Search NASA⌕ Search

SEARCH · Search NASA

Results for “fire test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The Atomic Cannon: Upshot-Knothole Grable

The May 25, 1952, Upshot-Knothole Grable event, aka Atomic Annie, proof tested a tactical nuclear weapon fashioned into a 280 mm cannon shell and fired from the Army’s M65 artillery piece. Travelling nearly seven miles downrange, Grable detonated with a force of fifteen kilotons 500 feet over a dry lake bed on the Nevada Test Site known as Frenchman Flat.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

CalTestBed - Delphire - Testing and Evaluation of Delphire Sentinel System (CRADA Final Report)

The Delphire Sentinel is a modular fire detection and communications system operating as a mobile field unit, with low voltage DC power supplied by onboard photovoltaics (PV) and batteries. The Sentinel addresses several aspects of fire detection, communications and data analysis. The Sentinel's mobility enables it to be rapidly deployed and operate independently of existing power and communications networks. The duration of independent operation depends critically on the energy consumption of the systems and performance of the onboard PV and battery. The purpose of this testing is to ascertain the power draw and energy consumption of the Delphire Sentinel prototype system under several operational states, including various data transfer packet sizes, transmission time and frequencies, and communication pathways (Wi-Fi, cellular, satellite) expected to be encountered in field deployments. It will also include procedures to test the ability of the Sentinel to operate for extended periods without loss of functionality. Based on results from energy and power measurements, and anticipated duty cycles in field deployments, we will model annual system autonomy (e.g. loss of load probability) for off-grid operation in representative locations.

47 OTHER INSTRUMENTATION↗

Development & Validation of Low-Cost, Highly-Durable, Spinel-Based Materials for SOFC Cathode-Side Contact (Final Report)

A cathode-side contact layer is required to provide and maintain stable electrical conduction paths between the interconnect and cathode in a solid oxide fuel cell (SOFC) stack assembly and thus minimize the ohmic resistance and stack power loss. Current cathode-interconnect contact materials are based on noble metals, electrically-conductive perovskites, their composite materials, etc. These materials are either too expensive or do not possess the overall balanced performance required for the cathode-side contact application. To achieve the DOE SOFC system cost and performance stability goals, a new generation of low-cost, high-performance contact materials needs to be developed. In this project, spinel-based materials thermally converted from the Fe-Ni and Co-Mn based alloy precursors were developed and validated for the cathode-side contact application. The precursor alloy compositions were optimized via a combination of composition screening in the (Ni,Fe) 3 O 4 and (Mn,Co) 3 O 4 spinel system, alloy design using physical metallurgy principles, and cost considerations. The alloy powders with the desired composition and particle size were manufactured via gas atomization. The optimal process parameters for thermal conversion of these alloy precursor layers to a spinel-based layer were identified, i.e., 900°C x 2h in air, which is close to the initial stack firing condition. The area-specific resistances (ASRs) of the interconnect/contact/cathode test assemblies with the developed contact layer were determined for various durations (up to 5000 h) under simulated cathodic operation conditions. Some of the alloy-derived spinel contacts exhibited the lowest ASR and ASR degradation rate. The in-stack performance of the most promising alloy-derived contact layer is currently being evaluated via stack testing. To reduce the stack cost, the Co-Mn based alloy powders were utilized as the precursor for synthesis of dense spinel-based interconnect coating. By optimizing both the initial powder size/distribution and the alloy powder composition, a dense (Mn,Co) 3 O 4 -based spinel coating was achieved. Furthermore, co-sintering of the coating/contact dual-layer structure under the initial stack firing condition was realized by utilizing the tailored Co-Mn alloy precursors. Cost analysis of the developed technology indicated a total stack cost reduction of around 10.6% with the implementation of co-sintering of the interconnect coating and the contact layer during initial stack firing. Since low-cost processes such as screen printing is utilized in the precursor application and no reduction heat treatment is needed for the coating formation, the developed technology can be readily implemented at the industrial partner’s manufacturing facilities with no additional capital investment needed.

08 HYDROGEN↗

The effect of terrain-influenced winds on fire spread in QUIC-Fire

Here in this manuscript, we describe the implementation of the terrain-following version of QUIC-URB into QUIC-Fire and a demonstration of the impacts of terrain-influenced winds on QUIC-Fire-simulated fire spread. No changes to the underlying QUIC-Fire fire spread algorithm were made other than what was required to correctly account for the inclusion of terrain. This paper summarizes simulations used to understand how the QUIC-URB terrain-influenced winds affect upslope fire behavior without additional changes to the QUIC-Fire fire spread algorithm. Previously published FIRETEC results are compared to simulation results from the modified QUIC-Fire (incorporating terrain-influenced winds) that use the same topographies and fuels. QUIC-Fire results showed overall similar behaviors in terms of how the topographies affected fire shapes and trends in spread rates. Due to the terrain-following version of QUIC-URB being unable to generate flow separations at the crest of hills, fire spread rates in these regions across all non-flat topographies were over-predicted when compared to FIRETEC. Lateral fire growth showed similar trends with FIRETEC between topographies but did not capture the increase in spread due to a diagonal interface between grassland and forested fuel regions in the test domain. These simulations suggest possible refinements that are necessary to improve QUIC-Fire and thus guide ongoing efforts related to: how flame tilt angle is accounted for, the incorporation of non-local drag effects, and the inclusion of the wake-eddy parameterizations that are used in QUIC-URB.

54 ENVIRONMENTAL SCIENCES↗

Supercritical Carbon Dioxide Primary Power Large-Scale Pilot Plant

The United States electrical power generation fleet encompasses a wide range of technologies, ranging from traditional combustion-based power generation, to nuclear power, to renewable energy. While the distribution of these assets continues to shift due to economic and regulatory influences, coal combustion continues to be a key part of the US energy portfolio. Despite the relative maturity of coal combustion technology, improvements in overall fuel-to-power efficiency and generation flexibility are still possible and will improve both the economic and environmental factors of coal combustion. Echogen Power Systems proposes to lead a world-class team including the University of Missouri, Electric Power Research Institute and Louis Perry Associates in the design, construction and operation of a 10MWe coal-fired supercritical carbon dioxide (sCO 2 ) large-scale pilot. This transformational technology uses sCO 2 as a working fluid instead of water to achieve high thermodynamic efficiencies that can significantly exceed advanced steam-Rankine cycles. Further, the compact nature of sCO 2 turbomachinery offers capital cost and footprint advantages, and the low maintenance of a water-free power cycle can significantly reduce operation and maintenance (O&M) costs over conventional steam-Rankine systems. Recent integration studies of sCO 2 with coal combustion power plants highlight the significant improvements in plant efficiency that sCO 2 can offer relative to even advanced steam Rankine cycles. At commercial scales, coal-sCO 2 plant net efficiency is predicted to be 39-44.0% (HHV), or 10-20% higher output than conventional steam-Rankine systems, which will significantly improve the competitiveness of coal-fired generation. This proposal builds upon projects previously funded by the Department of Energy, including DE-FE0025959 (High-Efficiency Thermal Integration of Closed Supercritical CO 2 Brayton Power Cycles with Oxy-Fired Heaters) and DE-NE0008470 (Conceptual Design for sCO 2 Power Cycle Test Facility). An appropriately-scaled and properly designed and operated pilot project is essential to overcome the natural risk-aversion of the power generation industry and project financing community. The 10 MWe coal-fired sCO 2 pilot power plant proposed herein will reduce the technical and economic risk of this transformational technology, enabling commercial deployment at the conclusion of the project. For the second phase of this project, Echogen lead a team that completed and refined the pilot system conceptual system and key component designs resulting in the completion of a front-end-engineering-design (FEED) study, completed the NEPA review process, completed the permitting process for construction and operation, refined the techno-economic analysis of the proposed system at commercial scale and received commitments for Phase III cost share. The end result of the program will be to demonstrate the technical and economic superiority of the sCO 2 power cycle for coal-fired operation. Major risk elements will have been retired with sufficient operation at high power to enable the power generation industry to move forward with the first commercial deployment of this transformational system.

01 COAL, LIGNITE, AND PEAT↗

Predicting High Energy Arcing Fault Zones of Influence for Aluminum Using an Arc Flash Modeling Approach: Evaluation of a model bias, uncertainty, parameter sensitivity and zone of influence estimation

This report documents the development of an arc flash hazard model to calculate the incident energy and zone of influence from high energy arcing faults involving aluminum. The NRC has identified the potential for (HEAFs) involving aluminum to increase the damage zone beyond what is currently postulated in fire probabilistic risk assessment (PRA) methodologies. To estimate the hazard from HEAFs involving aluminum an arc flash model was developed. Differences between the initial model and nuclear power plant (NPP) fire PRA scenarios were identified. Modification of the initial model established from existing literature and test data was used to minimize these differences. The developed model was evaluated against NRC datasets to understand the model prediction and relative uncertainties. Finally, a range of fire PRA zone of influences (ZOI) were developed based on the developed model, target fragility estimates and update HEAF PRA methodology. The results were developed to support an NRC LIC-504 evaluation in tandem with other modeling efforts. The report documents the effort and provides a reference for any future advancements in arc flash modeling.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Compressible battery foams to prevent cascading thermal runaway in Li-ion pouch batteries

Lithium-ion battery packs require thermal management to achieve optimum life and safety. This is becoming crucial for battery packs composed of high-energy-density cells. Pouch cells themselves achieve highest packaging efficiency but require additional structural support and thermal management when grouped into modules, especially under abusive conditions such as thermal runaway. Novel foam battery pads have demonstrated to cushion volume changes of pouch cells and are reengineered in this study to mitigate cell-to-cell thermal runaway propagation. The compressible pads are made of polyurethane foams incorporating flame-retardant additives or coatings, including intumescent and fire wall materials. Here their performances were evaluated by conducting nail penetration tests on modules composed of pouch cells at 100% state of charge (SOC), with the foams placed in between the cells. Experimental results show cascading thermal runaway was considerably delayed by polyurethane foams incorporating flame-retardant additives or coatings. Complete prevention of cascading failure was achieved with dense polyurethane foams with multilayered coatings of both fire wall and intumescent materials.

25 ENERGY STORAGE↗

Development and experimental evaluation of new building air leakage measurement methods: measurement of interior air leaks and comparison to conventional methods

Building air leaks (both through exterior and interior surfaces) can have a significant impact on energy consumption, indoor air quality, fire safety, and moisture accumulation affecting structural durability. Blower door testing has been used to measure leaks in buildings, but commonly used testing methods do not directly measure interior leaks. In this paper, new testing methods (guarded interior test and zonal multipoint pressure testing method) are presented that directly measure these interior leaks, utilizing common blower door equipment for both single and multi-point testing. Furthermore, these new methods are compared to conventional methods in terms of the information provided, limitations and time/effort needed. In addition, building leak measurement results are analyzed to reveal a) coupling between power law model values (exponent and coefficient) for an ensemble of buildings, b) the error in using single point testing when estimating low pressure leakage, and c) how building power law models vary from low to high pressure ranges.

99 GENERAL AND MISCELLANEOUS↗

Sodium Fire Collaborative Study Progress CNWG Fiscal Year 2021

This report discusses the progress on the collaboration between Sandia National Laboratories (Sandia) and Japan Atomic Energy Agency (JAEA) on the sodium fire research in fiscal year (FY) 2021 and is a continuation of the FY2020 progress report. In this report, we only report the changes made to the current sodium pool fire model in MELCOR. We modified and corrected many control functions to enhance the current model from the FY2020 report. This year’s enhancements relate to better agreement of the suspended aerosol measurement from JAEA’s F7 series tests. Staff from Sandia and JAEA conducted the validation studies of the sodium pool fire model in MELCOR. To validate this pool fire model with the latest enhancement, JAEA sodium pool fire experiments (F7-1 and F7-2) were used. The results of the calculation, including the code-to-code comparisons are discussed as well as suggestions for further model improvement. Finally, recommendations are made for new MELCOR simulations for FY2022.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The time since land-use transition drives changes in fire activity in the Amazon-Cerrado region

Abstract Deforestation and climate change are expected to alter fire regimes along the Cerrado-Amazon transition, one of the world’s most active agricultural frontiers. Here we tested the hypothesis that the time since land-use transition (age of frontier) and agricultural intensification also drive changes in the region’s fire regimes by reducing fire probability in both drought and non-drought years. We modeled fire probability as a function of the time since land-use transitions based on MapBiomas Project datasets from 1986 to 2020. We find that, while burned area declined as pasturelands aged and croplands advanced, deforestation abruptly increased fire activity before (Amazon: 4 years; Cerrado: 3 years) and after (Amazon: 8 years; Cerrado: 7 years) land clearing for pasture, especially in the Amazon. Additionally, the combination of ignition risk, drought, and air-dryness increased the likelihood of large extents of burned areas associated with deforestation. Incorporating frontier age as a proxy for governance in fire modeling is crucial, given the ecological implications of changing fire regimes despite declining rates of fire probability. Most importantly, protecting against deforestation and preserving native vegetation are vital.

Environmental Sciences & Ecology↗

Wildfire-Power Grid Interactions: Feedback, Impacts, Monitoring, Modeling, and Mitigation Strategies

Wildfires are increasingly interacting with electric power systems through a two-way hazard chain: fires damage grid assets and trigger cascading outages, while grid faults can ignite new fires under hot, dry, and windy conditions. This review synthesizes the state of knowledge across five domains: (i) physical impacts of flames, heat, and smoke on lines, towers, insulators, and substations; (ii) power-infrastructure-initiated ignitions via conductor clash, high-impedance faults, and corona discharge; (iii) widespread blackouts and disproportionate societal impacts; (iv) multi-scale monitoring spanning laboratory tests, in-situ and grid-integrated sensors, and Earth observation; (v) coupled modeling that links fire behavior with grid operations; and (vi) technological and strategic mitigation pathways spanning prevention, response, and recovery. We integrate these domains into a novel 'feedback-aware' socio-technical framework. Through a longitudinal analysis (2005-2025) of global incidents, we identify that while vegetation contact remains the most frequent ignition source, aging infrastructure failure has emerged as a critical driver of catastrophic 'mega-fires'. We further identify persistent gaps, including limited interoperability of high-frequency grid and environmental data, scarce real-time data assimilation, and under-developed equity metrics for outage management. We conclude by outlining a research agenda to (1) deploy interoperable sensing architectures, (2) advance feedback-coupled fire-grid simulations, and (3) evaluate mitigation portfolios through techno-economic and fairness lenses. Recognizing wildfire-grid interactions as coupled socio-technical systems is essential for protecting infrastructure and communities and for ensuring reliable, sustainable electricity in a changing world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO2) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO 2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-Fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO 2 ) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO 2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Sorbent Based Post-Combustion CO 2 Slipstream Testing

TDA Research, Inc. has developed a low-cost sorbent (alkalized alumina) based technology for post-combustion CO 2 capture. The sorbent runs in an isothermal process for adsorption and regeneration. Neither temperature swing nor pressure swing is needed. TDA designed a system which operated 10 fixed beds to simulate a moving bed process. The flow pattern was optimized to minimize the steam usage for regeneration. An excellent sorbent (Batch 1) was also developed with collaboration with our partner. The sorbent degraded after long term operation. We developed a reprocessing procedure, which can be conducted in situ, to restore the sorbent capture capacity as the fresh sorbent after running for about 1250 hours. The reprocessing extended the sorbent longevity significantly. TDA designed a pilot unit (40’ x 32’ x 11.5’), processing flue gas equivalent to 0.5 MW of power generation. It had 10 beds and each bed could hold 1.75 m 3 of sorbent. We worked with Springs Fabrication, Inc. to complete the construction of the pilot unit. It was then shipped and installed at NCCC. The pilot unit was kept running in 24-hour mode when the flue gas and steam were available. It could run automatically without operator on site. Parametric and long-term (2 months) tests were carried out successfully. The results showed that TDA’s process can achieve 90% capture and 95% CO 2 purity for both coal and NG flue gases. For coal flue gas, the system reached performance target when processing up to 0.62 MW flue gas, 24% higher than the design capacity. Thus, capital cost could be saved on the reactors and sorbent. The strip air flow was designed to be 0.25 of that of the flue gas. The test data showed the strip/flue ratio can be reduced to as little as 0.18, which saves the power consumption for the strip air blower. The pressure drop was found to be lower than what the empirical equation calculated. The sorbent still had 91.7% of original capacity after 3-month test. With the data from the pilot test, we updated the TEA. For a 550-MW e supercritical coal fired power plant with CO 2 capture, the capture cost for TDA’s process is $34.9/tonne CO 2 captured, which meets DOE’s goal of $40/tonne and is 17.1% less than the DOE baseline Case 12. Therefore, TDA’s process has a good potential for commercialization.

01 COAL, LIGNITE, AND PEAT↗

Simulation of Deuterium Oxidation in a Room with a Fire

A series of experiments where deuterium was released in trace amounts into a room with a fire were performed at Sandia National Laboratories. This report describes the corresponding effort to model the test series using SIERRA/FUEGO. The objective of this modeling effort was to produce a simulation test matrix that can be utilized to help interpret the corresponding experiments and be used to assess the credibility of using the SIERRA/FUEGO simulations as a surrogate for real tritium reaction data for mock fire and release studies. The simulations assessed multiple configurations of fire size and location and overall found that there was low conversion of deuterium to oxidized deuterium. There are some notable differences between the simulation predictions and the experimental results, such as the simulations generally predicting higher amounts of deuterium conversion compared to the experiment. A strategy to address modeling uncertainties and unknowns is also given in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sodium Fire Collaborative Study Progress (CNWG Fiscal Year 2022)

This report discusses the progress on the collaboration between Sandia National Laboratories (Sandia) and Japan Atomic Energy Agency (JAEA) on the sodium fire research in fiscal year (FY) 2022 and is a continuation of the FY 2021 progress report. We only report the changes made to the current sodium pool fire model in MELCOR. We modified and corrected many control functions to enhance the fraction of oxygen consumed that reacts to form monoxide (FO2) parameter in the current model from the FY2021 report. This year's enhancements relate to better agreement of the suspended aerosol measurement from JAEA's F7 series tests. Staff from Sandia and JAEA conducted the validation studies of the sodium pool fire model in MELCOR. To validate this pool fire model with the latest enhancement, JAEA sodium pool fire experiments (F7-1 and F7-2) were used. The results of the calculation, including the code-to-code comparisons are discussed as well as suggestions for further model improvement. Finally, recommendations are made for new MELCOR simulations for FY 2023.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A long-term pilot-scale algal cultivation on power plant flue gas – Cultivation stability and biomass accumulation

A long-term culture of a selected freshwater microalgal assemblage on power plant flue gas was realized using a pilot-scale photobioreactor. Different culture conditions of light cycle, harvesting amount, pH stabilization, and sulfur addition were tested during a 12-month continuous operation at a natural gas fired power plant. The results concluded that the daily harvesting amount of 60% with no light-cycle and NH 4 NO 3 as the nitrogen source and pH stabilization agent, resulted in optimal cultivation performance. Biomass concentration and biomass productivity reached 1.07 ± 0.23 g L -1 and 0.43 ± 0.14 g L -1 d -1 , respectively. During the year-long cultivation period, the algal assemblage was relatively stable with average abundances of 88 ± 4% and 12 ± 4% for algae and bacteria, respectively, and no significant differences between individual case scenarios. The stable culture fostered a stable biomass composition. Protein, carbohydrate, and lipid contents of the algal biomass were 58.60 ± 2.41%, 19.5 ± 2.44%, and 9.70 ± 1.68%, respectively.

09 BIOMASS FUELS↗

Hardtack II

Armed and ready to fire, Adams remained suspended under a balloon high over the Nevada Test Site throughout the day and night of October 31, 1958. Shortly after midnight, Adams was lowered to the ground and disarmed. With that, Operation Hardtack II ended and a test moratorium, primarily a gentlemen’s agreement between the United States and the Soviet Union, took effect. As the possibility of a moratorium became more and more likely in late 1957, the Atomic Energy Commission and its two weapon laboratories sought Presidential approval for an unprecedented number of tests for the coming year, including a proposal by the UCRL for a series of underground and safety tests in an operation called Millrace. Not wanting to jeopardize ongoing international disarmament talks as well as the moratorium, itself, Eisenhower resisted giving approval for Millrace until late August 1958, barely two months before the anticipated start of the moratorium. Millrace, quickly renamed Hardtack II, was expanded to thirty-seven tests beginning with Otero on September 12 th and concluding with Titania on October 30 th . Eighteen devices, including Otero and Titania, were safety tests. Three of these tests explored “safety characteristics for underground detonations” in tunnels. Two of the three such tests vented. In this respect, Hardtack II was a harbinger of the future in that the problem of venting was never fully resolved. Other safety tests, designed to give no yield, were more successful with San Juan, Oberon, and Ganymede having “no measurable yield.”

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗