At least 127 records · Page 7

Edge turbulence velocity preceding the L-H transition in NSTX

The low-to-high mode or L-H transition in tokamaks involves a sudden reduction in the edge turbulence level and decrease in the edge plasma transport. The mechanism for the L-H transition is widely believed to be associated changes in the the poloidal velocity of the edge turbulence. Using a gas puff imaging (GPI) diagnostic, the poloidally averaged poloidal turbulence velocity < V pol > pol was measured for a set of 16 shots with L-H transitions in NSTX. These measurements were focused -2 cm inside the separatrix where the relative fluctuation level as seen in GPI decreases significantly and consistently at the transition. Herein, the magnitude of this poloidal velocity preceding the transition varied widely, ranging from |V pol | ~1-4 km/sec during the last 1 msec before the transition, and the magnitude of the radial gradient also had a wide shot-to-shot range of |grad V pol | ~ 0.34 to 1.9 km/sec/cm during this same time. The frequency spectrum of < V pol > pol during the 30 msec before the transition had a near-coherent peak at ~2-5 kHz, but only in about half of these shots. In general, there were no clear and consistent changes in the poloidal velocity of the turbulence preceding the L-H transition in this database.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-power non-perturbative laser delivery diagnostics at the final focus of 100-TW-class laser pulses

Controlling the delivery of multi-terawatt and petawatt laser pulses to final focus, both in position and angle, is critical to many laser applications such as optical guiding, laser–plasma acceleration, and laser-produced secondary radiation. We present an online, non-destructive laser diagnostic, capable of measuring the transverse position and pointing angle at focus. The diagnostic is based on a unique double-surface-coated wedged-mirror design for the final steering optic in the laser line, producing a witness beam highly correlated with the main beam. By propagating low-power kilohertz pulses to focus, we observed spectra of focus position and pointing angle fluctuations dominated by frequencies below 70 Hz. The setup was also used to characterize the excellent position and pointing angle correlation of the 1 Hz high-power laser pulses to this low-power kilohertz pulse train, opening a promising path to fast non-perturbative feedback concepts even on few-hertz-class high-power laser systems.

47 OTHER INSTRUMENTATION↗

Investigation of neutron noise in a micro-scale, natural circulation molten salt fission battery system

The Molten Salt Reactor (MSR) concept is a rapidly evolving Generation IV design that has recently attracted favorable attention due to the potential for reducing waste generation, realizing passive safety features, and seizing on the opportunity for cost effective economics. A specific novel micro-MSR, natural circulation, battery design concept involves placing all primary components within a single reactor vessel containment without the need of primary forced pumping. This small modular, integral design presents potential cost savings while producing safety, reliable, and transportable carbon-free power for decades. This investigation evaluates the neutron noise induced by density and flow fluctuations in a natural circulation MSR battery concept being developed at the University of Idaho. This study finds numerical solutions to the one-dimensional, one-group, coupled diffusion equations for a bare, homogeneous core, and evaluates neutron flux and delayed neutron precursor concentration noise due to core flow and fuel salt density perturbation sources. Noise analysis shows both point kinetic and space-dependent behavior is present despite the small size, low-flow, closely-coupled nature of the natural circulation MSR concept. Analysis shows that the low flow of the convective system results in noise behavior typically representative of a larger forced-circulation MSR system. Finally, noise techniques may also be useful in MSR core diagnostics as a non-invasive, low-cost radiological option to traditional monitoring schemes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fluctuations and Self-Organization in Plasma Boundary Layers (Final Report)

Final technical report on an experimental study of the boundary of an ionized gas (plasma) where it interacts with solid surfaces. The plasma self-organizes into a sheath which experiences plasma flow and is naturally unstable to various fluctuations which can be observed with advanced laser-spectroscopy techniques.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-speed volumetric imaging of formaldehyde in a lifted turbulent jet flame using an acousto-optic deflector

The development of high-speed volumetric laser-induced fluorescence measurements of formaldehyde (CH 2 O-LIF) using a pulse-burst laser operated at a repetition rate of 100 kHz is presented here. A novel laser scanning system employing an acousto-optic deflector (AOD) enables quasi-4D CH 2 O-LIF imaging at a scan frequency of 10 kHz. The diagnostic capability of time-resolved volumetric imaging is demonstrated in a partially premixed DME/air lifted turbulent jet flame near the flame base. Simultaneous imaging of laser beam profiles is performed to account for the laser pulse energy fluctuation and laser sheet inhomogeneity. With the accurate registration of laser sheet positions, the volumetric reconstruction of CH 2 O-LIF signals is performed within a detection volume of 17.3 × 11.9 × 2.3 mm 3 with an average out-of-plane spatial resolution of 250μm. A surface detection algorithm with adaptive thresholding is used to determine the global maximum intensity gradient by calculating gradient percentiles. The flame topology characteristics are investigated by evaluating the 3D curvatures of CH 2 O surfaces. Curvatures calculated using 2D data systematically underestimate the full 3D curvature due to the lack of out-of-plane information. The inner surfaces near the turbulent fuel jet exhibit higher probabilities of large mean curvature than the outer surfaces. The saddle and cylindrical structures are dominant on both the inner and outer surfaces and the elliptic structures occur with lower probability. The results suggest that the damping of turbulent fluctuations by the temperature increase through the CH 2 O region reduces the curvature, but the local structure topology remains self-similar.

42 ENGINEERING↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Injection, confinement, and diagnosis of electrons and positrons in a permanent magnet dipole trap

Abstract Prerequisites for the goal of studying long-lived, magnetically confined, electron–positron pair plasmas in the laboratory include the injection of both species into the trap, long trapping times, and suitable diagnostic methods. Here we report recent progress on these tasks achieved in a simple dipole trap based on a supported permanent magnet. For the injection of electrons, both an $$\textbf{E}\times B$$ E × B drift technique (of a $$\sim $$ ∼ 2– $$\upmu $$ μ A, 6-eV beam) and “edge injection” (from a filament emitting a few mA and biased to some tens of volts) have been demonstrated; the former is suitable for low-density beams with smaller spatial and velocity spreads, while the latter employs fluctuations arising from collective behavior. To diagnose the edge-injected electrons, image potentials and currents induced on a wall probe, the magnet case, and wall electrodes were measured. Confinement of drift-injected positrons, measured experimentally, exhibited at least two well-separated timescales. Simulations reproduced this qualitatively, using a simple model of elastic collisions with residual background gas, and point to small adjustments for increasing trapping times. In a major upgrade to diagnostic capabilities, 25 bismuth germanate detectors, placed in three reentrant ports, are able to localize annihilation gammas, which will be used in future experiments to distinguish between different loss channels. Graphical abstract

von der Linden, J. (ORCID:0000000327477813)↗

The Impact of Operational Strategies and Load Fluctuations on Anion Exchange Membrane Water Electrolyzer Degradation

This study reports on the durability of anion exchange membrane water electrolyzers (AEMWEs) at the cell level in a supporting electrolyte (1 M) and the impact of operational profiles on cell degradation. While constant load shows significant voltage loss, including a current hold at 1 A cm −2 and a potential hold at 2 V, it generally occurs in the first 70 h of testing. These losses are likely due to passivation altering site reactivity and cell kinetics, and are largely recoverable upon load cycling and diagnostics at the end of test. Furthermore, square and triangular-wave cycling do not show cell degradation and indicate that AEMWEs are not vulnerable to load cycling. When operating outside of this potential window (1.45–2 V), cell voltage decay rates markedly increase and the losses are not recoverable. This includes a current density hold at 4.0 A cm −2 with high cell voltages (>2.4 V for test duration) and cycling between 0 and 2 V to simulate start–stop, where more than a 50% loss in current density occurs over 50 h. The findings presented here demonstrate the high durability of AEMWEs, particularly when operating with load fluctuations, and may allow for durability advantages compared to iridium and proton exchange membrane systems.

08 HYDROGEN↗

Extending the low-recycling, flat temperature profile regime in the lithium tokamak experiment-β (LTX-β) with ohmic and neutral beam heating

Abstract Recent experiments in the lithium tokamak experiment- β (LTX- β ) have extended the duration, performance, operating conditions, and diagnosis of the flat-temperature profile, low-recycling regime first observed in LTX. As expected, Li retains hydrogen and suppresses edge neutral cooling, allowing increased edge electron temperature, roughly equal to the core T e . Flat temperature profiles had been obtained transiently in LTX, as the plasma density decayed following the cessation of edge gas puffing. Careful control over the fueling in LTX- β has now been shown to sustain the flat T e profile and hot edge unique to the low-recycling regime for multiple confinement times in high performance discharges with decaying or steady density. With low density, the flat T e profile is also seen to extend into the scrape-off layer. Neutral beam heating is observed in target discharges with relatively flat electron temperature profiles ( T edge ∼ T core /2), though beam heating is stronger in discharges with higher fueling, higher density, and depressed edge T e . Beam heating produces additional peaking of the T e profile, without degradation of the energy confinement time. Neutral beam heating of target discharges with relatively flat electron temperature profiles similarly results in broad beam heated temperature profiles. Energy confinement in LTX- β generally compares favorably to ohmic and H-mode scalings, frequently exceeding them by factors of 2–4. New and improved diagnostics in LTX- β enable better characterization of this unique regime, including measurements of ion temperature and high field side Thomson scattering profiles. As an initial step toward characterizing turbulence with no T e gradient and roughly equal density and pressure gradient, core fluctuation spectra have been measured in peaked T e discharges using far-forward scattering and fluctuation reflectometry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ghost-imaging-enhanced noninvasive spectral characterization of stochastic x-ray free-electron-laser pulses

Abstract High-intensity ultrashort X-ray free-electron laser (XFEL) pulses are revolutionizing the study of fundamental nonlinear x-ray matter interactions and coupled electronic and nuclear dynamics. To fully exploit the potential of this powerful tool for advanced x-ray spectroscopies, a noninvasive spectral characterization of incident stochastic XFEL pulses with high resolution is a key requirement. Here we present a methodology that combines high-acceptance angle-resolved photoelectron time-of-flight spectroscopy and ghost imaging to enhance the quality of spectral characterization of x-ray free-electron laser pulses. Implementation of this noninvasive high-resolution x-ray diagnostic can greatly benefit the ultrafast x-ray spectroscopy community by functioning as a transparent beamsplitter for applications such as transient absorption spectroscopy in averaging mode as well as covariance-based x-ray nonlinear spectroscopies in single-shot mode where the shot-to-shot fluctuations inherent to a self-amplified spontaneous emission (SASE) XFEL pulse are a powerful asset.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First application of a digital mirror Langmuir probe for real-time plasma diagnosis

For the first time, a digital Mirror Langmuir probe (MLP) has successfully sampled plasma temperature, ion saturation current, and floating potential together on a single probe tip in real time in a radio-frequency driven helicon linear plasma device. This is accomplished by feedback control of the bias sweep to ensure a good fit to I-V characteristics with a high frequency, high power digital amplifier and field-programmable gate array (FPGA) controller. Measurements taken by the MLP were validated by a low speed I-V characteristic manually collected during static plasma conditions. Plasma fluctuations, induced by varying the axial magnetic field (f̃ = 10 Hz), were also successfully monitored with the MLP. Further refinement of the digital MLP pushes it towards a turn-key system that minimizes the time to deployment and lessens the learning curve, positioning the digital MLP as a capable diagnostic for the study of low radio-frequency plasma physics. These demonstrations bolster confidence in fielding such digital MLP diagnostics in magnetic confinement experiments with high spatial and adequate temporal resolution such as edge plasma, scrape-off layer, and divertor probes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Realization of a gas puff imaging system on the Wendelstein 7-X stellarator

A system for studying the spatiotemporal dynamics of fluctuations in the boundary of the W7-X plasma using the “Gas-Puff Imaging” (GPI) technique has been designed, constructed, installed, and operated. This GPI system addresses a number of challenges specific to long-pulse superconducting devices, such as W7-X, including the long distance between the plasma and the vacuum vessel wall, the long distance between the plasma and diagnostic ports, the range of last closed flux surface (LCFS) locations for different magnetic configurations in W7-X, and management of heat loads on the system’s plasma-facing components. The system features a pair of “converging–diverging” nozzles for partially collimating the gas puffed locally ≈135 mm radially outboard of the plasma boundary, a pop-up turning mirror for viewing the gas puff emission from the side (which also acts as a shutter for the re-entrant vacuum window), and a high-throughput optical system that collects visible emission resulting from the interaction between the puffed gas and the plasma and directs it along a water-cooled re-entrant tube directly onto the 8 × 16 pixel detector array of the fast camera. The DEGAS 2 neutral code was used to simulate the Hα (656 nm) and HeI (587 nm) line emission expected from well-characterized gas-puffs of H2 and He and excited within typical edge plasma profiles in W7-X, thereby predicting line brightnesses used to reduce the risks associated with system sensitivity and placement of the field of view. Operation of GPI on W7-X shows excellent signal-to-noise ratios (>100 at 2 Mframes/s) over the field of view for minimally perturbing gas puffs. The GPI system provides detailed measurements of the two-dimensional (radial and poloidal) dynamics of plasma fluctuations in the W7-X edge and scrape-off layer and in and around the magnetic islands outside the LCFS that make up the island divertor configuration employed on W7-X.

Instruments & Instrumentation↗

First application of a digital mirror Langmuir probe for real-time plasma diagnosis

We report for the first time, a digital Mirror Langmuir Probe (MLP) has successfully sampled plasma temperature, ion saturation current, and floating potential together on a single probe tip in real time in a radio-frequency driven helicon linear plasma device. This is accomplished by feedback control of the bias sweep to ensure a good fit to I–V characteristics with a high frequency, high power digital amplifier, and field-programmable gate array controller. Measurements taken by the MLP were validated by a low speed I–V characteristic manually collected during static plasma conditions. Plasma fluctuations, induced by varying the axial magnetic field($\widetilde{f}$ = 10 Hz), were also successfully monitored with the MLP. Further refinement of the digital MLP pushes it toward a turn-key system that minimizes the time to deployment and lessens the learning curve, positioning the digital MLP as a capable diagnostic for the study of low radio-frequency plasma physics. These demonstrations bolster confidence in fielding such digital MLP diagnostics in magnetic confinement experiments with high spatial and adequate temporal resolution, such as edge plasma, scrape-off layer, and divertor probes.

47 OTHER INSTRUMENTATION↗

Inertial dynamics of an interface with interfacial mass flux: Stability and flow fields’ structure, inertial stabilization mechanism, degeneracy of Landau’s solution, effect of energy fluctuations, and chemistry-induced instabilities

This work focuses on the long-standing problem of inertial dynamics of an interface with interfacial mass flux and reports new mechanisms for the interface stabilization and destabilization. The interface is a phase boundary separating fluids of different densities and having interfacial mass flux. To analyze the interface dynamics from a far field, we develop and apply the general matrix method to rigorously solve the boundary value problem involving the governing equations in the fluid bulk and the boundary conditions at the interface and at the outside boundaries of the domain. We find the fundamental solutions for the linearized system of equations and analyze the interplay of interface stability with flow fields’ structure by directly linking rigorous mathematical attributes to physical observables. We find that the interface is stable when the dynamics conserves the fluxes of mass, momentum, and energy; the stabilization is due to an inertial mechanism causing small oscillations of the interface velocity. In the classic Landau’s dynamics, the postulate of perfect constancy of the interface velocity leads to the development of Landau–Darrieus instability. This destabilization is also linked to the imbalance of the perturbed energy at the interface. The classic Landau’s solution is found to have degeneracy; lifting of the degeneracy may lead to singularity and self-similar dynamics. Our results compare well with traditional theories of combustion and propose new experiments to study the dynamics of the interface and the flow fields in combustible systems. We further conduct reactive molecular dynamics simulations to elucidate the complexity of chemical processes, to study the destabilizing effect of energy fluctuations on the interface stability, and to illustrate the chemistry-induced instabilities. In summary, we identify the extreme sensitivity of the interface dynamics to the interfacial boundary conditions, including the formal properties of fundamental solutions and the qualitative and quantitative properties of the flow fields. This provides new opportunities for studies, diagnostics, and control of multiphase flows in a broad range of processes in nature and technology.

42 ENGINEERING↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solar Wind Turbulence from 1 to 45 au. I. Evidence for Dissipation of Magnetic Fluctuations Using Voyager and ACE Observations

As part of a published effort to study low-frequency magnetic waves excited by newborn interstellar pickup ions seen by the Voyager spacecraft, we developed a set of control intervals that represent the background turbulence when the observations are not dominated by wave excitation. This paper begins an effort to better understand solar wind turbulence from 1 to 45 au while spanning greater than one solar cycle. Here, we first focus on the diagnostics marking the onset of dissipation. This includes an expected break in the power spectrum at frequencies greater than the proton cyclotron frequency and a resultant steepening of the spectrum at higher frequencies. Contrary to what is established at 1 au, we only see the spectral break in rare instances. The expected scaling of the spectral index with the turbulence rate is seen, but it is not as clearly established as it was at 1 au. We also find that both Voyager data from 1 to 45 au and Advanced Composition Explorer data from 1 au show significant bias of the magnetic helicity at dissipation scales when the dissipation-range power-law spectral index steepens. We conclude that dissipation dynamics are similar throughout the heliosphere in so far as we have examined to date.

Pine, Zackary B.↗

Dark Energy Survey Year 3 Results: Measuring the Survey Transfer Function with Balrog

Abstract We describe an updated calibration and diagnostic framework, Balrog , used to directly sample the selection and photometric biases of the Dark Energy Survey (DES) Year 3 (Y3) data set. We systematically inject onto the single-epoch images of a random 20% subset of the DES footprint an ensemble of nearly 30 million realistic galaxy models derived from DES Deep Field observations. These augmented images are analyzed in parallel with the original data to automatically inherit measurement systematics that are often too difficult to capture with generative models. The resulting object catalog is a Monte Carlo sampling of the DES transfer function and is used as a powerful diagnostic and calibration tool for a variety of DES Y3 science, particularly for the calibration of the photometric redshifts of distant “source” galaxies and magnification biases of nearer “lens” galaxies. The recovered Balrog injections are shown to closely match the photometric property distributions of the Y3 GOLD catalog, particularly in color, and capture the number density fluctuations from observing conditions of the real data within 1% for a typical galaxy sample. We find that Y3 colors are extremely well calibrated, typically within ∼1–8 mmag, but for a small subset of objects, we detect significant magnitude biases correlated with large overestimates of the injected object size due to proximity effects and blending. We discuss approaches to extend the current methodology to capture more aspects of the transfer function and reach full coverage of the survey footprint for future analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

No Galaxy Left Behind: Measuring the Transfer Function of the Dark Energy Survey with Balrog

In this dissertation, we describe a calibration and diagnostic framework called Balrog which was used to directly sample the selection and photometric biases of the Dark Energy Survey (DES) Year 3 (Y3) dataset. We systematically inject onto the single-epoch images of a random 20% subset of the DES footprint an ensemble of nearly 30 million realistic galaxy models derived from DES Deep Field observations. These augmented images are analyzed in parallel with the original data to automatically inherit measurement systematics that are often too difficult to capture with traditional generative models. The resulting object catalog is a Monte Carlo sampling of the DES transfer function and is used as a powerful diagnostic and calibration tool for a variety of DES Y3 science, particularly for the calibration of the photometric redshifts of distant "source" galaxies and magnification biases of nearer "lens" galaxies. The recovered Balrog injections are shown to closely match the photometric property distributions of the fiducial Y3 GOLD catalog, particularly in color, and capture the number density fluctuations from observing conditions of the real data within 1% for a typical galaxy sample. We find that Y3 colors are extremely well calibrated, typically within ~1-8 millimagnitudes, but for a small subset of objects we detect significant magnitude biases correlated with large overestimates of the injected object size due to proximity effects and blending. Finally, we discuss approaches to extend the current methodology to capture more aspects of the transfer function for future analyses.

79 ASTRONOMY AND ASTROPHYSICS↗