Search NASA⌕ Search

SEARCH · Search NASA

Results for “failure temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Flow and fracture behavior of NiAl in relation to the brittle-to-ductile transition temperature

NiAl has only three independent slip systems operating at low and intermediate temperatures whereas five independent deformation mechanisms are required to satisfy the von Mises criterion for general plasticity in polycrystalline materials. Yet, it is generally recognized that polycrystalline NiAl can be deformed extensively in compression at room temperature and that limited tensile ductility can be obtained in extruded materials. In order to determine whether these results are in conflict with the von Mises criterion, tension and compression tests were conducted on powder-extruded, binary NiAl between 300 and 1300 K. The results indicate that below the brittle-to-ductile transition temperature (BDTT) the failure mechanism in NiAl involves the initiation and propagation of cracks at the grain boundaries which is consistent with the von Mises analysis. Furthermore, evaluation of the flow behavior of NiAl indicates that the transition from brittle to ductile behavior with increasing temperature coincides with the onset of recovery mechanisms such as dislocation climb. The increase in ductility above the BDTT is therefore attributed to the climb of the 001 line type dislocations which in combination with dislocation glide enable grain boundary compatibility to be maintained at the higher temperatures.

Noebe, R. D.↗

Water/glycol temperature control circuit failed in the automatic mode: Apollo 16

An anomaly report concerning failure of the water/glycol temperature control circuit during the Apollo 16 flight is presented. The anomaly is described and diagrams of the system are presented. The malfunction was caused by cracked semiconductor chips in the output silicon-controlled rectifier. Surface contamination in the crack allowed the device to self-gate on and remain on, resulting in a secondary failure of the feedback capacitor.

Source record↗

Impact and Penetration of Thin Aluminum 2024 Flat Panels at Oblique Angles of Incidence

The U.S. Federal Aviation Administration (FAA) and the National Aeronautics and Space Administration (NASA) are actively involved in improving the predictive capabilities of transient finite element computational methods for application to safety issues involving unintended impacts on aircraft and aircraft engine structures. One aspect of this work involves the development of an improved deformation and failure model for metallic materials, known as the Tabulated Johnson-Cook model, or MAT224, which has been implemented in the LS-DYNA commercial transient finite element analysis code (LSTC Corp., Livermore, CA) (Ref. 1). In this model the yield stress is a function of strain, strain rate and temperature and the plastic failure strain is a function of the state of stress, temperature and strain rate. The failure criterion is based on the accumulation of plastic strain in an element. The model also incorporates a regularization scheme to account for the dependency of plastic failure strain on mesh size. For a given material the model requires a significant amount of testing to determine the yield stress and failure strain as a function of the three-dimensional state of stress, strain rate and temperature. In addition, experiments are required to validate the model. Currently the model has been developed for Aluminum 2024 and validated against a series of ballistic impact tests on flat plates of various thicknesses (Refs. 1 to 3). Full development of the model for Titanium 6Al-4V is being completed, and mechanical testing for Inconel 718 has begun. The validation testing for the models involves ballistic impact tests using cylindrical projectiles impacting flat plates at a normal incidence (Ref. 2). By varying the thickness of the plates, different stress states and resulting failure modes are induced, providing a range of conditions over which the model can be validated. The objective of the study reported here was to provide experimental data to evaluate the model under more extreme conditions, using a projectile with a more complex shape and sharp contacts, impacting flat panels at oblique angles of incidence.

Ruggeri, Charles R.↗

Cryogenic Quenching Process for Electronic Part Screening

The use of electronic parts at cryogenic temperatures (less than 100 C) for extreme environments is not well controlled or developed from a product quality and reliability point of view. This is in contrast to the very rigorous and well-documented procedures to qualify electronic parts for mission use in the 55 to 125 C temperature range. A similarly rigorous methodology for screening and evaluating electronic parts needs to be developed so that mission planners can expect the same level of high reliability performance for parts operated at cryogenic temperatures. A formal methodology for screening and qualifying electronic parts at cryogenic temperatures has been proposed. The methodology focuses on the base physics of failure of the devices at cryogenic temperatures. All electronic part reliability is based on the bathtub curve, high amounts of initial failures (infant mortals), a long period of normal use (random failures), and then an increasing number of failures (end of life). Unique to this is the development of custom screening procedures to eliminate early failures at cold temperatures. The ability to screen out defects will specifically impact reliability at cold temperatures. Cryogenic reliability is limited by electron trap creation in the oxide and defect sites at conductor interfaces. Non-uniform conduction processes due to process marginalities will be magnified at cryogenic temperatures. Carrier mobilities change by orders of magnitude at cryogenic temperatures, significantly enhancing the effects of electric field. Marginal contacts, impurities in oxides, and defects in conductor/conductor interfaces can all be magnified at low temperatures. The novelty is the use of an ultra-low temperature, short-duration quenching process for defect screening. The quenching process is designed to identify those defects that will precisely (and negatively) affect long-term, cryogenic part operation. This quenching process occurs at a temperature that is at least 25 C colder than the coldest expected operating temperature. This quenching process is the opposite of the standard burn-in procedure. Normal burn-in raises the temperature (and voltage) to activate quickly any possible manufacturing defects remaining in the device that were not already rejected at a functional test step. The proposed inverse burn-in or quenching process is custom-tailored to the electronic device being used. The doping profiles, materials, minimum dimensions, interfaces, and thermal expansion coefficients are all taken into account in determining the ramp rate, dwell time, and temperature.

Sheldon, Douglas J.↗

Microsample Characterization of Coatings for Grcop-84 for High Heat Flux Applications

A multidisciplinary Johns Hopkins University-NASA Glenn team is undertaking a collaborative research program to elucidate and model the thermal stability and mechanical integrity of candidate coatings for GRCop-84. GRCop-84 is a high conductivity, high strength copper alloy that was recently developed at NASA Glenn for use in high temperature, high heat flux applications. With potential applications in rocket motor combustion chamber liners, nozzle ramps and other actively cooled structures, this new material offers great potential for decreasing weight and increasing reliability of third generation reusable launch vehicles. Current emphasis has turned toward the development of environmentally resistant and thermal barrier coatings for this alloy. Metallic coatings such as NiCrAlY and Cu-8-30%Cr have shown promise in: prohibiting blanching, reducing dog-house failures, increasing operating temperatures and decreasing cooling requirements. The focus of this research program is to develop a fundamental understanding of the substrate-coating interactions that occur during thermal cycling (inter-diffusion, viscoplasticity, morphological evolution, crack formation, etc.) and to derive a science-based protocol for future coating selection, optimization and reliability assurance. The microsample tensile testing approach adopted for this study allows us to characterize small-scale and highly scale-specific coatings and properties in a way not possible by conventional means. In addition to providing much needed design data, the integration of microsample testing with detailed microstructural observations provides a mechanistic foundation for coating optimization and life prediction modeling.

Hemker, Kevin↗

Investigation of energy transfer in the ignition mechanism of a NASA standard initiator

The principal objective of the proposed research was to construct a detailed computer model of the NASA Standard Initiator (NSI). The NSI plays a critical role in initiating various pyrotechnic events in the National Space Transportation System and is also used in Shuttle payload applications. Several initiators failed when being tested at very low temperatures (4 to 20 K). During subsequent investigation an unacceptable high failure rate was found even at higher temperatures (100 to 150 K) but the precise cause of failure was not determined. The modelling work was undertaken to investigate reasons for failure and to predict the performance of alternate firing schemes. The work has shown that the most likely cause of failure at low temperature is poor thermal contact between the electrically heated bridgewire and the pyrotechnic charge. This problem may be masked if there is good thermal contact between the bridgewire and the alumina charge cup. The high thermal conductivity of alumina at cryogenic temperatures was overlooked in previous analyses, which assumed that the charge cup acted as a thermal insulator.

Varghese, Philip L.↗

Accelerated Testing Methodology in Constant Stress-Rate Testing for Advanced Structural Ceramics: A Preloading Technique

Preloading technique was used as a means of an accelerated testing methodology in constant stress-rate ('dynamic fatigue') testing for two different brittle materials. The theory developed previously for fatigue strength as a function of preload was further verified through extensive constant stress-rate testing for glass-ceramic and CRT glass in room temperature distilled water. The preloading technique was also used in this study to identify the prevailing failure mechanisms at elevated temperatures, particularly at lower test rate in which a series of mechanisms would be associated simultaneously with material failure, resulting in significant strength increase or decrease. Two different advanced ceramics including SiC whisker-reinforced composite silicon nitride and 96 wt% alumina were used at elevated temperatures. It was found that the preloading technique can be used as an additional tool to pinpoint the dominant failure mechanism that is associated with such a phenomenon of considerable strength increase or decrease.

Choi, Sung R.↗

Accelerated Testing Methodology in Constant Stress-Rate Testing for Advanced Structural Ceramics: A Preloading Technique

Preloading technique was used as a means of an accelerated testing methodology in constant stress-rate (dynamic fatigue) testing for two different brittle materials. The theory developed previously for fatigue strength as a function of preload was further verified through extensive constant stress-rate testing for glass-ceramic and CRT glass in room temperature distilled water. The preloading technique was also used in this study to identify the prevailing failure mechanisms at elevated temperatures, particularly at lower test rates in which a series of mechanisms would be associated simultaneously with material failure, resulting in significant strength increase or decrease. Two different advanced ceramics including SiC whisker-reinforced composite silicon nitride and 96 wt% alumina were used at elevated temperatures. It was found that the preloading technique can be used as an additional tool to pinpoint the dominant failure mechanism that is associated with such a phenomenon of considerable strength increase or decrease.

Choi, Sung R.↗

ESTAR Measurements During SGP-99

The synthetic aperture radiometer, ESTAR, provided L-band brightness temperature maps of the experiment site during the Southern Great Plains Experiment in 1999. ESTAR flew on the NASA P-3 aircraft at an altitude of 7.6 km and mapped a swath about 50 km wide and about 300 km long. The area mapped extended west from Oklahoma City to El Reno and north from the Little Washita River watershed to the Kansas border. The flight lines and mapping were done in a manner similar to that used in 1997 during SGP-97. ESTAR is a prototype designed to develop the technology of aperture synthesis for passive microwave remote sensing. It is actually a hybrid that uses real aperture to obtain resolution along track and synthetic aperture to obtain resolution across track. ESTAR operates in the band at 1.413 GHz set aside for passive use and images at horizontal polarization in the equivalent of a cross-track scan. The scan is done in software as part of image reconstruction. Calibration consists of blackbody observed before and after each flight and a local body of water (Lake Kaw). ESTAR arrived in Oklahoma on July 7, 1999 and flew mapping missions on July 8,9, 11, 14, 15, 19 and 20. The aircraft was down on July 10 by design and was down again on July 12-13 and 16-18 due to mechanical problems. ESTAR data for July I I is questionable because of a hardware failure. The brightness temperature maps reflect the patterns of soil moisture observed in the SGP99 study area and compare well with measurements made by ESTAR in other experiments in this region (e.g. SGP -97 and Washita-92).

LeVine, D. M.↗

Room Temperature and Elevated Temperature Composite Sandwich Joint Testing

Testing of composite sandwich joint elements has been completed to verify the strength capacity of joints designed to carry specified running loads representative of a high speed civil transport wing. Static tension testing at both room and an elevated temperature of 350 F and fatigue testing at room temperature were conducted to determine strength capacity, fatigue life, and failure modes. Static tension test results yielded failure loads above the design loads for the room temperature tests, confirming the ability of the joint concepts tested to carry their design loads. However, strength reductions as large as 30% were observed at the elevated test temperature, where all failure loads were below the room temperature design loads for the specific joint designs tested. Fatigue testing resulted in lower than predicted fatigue lives.

Walker, Sandra P.↗

Use of thin plastic films at cryogenic temperatures

Commercially available plastic film materials that remain flexible at cryogenic temperatures and resist failures caused by folds and wrinkles created during expulsion were investigated for use in expulsion bladders for liquefied gases. Compatible adhesive systems, fabrication techniques, and results of impact and dynamic loading tests are summarized.

Lark, R. F.↗

Required critical aspect ratio of fibers intended for stress rupture applications.

The observed critical aspect ratio for pullout specimens of tungsten wire in a copper matrix tested in stress rupture at 649 and 816 C was slightly greater than for tension tests at the same temperature. Time for failure of the stress rupture specimens was controlled by the properties of the fiber (tungsten) at aspect ratios greater than the critical aspect ratio and by the properties of the matrix (copper) at aspect ratios less than the critical ratio.

Jech, R. W.↗

Experimental investigation of the buckling characteristics of a beaded skin panel for a hypersonic aircraft - Including comparisons with finite element and classical analyses

Results of a compression test of a beaded panel intended for a proposed hypersonic aircraft are presented. The panel was tested to failure at room temperature to determine its buckling characteristics, in particular, to study the buckling caused by pure compression. The boundary conditions of the panel simulated as nearly as possible a wing mounted condition. Strain, out-of-plane deflection, and load data were measured, and elastic buckling strength as well as mode shapes of the panel were determined. Application of the moire technique is described.

Siegel, W. H.↗

Experimental investigation of graphite/polyimide sandwich panels in edgewise compression

The local and general buckling behavior of graphite/polyimide sandwich panels simply supported along all four edges and loaded in uniaxial edgewise compression was investigated. Material properties of adhesive and facings were determined from flatwise tension and sandwich beam flexure tests. Tensile and compressive material properties of the facings were determined at 116, R.T., and 589 K (-250, R.T., and 600 F) using the sandwich beam flexure test method. Results indicate that Gr/PI is a usable structural material for short term use at temperatures as high as 589 K (600 F). Buckling specimens were 30.5 X 33.0 cm (12 x 13 in.), had quasi-isotropic symmetric facings and a glass/polyimide honeycomb core. Core thicknesses varied and three panels of each thickness were tested in edgewise compression at room temperature to investigate failure modes and corresponding buckling formulas. Specimens 0.635 cm (0.25 in.) thick failed by overall buckling at loads close to the analytically predicted buckling load; all other panels failed by face wrinkling. Results of the winkling tests indicate that several buckling formulas were unconservative and therefore not suitable for design purposes; recommended wrinkling equations are presented.

Camarda, C. J.↗

Tests of graphite/polyimide sandwich panels in uniaxial edgewise compression

The local and general buckling behavior of graphite/polyimide sandwich panels simply supported along all four edges and loaded in uniaxial edgewise compression were investigated. Material properties of sandwich panel constituents (adhesive and facings) were determined from flatwise tension and sandwich beam flexure tests. Buckling specimens were 30.5 by 33 cm, had quasi-isotropic, symmetric facings, and a glass/polyimide honeycomb core. Core thicknesses were varied and three panels of each thickness were tested at room temperature to investigate failure modes and corresponding buckling loads. Specimens 0.635 cm thick failed by overall buckling at loads close to the analytically predicted buckling load; all other panels failed by face wrinkling. Results of the wrinkling tests indicated that several buckling formulas were unconservative and therefore not suitable for design purposes; a recommended wrinkling equation is presented.

Camarda, C. J.↗

Flightweight radiantly and actively cooled panel: Thermal and structural performance

A 2- by 4-ft flightweight panel was subjected to thermal/structural tests representative of design flight conditions for a Mach 6.7 transport and to off-design conditions simulating flight maneuvers and cooling system failures. The panel utilized Rene 41 heat shields backed by a thin layer of insulation to radiate away most of the 12 Btu/ft2-sec incident heating. A solution of ethylene glycol in water circulating through tubes in an aluminum-honeycomb-sandwich panel absorbed the remainder of the incident heating (0.8 Btu/sq ft-sec). The panel successfully withstood (1) 46.7 hr of radiant heating which included 53 thermal cycles and 5000 cycles of uniaxial inplane loading of + or - 1200 lfb/in; (2) simulated 2g-maneuver heating conditions and simulated cooling system failures without excessive temperatures on the structural panel; and (3) the extensive thermal/structural tests and the aerothermal tests reported in NASA TP-1595 without significant damage to the structural panel, coolant leaks, or hot-gas ingress to the structural panel.

Shore, C. P.↗

Stable polyurethane coatings for electronic circuits. NASA tech briefs, fall 1982, volume 7, no. 1

One of the most severe deficiencies of polyurethanes as engineering materials for electrical applications has been their sensitivity to combined humidity and temperature environments. Gross failure by reversion of urethane connector potting materials has occurred under these conditions. This has resulted in both scrapping of expensive hardware and reduction in reliability in other instances. A basic objective of this study has been to gain a more complete understanding of the mechanisms and interactions of moisture in urethane systems to guide the development of reversion resistant materials for connector potting and conformal coating applications in high humidity environments. Basic polymer studies of molecular weight and distribution, polymer structure, and functionality were carried out to define those areas responsible for hydrolytic instability and to define polymer structural feature conducive to optimum hydrolytic stability.

Source record↗

Superplastic forming of Al-Li alloys for lightweight, low-cost structures

Superplastic forming of advanced aluminum alloys is being evaluated as an approach for fabricating low-cost, light-weight, cryogenic propellant tanks. Built-up structure concepts (with inherent reduced scrap rate) are under investigation to offset the additional raw material expenses incurred by using aluminum lithium alloys. This approach to fabrication offers the potential for significant improvements in both structural efficiency and overall manufacturing costs. Superplasticity is the ability of specially processed material to sustain very large forming strains without failure at elevated temperatures under controlled deformation conditions. It was demonstrated that superplastic forming technology can be used to fabricate complex structural components in a single operation and increase structural efficiency by as much as 60 percent compared to conventional configurations in skin-stiffened structures. Details involved in the application of this technology to commercial grade superplastic aluminum lithium material are presented. Included are identification of optimum forming parameters, development of forming procedures, and assessment of final part quality in terms of cavitation volume and thickness variation.

Hales, Stephen J.↗