Induction flowmeter for dielectric fluids, experimental verification final report
Experimental verification of induction flow meter for use with dielectric fluids
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Experimental verification of induction flow meter for use with dielectric fluids
Capacitive mass flow meter with electronic readout for use with liquid hydrogen
Cryogenic fluid mass flow measurement methods, noting flow meter calibration
Volumetric system calibrates meters used for large liquid flow rates. The system employs trip probes and equipment to time the flow of liquid from a tare vessel into a calibrated vessel. This calibration system is used in the petroleum and chemical industries.
An orifice flow system has been developed indigenously which is a primary standard for the calibration of high vacuum gauges in the range of 10{sup -3}-10{sup -6} mbar. It consists of a constant-volume flow meter, designed to generate a known flow rate of a particular gas to the vacuum chamber. This chamber is partitioned into two parts by a plate with an orifice of calculable conductance. The pressures, generated by this standard system, are compared with those of secondary standard, namely, spinning rotor gauge. Different uncertainties and correction factors are calculated. The maximum percentage deviation is from 1.16% to 0.97%. The combined uncertainties over the entire calibration range of the standard system are in the range of 4.0x10{sup -6} mbar.
Leakage monitoring of separable connectors for liquid propellant rocket engine during assembly and flow meter detection during engine firing
Calibration of turbine-type flow meters in liquid hydrogen
Experimental data are analyzed to support theoretical predictions for discharge coefficients in circular-arc venturi flow meters operating in the critical sonic flow regime at throat Reynolds numbers above 150 thousand. The data tend to verify the predicted 0.25% decrease in the discharge coefficient during transition from a laminar to turbulent boundary layer. Four different test gases and three flow measurement facilities were used in the experiments with 17 venturis with throat sizes from 0.15 to 1.37 in. and Beta ratios ranging from 0.014 to 0.25. Recommendations are given as to how the effectiveness of future studies in the field could be improved.
Combustion deposits reduce transfer of heat. Instrument measures fouling like that on gas side of heat exchanger in direct-fired boiler or heat-recovery system. Heat-flux probe includes tube with embedded meter in outer shell. Combustion gases flow over probe, and fouling accumulates on it, just as fouling would on heat exchanger. Embedded heat-flow meter is sandwich structure in which thin Chromel layers and middle alloy form thermopile. Users determine when fouling approaches unacceptable levels so they schedule cleaning and avoid decreased transfer of heat and increased drop in pressure fouling causes. Avoids cost of premature, unnecessary maintenance.
Analysis of the results from the STS-114 tanking tests and subsequent launch called into question existing thermal and mass models of helium pressurization of the liquid hydrogen tank. This hydrogen tank, which makes up the bottom two-thirds of the External Tank, is pressurized prior to launch to avoid cavitation in the Shuttle Main Engine pumps. At about 2 minutes prior to launch, the main vent valve is closed, and pressurized helium flows into the tank ullage space to achieve set point pressure. As the helium gas cools, its pressure drops, calling for additional helium. Subsequent helium flows are provided in short, timed pulses. The number of pulses is taken as a rough leak indicator. An analysis of thermal models by Marshall Space Flight Center showed considerable uncertainty in the pressure-versus-time behavior of the helium ullage space and the ability to predict the number of pulses normally expected. Kennedy Space Center proposed to calibrate the dime-sized orifice, which together with valves, controls the helium flow quantity (Figure 1). Pressure and temperature sensors were installed to provide upstream and downstream measurements necessary to compute flow rate based on the orifice discharge coefficient. An assessment of flow testing with helium indicated an extremely costly use of this critical resource. In order to reduce costs, we proposed removing the orifices from each Mobile Launcher Platform (MLP) and asking Colorado Engineering Experiment Station Inc. (CEESI) to calibrate the flow. CEESI has a high-pressure air flow system with traceable flow meters capable of handling the large flow rates. However, literature research indicated that square-edged orifices of small diameters often exhibit significant hysteresis and nonrepeatability in the vicinity of choked or sonic flow. Fortunately, the MLP orifices behaved relatively well in testing (Figure 2). Using curve fitting of the air-flow data, in conjunction with ASME orifice modeling equations, a method of relating the helium mass flow to measured air flow data was obtained. This analysis showed that the highest uncertainty in flow occurred in the vicinity of the choking pressure ratio, as would be expected. In addition, analysis of typical flow pulses showed that most of the helium flow occurred either well below or well above this uncertain area. The final result is the ability to provide postlaunch estimates of helium mass flows that are within 1.5 percent of the actual value.
In this report we have catalogued the flow regimes observed in microgravity, summarized correlations for the pressure drop and rate of heat transfer that are commonly used, and discuss the validation of a few correlations from available experimental results. Two-phase flow through some specific components such as bends, tees, filters and pumps are discussed from a physical perspective to guide the designer on how reduced gravity might affect their performance. Phase separation in zero gravity is addressed through the behavior and basic design concepts for devices based on passive centrifugal action, capillary forces, gas extraction through a membrane installed in a channel wall and the use of a syringe with a perforated piston to remove bubbles from small liquid volumes. We address the common instabilities that develop in flow loops owing exclusively to the two-phase nature of the flow, e.g., Ledinegg instability and concentration waves. Finally we briefly review flow metering and gauging; two-phase flow through porous media, where pressure drop and flow regime map correlations in zero-g are a current research topic; and basic operation principles of heat pipes and capillary pumped loops.
The load profile for domestic water heating is time-dependent and can result in high energy demand during peak operating times. Shifting this peak load can have significant environmental and economic impacts. Phase change material (PCM)-based thermal energy storage (TES) is a potentially useful technology for peak load shifting in domestic hot water (DHW) applications thanks to its high latent heat and energy density. In this study, an annular finned-tube PCM-HX design concept was optimized for a load-shifting TES unit to meet the Department of Energy standard for a medium-usage DHW heater using a resistance-capacitance model (RCM) integrated with a Multi-Objective Genetic Algorithm. The optimized design comprised 70 identical annular finned-tube PCM-HX units connected in parallel and utilizing RT62HC as the PCM. A single PCM-HX unit was prototyped and tested in a vertically oriented setup with upward heat transfer fluid (HTF) flow. The hot water supply time was defined based on a cutoff temperature of 51.7°C. The as-designed mass flow rate (1.5 g/s) was tested to assess the performance of the prototyped PCM-HX unit for RCM validation. For the experimental investigation, RTD sensor bundles measured HTF temperature at the PCM-HX inlet and outlet, and a Coriolis flow meter accurately measured the HTF mass flow rate. The simulated discharging power underpredicted the experimental result by about 12%, and the simulated hot water supply time underpredicted the experimental result by approximately 13% for the as-designed mass flow rate (1.5 g/s). The average deviation of the hot water supply temperature between the experimental and RCM results during the complete PCM solidification process was 1.3 K for the as-designed mass flow rate. The overall good agreement between the experimental and RCM results provides confidence that computationally efficient models such as RCM can be utilized for design optimization of PCM-HXs.
Simulation of liquid-hydrogen turbine-type flow meter calibrations using high-pressure nitrogen gas at liquid-hydrogen density
Turbine flow meters dynamic calibration employing sinusoidally perturbed orifice flow
Pressure drop experiments in highly turbulent He II flow were performed in flow loops driven by either a centrifugal pump or a single-stroke bellows pump. Pressure drops in straight tubing, coiled tubing, bellows sections, valves and Venturi flow meters were measured over a range of flow rates and temperatures. Our pressure drop data are in general agreement with classical fluid correlations when the He II normal component viscosity is used in calculating the Reynolds number. Cavitation and, in some cases, metastable superheating were observed in pressure drop measurements with Venturis in both centrifugal and bellows pump flow circuits.
Quantification of flow with pulsed-wave Doppler assumes a "flat" velocity profile in the left ventricular outflow tract (LVOT), which observation refutes. Recent development of real-time, three-dimensional (3-D) color Doppler allows one to obtain an entire cross-sectional velocity distribution of the LVOT, which is not possible using conventional 2-D echo. In an animal experiment, the cross-sectional color Doppler images of the LVOT at peak systole were derived and digitally transferred to a computer to visualize and quantify spatial velocity distributions and peak flow rates. Markedly skewed profiles, with higher velocities toward the septum, were consistently observed. Reference peak flow rates by electromagnetic flow meter correlated well with 3-D peak flow rates (r = 0.94), but with an anticipated underestimation. Real-time 3-D color Doppler echocardiography was capable of determining cross-sectional velocity distributions and peak flow rates, demonstrating the utility of this new method for better understanding and quantifying blood flow phenomena.
This research article explores the behavior of a phase change material (PCM) when it undergoes interrupted melting and freezing, through experimental investigations using a heat flow meter apparatus. A fatty acid-based organic PCM, encapsulated within polyethylene and thin aluminum foil layers, was experimentally tested in this study. Experiments were designed to represent multiple interrupted phase change scenarios that could occur within PCMs applied in buildings. The experimental results were analyzed and compared with previously reported assumptions in numerical models dealing with PCM hysteresis and interrupted phase change processes. These comparisons indicated that the assumptions used in the different numerical models considered can capture the interrupted phase change phenomena with varying degrees of accuracy. The findings also highlighted the need for additional experimental research on different phase change processes that can occur in building applications of PCMs.
This article presents combined measurements of fatty acid-based organic PCM products and numerical simulations to evaluate the energy benefits of adding a PCM layer to an exterior wall. The thermal storage characteristics of the PCM were measured using a heat flow meter apparatus (HFMA). The PCM characterization is based on a recent ASTM International standard test method, ASTM C1784. The PCM samples were subjected to step changes in temperature and allowed to stabilize at each temperature. By measuring the heat absorbed or released by the PCM, the temperature-dependent enthalpy functions for melting and freezing were determined.Here, the simulations were done using a previously-validated two-dimensional (2D) wall model containing a PCM layer and incorporating the HFMA-measured enthalpy functions. The wall model was modified to include the hysteresis phenomenon observed in PCMs, which is reflected in different melting and freezing temperatures of the PCM. Simulations were done with a single enthalpy curve based on the PCM melting tests, both melting and freezing enthalpy curves, and with different degrees of hysteresis between the melting and freezing curves. Significant differences were observed between the thermal performances of the modeled wall with the PCM layer under the different scenarios.