Search NASA⌕ Search

SEARCH · Search NASA

Results for “flip angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

114 records · Page 7

K-Band Phased Array Developed for Low- Earth-Orbit Satellite Communications

Future rapid deployment of low- and medium-Earth-orbit satellite constellations that will offer various narrow- to wide-band wireless communications services will require phased-array antennas that feature wide-angle and superagile electronic steering of one or more antenna beams. Antennas, which employ monolithic microwave integrated circuits (MMIC), are perfectly suited for this application. Under a cooperative agreement, an MMIC-based, K-band phased-array antenna is being developed with 50/50 cost sharing by the NASA Lewis Research Center and Raytheon Systems Company. The transmitting array, which will operate at 19 gigahertz (GHz), is a state-of-the-art design that features dual, independent, electronically steerable beam operation ( 42 ), a stand-alone thermal management, and a high-density tile architecture. This array can transmit 622 megabits per second (Mbps) in each beam from Earth orbit to small Earth terminals. The weight of the total array package is expected to be less than 8 lb. The tile integration technology (flip chip MMIC tile) chosen for this project represents a major advancement in phased-array engineering and holds much promise for reducing manufacturing costs.

Anzic, Godfrey↗

Measurements of leading neutron production in polarized pp collisions at RHIC-PHENIX

In 2001-2002, we performed an experiment to search for non-zero single transverse spin asymmetry in very forward angle, 0-2.8 mrad, with first polarized pp collision in {radical}(s) = 200 GeV at RHIC, and an unexpected large asymmetry for leading neutron production was discovered. For further investigation, we have measured the cross section with the PHENIX detector in the similar kinematics region. The observed asymmetries are consistent with the previous results measured in an experiment at the 12 o'clock interaction point at RHIC. The measured cross section are consistent with the Feynman-x scaling claimed by the ISR experiments which measured leading neutrons in pp collisions at {radical}(s) = 30.6-62.7 GeV. These cross sections in large Feynman-x, as well as those in ep collisions at HERA experiments, are well described by a pion exchange model. Therefore, the observed large asymmetry for leading neutrons is considered to come from an interference between spin-flip amplitude with the pion exchange and non-flip with Reggeon exchanges.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tuning the electronic properties of MgB 2 by substitution with Mn and C

We use high-resolution angle-resolved photoemission spectroscopy (ARPES) to investigate the electronic band structure of the superconductors Mg 0.995 Mn 0.005 B 2 and Mg(B 0.98 C 0.02 ) 2 , in comparison with pristine MgB 2 . Our experimental findings reveal modest changes in the size of the Fermi surface sheets following manganese or carbon substitution, with the most pronounced effect observed in the outermost σ band. Additionally, the dispersion kink, indicative of strong renormalization due to the interaction between conduction electrons and phonon modes near −0.065 eV, remains unaffected by chemical substitution. Given that the superconducting transition temperature decreases significantly more rapidly in Mn-substituted MgB 2 than in C-substituted MgB 2 , our ARPES results strongly suggest that the primary mechanism behind the pronounced T C suppression in Mn–MgB 2 is the disruption of Cooper pairs via Abrikosov–Gorkov spin-flip scattering caused by the local magnetic moments of Mn.

ARPES↗

Hybridized kagome bands and induced Ti magnetism in RTi3Bi4 (R = Nd, Sm, Gd) kagome metals studied using angle-resolved photoemission spectroscopy and x-ray magnetic circular dichroism

Kagome materials are known for hosting emergent quantum phenomena driven by the interaction between different lattice, charge and spin orders. Here, we present a detailed angle resolved photoemission (ARPES), density functional theory (DFT) and x-ray magnetic circular dichroism (XMCD) study of the electronic and magnetic structure of RTi3Bi4 (R = Nd, Sm, Gd). ARPES and DFT demonstrate that the bulk electronic band structure is dominated by the hybridization of the Ti bands, and the weak electron-like pocket at Γ is identified as a surface state. The isotropic XAS profile of the M 4,5-edge of the rare earth is consistent with the presence of R 3+ oxidation state. Using the XMCD sum rules, backed by the atomic multiplet theory calculations, we obtain the spin and orbital magnetic moments. The Ti L2,3-edge XMCD reveals the presence of a small magnetic moment in GdTi3Bi4, presumably driven by the proximity of the Ti kagome layers to the zigzag chains of Gd, while the total magnetic moment of Gd is shared by the f and d electrons. Our combined XMCD, ARPES and DFT study brings an important piece of information to understand the spin flip transitions and anomalous Hall effect observed in the RTi3Bi4 kagome metals.

Lim, C.↗

BXS Re-calibration

Early in the commissioning it was noticed by Cecile Limborg that the calibration of the BXS spectrometer magnet seemed to be different from the strength of the BX01/BX02 magnets. First the BX01/BX02 currents were adjusted to 135 MeV and the beam energy was adjusted to make the horizontal orbit flat. Then BX01/BX02 magnets were switched off and BXS was adjusted to make the horizontal orbit in the spectrometer line flat, without changing the energy of the beam. The result was that about 140-141 MeV were required on the BXS magnet. This measurement was repeated several times by others with the same results. It was not clear what was causing the error: magnet strength or layout. A position error of about 19 mm of the BXS magnet could explain the difference. Because there was a significant misalignment of the vacuum chamber in the BXS line, the alignment of the whole spectrometer line was checked. The vacuum chamber was corrected, but the magnets were found to be in the proper alignment. So we were left with one (or conceivably two) magnet calibration errors. Because BXS is a wedged shaped magnet, the bend angle depends on the horizontal position of the incoming beam. As mentioned, an offset of the beam position of 19 mm would increase or decrease the bend angle roughly by the ratio of 135/141. The figure of 19 mm is special and caused a considerable confusion during the design and measurement of the BXS magnet. This is best illustrated in Figure 1 which was taken out of the BXS Traveler document. The distance between the horizontal midplanes of the poles and the apex of the beam path was chosen to be 19 mm so the beam is close to the good field region throughout its entire path. Thus it seemed possible that there was an error that resulted in the beam not being on this trajectory, or conversely, that the magnetic measurements were done on the wrong trajectory and the magnet was then mis-calibrated. Mechanical measurements of the vacuum chamber made in the tunnel indicated that the vacuum chamber was in fact in the proper position with respect to the magnet - not 19 mm off to one side - so the former possibility was discounted. Review of the Fiducial Report and an interview with Keith Caban convinced me that there was no error in the coordinate system used for magnet measurements. I went and interviewed Andrew Fischer who did the magnetic measurements of BXS. He had extensive records, including photographs of the setups and could quickly answer quite detailed questions about how the measurement was done. Before the interview, I had a suspicion there might have been a sign flip in the x coordinate which because of the wedge would result in the wrong path length and a miscalibration. Andrew was able to pin-point how this could have happened and later confirmed it by looking an measurement data from the BXG magnet done just after BXS and comparing photographs. It turned out that the sign of the horizontal stage travel that drives the measurement wire was opposite that of the x coordinate in the Traveler, and the sign difference wasn't applied to the data. The origin x = 0 was set up correctly, but the wire moved in the opposite direction to what was expected, just as if the arc had been flipped over about the origin. To quantitatively confirm that this was the cause of the observed difference in calibration I used the 'grid data', which was taken with a Hall probe on the BXS magnet originally to measure the FINT (focusing effect) term, and combined it with the Hall probe data taken on the flipped trajectory, and performed the field integral on a path that should give the same result as the design path. This is best illustrated in Figure 2. The integration path is coincident with the desired path from the pivot points (x = 0) outward. Between the pivot points the integration path is a mirror image of the design path, but because the magnet is fairly uniform, for this portion it gives the same result. Most of the calibration error resulted simply from the different path length between the design path and the measured path. The results of the integration on the equivalent path are given in Table 1. The corrected calibration has been used to generate a new polynomial for BXS which was implemented in the control system.

43 PARTICLE ACCELERATORS↗

Extraction and Parametrization of Isobaric Trinucleon Elastic Cross Sections and Form Factors

By mining data from Jefferson Lab Hall A experiment E08-014 a new 3 He elastic cross section was extracted from a large quasielastic background. This measurement was taken with an initial beam energy of 3.356 GeV and an angle of 20.51°. The cross section was found to be 1.345 × 10 -6 µb/sr ± 0.086 × 10 -6 µb/sr at Q 2 = 34.19 fm -2 . This new data point falls approximately halfway between the first and second diffractive minima of the 3 He form factors. When combined with recent high Q 2 3 He elastic cross section measurements from Jefferson Lab and MIT-Bates this new data point improves our knowledge of the cross section and form factors at large momentum transfers. The new high Q 2 data motivate a reanalysis of the 3 He elastic cross section world data and provide an improved understanding of the magnetic form factor in particular. For this analysis the elastic cross section world data for 3 He, and its mirror nuclei 3 H, were collected. The world data spans a time frame from 1965 to 2016. The dataset contains electron energy ranges from tens of MeV to above 12 GeV for measurements performed at many different facilities. The world data were then fit using a sum of Gaussians parametrization which allowed for the extraction of both targets’ magnetic and electric form factors which were then used to calculate charge densities and radii. The new charge and magnetic form factors for 3 H and the charge form factor for 3 He are in good agreement with the 1994 fits from Amroun et al . However, the addition of the new high Q 2 data has caused the 3 He magnetic form factor’s first diffractive minimum to shift up in Q 2 by 1-3 fm -2 while also decreasing the magnitude of the magnetic form factor above Q2 ≈ 20 fm -2 . The first diffractive minima for 3H are located at Q2 ≈ 13 fm -2 and Q 2 ≈ 23-24 fm -2 for the charge and magnetic form factors respectively. The first diffractive minima for 3 He are located at Q 2 ≈ 11 fm -2 and Q 2 ≈ 17-20 fm -2 for the charge and magnetic form factors respectively. The charge radius for 3 He was found to be 1.90 fm ± 0.00144 fm in reasonable agreement with past measurements, and the charge radius for 3 H was found to be 2.02 fm ± 0.0133 fm which is much larger than past measurements. However, each of these charge radii has an additional uncertainty that must be applied to them due to allowing all parameters to float freely during the sum of Gaussians fitting procedure. This additional uncertainty should be small for 3 He, but it is likely quite significant for 3 H and would help bring this charge radius closer to agreement with past measurements that made different fitting choices. Unfortunately, this analysis was unable to quantify this additional uncertainty. The new form factor fits were compared to modern theoretical predictions from the 2016 paper of Marcucci et al . The ‘conventional’ theoretical approach applied in this paper modelled two and three-body nucleon interactions with relativistic corrections and was reasonably successful at predicting the charge form factors of 3 H and 3 He. χEFT predictions were also often successful. However, while the ‘conventional’ approach still performed best, theory failed to accurately predict the magnetic form factors of either 3 H or 3 He. The first diffractive minimum of the new 3 He magnetic form factor fits actually moved further away from theory. This disagreement between theory and experiment provides motivation for new asymmetry measurements using polarized 3 He and a polarized electron beam. When the beam is scanned in Q 2 on the target the sign of the asymmetry will flip at the form factor minima pinning down their true location.

Barcus, Scott↗