Search NASA⌕ Search

SEARCH · Search NASA

Results for “flash storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Fuels Containing Methane of Natural Gas in Solution

While exploring ways of producing better fuels for propulsion of a spacecraft on the Mars sample return mission, a researcher at Johnson Space Center (JSC) devised a way of blending fuel by combining methane or natural gas with a second fuel to produce a fuel that can be maintained in liquid form at ambient temperature and under moderate pressure. The use of such a blended fuel would be a departure for both spacecraft engines and terrestrial internal combustion engines. For spacecraft, it would enable reduction of weights on long flights. For the automotive industry on Earth, such a fuel could be easily distributed and could be a less expensive, more efficient, and cleaner-burning alternative to conventional fossil fuels. The concept of blending fuels is not new: for example, the production of gasoline includes the addition of liquid octane enhancers. For the future, it has been commonly suggested to substitute methane or compressed natural gas for octane-enhanced gasoline as a fuel for internal-combustion engines. Unfortunately, methane or natural gas must be stored either as a compressed gas (if kept at ambient temperature) or as a cryogenic liquid. The ranges of automobiles would be reduced from their present values because of limitations on the capacities for storage of these fuels. Moreover, technical challenges are posed by the need to develop equipment to handle these fuels and, especially, to fill tanks acceptably rapidly. The JSC alternative to provide a blended fuel that can be maintained in liquid form at moderate pressure at ambient temperature has not been previously tried. A blended automotive fuel according to this approach would be made by dissolving natural gas in gasoline. The autogenous pressure of this fuel would eliminate the need for a vehicle fuel pump, but a pressure and/or flow regulator would be needed to moderate the effects of temperature and to respond to changing engine power demands. Because the fuel would flash as it entered engine cylinders, relative to gasoline, it would disperse more readily and therefore would mix with air more nearly completely. As a consequence, this fuel would burn more nearly completely (and, hence, more cleanly) than gasoline does. The storage density of this fuel would be similar to that of gasoline, but its energy density would be such that the mileage (more precisely, the distance traveled per unit volume of fuel) would be greater than that of either gasoline or compressed natural gas. Because the pressure needed to maintain the fuel in liquid form would be more nearly constant and generally lower than that needed to maintain compressed natural gas in liquid form, the pressure rating of a tank used to hold this fuel could be lower than that of a tank used to hold compressed natural gas. A mixture of natural gas and gasoline could be distributed more easily than could some alternative fuels. A massive investment in new equipment would not be necessary: One could utilize the present fuel-distribution infrastructure and could blend the gasoline and natural gas at almost any place in the production or distribution process - perhaps even at the retail fuel pump. Yet another advantage afforded by use of a blend of gasoline and natural gas would be a reduction in the amount of gasoline consumed. Because natural gas costs less than gasoline does and is in abundant supply in the United States, the cost of automotive fuel and the demand for imported oil could be reduced.

Sullivan, Thomas A.↗

Gas detectors for x-ray lasers

We have developed different types of photodetectors that are based on the photoionization of a gas at a low target density. The almost transparent devices were optimized and tested for online photon diagnostics at current and future x-ray free-electron laser facilities on a shot-to-shot basis with a temporal resolution of better than 100 ns. Characterization and calibration measurements were performed in the laboratory of the Physikalisch-Technische Bundesanstalt at the electron storage ring BESSY II in Berlin. As a result, measurement uncertainties of better than 10% for the photon-pulse energy and below 20 {mu}m for the photon-beam position were achieved at the Free-electron LASer in Hamburg (FLASH). An upgrade for the detection of hard x-rays was tested at the Sub-Picosecond Photon Source in Stanford.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Temporal Locality-Aware Page-Mapped Flash Translation Layer

The poor performance of random writes has been a cause of major concern which needs to be addressed to better utilize the potential of flash in enterprise-scale environments. We examine one of the important causes of this poor performance: the design of the flash translation layer (FTL) which performs the virtual-to-physical address translations and hides the erase-before-write characteristics of flash. We propose a complete paradigm shift in the design of the core FTL engine from the existing techniques with our Demand-Based Flash Translation Layer (DFTL) which selectively caches page- level address mappings. Our experimental evaluation using FlashSim with realistic enterprise-scale workloads endorses the utility of DFTL in enterprise-scale storage systems by demonstrating: 1) improved performance, 2) reduced garbage collection overhead and 3) better overload behavior compared with hybrid FTL schemes which are the most popular implementation methods. For example, a predominantly random-write dominant I/O trace from an OLTP application running at a large financial institution shows a 78% improvement in average response time (due to a 3-fold reduction in operations of the garbage collector), compared with the hybrid FTL scheme. Even for the well-known read-dominant TPC-H benchmark, for which DFTL introduces additional overheads, we improve system response time by 56%. Moreover, interestingly, when write-back cache on DFTL-based SSD is enabled, DFTL even outperforms the page-based FTL scheme, improving their response time by 72% in Financial trace.

Address Mapping Table↗

The Global Trigger Processor: A VXS Switch Module for Triggering Large Scale Data Acquisition Systems

The 12 GeV upgrade for Jefferson Lab's Continuous Electron Beam Accelerator Facility requires the development of a new data acquisition system to accommodate the proposed 200 kHz Level 1 trigger rates expected for fixed target experiments at 12 GeV. As part of a suite of trigger electronics comprised of VXS switch and payload modules, the Global Trigger Processor (GTP) will handle up to 32,768 channels of preprocessed trigger information data from the multiple detector systems that surround the beam target at a system clock rate of 250 MHz. The GTP is configured with user programmable Physics trigger equations and when trigger conditions are satisfied, the GTP will activate the storage of data for subsequent analysis. The GTP features an Altera Stratix IV GX FPGA allowing interface to 16 Sub-System Processor modules via 32 5-Gbps links, DDR2 and flash memory devices, two gigabit Ethernet interfaces using Nios II embedded processors, fiber optic transceivers, and trigger output signals. The GTP's high-bandwidth interconnect with the payload modules in the VXS crate, the Ethernet interface for parameter control, status monitoring, and remote update, and the inherent nature of its FPGA give it the flexibility to be used large variety of tasks and adapt to future needs. This paper details the responsibilities of the GTP, the hardware's role in meeting those requirements, and elements of the VXS architecture that facilitated the design of the trigger system. Also presented will be the current status of development including significant milestones and challenges.

Kaneta, Scott↗

New Total-Ionizing-Dose Resistant Data Storing Technique for NAND Flash Memory

This paper describes a new non-charge-based data storing technique in NAND flash memory called watermark that encodes read-only data in the form of physical properties of flash memory cells. Unlike traditional charge-based data storing method in flash memory, the proposed technique is resistant to total ionizing dose (TID) effects. To evaluate its resistance to irradiation effects, we analyze data stored in several commercial single-level-cell (SLC) flash memory chips from different vendors and technology nodes. These chips are irradiated using a Co-60 gamma-ray source array for up to 100 krad(Si) at Sandia National Laboratories. Experimental evaluation performed on a flash chip from Samsung shows that the intrinsic bit error rate (BER) of watermark increases from 0.8% for TID = 0 krad(Si) to 1% for TID = 100 krad(Si). Conversely, the BER of charge-based data stored on the same chip increases from 0% at TID = 0 krad(Si) to 1.5% at TID = 100 krad(Si). Overall, the results imply that the proposed technique may potentially offer significant improvements in data integrity relative to traditional charge-based data storage for very high radiation (TID > 100 krad(Si)) environments. These gains in data integrity relative to the charge-based data storage are useful in radiation-prone environments, but they come at the cost of increased write times and higher BERs before irradiation.

36 MATERIALS SCIENCE↗

Nonvolatile Memory Solution for Near-Term NASA Missions

Nonvolatile memory (NVM) system that could reliably function in extreme environments is one of the most critical components for many spacecrafts being developed for NASA missions to be launched in next four to seven years. NVM supports the computer system in saving and updating critical state data required for a warm restart after power cycling or in case of a power bus failure. It also provides a power independent mass storage capacity for the scientific data gathered by the instruments. In some cases the window for gathering such data is very small and occurs only once in a given mission. Commercially popular and fully developed Flash NVM technology is inappropriate for many reasons such as the limited read write cycles with slower access speeds, radiation intolerance, higher Single Event Upsets (SEU) rates, etc. It is desirable to have an NVM system based upon a robust cell technology making it immune to the SEUs and with sufficient radiation hardness. Availability of such NVM system seems to be still 5 to 10 years in the future. Meanwhile, it is possible to provide an interim hybrid solution by combining the existing rad-hard technologies. Additional information is contained in the original extended abstract.

Patel, J. U.↗

Thermal conductivity measurement using modulated photothermal radiometry for nitrate and chloride molten salts

Molten salts are being used or explored for thermal energy storage and conversion systems in concentrating solar power and nuclear power plants. Thermal conductivity of molten salts is an important thermophysical property dictating the performance and cost of these systems, but its accurate measurement has been challenging, as evidenced by wide scattering of existing data in literature. The corrosive and conducting nature of these fluids also leads to time consuming sample preparation processes of many contact-based measurements. Here, in this work, we report the measurement of thermal conductivity of molten salts using a modulated photothermal radiometry (MPR) technique, which is a laser-based, non-contact, frequency-domain method adopted for molten salts for the first time. By unitizing the advantages of front side sensing of frequency-domain measurements and the vertical holder orientation, the technique can minimize the natural convection and salt creeping effects, thus yielding accurate molten salt thermal conductivity . The MPR technique is first calibrated using standard molten materials including paraffin wax and sulfur. It is then applied on measuring pure nitrate salts (NaNO 3 and KNO 3 ), solar salt (NaNO 3 –KNO 3 mixture), and chloride salt (NaCl–KCl–MgCl 2 ). The measurement results are compared with data from literature, especially those obtained from laser flash analysis (LFA). Our results demonstrate that the MPR is a convenient and reliable technique of measuring thermal conductivity of molten salts. Accurate thermal conductivity data of molten salts will be valuable in developing the next-generation high-temperature thermal energy storage and conversion systems.

14 SOLAR ENERGY↗

Thermal reliability of Al-Si eutectic alloy for thermal energy storage

Highlights: • Thermal reliability of material is investigated after long time vacuum thermal cycling. • The latent heat of fusion show almost no change after 1000 thermal cycles. • The thermal conductivity exhibit a good stability after 1000 cycles. • Al-Si eutectic alloy is a potentially good candidate for thermal energy storage applications. - Abstract: The thermal reliability of Al-Si eutectic alloy as phase change materials (PCMs) was investigated through vacuum thermal cycling 250, 500, 750, and 1000 times going through the solid-liquid phase change. The changes in thermal properties of Al-Si eutectic alloy, including melting point, latent heat, specific heat, thermal diffusivity and thermal conductivity, were investigated using differential scanning calorimetric (DSC) and laser flash apparatus. The results revealed that, with increasing the number of cycles, the melting point and latent heat of fusion of the Al-Si eutectic alloy showed almost no changes. Moreover, the thermal conductivity showed an outstanding stability after 1000 thermal cycles. Therefore, it is concluded that the thermal reliability of Al-Si eutectic alloy is more than adequate for long-term performance as a phase change material for thermal energy storage (TES) applications.

36 MATERIALS SCIENCE↗

Exploiting Internal Parallelism for Address Translation in Solid-State Drives

Solid-state Drives (SSDs) have changed the landscape of storage systems and present a promising storage solution for data-intensive applications due to their low latency, high bandwidth, and low power consumption compared to traditional hard disk drives. SSDs achieve these desirable characteristics using internal parallelism—parallel access to multiple internal flash memory chips—and a Flash Translation Layer (FTL) that determines where data are stored on those chips so that they do not wear out prematurely. However, current state-of-the-art cache-based FTLs like the Demand-based Flash Translation Layer (DFTL) do not allow IO schedulers to take full advantage of internal parallelism, because they impose a tight coupling between the logical-to-physical address translation and the data access. In this study to address this limitation, we introduce a new FTL design called Parallel-DFTL that works with the DFTL to decouple address translation operations from data accesses. Parallel-DFTL separates address translation and data access operations into different queues, allowing the SSD to use concurrent flash accesses for both types of operations. We also present a Parallel-LRU cache replacement algorithm to improve the concurrency of address translation operations. To compare Parallel-DFTL against existing FTL approaches, we present a Parallel-DFTL performance model and compare its predictions against those for DFTL and an ideal page-mapping approach. We also implemented the Parallel-DFTL approach in an SSD simulator using real device parameters, and used trace-driven simulation to evaluate Parallel-DFTL’s efficacy. Our evaluation results show that Parallel-DFTL improved the overall performance by up to 32% for the real IO workloads we tested, and by up to two orders of magnitude with synthetic test workloads. Finally, we also found that Parallel-DFTL is able to achieve reasonable performance with a very small cache size and that it provides the best benefit for those workloads with large request size or with high write ratio.

97 MATHEMATICS AND COMPUTING↗

Accelerating Flash-X Simulations with Asynchronous I/O

Most high-fidelity physics simulation codes, such as Flash-X, need to save intermediate results (checkpoint files) to restart or gain insights into the evolution of the simulation. These simulation codes save such intermediate files synchronously, where computation is stalled while the data is written to storage. Depending on the problem size and computational requirements, this file write time can be a substantial portion of the total simulation time. In order to hide the I/O latency of checkpointing, asynchronous I/O methods have been introduced. These methods use background threads for performing I/O while the main threads continue with the simulation. The usage of background threads can compete for resources on the node as well as with communication. In this paper, we evaluate the overheads and the overall benefit of asynchronous I/O in HDF5 to simulations. Results from real-world high-fidelity simulations on the Summit supercomputer show that I/O operation is overlapped with application communication or computation or both, effectively hiding some or all of the I/O latency. Our evaluation shows that while using asynchronous I/O adds overhead to the application, the I/O time reduction is more significant, resulting in overall up to 1.5X performance speedup.

Jain, Rajeev↗

An investigation of the phototropic effect on seedling orientation in a microgravity environment: A student involvement project

A microgravity growth chamber was designed to investigate the phototropic response of radish seedlings. Enclosed in a one fourth inch thick, hexagonal, fiberglass-foam spacepak nineteen inches across corners, the experiment consists of a growth chamber and germination tray, a water reservoir and solenoid valve, a fluorescent light for photo simulation, a Minolta X700 camera with programmable back, a 50 mm macro lens and flash, a battery pack, and a computer controller. Two temperature sensors and one light sensor located in the walls of the growth chamber provide temperature and illumination data. A computer provides 8 K command and 34 K data storage capability. The experiment was not activated during the STS flight because a malfunctioning latching relay stuck and reduced the battery power level.

Barainca, J. W.↗

Local structure effects of carbon-doping on the phase change material Ge 2 Sb 2 Te 5

Ge 2 Sb 2 Te 5 is used in phase change memory, a nonvolatile memory technology, due to its phase change properties. The primary advantage of phase change memory over the state-of-the-art (flash memory) is its simple and small device geometry, which allows for denser nodes and lower power consumption. In phase change memory, resistive heating induces fast switching between the high resistance amorphous and low resistance crystalline phases, corresponding to storage of low and high digital states, respectively. However, the instability of the amorphous phase of Ge 2 Sb 2 Te 5 presents issues with processing and long-term data storage; such issues can be resolved by C doping, which stabilizes the amorphous phase and raises the crystallization temperature. To better understand the local structural effects of C doping on Ge 2 Sb 2 Te 5 , in situ Ge K-edge X-ray absorption spectroscopy measurements were taken during heating of films with various C doping concentrations. Here, the range of structural transformation temperatures derived from X-ray absorption near-edge structure analysis across the C doping series proved narrower than crystallization temperatures reported in similar in situ X-ray diffraction experiments, which may reflect changes in local structure that precede long-range ordering during crystallization. In addition, rigorous extended X-ray absorption fine structure fitting across and between temperature series revealed effects of C doping on the rigidity of Ge–Te bonds at low (2 at% and 4 at%) C concentrations.

Langhout, John D.↗

Groundwater management of a highly dynamic karst by assessing baseflow and quickflow with a rainfall-discharge model (Dardennes springs, SE France)

This paper aims at characterizing the groundwater flow in a highly dynamic karst aquifer using a global modeling approach based on rainfall and spring discharge time series. The Dardennes aquifer (SE France) was studied as it is used for drinking water supply and it also produces karst flash floods that increase the flood hazard downstream in urban areas. Three years of data were available, including a normal rainy year, a wet year and a dry year. Modeling was performed with the new platform KarstMod, a rainfall-discharge model with calibration tools. The Dardennes aquifer model was structured with three interconnected reservoirs: Epikarst, Matrix, and Conduit. Using this modeling approach, we were able to determine the groundwater hydrograph separation of the karst spring discharge, at the annual scale and at the event scale (flood). This gives insight into the low flow (Matrix) available for the drinking water demand and the fast flow (Conduit) that generates flash floods. In such a dynamic aquifer, part of the water budget cannot be accounted for by water resources as fast flow is not stored within the aquifer and is not available for the drinking water demand. The results were compared with the current groundwater management to determine whether the withdrawal is sustainable. Depending on whether it is a wet or a dry year, the proportion of slow flow ranges from 27 to 61% of the total discharge, respectively. During floods in high water periods, the proportion of quickflow increases drastically up to more than 90% of the spring discharge. In the case of a 300 mm/d simulated Mediterranean rainfall event, the mean daily peak value may reach 74 m 3 /s. This discharge can be reduced if the aquifer is previously depleted, which increases the storage within the aquifer. Coupling the geological context and the model results opens up future perspectives for the active management of the karst aquifer.

58 GEOSCIENCES↗

SiC-Based Wireless Power Transformation for Data Centers & Medium Voltage Applications

Data centers have grown in physical size and their electrical power consumption has grown to levels of several 100kW and approaching 1 GW in large installations. The low voltage electrical distribution inside of Data Centers consists of several conversion stages and a lot of wiring to bring the power from medium voltage (MV) levels outside of the building to the low voltage levels that the servers and racks require. Energy losses during distribution and conversion and high incident arc flash energy levels at the point of use are significant. The electrical distribution system is complex and costly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal properties of simulated Hanford waste glasses

Abstract The Hanford Tank Waste Treatment and Immobilization Plant will vitrify the mixed hazardous wastes generated from 45 years of plutonium production at the Hanford Site in Washington State. The molten glasses will be poured into stainless steel containers or canisters and subsequently cooled for storage and disposal. For appropriate facility design and operations to handle such highly energy‐consuming processes, knowledge of the material properties is required. The thermal properties (heat capacity, thermal diffusivity, and thermal conductivity) of representative high‐level and low‐activity waste glasses were studied as functions of temperature in the range of 200°C‐800°C (relevant to the cooling process). Simultaneous differential scanning calorimetry‐thermal gravimetry (DSC‐TGA), Xe‐flash diffusivity, pycnometry, and dilatometry were implemented. The study showed that simultaneous DSC‐TGA would be a reliable method for obtaining the heat capacity of various glasses in the temperature range of interest. Accurate thermal properties from this study were shown to provide a more realistic guideline for capacity and time constraints of the heat removal process when compared to the original conservative design‐basis engineering estimates. The estimates, though useful for design in the absence of measured physical properties, can now be supplanted and the measured thermal properties can be used in design verification activities.

Rodriguez, Carmen P.↗

Investigation of Natural Circulation Instability and Transients in Passively Safe Small Modular Reactors

The NEUP funded project, NEUP-3496, aims to experimentally investigate two-phase natural circulation flow instability that could occur in Small Modular Reactors (SMRs), especially for natural circulation SMRs. The objective has been achieved by systematically performing tests to study the general natural circulation instability characteristics and the natural circulation behavior under start-up or design basis accident conditions. Experimental data sets highlighting the effect of void reactivity feedback as well as the effect of power ramp-up rate and system pressure have been used to develop a comprehensive stability map. The safety analysis code, RELAP5, has been used to evaluate experimental results and models. Improvements to the constitutive relations for flashing have been made in order to develop a reliable analysis tool. This research has been focusing on two generic SMR designs, i.e. a small modular Simplified Boiling Water Reactor (SBWR) like design and a small integral Pressurized Water Reactor (PWR) like design. A BWR-type natural circulation test facility was firstly built based on the three-level scaling analysis of the Purdue Novel Modular Reactor (NMR) with an electric output of 50 MWe, namely NMR-50, which represents a BWR-type SMR with a significantly reduced reactor pressure vessel (RPV) height. The experimental facility was installed with various equipment to measure thermalhydraulic parameters such as pressure, temperature, mass flow rate and void fraction. Characterization tests were performed before the startup transient tests and quasi-steady tests to determine the loop flow resistance. The control system and data acquisition system were programmed with LabVIEW to realize the realtime control and data storage. The thermal-hydraulic and nuclear coupled startup transients were performed to investigate the flow instabilities at low pressure and low power conditions for NMR-50. Two different power ramps were chosen to study the effect of startup power density on the flow instability. The experimental startup transient results showed the existence of three different flow instability mechanisms, i.e., flashing instability, condensation induced flow instability, and density wave oscillations. In addition, the void-reactivity feedback did not have significant effects on the flow instability during the startup transients for NMR-50. ii Several initial startup procedures with different power ramp rates were experimentally investigated to eliminate the flow instabilities observed from the startup transients. Particularly, the very slow startup transient and pressurized startup transient tests were performed and compared. It was found that the very slow startup transients by applying very small power density can eliminate the flashing oscillations in the single-phase natural circulation and stabilize the flow oscillations in the phase of net vapor generation. The initially pressurized startup procedure was tested to eliminate the flashing instability during the startup transients as well. The pressurized startup procedure included the initial pressurization, heat-up, and venting process. The startup transient tests showed that the pressurized startup procedure could eliminate the flow instability during the transition from single-phase flow to two-phase flow at low pressure conditions. The experimental results indicated that both startup procedures were applicable to the initial startup of NMR. However, the pressurized startup procedures might be preferred due to short operating hours required. In order to have a deeper understanding of natural circulation flow instability, the quasi-steady tests were performed using the test facility installed with preheater and subcooler. The effect of system pressure, core inlet subcooling, core power density, inlet flow resistance coefficient, and void reactivity feedback were investigated in the quasi-steady state tests. The experimental stability boundaries were determined between unstable and stable flow conditions in the dimensionless stability plane of inlet subcooling number and Zuber number. To predict the stability boundary theoretically, linear stability analysis in the frequency domain was performed at four sections of the natural circulation test loop. The flashing phenomena in the chimney section was considered as an axially uniform heat source. And the dimensionless characteristic equation of the pressure drop perturbation was obtained by considering the void fraction effect and outlet flow resistance in the core section. The theoretical flashing boundary showed some discrepancies with previous experimental data from the quasi-steady state tests. In the future, thermal non-equilibrium was recommended to improve the accuracy of flashing instability boundary. As another part of the funded research, flow instabilities of a PWR-type SMR under low pressure and low power conditions were investigated experimentally as well. The NuScale reactor design was selected as the prototype for the PWR-type SMR. In order to experimentally study the natural circulation behavior of NuScale iii reactor during accidental scenarios, detailed scaling analyses are necessary to ensure that the scaled phenomena could be obtained in a laboratory test facility. The three-level scaling method is used as well to obtain the scaling ratios derived from various non-dimensional numbers. The design of the ideally scaled facility (ISF) was initially accomplished based on these scaling ratios. Then the engineering scaled facility (ESF) was designed and constructed based on the ISF by considering engineering limitations including laboratory space, pipe size, and pipe connections etc. PWR-type SMR experiments were performed in this well-scaled test facility to investigate the potential thermal hydraulic flow instability during the blowdown events, which might occur during the loss of coolant accident (LOCA) and loss of heat sink accident (LOHS) of the prototype PWR-type SMR. Two kinds of experiments, normal blowdown event and cold blowdown event, were experimentally investigated and compared with code predictions. The normal blowdown event was experimentally simulated since an initial condition where the pressure was lower than the designed pressure of the experiment facility, while the code prediction of blowdown started from the normal operation condition. Important thermal hydraulic parameters including reactor pressure vessel (RPV) pressure, containment pressure, local void fraction and temperature, pressure drop and natural circulation flow rate were measured and analyzed during the blowdown event. The pressure and water level transients are similar to the experimental results published by NuScale [51], which proves the capability of current loop in simulating the thermal hydraulic transient of real PWR-type SMR. During the 20000s blowdown experiment, water level in the core was always above the active fuel assemble during the experiment and proved the safety of natural circulation cooling and water recycling design of PWR-type SMR. Besides, pressure, temperature, and water level transient can be accurately predicted by RELAP5 code. However, the oscillations of natural circulation flow rate, water level and pressure drops were observed during the blowdown transients. This kind of flow oscillations are related to the water level and the location upper plenum, which is a path for coolant flow from chimney to steam generator and down comer. In order to investigate the transients start from the opening of ADS valve in both experimental and numerical way, the cold blow-down experiment is conducted. For the cold blowdown event, different from setting both reactor iv pressure vessel (RPV) and containment at high temperature and pressure, only RPV was heated close to the highest designed pressure and then open the ADS valve, same process was predicted using RELAP5 code. By doing cold blowdown experiment, the entire transients from the opening of ADS can be investigated by code and benchmarked with experimental data. Similar flow instability observed in the cold blowdown experiment. The comparison between code prediction and experiment data showed that the RELAP5 code can successfully predict the pressure void fraction and temperature transient during the cold blowdown event with limited error, but numerical instability exists in predicting natural circulation flow rate. Besides, the code is lack of capability in predicting the water level related flow instability observed in experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Developing a Facile Technology for Converting Domestic US Coal into High-Value Graphene

Universal Matter Ltd. was formed in July 2019 to scale-up and commercialize a breakthrough process, Flash Joule Heating (FJH), to transform different coal grades, into high-quality graphene. This graphene is made using a high-voltage electric discharge that brings the carbon source to temperatures higher than 3,000 K in less than 10 milliseconds. The short burst of electricity breaks all chemical bonds in the feedstock and reorders the carbon atoms into exceptionally thin layers of a special type of graphene, at an estimated $100 per ton in electricity cost. This process is capable of producing 1-5 layer-thick high-quality graphene (with defects of <0.05% and purity of >99%) in a green, practical, and cost-effective process. The graphene produced in the FJH process is a very special kind of graphene called “turbostratic graphene” (TG). TG offers superior physical properties compared to other graphene structures on a similar weight basis. Unlike graphene made from graphite using traditional techniques, the graphene layers in TG stack in an irregular pattern that allows the graphene powder to be exfoliated more easily and blend more evenly within other materials. The TG produced using our FJH technology is the most economical graphene product that opens up significant large volume markets for end-use applications; it would allow the use of TG made from coal for commercial applications in several market segments including energy storage, sensors, hyper-lubricants, reinforced plastics, and building materials such as concrete.

01 COAL, LIGNITE, AND PEAT↗

Solar-Powered Aerogel-Based Adsorptive Air Conditioning

The DOE estimates the total primary energy consumption for commercial buildings was 10.72 quadrillion BTU (quads) in 1983, compared with 14.74 quads for the residential sector. According to the DOE Building Technologies Program, 40–60% of the energy used in U.S. commercial (and residential) buildings is for HVAC, creating massive potential for energy savings with a system that could cut cooling energy use by at least 30–60%. Initial vertical segments in the commercial building market include government and commercial office buildings; government facilities such as prisons, military bases, and schools; hotels and resorts; farming, wineries and other rural facilities; and general light industrial offices (e.g., printers and clothing makers). We propose a solar powered aerogel-based adsorption cooling system, including the completion and testing of a working prototype at an existing HVAC testing facility and technology-maturation testing at an existing beta-testing site. In the cooling system, solar radiation is focused by solar collectors onto on bed, which contains ultra high surface area aerogel. Heating causes thermal desorption of a refrigerant previously adsorbed into the aerogel’s pores. Refrigerant desorption increases the gas-phase pressure in the pores, thereby forcing the gaseous refrigerant to flow out of the first irradiated bed (Bed A) and through a two-stage condenser. In the condenser, heat is first removed from the hot gaseous refrigerant by a stream of water that eventually flows into a hot water heater and storage system. The refrigerant is then further cooled by chilled refrigerant leaving the evaporator after vaporization. After passing through the two-stage condenser, the gaseous refrigerant undergoes expansion through an expansion valve. A portion of the refrigerant condenses in the evaporator, while some of the refrigerant is flashed and exits the evaporator. The evaporator absorbs heat from the area being cooled, which results in further vaporization of the refrigerant. The cool, vaporized refrigerant leaves the evaporator, passing through tubes in the shell-and-tube heat exchanger comprising the second stage of the two-stage condenser. After leaving the tube side of this heat exchanger, it flows to the second bed of aerogel (Bed B), which is maintained at a relatively low temperature by water entering the building and destined for the hot water tank. During the first cycle, most of the refrigerant adsorbs on Bed B. When the refrigeration cycle is reversed, the refrigerant is thermally desorbed from Bed B, and adsorbed on the cooler Bed A. As the cycling rate increases, the quantity of adsorption media, the system size, and the associated cost becomes smaller. It appears that an optimized system can meet targeted performance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗