distillation process, it then sharply decreases due to the vapor pressure isotope effect and becomes lower than the tritium concentration in the sample, until the high tritium concentration retained in the boiling flask is evaporated at the end of the process. At that time, the tritium concentration in the distillate again overestimates the sample tritium concentration. The vapor pressure isotope effect is more pronounced the slower the evaporation and distillation process is conducted; a lower heat setting during the evaporation of the sample results in a larger bias in the tritium measurement. The experimental setup used and the fact that the current study allowed for an investigation of the relative change in vapor pressure isotope effect in the course of the distillation process distinguish it from and extend previously published measurements. The separation factor as a quantitative measure of the vapor pressure isotope effect is found to assume values of 1.034 {+-} 0.033, 1.052 {+-} 0.025, and 1.066 {+-} 0.037, depending on the vigor of the boiling process during distillation of the sample. A lower heat setting in the experimental setup, and therefore a less vigorous boiling process, results in a larger value for the separation factor. For a tritium measurement in water samples, this implies that the tritium concentration could be underestimated by 3 - 6%.

54 ENVIRONMENTAL SCIENCES↗

Deposition Mitigation in Flowing Systems Using Coatings

Abstract In pipelines, solid compounds including gas hydrates and asphaltenes may form/precipitate and accumulate on the pipe surface, leading to a gradual stenosis of the flowline. As a result, production may become increasingly difficult or possibly interrupted if mitigation efforts are not enacted. Typically, injected chemicals will either inhibit nucleation or dissolve already-formed deposits to restore original flow conditions back to the system; however, this can be a costly option. More recently, management strategies have been proposed where solids are handled in a controlled fashion rather than completely avoided. One such proposed management strategy as suggested for wall deposit formation is the use of coatings. Here, coatings can provide a low surface energy layer on the pipe wall, which restricts liquid and solid accumulation, allowing for a stable slurry flow through a system. This study utilized two material formulations within several experimental setups to probe their interactions with water, gas hydrate, asphaltene, and crude oil. The results serve as part of an ongoing investigation into a surface treatment formulation that can be tested on larger-scale, fully flowing systems, which could be ultimately implemented into real-world production scenarios. The first surface treatment is a water-based polymeric surface that displays repellency to both oil and water phases (omniphobic). Testing of this material consisted of water contact angle measurements and static asphaltene/crude oil deposition quantification at atmospheric conditions, as well as visual confirmation of hydrate deposition prevention at high pressures. Additionally, an experimental superomniphobic surface treatment, which displays elevated resiliency to both water and hydrocarbons, was also examined within the asphaltene/crude oil test as a comparison to the omniphobic surface treatment. Static contact angle results showed that the omniphobic surface treatment had reduced surface interaction with water droplets in air, increasing the low contact angles of corroded surfaces (0-31°) to slightly hydrophobic conditions of 91.5°. Additionally, rocking cells tests indicated that these omniphobic surface treatments may prevent gas hydrate deposition under high-pressure, semi-flowing conditions. Multiple tests found that formed hydrate agglomerants did not deposit for at least 48 and 72 hours. Finally, static deposition tests conducted in crude oil with forced asphaltene precipitation suggested that the omniphobic surface treatment displayed a resistance to both asphaltenes and crude oil when compared to untreated and superomniphobic surfaces.

03 NATURAL GAS↗

Advance optical fiber probe for simultaneous measurements of solids holdup and particles velocity using simple calibration methods for gas-solid fluidization systems

We report advanced gas-solid optical fiber probe technique that can measure simultaneously solids velocity, solids concentration related quantity, and their time series fluctuations has been implemented with simple and new calibration methods for both solids holdup and particles velocity measurements in gas-solid spouted bed and gas-solid fluidized bed. The needed signal and data processing programs have been developed in our laboratory. New, simple, and reliable calibration methods and the related experimental setups have been established to convert the solids concentration related signal to solids holdup which is a meaningful hydrodynamic parameter and to determine the effective distance between the two tips of the probe for the solids velocity measurements. The new calibration methods have been employed to cover a wide range of particle sizes which usually used in gas-solid spouted beds and gas-solid fluidized beds. Selected results have demonstrated the appropriateness of the advanced optical fiber in measuring both solids holdup and particles velocity in the experimental setups of the gas-solid spouted and fluidized beds. The measurements have been compared against independent techniques of gamma ray computed tomography (CT) and radioactive particle tracking (RPT).

42 ENGINEERING↗

Evaluation of thermal gradients in longitudinal spin Seebeck effect measurements

In the framework of the longitudinal spin Seebeck effect (LSSE), we developed an experimental setup for the characterization of LSSE devices. This class of device consists in a layered structure formed by a substrate, a ferrimagnetic insulator (YIG) where the spin current is thermally generated, and a paramagnetic metal (Pt) for the detection of the spin current via the inverse spin-Hall effect. In this kind of experiments, the evaluation of a thermal gradient through the thin YIG layer is a crucial point. In this work, we perform an indirect determination of the thermal gradient through the measurement of the heat flux. We developed an experimental setup using Peltier cells that allow us to measure the heat flux through a given sample. In order to test the technique, a standard LSSE device produced at Tohoku University was measured. We find a spin Seebeck S{sub SSE} coefficient of 2.8×10{sup −7} V K{sup −1}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time resolved 3D momentum imaging of ultrafast dynamics by coherent VUV-XUV radiation

We present a new experimental setup for measuring ultrafast nuclear and electron dynamics of molecules after photo-excitation and ionization. We combine a high flux femtosecond vacuum ultraviolet (VUV) and extreme ultraviolet (XUV) source with an internally cold molecular beam and a 3D momentum imaging particle spectrometer to measure electrons and ions in coincidence. We describe a variety of tools developed to perform pump-probe studies in the VUV-XUV spectrum and to modify and characterize the photon beam. First benchmark experiments are presented to demonstrate the capabilities of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating growth to detonation in vapor-deposited hexanitrostilbene and pentaerythritol tetranitrate films using high-throughput methods

In this work, a high-throughput experimental setup was used to characterize initiation threshold and growth to detonation in the explosives hexanitrostilbene (HNS) and pentaerythritol tetranitrate (PETN). The experiment sequentially launched an array of laser-driven flyers to shock samples arranged in a 96-well microplate geometry, with photonic Doppler velocimetry diagnostics to characterize flyer velocity and particle velocity at the explosive–substrate interface. Vapor-deposited films of HNS and PETN were used to provide numerous samples with various thicknesses, enabling characterization of the evolution of growth to detonation. One-dimensional hydrocode simulations were performed with reactions disabled to illustrate where the experimental data deviate from the predicted inert response. Prompt initiation was observed in 144 μm thick HNS films at flyer velocities near 3000 m/s and in 125 μm thick PETN films at flyer velocities near 2400 m/s. This experimental setup enables rapid quantification of the growth of reactions in explosive materials that can reach detonation at sub-millimeter length scales. These data can subsequently be used for parameterizing reactive burn models in hydrocode simulations, as discussed in Paper II [D. E. Kittell, R. Knepper, and A. S. Tappan, J. Appl. Phys. 131, 154902 (2022)].

36 MATERIALS SCIENCE↗

Study of relaxation and transport processes by means of AFM based dielectric spectroscopy

Since its birth a few years ago, dielectric spectroscopy studies based on atomic force microscopy (AFM) have gained a growing interest. Not only the frequency and temperature ranges have become broader since then but also the kind of processes that can be studied by means of this approach. In this work we analyze the most adequate experimental setup for the study of several dielectric processes with a spatial resolution of a few nanometers by using force mode AFM based dielectric spectroscopy. Proof of concept experiments were performed on PS/PVAc blends and PMMA homopolymer films, for temperatures ranging from 300 to 400 K. Charge transport processes were also studied by this approach. The obtained results were analyzed in terms of cantilever stray contribution, film thickness and relaxation strength. We found that the method sensitivity is strongly coupled with the film thickness and the relaxation strength, and that it is possible to control it by using an adequate experimental setup.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Sensitivity of a Single Water Cerenkov Detector to Monitor Forbush Decreases

We describe a simple experimental setup to measure the rate of arrival of muons at the surface of the Earth by using a single water Cerenkov detector and home-made electronics. We find a strong anti-correlation between the muon rates averaged over one-hour periods and the atmospheric pressure, with a measured correlation coefficient of -0.67% per hPa. After applying this correction we achieve sufficient sensitivity to observe long term (hours) variations in the averaged muon rates which are greater than 2%. Forbush decreases as big as 4% have been observed with muon detectors located at similar magnetic rigidities compared to Morelia, therefore our experimental setup will detect Forbush decreases as soon as the Sun enters into a more active phase.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bayesian Analysis of Pentaquark Signals from CLAS Data

We examine the results of two measurements by the CLAS collaboration, one of which claimed evidence for a {theta}{sup +} pentaquark, while the other found no such evidence. The unique feature of these two experiments was that they were performed with the same experimental setup. Using a Bayesian analysis, we find that the results of the two experiments are in fact compatible with each other, but that the first measurement did not contain sufficient information to determine unambiguously the existence of a {theta}{sup +}. Further, we suggest a means by which the existence of a new candidate particle can be tested in a rigorous manner.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data Efficiency Assessment of Generative Adversarial Networks for Critical Heat Flux Synthetic Data Generation

This study investigates the application of generative artificial intelligence techniques, particularly conditional generative adversarial networks (cGAN), in real-world engineering contexts, with a specific focus on synthetic data generation for critical heat flux (CHF). Utilizing a dataset comprising more than 20,000 real experimental CHF measurements, we conduct a series of experiments to examine cGAN’s behavior. These experiments encompass varying sizes of the training dataset, training cGAN on data from diverse experimental sources to generate new data on unseen experimental setups, and assessing the impact of excluding various input features on cGAN’s data generation accuracy. Our findings underscore the pronounced data dependency of cGAN for reliable performance, with decreased efficacy observed with smaller training dataset sizes. Notably, cGAN exhibits varying performance when trained on data from different experiments, with superior predictive capabilities observed for certain experiment sources compared to others. For instance, when cGAN was trained on data from Smolin et al.’s experiments or Zenkevich et al., it exhibited relatively good performance in generating the data from Becker et al., Kirillov et al., and Alekseev et al. experiments. In contrast, when trained with Alekseev et al.’s data and tasked with generating other experimental setups, cGAN showed notably poor performance. In both scenarios, cGAN’s performance was inferior compared to training on samples from all experiments concurrently. A feature importance analysis highlights the significant influence of parameters such as mass flux and heated length on accurate CHF generation, while other parameters like diameter and pressure have less impact. Inlet temperature is identified as a moderating factor by cGAN.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Note: Sample chamber for in situ x-ray absorption spectroscopy studies of battery materials

In situ x-ray absorption spectroscopy (XAS) provides element specific characterization of both crystalline and amorphous phases and enables direct correlations between electrochemical performance and structural characteristics of cathode and anode materials. In situ XAS measurements are very demanding to the design of the experimental setup. We have developed the sample chamber that provides electrical connectivity and inert atmosphere for the operating electrochemical cells and also accounts for x-ray interactions with chamber and the cell materials. The design of the sample chamber for in situ measurements is presented along with the example XAS spectra from the anode materials in operating pouch cells at Zn and Sn K-edges measured.in fluorescence and transmission modes respectively.

25 ENERGY STORAGE↗

Measurement of parity-violating asymmetry in electron-deuteron inelastic scattering

The parity-violating asymmetries between a longitudinally polarized electron beam and an unpolarized deuterium target have been measured recently. The measurement covered two kinematic points in the deep-inelastic scattering region and five in the nucleon resonance region. We provide here details of the experimental setup, data analysis, and results on all asymmetry measurements including parity-violating electron asymmetries and those of inclusive pion production and beam-normal asymmetries. The parity-violating deep-inelastic asymmetries were used to extract the electron-quark weak effective couplings, and the resonance asymmetries provided the first evidence for quark-hadron duality in electroweak observables. These electron asymmetries and their interpretation were published earlier, but are presented here in more detail.

Wang, D.↗

Thermal Management System for an Electric Machine with Additively Manufactured Hollow Conductors with Integrated Heat Pipes: Preprint

This paper discusses steps taken to size a thermal management system for an aircraft propulsion electric machine containing additively manufactured coils integrated with heat pipes aimed at boosting its specific power. Experimental setups are used to size and characterize heat pipes for the application and 3D thermal FEA is used to determine optimum heat transfer coefficient of convective boundaries. Geometric details of fin-based surface area enhancement required to reach target combined overall heat transfer coefficient (U) and surface area (A) performance (UA) in W/K, is worked out for relevant boundaries and the resulting UA is verified in 3D thermal FEA. Thermal management system's UA (by extension specific power) sensitivity to coolant temperature is explored and temperature distribution plots of optimized machine components are presented and discussed.

additive manufacturing↗

Construction and Commissioning of Gas Electron Multiplier (GEM) Detectors in Advanced Assembly Design for Low-Energy Applications at High Rates and Analysis of GEM Data From the Muse Experiment at PSI

The search beyond the Standard Model explores dark matter and a potential fifth force. DarkLight@ARIEL investigates the dark photon as a mediator between ordinary and dark matter. The experiment aims to measure the process e?Ta ? e?TaX ? e?Ta(e?e+), by detecting a charged lepton pair in the final state. The spectrometers will be instrumented with Gas Electron Multiplier (GEM) detectors with minimal material budget for tracking. A novel GEM construction technique is employed for fabricating 25 cm x 40 cm GEM detectors, where all layers are mechanically stretched and assembled within a double frame. The dissertation outlines physics motivation, methods, experimental setup, and the role of GEM detectors in DarkLight. A comprehensive discussion on GEM detectors, focusing on the "NS2" technique, including design, parts, assembly, testing, and performance evaluation will be discussed. The proton has garnered attention due to discrepancies in measuring its charge radius using muonic hydrogen and electron-based methods. The 2010 muonic hydrogen measurement of the proton charge radius Rp = 0.84184(67) fm, showed a significant 7? discrepancy compared to the previously known value of Rp = 0.8775(51) fm, giving rise to the proton radius puzzle. Through simultaneous measurements of e ? p and ? ? p elastic scattering, MUSE facilitates a precise and direct comparison of the proton radius. The physics background of the proton radius puzzle, measurement techniques, the approach adopted by the MUSE experiment, its significance and the experimental setup will be discussed. Furthermore, the role of GEM detectors, along with an in-depth analysis of their data and efficiency will be discussed and evaluated.

Mohammed Prem Nazeer, Sahara↗

Unraveling Bacterial Adaptation Strategies in the Microbiome Shaped by the Chemical Environment of the Plant Rhizosphere

The rhizosphere is a dynamic environment where rhizodeposits that include primary and secondary metabolites and mucilage serve as nutrient sources for soil microorganisms, attracting them toward plant roots. However, understanding how these microbes specifically respond to plant root chemical signals has been hindered by the challenges of disentangling physical and chemical interactions between the microbes and plant roots. To address this, we implemented an innovative filter-based experimental setup on plant roots that creates a physical barrier while facilitating the exchange of chemical signals. The proteomic analysis of 10 Populus root-associated bacterial strains grown in the presence or absence of a plant in either individual or mixed community conditions provided detailed insights into the functional responses of these strains to the root chemical environment. Additionally, this approach allowed us to discern the impact of root exudates on overall community dynamics. In particular, metaproteomic analyses revealed that each of these 10 microbial members responds uniquely to the presence of the plant, with Bacillus and Pantoea exhibiting the most dramatic favorable impact. Proteomic examination revealed the details of metabolism fine-tuning, including processes such as chemotaxis and ATP-binding cassette transporter proteins. This study demonstrates the application of a filter-based experimental setup to study microbial responses to plant chemicals and sheds light on adaptation strategies employed by various bacterial strains for survival in the rhizosphere.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

{sup 197}Au(n,gamma) cross section in the resonance region

The (n,gamma) cross section of {sup 197}Au has been measured at n{sub T}OF in the resolved resonance region, up to 5 keV, with the aim of improving the accuracy in an energy range where it is not yet considered standard. The measurements were performed with two different experimental setup and detection techniques, the total energy method based on C{sub 6}D{sub 6} detectors, and the total absorption calorimetry based on a 4pi BaF{sub 2} array. By comparing the data collected with the two techniques, two accurate sets of neutron-capture yields have been obtained, which could be the basis for a new evaluation leading to an extended cross-section standard. Overall good agreement is found between the n{sub T}OF results and evaluated cross sections, with some significant exceptions for small resonances. A few resonances not included in the existing databases have also been observed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗