Search NASA⌕ Search

SEARCH · Search NASA

Results for “flue gas capture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Improving the Economic Viability of Biological Utilization of Coal Power Plant CO 2 by Improved Algae Productivity and Integration with Wastewater Treatment

The overall goal of this project was to improve the cost-effectiveness of systems using algae to capture and beneficially utilize CO 2 from the flue gas of coal-fired power plants. Algal biomass cultivation is an attractive alternative for carbon capture and utilization because it can uptake more CO 2 per land area than any other photosynthetic crop. Also, the resulting biomass can be used to make valuable large-market commodity products, such as biofuels and animal feed. However, the use of algal carbon capture has been limited by several factors including: (1) high costs for growing algae (>$\$1,300$/ton), (2) large land requirements for algae cultivation, and (3) environmental concerns about the large amount of water and nutrient inputs needed for growing algae. This project has taken direct aim at resolving these key limitations and demonstrated several viable approaches to improve the economic and environmental feasibility of algal carbon capture. In particular, this project demonstrated a significant increase in average annual algal productivity from baseline values of 8 g/m 2 -day to above 20 g/m 2 -day. This supports a much lower projected cost of algae production (<$\$500$/ton) and reduces land requirements by more than 50%. Additionally, this project confirmed the ability to grow multiple algae species with wastewater nutrients, which facilitates the potential for substantial new revenue streams for algae cultivation based on tipping fees for nutrient laden wastewater. This study highlighted that there is more potential value in wastewater nutrient treatment credits than in the primary commodity products made from algae. The use of wastewater inputs also mitigates the concerns associated with the large amount of water needed for growing algae. The algal biomass grown for this project using wastewater and simulated flue gas inputs were characterized for potential use as an animal feed ingredient. The algae had a protein content in the range of 35-40%, which is between some common commodity animal feed products— distiller’s grains (~25-30% protein) and soybean meal (45-50% protein). In-vitro digestion tests using cattle rumen fluids, showed that this algae biomass was best suited for use as “bypass protein”, which is digested in the animal intestine. Based on the protein content and amino acid profile of the algae grown in this study, it was estimated to have market value in the range of $\$190$-$\$280$/ton. There is potential for higher value feed products if the algae content of omega-3 fatty acids or antioxidants is accounted for. This project also did small scale demonstration of forward osmosis algae dewatering and nanofiltration of hydrothermal liquefaction aqueous products, which were shown to improve the cost and energy balance for producing algal products. When all the improvements demonstrated in this study were included in techno-economic analysis, it showed there was a viable pathway to profitable algal CO 2 utilization with a payback period in the range of six to ten years.

01 COAL, LIGNITE, AND PEAT↗

Polyamine phosphorus dendrimer materials for carbon dioxide capture

The present disclosure provides novel solid sorbents synthesized by the reaction of polyamines with polyaldehyde phosphorous dendrimer (P-dendrimer) compounds. The sorbents are highly stable and exhibit rapid reaction kinetics with carbon dioxide, making the sorbents applicable for carbon capture, and can be easily regenerated for further use. The material is stable to aqueous and organic media, as well as strong acid and bases. The sorbent maintains full capacity over extended use. The material can be used for CO2 capture from pure CO2 streams, mixed gas streams, simulated flue gas, and ambient air. Additionally, the material can be adhered to surfaces for reversible CO2 capture applications outside of bulk particle-based processes.

Thompson, III, Samuel John↗

SECARB 2020 Semi-Annual Field Review Reports - Anthropogenic Test

The Southern States Energy Board (SSEB) managed the overall Southeast Regional Carbon Sequestration Partnership (SECARB) Phase III project and the Electric Power Research Institute (EPRI) managed all activities associated with the Anthropogenic Test site. Advanced Resources International, Inc. (ARI) assisted EPRI with the management of site activities. EPRI and ARI followed reporting procedures that included monthly and quarterly technical progress reports, as well as periodic reporting on key field activities. Subsequent sections of this report catalog the field activities and are organized in a semi-annual chronology. The SECARB Anthropogenic Test was the largest demonstration of a fully integrated, pulverized coal-fueled carbon capture and storage (CCS) project in the United States as of 2012 and supports a commercial prototype of CO 2 capture; transportation; subsurface storage; and monitoring, verification, and accounting (MVA); and assessment. The demonstration-scale, post-combustion CO 2 capture facility at Alabama Power Company’s Plant Barry diverted flue gas (25MW equivalent) from its Unit #5 coal burning facility and captured the CO 2 using Mitsubishi Heavy Industries (MHI) KM-CDRTM advanced amine technology. The captured CO2 was compressed at Plant Barry and transported by pipeline to the injection location southeast of Citronelle, Alabama. The Citronelle Project’s geologic storage and MVA sites were located on the flanks of the Citronelle Dome, approximately three miles southeast of the city of Citronelle. The injection zone, the Paluxy Formation, a saline formation that occurs at approximately 9,400 feet and overlies the oil production horizon of the Citronelle oilfield, presents a favorable injection reservoir in terms of areal extent and petrophysical characteristics. The confining zone, the basal shale of the overlying Washita-Fredericksburg Formation, is persistent throughout the Citronelle area and possesses the appropriate criteria to act as an effective CO 2 seal.

01 COAL, LIGNITE, AND PEAT↗

Negative Charge Confined Amine Carriers within the Nanowire Network for Stable and Efficient Membrane Carbon Capture

Membrane-based carbon dioxide (CO 2 ) capture has attracted great research interest owing to its potential for higher separation efficiency and lower energy consumption. However, it is still a challenging task to capture CO 2 with membrane from flue gas, especially under moderate-temperature and high-humidity conditions. Here, a stable CO 2 -selective membrane that can operate at temperatures up to 90 °C and under high humidity is reported. The positively charged amine carriers for CO 2 are confined within the negatively charged polymer modified carbon nanotube (CNT) network. In this structure, interconnected CNTs act as the framework for the selective layer and provide numerous nanochannels for gas transport. The negatively charged polymer ensures the carrier stability and further regulates the size of nanochannels in the CNT network. By virtue of carrier-facilitated transport, high CO 2 permeance (up to 3300 gas permeation units) and high CO 2 /N 2 selectivity (400) are achieved under simulated flue gas conditions. Moreover, theoretical calculations verify that the stable separation performance is due to the strong electrostatic interaction between the amine carriers and polymer matrix. The high performance and good stability indicate the great potential of this novel membrane structure for practical application in CO 2 capture.

36 MATERIALS SCIENCE↗

Quantifying Climate Change Effects of Bioenergy and BECCS: Critical Considerations and Guidance on Methodology

Bioenergy is a critical element in many national and international climate change mitigation efforts, including as a carbon dioxide removal strategy combined with the capture and durable geological storage of flue gas emissions (BECCS). However, divergent results on the effectiveness of bioenergy as a climate change mitigation measure are reported in the scientific literature. Climate impacts of bioenergy depend on case-specific factors, primarily biophysical features of the biomass production system, and the design and efficiency of conversion and capture processes. Estimates of climate impacts are also strongly affected by methodological choices and assumptions, and much of the divergence between studies derives from differences in the assumed alternate use of the land or feedstock, the alternate energy source and the system boundaries applied. We present a methodology to support robust estimates of the climate change effects of bioenergy systems, updating the standard methodology developed by the International Energy Agency's Technology Collaboration Program on Bioenergy. We provide guidance on the key choices including the reference land use and energy system that bioenergy is assumed to displace, spatial and temporal system boundaries, co-product handling, climate forcers considered, metrics applied and time horizon of impact assessment. Researchers should consider the whole bioenergy system including all life cycle stages, and choose system boundaries, reference systems and treatment of co-products that are consistent with the intended application of the results. The assessment should be normalised to a functional unit that can be compared with other systems delivering an equivalent quantity of the same function. All significant climate forcers should be included, and climate effects should be quantified using appropriate impact assessment methods that distinguish the impact of time. Consistency in methodology and interpretation will facilitate comparison between studies of different bioenergy systems.

09 BIOMASS FUELS↗

W.A. Parish Post-Combustion CO 2 Capture and Sequestration Demonstration Project (Final Technical Report)

The Petra Nova Project (Project) is a commercial scale post-combustion carbon capture project developed by a joint venture between NRG Energy, Inc. (NRG) and JX Nippon Oil Exploration (EOR) Limited (JX). The Project is designed to separate and capture carbon dioxide (CO2) from an existing coal-fired unit’s flue gas slipstream at NRG’s W.A. Parish Electric Generating Station (WAP) located southwest of Houston, Texas. The captured CO2 is dried, compressed, and transported via an 81-mile pipeline to the West Ranch oilfield (West Ranch) in Jackson County, Texas, where it is injected to boost oil production. The Project, which is partially funded by a grant (Grant) from the United States (U.S.) Department of Energy (DOE) under the Clean Coal Power Initiative (CCPI) Round 3, uses the Kansai Mitsubishi Carbon Dioxide Recovery advanced amine-based CO 2 absorption technology (KM-CDR Process®), which was jointly developed by Mitsubishi Heavy Industries, Ltd. (MHI) and the Kansai Electric Power Co. Inc., to treat and capture at least ninety percent (90%) of the CO 2 from a 240-megawatt equivalent (MWe) flue gas slipstream off of Unit 8 at WAP. When operating at full capacity, the Project captures approximately 5,200 short tons of CO 2 per day, which would otherwise be emitted into the atmosphere, representing the largest commercial scale deployment of post-combustion CO2 capture technology at a coal power plant to date. Under the Grant, the Project was managed in 3 phases: (1) Phase 1: Project Definition / Front End Engineering Design (FEED) (2) Phase 2: Detailed Engineering, Procurement & Construction (3) Phase 3: Demonstration and Monitoring. On December 29, 2016, commercial operation of the Project was achieved, ending Phase 2 and starting Phase 3, a 3-year demonstration period running from January 1, 2017 through December 31, 2019. The key objectives of Phase 3 were to (a) demonstrate the specific advanced technologies constructed during Phase 2 and (b) monitor the injected CO 2 at West Ranch to demonstrate technologies and protocols for monitoring, verification, and accounting (MVA). As of the end of Phase 3, Petra Nova captured 3,904,978 short tons of CO 2 (3,542,537 metric tons) that was transported to West Ranch. To support the DOE obligation to monitor, verify, and account for the sequestered CO 2 at West Ranch, Petra Nova contracted with the Bureau of Economic Geology (in the Jackson School of Geosciences at The University of Texas at Austin) to (a) design a monitoring program, (b) draft an MVA Plan for DOE review and approval, and (c) working with Petra Nova and the operator of West Ranch to manage and report on the MVA activity. This report discussed the technical aspects of the project during each of the 3 phases of the project as identified above.

01 COAL, LIGNITE, AND PEAT↗

Direct Air Capture of CO 2 and Delivery to Photobioreactors for Algal Biofuel Production (Final Report)

A mobile DAC system was designed and constructed to pair with photobioreactors growing algae for biofuel production. The DAC system was designed as a versatile research system, rather than a compact production unit. The system was constructed and mounted on a mobile skid to facilitate transportation to the algae production site. Within the DAC system, CO 2 was captured using amine-loaded monoliths that allow for high CO 2 uptake with low pressure drop. The CO 2 is collected using a Global Thermostat patented temperature/vacuum swing adsorption (TVSA) process. Amine sorbents and process conditions were optimized to produce 10 to >20 g CO 2 .h-1. The stability of the amine sorbents was also studied, with sorbent modifications made to improve stability to degradation by oxidation. An Algenol-developed Spirulina strain (Arthrospira platensis AB2293) was selected as the production cyanobacterial strain. AB2293 cultured was inoculum for outdoor production following PBR installation by Algenol. The PBR system was composed of three independent PBRs, with each PBR composed of four hanging bags internally recirculated by a liquid turnover pump. The PBRs were operated outdoors in Atlanta, GA, and integrated with the DAC system. Algae were grown with similar productivity using DAC-CO 2 as algae grown using pure CO 2 obtained commercially (Airgas). Throughout the experimental duration, no discoloration was observed, and cellular morphology was consistent between the two experimental treatments. An LCA including lifecycle greenhouse gas emissions, full life cycle inventory of the Algenol system and the DAC system and integrated DAC+PBR system was developed. Lifecycle greenhouse gas emissions were calculated for capture of carbon dioxide using input from Global Thermostat and the National Renewable Energy Laboratory. Three scenarios for energy provision were evaluated: a natural gas combined heat and power system sized to meet the electricity requirement, a natural gas combined heat and power system sized to meet the process heat requirements, and a system without on-site power that procures the electricity from the grid. In all three cases, as expected, the major contributor to the emissions is the energy consumption associated with the desorption step of the DAC process. The LCA quantified the reduced potential energy and greenhouse gas emissions of heat and mass integration of DAC and Algenol compared to unintegrated DAC and Algenol systems. A life cycle assessment of the role of sorbent productivity and lifetime was also developed. The development of more robust, oxidation resistant DAC sorbents may enable small reductions in energy requirements and in lifecycle greenhouse gas emissions and other environmental impacts. NREL performed techno-economic analysis (TEA) to identify the integration scenario most likely to achieve a 15% cost reduction target versus the baseline. Heat and mass integration of DAC and the PBR is critical to minimizing the MFSP. The baseline case utilizes no heat and mass integration, and the DAC system provides 100% of the CO 2 required by the photobioreactors (20 tonnes/hr), operating for 12 hours/day capturing 40 tonnes CO 2 /operating hour. The minimum fuel selling price (MFSP) of ethanol calculated from the baseline case was $10.68/gal ethanol. This corresponds with a targeted MFSP of $9.07/gal ethanol (or 15% reduction). This target was achieved by integration Option 2a with the greatest cost reduction of 17.8% (or $8.78/gal) and integration Option 2b with a cost reduction of 16.4% (or $8.93/gal). Reductions in MFSP are attributed to two primary process considerations: (a) CO 2 storage at night reduces the capital expenses associated with DAC (i.e., increasing on-stream time); and (b) distributed DAC scenarios (DAC-PBR integration Options 2a and 2b) make use of boiler and DAC CHP flue gas CO 2 (free). Direct air capture on-stream time was one of the largest contributors to MFSP reduction.

09 BIOMASS FUELS↗

Carbon Capture and Utilization for Protein and Fatty Acids

The unlimited release version of the final report for the "Carbon Capture and Utilization for Protein and Fatty Acids" project. This project advanced an integrated open raceway algae cultivation and processing system to engineering scale for carbon capture and utilization (CCU) from the flue gas of a naphtha-fired power plant.

02 PETROLEUM↗

Membrane Development for CO2 Capture from Steel Manufacturing

The U.S. government is targeting a net-zero carbon-emission economy by 2050, offering an exciting opportunity for membrane-based CO2 capture from various industrial point sources. Given that industrial flue gas has low CO2 partial pressures and high volumetric flow rates, high-permeance membranes are needed to make membrane technology economically viable for large-scale deployment. Thin film composite (TFC) membranes are necessary for this implementation because they can provide high permeance by forming a thin selective layer on top of a porous support. This presentation will report the rational design and fabrication of NETL’s highly permeable non-aging TFCs achieved by: synthesizing a high-performance rubbery selective material; developing a high-porosity membrane support; optimizing coating methods to assemble the two materials into scalable membranes; and scaling up membrane supports and TFCs via a roll-to-roll process. The novel rubbery selective material shows mixed-gas CO2 permeability of 930 Barrer and CO2/N2 selectivity of 44, exceeding the 2008 Robeson upper bound. The resulting TFCs yield remarkably high CO2 permeance of 4,500 GPU and CO2/N2 selectivity of 34 at 23ºC. Moreover, the TFCs exhibit not only excellent performance stability (or non-aging behavior) for 1,000 hours in the lab, but also maintain their separation properties in a 700-hour field test at the U.S. DOE’s National Carbon Capture Center using real humid flue gas.

Tran, Thien↗

Corrigendum to “Cross-sectoral assessment of CO2 capture from U.S. industrial flue gases for fuels and chemicals manufacture” [International Journal of Greenhouse Gas Control 135 (2024) 1-20 / 104137]

The authors regret the inaccuracy in the vertical axis title of Fig. 4 and the distortion in the legend of Fig. 13. Corrections have been made to the vertical axis title and legend of Figs. 4 and 13, respectively. These changes do not affect the analysis, calculations, or results in any way. The authors apologize for any inconvenience caused. The corrected figures are as follows:

Zuberi, M Jibran S↗

A Novel Molten Salt System for CO 2 Based Oxidative Dehydrogenation with Integrated Carbon Capture (Final Technical Report)

The objective of this project was to develop a comprehensive proof-of-concept for sustainable and cost-effective production of propionic acid and value-added olefins from carbon dioxide (CO 2 ) in power plant flue gas and domestic shale gas resources. This was realized via a molten-salt-mediated oxidative dehydrogenation (MM-ODH) process that performs CO 2 capture (from power plant flue gas) and CO 2- assisted alkane oxidative dehydrogenation in a two-step, thermochemical scheme. The resulting carbon monoxide (CO) and light olefin (e.g., ethylene from ethane ODH) can be subsequently converted into propionic acid via the industrially proven hydrocarboxylation process.

20 FOSSIL-FUELED POWER PLANTS↗

Universal Solvent Viscosity Reduction via Hydrogen Bonding Disruptors

Liquid Ion Solutions LLC (DBA RoCo Global) in partnership with Carnegie Mellon University and Carbon Capture Scientific LLC, has performed lab-scale development and evaluation of novel additives that lower the viscosity of water-lean amine solvents for post-combustion carbon dioxide capture. This project focuses on developing additives that minimize the formation of long-range electrostatic and hydrogen bonding (HB) networks, decreasing the solvent viscosity, improving diffusion, and improving the process economics. The project objectives included: 1) performing computer simulation to understand the molecular interactions of the additive molecules in water-lean CO 2 capture solvents, 2) design and synthesis of HB disruptors additives, 3) performance testing with additive molecules on model amine solvents, and 4) demonstration of the effectiveness of the optimized additives in the presence of synthetic flue gas. To meet the abovementioned objectives, the project team utilized a holistic approach that combines molecular simulation, experimental testing, and economic analysis studies. The project team developed ab initio molecular model and then perform computer simulation to develop relationship between hydrogen bonding, viscosity, and performed quantitative analysis of additive on the viscosity of the solvent. The team completed computational comparative study on a range of organic functional groups such as ethers, esters, cyclic carbonates, alkanes, and ammonium salts for their effect on viscosity gaining key insights into molecular interactions and the impact of various functional groups and molecular shapes on viscosity. Assisted with molecular simulation insights, the project team conducted additive synthesis and testing, including a proof-of-concept study, additive screening, optimization, and synthetic flue gas testing. The experimental proof-of-concept study proved that the hydrogen bonding acceptors result in significant decrease of viscosities. Detailed additive screening (exploring various functionalities and molecular structures) has been performed. Several promising additives showed excellent reduction in viscosity (30-41%) at 5% additive loading, and over 50% viscosity reduction at 10% additive loading for the model solvents. The team also performed complex screening studies on additive loadings and mixing effect among additives using the design of experiments. Based on multiple screening experiments, one additive-solvent candidate was down-selected for synthetic flue gas testing. A 100-hour continuous absorption/desorption study was conducted under simulated flue gas using a lab-scale continuous capture and separation system. No degradation (for both solvent and additive) was observed based on the GC results of the solvent samples collected from the continuous study. The team conducted preliminary engineering analyses and cost-benefit analyses to quantify the potential economic benefits of the additive approach for solvent viscosity reduction. Based on the experimental data, CO 2 capture cost savings from the capital and operating cost savings are estimated at $\$$4.7/tonne and $\$$0.3/tonne CO 2 captured, respectively. Considering the additive cost, the net benefit is estimated to be between $\$$4.32~$\$$4.86/tonne CO 2 captured.

20 FOSSIL-FUELED POWER PLANTS↗

Understanding the performance of membrane for direct air capture of CO 2

Abstract Direct air capture (DAC) of CO 2 is becoming increasingly important for reducing greenhouse gas concentrations in the atmosphere. However, the cost and energy requirements associated with DAC make it less economically feasible than carbon capture from flue gases. While various methods like solid sorbents and gas–liquid absorption have been explored for DAC, membrane processes have only recently been investigated. The objective of this study is to examine the separation performance of a membrane unit for capturing CO 2 from ambient air. The performance of a membrane depends on several factors, including the composition of the feed gas, pressure ratio, material selectivity, and membrane area. The single‐stage separation process with the co‐current flow and constant permeability flux model is evaluated using a commercial module integrated with a process simulator to separate a binary mixture of carbon dioxide and nitrogen to assess the sensitivity of selectivity on purity and recovery of CO 2 in permeate, and power requirement. Additionally, three levels of CO 2 reduction from the feed stream to the retentate stream (25%, 50%, and 75%) are studied. A trade‐off between purity and recovery factor is observed, and achieving high purity in permeate requires high concentration in the retentate.

Panja, Palash↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Engineering-Scale Validation of Novel Algae CO 2 Capture and Bioproducts Technology

The purpose of this project was to advance and scale the algae-based technology Helios-NRG has been developing for capture of CO 2 from the flue gas of coal-burning power plants with conversion of the CO 2 to high-value products. In order to encourage the process becoming commercial and be adoptable, it is essential that the cost of CO 2 be close to net zero or slightly revenue positive. Two methods to achieve this are reducing the cost of operations through efficiencies and selling of products derived from conversion. Helios and the project team partners have accomplished the goals of furthering the technology to be more scalable and substantially lower cost with a defined pathway for commercialization.

01 COAL, LIGNITE, AND PEAT↗

Systems Analysis of Biomass and Coal Co-firing Power Plants with Deep Carbon Capture Toward Net-zero Emissions

Achieving a net-zero emission economy in the United States requires integrating diverse low-carbon and negative-emission technologies into the existing fossil fuel-dominant power fleet. Potential technologies from the low-carbon portfolio include renewable power, fossil power with carbon capture and storage (CCS), bioenergy with CCS (BECCS), and direct air capture (DAC). Renewable power is a clean energy source but has to pair with costly battery storage to provide dispatchable electricity. Fossil power with CCS offers dispatchable electricity yet still relies on DAC to offset residual emissions, even when deploying deep CCS with more than 90% CO2 capture. Coal-biomass co-firing with CCS, a subset of BECCS, is a reliable energy production technology that can be retrofitted from existing electricity generation units (EGUs). Power plant retrofit maximizes the use of the current U.S. coal power fleet without the need for large-scale deployment of new renewable power, battery storage, or DAC. Retrofitting coal-biomass co-firing with deep CCS in EGUs is a promising option, but not a universal solution. Biomass co-firing at a power plant introduces economic challenges and indirectly poses pressure on land and water resources. Meanwhile, retrofitting deep CCS affects plant efficiency and raises electricity generation costs. Overall, the technical feasibility and economic viability of plant retrofits vary across EGUs, as they are contingent upon the regional availability of biomass, unit-specific characteristics, site-specific fuel supply costs, and adjacent CO2 storage potential. Government incentives like 45Q can improve the retrofit viability, though the impact requires further quantification. A comprehensive analysis at the unit level is essential to address the question regarding the fate of the U.S. coal-fired electricity generation fleet toward the net-zero emission goal. This study conducts a systematic techno-economic-environmental assessment of EGUs to identify the viability of biomass co-firing and deep CCS retrofits in the U.S. coal-fired power fleet. Specifically, it characterizes the techno-economic performance of deep carbon capture, estimates life cycle greenhouse gas (GHG) emissions, and conducts a fleet-level assessment on retrofit viability. The key objectives are (1) to estimate the unit-specific performance and retrofitted cost under various biomass co-firing levels and CO2 capture rates; (2) to determine the possibility of reaching net-zero emission at the fleet level; (3) to quantify the cumulative capacities that are suitable for plant retrofits under current and future biomass supply scenarios; and (4) to improve the understanding of policy impacts on such retrofits to help the power sector’s transition to a net-zero economy. Techno-economic Model of Deep Carbon Capture. This study develops the performance and economic models for Monoethanolamine-based post-combustion CO2 capture at 95–99% capture rates. The process is simulated in Aspen Plus, analyzing the performance of carbon capture technology by varying the plant sizes, solvent lean loading, CO2 concentrations, and flue gas inlet temperature. Based on the key inputs and output parameters of CO2 capture, a reduced-order performance model of deep carbon capture is formulated. In addition, an engineering-economic model integrating the performance metrics is developed to estimate the capital as well as operation and maintenance (O&M) costs. Capital cost estimations follow the framework of the Integrated Environmental Control Model (IECM) and incorporate data regressions from three technical reports by IECM, the National Energy Technology Laboratory (NETL), and the National Renewable Energy Laboratory. The O&M cost estimation utilizes the actual inventory consumption rate and labor requirements. Both performance and cost models are embedded into IECM v13.0-beta, a fossil-fuel power plant modeling tool. Life Cycle Assessment of Power Plants. This study estimates the GHG emissions of power plants through life cycle assessment (LCA). The LCA scope includes fuel supply, combustion-based power generation, and CO2 transport and storage. The fuel-based life cycle module is designed following the framework of the NETL Unit Process Library and CO2U LCA Guidance Toolkit. The module is then incorporated into IECM v13.0-beta. The process-based LCA is applied to estimate the GHG emissions of coal and biomass supply, coal- and coal-biomass co-firing power plant operation, as well as CO2 pipeline transport and geographical sequestration. An uncertainty analysis is conducted to quantify the variability and uncertainty associated with the LCA using the Latin Hypercube Sampling (LHS) method. Fleet-level Assessment. This study evaluates the technical and economic feasibility of selected coal-fired EGUs, examines the role of tax credits in retrofit viability, and assesses the competitiveness of retrofitted units against other low-carbon options. Unit screening identifies EGUs for the study, focusing on new, efficient baseload units with air pollution controls. The power plant databases are then established to organize unit-specific information on performance and operating conditions from the relevant public databases. Biomass for co-firing retrofits is selected based on home and neighboring county availability, ensuring sustained operation with at least a 5% co-firing level. The CO2 storage site is determined by state-level storage potential, with ArcGIS Pro and NETL CO2 Saline Storage Cost Model used to identify the optimal balance between the nearest transport distances and affordable storage costs. The latest IECM v13.0-beta is then employed to configure and evaluate the eligible EGUs with or without the deployment of deep CCS and biomass co-firing. A supply curve is established to illustrate the cumulative installed capacity suitable for retrofits at different cost levels. A sensitivity analysis on tax credits for carbon sequestration is performed. Finally, a unit-level cost comparison is conducted among retrofitted plants, renewable power with battery storage, and abated fossil fuels with DAC. Expected Results. This study evaluates the technical, economic, and environmental metrics of each EGU across an array of CO2 capture rates and biomass co-firing level scenarios. Unit-level comparisons will identify critical factors influencing technical performance. The supply curves with and without tax incentives will provide insights into the impact of tax credits on biomass co-firing and CCS deployment. The cost comparisons with renewables and DAC-retrofit will assess the competitiveness of the retrofitted units. Life cycle emissions from each unit will be assessed to identify the scenarios under which net-zero emissions can be achieved. These analyses are expected to determine the total coal-fired capacity suitable for serving as a low-carbon energy source with or without tax incentives. The study results are novel in identifying optimal unit-specific strategies for producing carbon-neutral power, whether through retrofitting EGUs with deep CCS, biomass co-firing, DAC, or installing renewable power with battery. The findings will provide insight into nationwide efforts to ensure reliable, affordable, and low-carbon electricity. It also will inform investment decisions and policies in the deployment of deep carbon capture and negative emission technologies for a net-zero energy future.

Biomass Co-firing↗

Sorbent Based Post-Combustion CO 2 Slipstream Testing

TDA Research, Inc. has developed a low-cost sorbent (alkalized alumina) based technology for post-combustion CO 2 capture. The sorbent runs in an isothermal process for adsorption and regeneration. Neither temperature swing nor pressure swing is needed. TDA designed a system which operated 10 fixed beds to simulate a moving bed process. The flow pattern was optimized to minimize the steam usage for regeneration. An excellent sorbent (Batch 1) was also developed with collaboration with our partner. The sorbent degraded after long term operation. We developed a reprocessing procedure, which can be conducted in situ, to restore the sorbent capture capacity as the fresh sorbent after running for about 1250 hours. The reprocessing extended the sorbent longevity significantly. TDA designed a pilot unit (40’ x 32’ x 11.5’), processing flue gas equivalent to 0.5 MW of power generation. It had 10 beds and each bed could hold 1.75 m 3 of sorbent. We worked with Springs Fabrication, Inc. to complete the construction of the pilot unit. It was then shipped and installed at NCCC. The pilot unit was kept running in 24-hour mode when the flue gas and steam were available. It could run automatically without operator on site. Parametric and long-term (2 months) tests were carried out successfully. The results showed that TDA’s process can achieve 90% capture and 95% CO 2 purity for both coal and NG flue gases. For coal flue gas, the system reached performance target when processing up to 0.62 MW flue gas, 24% higher than the design capacity. Thus, capital cost could be saved on the reactors and sorbent. The strip air flow was designed to be 0.25 of that of the flue gas. The test data showed the strip/flue ratio can be reduced to as little as 0.18, which saves the power consumption for the strip air blower. The pressure drop was found to be lower than what the empirical equation calculated. The sorbent still had 91.7% of original capacity after 3-month test. With the data from the pilot test, we updated the TEA. For a 550-MW e supercritical coal fired power plant with CO 2 capture, the capture cost for TDA’s process is $34.9/tonne CO 2 captured, which meets DOE’s goal of $40/tonne and is 17.1% less than the DOE baseline Case 12. Therefore, TDA’s process has a good potential for commercialization.

01 COAL, LIGNITE, AND PEAT↗

Carbon Capture on Air Liquide United States Gulf Coast Steam Methane Reformer using the Cryocap TM Flue Gases Process

The objective of this DOE-funded project is to execute and complete a Front-End Engineering and Design (FEED) study for a commercial-scale carbon capture project for Air Liquide’s Steam Methane Reformer (SMR) located at La Porte, near Houston, Texas. The Host Site is one of Air Liquide’s largest SMR assets, and supplies hydrogen to the Air Liquide Gulf Coast Hydrogen System, which serves refiners and petrochemical manufacturers through an existing H2 pipeline spanning roughly 200 miles from Port Arthur, TX to Bay City, TX. The Host Site produces up to 116.5 million standard cubic feet per day (MMSCFD) of gaseous hydrogen and emits approximately 950 ktpy CO 2 at the nameplate capacity. The evolving importance of decarbonized H2 for both existing customers and new markets, as well as the availability and intent of prominent third-party partners to transport and sequester captured CO 2 in locally abundant geological sites for 45Q credits, make the AL US Gulf Coast SMR an ideal site for the proposed FEED study. The envisioned carbon capture system is based on Air Liquide’s proprietary Cryocap™ Flue Gas (FG) process. The integration of the Cryocap™ FG technology to the existing SMR would enable the capture of 900 ktpy of CO 2 , with a net carbon capture rate of >95% and with minimum impact on the levelized cost of hydrogen produced at 99.97% purity.

03 NATURAL GAS↗