Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluorescence sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Scales of variability of bio-optical properties as observed from near-surface drifters

A drifter equipped with bio-optical sensors and an automated water sampler was deployed in the California Current as part of the coastal transition zone program to study the biological, chemical, and physical dynamics of the meandering filaments. During deployments in 1987 and 1988, measurements were made of fluorescence, downwelling irradiance, upwelling radiance, and beam attenuation using several bio-optical sensors. Samples were collected by an automated sampler for later analysis of nutrients and phytoplankton species compositon. Large-scale spatial and temporal changes in the bio-optical and biological properties of the region were driven by changes in phytoplankton species composition which, in turn, were associated with the meandering circulation. Variance spectra of the bio-optical paramenters revealed fluctuations on both diel and semidiurnal scales, perhaps associated with solar variations and internal tides, respectively. Offshore, inertial-scale fluctuations were apparent in the variance spectra of temperature, fluorescence, and beam attenuation. Although calibration samples can help remove some of these variations, these results suggest that the use of bio-optical data from unattended platforms such as moorings and drifters must be analyzed carefully. Characterization of the scaled of phytoplankton variability must account for the scales of variability in the algorithms used to convert bio-optical measurments into biological quantities.

Abbott, Mark R.↗

Let's Exploit Available Knowledge on Vegetation Fluorescence

The potential to measure vegetation fluorescence from space (1) and to derive from it direct information on the gross primary productivity (GPP) of terrestrial ecosystems is probably the most thrilling development in remote sensing and global ecology of recent years, as it moves Earth observation techniques from the detection of canopy biophysics (e.g., fraction of absorbed radiation) and biochemistry (chlorophyll and nitrogen content) to the realm of ecosystem function. The existence of a functional relationship between fluorescence and photosynthesis has been elucidated over the last decade by several laboratories, notably as part of the preliminary studies of the European Space Agency Fluorescence Explorer (FLEX) Earth Explorer Mission. The empirical observation presented by Guanter et al. (2) of a linear relationship between fluorescence radiance and GPP, however, provides the first experimental confirmation of the feasibility of the approach— already thoroughly tested at leaf level—at the desired scale, despite the confounding effects associated with the satellite detection of such a faint signal. A word of clarification is needed here. The use of fluorescence as a probe of leaf photochemistry has been a staple of plant ecophysiology for decades, rooted in a sound understanding of photosynthetic energy dissipation. However, most past studies had to rely for the interpretation of results on active (pulse-saturated) techniques, making them unsuitable for remote-sensing applications. Over recent years, however, novel process based models have been developed for the interpretation of steady-state, solar-induced fluorescence at the leaf to canopy scale (3). We are therefore in a position to move beyond the mere empirical observation of an association between GPP and fluorescence radiance. In particular, Guanter et al. (2) base their analysis on the assumption of a constant ratio between photosynthetic and fluorescence light use efficiencies (equation 3 in ref. 2).We know, however, that the ratio is not constant, but changes widely in response to light, CO2, stomatal limitations, and extreme stress (4, 5). What’s more, we can make sense of such changes, thus extracting valuable information from the very scatter that is apparent in their data. However, this process will require the availability of more tailored instruments, such as the one planned for the FLEX mission. As already stressed by Guanter et al. (2), the spatial resolution of the Global Ozone Monitoring Experiment-2 sensor (40 × 80 km) makes it difficult to compare meaningfully the fluorescence signal with ground measurements, when only 60–70% of the footprint consists of the desired land-cover type (table S1 in ref. 2), suggesting that this could be largely responsible for the low signals observed in European grasslands. Moreover, the overpass time of the MetOp-A satellite (9:30 AM) implies that fluorescence is generally measured under light-limiting conditions, when fluorescence is only marginally affected by stomatal closure even under stress conditions. This result could explain the seasonal mismatch with daily GPP observed in natural ecosystems in the absence of irrigation (figure 4 in ref. 2). We hope, therefore, that this welcome contribution to this fast-advancing field will help demonstrate the potential of the new technique, and pave the way for more refined studies under both a technological and scientific point of view.

Space↗

Direct observation of Mn distribution/speciation within and surrounding a basidiomycete fungus in the production of Mn-oxides important in toxic element containment

Biogenic manganese (Mn) oxides occur ubiquitously in the environment including the uranium (U) mill tailings at the Ningyo-toge U mine in Okayama, Japan, being important in the sequestration of radioactive radium (Ra). To understand the nanoscale processes in Mn oxides formation at the U mill tailings site, Mn 2+ absorption by a basidiomycete fungus, Coprinopsis urticicola, isolated from Ningyo-toge mine water samples, was investigated in the laboratory under controlled conditions utilizing electron microscopy, synchrotron-based X-ray analysis, and fluorescence microscopy with molecular pH probe. The fungus’ growth was first investigated in an agar-solidified medium supplemented with 1.0 mmol/L of Mn 2+ , ± Cu 2+ (50 – 200 µM), ± Zn 2+ (50 – 200 µM), or ± diphenyleneiodonium chloride (DPI) (50 – 100 µM) at 25 °C. The results revealed that Zn 2+ has no significant effects on the Mn oxides formation, whereas Cu 2+ and DPI significantly inhibit both fungal growth and Mn oxidation, indicating superoxide-mediated Mn oxidation. During the interaction of Mn 2+ with the fungi in solution medium at the initial pH of 5.67, a small fraction of Mn 2+ infiltrated into the fungal hyphae within 8 h, forming a few tens nm-sized concentrates of soluble Mn2+ in the intracellular pH of ~6.5, which can be released back to solution within a day as shown in a subsequent releasing experiment. After 1 day of incubation, Mn oxides began to precipitate on the hyphae, which were characterized to be fibrous nanocrystals with a hexagonal birnessite-structure, these forming spherical aggregates with a diameter of ~1.5 µm. When the fungi were reacted using the Ningyo-toge mine water, the Mn concentration decreased at a rate of 1.0 mmol·day-1 per unit dry weight. The nanoscale processes associated with the fungi derived from the Ningyo-toge mine area provides additional insights into the existing mechanisms of Mn oxidation by filamentous fungi at other U mill tailings sites under circumneutral pH conditions. Such processes add to the class of reactions important to the sequestration of toxic elements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Description of the Electronic Structure of Oxyhemoglobin Using Fe L-Edge X-ray Absorption Spectroscopy

The electronic structure of oxyhemoglobin has been controversial since the discovery of the compound’s diamagnetism in 1936. Here, this study uses partial fluorescence yield Fe L-edge X-ray absorption spectroscopy (XAS) in the 3s→2p fluorescence on oxyhemoglobin solutions, measured using a transition-edge sensor detector, to obtain a quantitative experimental description of the electronic structure of the O 2 -bound iron site. The spectrum is very different from typical low-spin Fe II and Fe III heme spectra, and multiplet simulations indicate a mixed ground configuration with ∼57% low-spin Fe III and ∼43% low-spin Fe II character. This is also very different from the Fe II character found for the picket-fence porphyrin model complex. The oxyhemoglobin L-edge XAS data further show that the O 2 ligand engages in a weak σ- but strong π-bond with the iron ion, leading to the overall strong Fe–O 2 bond required for O 2 transport.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct observation of the local microenvironment in inhomogeneous CO 2 reduction gas diffusion electrodes via versatile pOH imaging

In this study, we report how the micrometer-scale morphology of a carbon dioxide reduction (CO 2 R) gas diffusion electrode (GDE) affects the mass transport properties and with it, the local CO 2 R performance. We developed a technique to probe the microenvironment in a CO 2 R GDE via local pOH imaging with time- and three-dimensional spatial, micrometer-scale resolution. The local activity of hydroxide anions (OH - ), represented by the pOH value, around a GDE in contact with an aqueous electrolyte is a crucial parameter that governs the catalytic activity and CO 2 R selectivity. Here, we use fluorescence confocal laser scanning microscopy (CLSM) to create maps of the local pOH around a copper GDE by combining two ratiometric fluorescent dyes, one of which is demonstrated as a pOH sensor for the first time in this work. We observe that the local pOH decreases when current is applied due to the creation of OH - as a byproduct of CO 2 R. Interestingly, the pOH is lower inside microtrenches compared to the electrode surface and decreases further as trenches become more narrow due to enhanced trapping of OH - . We support our experimental results with multiphysics simulations that correlate exceptionally well with measurements. These simulations additionally suggest that the decreased pOH inside microcavities in the surface of a CO 2 R GDE leads to locally enhanced selectivity towards multicarbon (C 2+ ) products. This study suggests that narrow microstructures on the length scale of 5 μm in a GDE surface serve as local CO 2 R hotspots, and thus highlights the importance of a GDE's micromorphology on the CO 2 R performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-Ray Absorption Spectroscopy in High Temperature Oxidation of Metals and Alloys

An experimental technique is described that allows for the joint study of the kinetics and of the oxide structure during the high temperature oxidation of metal surfaces. Oxygen is supplied at the metal through an electrochemical oxygen pump and the oxygen pressure, at the metal surface, is measured during oxidation by a YSZ (yttria stabilized zirconia) oxygen sensor. XAS (x-ray absorption spectroscopy) is performed in fluorescence mode at the cation K edge and after each oxidation step. An appropriate analysis of the XAS spectra could provide information on both the oxidation kinetics and oxide structure. Experimental data on the high temperature oxidation of nickel, cobalt, and Fe(64%)Ni(36%) alloy, at low oxygen pressure, are reported and analyzed according to the proposed data reduction. These results indicate the presented technique to be particularly suitable for studying the hot corrosion of oxide film too thick for common surface spectroscopy (AUGER, ESCA) and too thin for conventional thermogravimetric technique.

Daniele Gozzi↗

A radiative transfer model for solar induced fluorescence using spectral invariants theory

Solar Induced chlorophyll Fluorescence (SIF) shows promise as an approach for estimating gross primary production (GPP) remotely. However, sun-target-sensor geometry and within-canopy absorption of SIF can alter the relationship between measured SIF and GPP, because sensors can only retrieve some unknown fraction of the total emitted SIF. Radiative transfer models that allow for variation in canopy structure and sensor angles are therefore needed to properly interpret SIF measurements. Spectral invariants allow decoupling of the wavelength-independent canopy structure and the wavelength-dependent leaf and soil spectrum in the radiative transfer process. Here we develop a simple analytical Fluorescence Radiative Transfer model based on Escape and Recollision probability (FluorRTER) to investigate the impact of canopy structure and sun-target-sensor geometry on SIF emissions. SIF simulations using the FluorRTER model agreed well the one-dimensional Soil-Canopy Observation of Photochemistry and Energy balance (SCOPE) model and the three-dimensional Fluorescence model with Weighted Photon Spread (FluorWPS) model. The fractional vegetation cover (FVC) and clumping effect have a large influence the SIF emission of 3D discontinuous canopies. For a moderate solar zenith angle (30°) and a clumped canopy (FVC?=?0.6), the difference between the directional observed SIF of a 3D discontinuous canopy and a 1D homogeneous canopy was as large as 43.2% and 38.4% for Photosystem I?+?II fluorescence at 685?nm and at 740?nm, respectively. By bridging the gap between observed SIF and total emitted SIF over 3D heterogeneous vegetation canopies, the FluorRTER model can assist with the angular normalization of SIF measurements and enable the more robust interpretation of how variations in SIF from directional and hemispherical in-situ, airborne and satellite observations relate to leaf and whole-canopy physiological processes.

Zeng, Yelu↗

Development of Carbon Flux Model Using ABI Data Over the Conterminous US

The satellite-driven carbon flux estimation has been playing important role to estimate continental-scale carbon budget. One of the biggest recent advances in the satellite-driven carbon flux modeling is utilization of high-frequent geostationary satellites to estimate diurnal cycle in carbon fluxes. The satellite based carbon flux estimation used the polar orbiting satellite sensors (e.g., Moderate Resolution Imaging Spectroradiometer (MODIS)), which allow us to observe target regions only once during the day. The new generation of geostationary satellite sensors provide frequent observations, often less than every 10 minutes. Here, we use GOES Advanced Baseline Imager (ABI) data to estimate hourly NEE over the conterminous US. We used the Terrestrial Observation Prediction System (TOPS) model for estimating hourly NEE. TOPS is a diagnostic ecosystem process model that simulates the fluxes of carbon and water through vegetation in response to climate variability. For the climate input, we developed hourly climate data using the same algorithm with NASA Earth Exchange Gridded Daily Meteorology (NEX-GDM) datasets based on machine learning techniques. The hourly climate data includes precipitation, maximum temperature, minimum temperature, dew point temperature, and solar radiation were derived from the Geostationary observations. The spatial patterns of ecosystem parameters used in TOPS are optimized using satellite Solar Induced Fluorescence (SIF) data. The high frequency GPP estimations from geostationary satellite sensors make it comparable to the instantaneous SIF data than daily GPP. We also used Ameriflux data for optimization of model parameters and the validation of the output. The derived data addresses the diurnal dynamics of carbon cycling at large scales and should help in reducing the uncertainties in carbon budget studies.

geostationary satellite↗

Hourly Carbon Fluxes Estimation Using the GOES Advanced Baseline Imager (ABI) Data Over the Conterminous USA

Tremendous efforts by Fluxnet scientists over the past few decades have made thousands of site-years of carbon flux observations available for advancing our understanding of carbon cycling in terrestrial ecosystems. One of key Fluxnet measurements is net ecosystem exchange (NEE) as it is directly related to carbon budget of terrestrial ecosystems. However, carbon flux estimation studies using satellite remote sensing have focused mainly on daily Gross Primary Production (GPP). The satellite based carbon flux estimation used the polar orbiting satellite sensors (e.g., Moderate Resolution Imaging Spectroradiometer (MODIS)), which allow us to observe target regions only once during the day. Because daily NEE is close to zero value, the carbon flux models using the polar orbiting satellite data have not been well used for NEE estimation. The new generation of geostationary satellite sensors (e.g., GOES Advanced Baesline Imager (ABI) and Himawari Advanced Himawari Imager (AHI)) provide frequent observations, often less than every 10 minutes. Here, we use GOES ABI data to estimate hourly NEE over the conterminous USA. We used the Terrestrial Observation Prediction System (TOPS) model for estimating hourly NEE. TOPS is a diagnostic ecosystem process model that simulates the fluxes of carbon and water through vegetation in response to climate variability. For the climate input, we developed hourly climate data using the same algorithm with NASA Earth Exchange Gridded Daily Meteorology (NEX-GDM) datasets based on machine learning techniques. The hourly climate data includes precipitation, maximum temperature, minimum temperature, dew point temperature, and, in particular, solar radiation that is directly derived from the Geostationary observations. The spatial patterns of ecosystem parameters used in TOPS are optimized using satellite Solar Induced Fluorescence (SIF) data. The high frequency GPP estimations from geostationary satellite sensors make it comparable to the instantaneous SIF data than daily GPP. We also used Fluxnet data for optimization of model parameters and the validation of the output. The derived data addresses the diurnal dynamics of carbon cycling at large scales and should help in reducing the uncertainties in carbon budget studies.

Geostationary satellite↗

Fluorescent bioaerosol particle concentrations measured by the DU WIBS during the AGINSGP field experiment

Real-time, immersion mode ambient fluorescent bioaerosol concentrations were measured at ARM’s Southern Great Plains (SGP) site during the AGINSGP field experiment using a Wideband Integrated Bioaerosol Sensor (DMT Inc.; WIBS-4A). The WIBS-4A is an optical particle counter that also measures single particle fluorescence in three channels, along with particle asymmetry. Particles are grouped into different types depending on which channels they fluoresce in. The instrument was located in the guest instrument facility (GIF) and measured fluorescent particle concentrations from April 7th to April 29th. Data presented here are the concentrations for each particle type, binned in 5 minute increments. Air was drawn into the GIF through custom aluminum stack inlets (6” inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8” or 1/4" copper lines, depending on sample flow of the instrument. Particles were dried using a silica diffusion dryer prior to analysis.

54 ENVIRONMENTAL SCIENCES↗

EVAP: A two-photon imaging tool to study conformational changes in endogenous Kv2 channels in live tissues

A primary goal of molecular physiology is to understand how conformational changes of proteins affect the function of cells, tissues, and organisms. Here, we describe an imaging method for measuring the conformational changes of the voltage sensors of endogenous ion channel proteins within live tissue, without genetic modification. We synthesized GxTX-594, a variant of the peptidyl tarantula toxin guangxitoxin-1E, conjugated to a fluorophore optimal for two-photon excitation imaging through light-scattering tissue. We term this tool EVAP (Endogenous Voltage-sensor Activity Probe). GxTX-594 targets the voltage sensors of Kv2 proteins, which form potassium channels and plasma membrane–endoplasmic reticulum junctions. GxTX-594 dynamically labels Kv2 proteins on cell surfaces in response to voltage stimulation. To interpret dynamic changes in fluorescence intensity, we developed a statistical thermodynamic model that relates the conformational changes of Kv2 voltage sensors to degree of labeling. We used two-photon excitation imaging of rat brain slices to image Kv2 proteins in neurons. We found puncta of GxTX-594 on hippocampal CA1 neurons that responded to voltage stimulation and retain a voltage response roughly similar to heterologously expressed Kv2.1 protein. Our findings show that EVAP imaging methods enable the identification of conformational changes of endogenous Kv2 voltage sensors in tissue.

59 BASIC BIOLOGICAL SCIENCES↗

Chlorophyll pigment concentration using spectral curvature algorithms - An evaluation of present and proposed satellite ocean color sensor bands

During the past several years symmetric three-band (460-, 490-, 520-nm) spectral curvature algorithm (SCA) has demonstrated rather accurate determination of chlorophyll pigment concentration using low-altitude airborne ocean color data. It is shown herein that the in-water asymmetric SCA, when applied to certain recently proposed OCI (NOAA-K and SPOT-3) and OCM (ERS-1) satellite ocean color bands, can adequately recover chlorophyll-like pigments. These airborne findings suggest that the proposed new ocean color sensor bands are in general satisfactorily, but not necessarily optimally, positioned to allow space evaluation of the SCA using high-precision atmospherically corrected satellite radiances. The pigment concentration recovery is not as good when existing Coastal Zone Color Scanner bands are used in the SCA. The in-water asymmetric SCA chlorophyll pigment recovery evaluations were performed using (1) airborne laser-induced chlorophyll fluorescence and (2) concurrent passive upwelled radiances. Data from a separate ocean color sensor aboard the aircraft were further used to validate the findings.

Hoge, Frank E.↗

Engineered Glucose Oxidase‐Carbon Nanotube Conjugates for Tissue‐Translatable Glucose Nanosensors

Abstract Continuous and non‐invasive glucose monitoring and imaging is important for disease diagnosis, treatment, and management. However, glucose monitoring remains a technical challenge owing to the dearth of tissue‐transparent glucose sensors. In this study, we present the development of near‐infrared fluorescent single‐walled carbon nanotube (SWCNT) based nanosensors directly functionalized with glucose oxidase (GOx) capable of immediate and reversible glucose imaging in biological fluids and tissues. We prepared GOx‐SWCNT nanosensors by facile sonication of SWCNT with GOx in a manner that—surprisingly—does not compromise the ability of GOx to detect glucose. Importantly, we find by using denatured GOx that the fluorescence modulation of GOx‐SWCNT is not associated with the catalytic oxidation of glucose but rather triggered by glucose‐GOx binding. Leveraging the unique response mechanism of GOx‐SWCNT nanosensors, we developed catalytically inactive apo‐GOx‐SWCNT that enables both sensitive and reversible glucose imaging, exhibiting a ΔF/F 0 of up to 40 % within 1 s of exposure to glucose without consuming the glucose analyte. We finally demonstrate the potential applicability of apo‐GOx‐SWCNT in biomedical applications by glucose quantification in human plasma and glucose imaging in mouse brain slices.

Chemistry↗

Development of local-power-free, remote α -particle detection using optical fibers

We demonstrate the application of fluorescence optical fiber coupled to a telecom grade fiber as a sensor for alpha particles using alpha-specific ZnS(Ag) scintillation materials whose wavelength is down-shifted into a low-loss region of the telecom grade fiber transmission band. Telecom-grade fiber optics offer a solution for sensing alpha radiation in deep repositories and cask storage for radioactive materials due to the stability of SiO 2 under normal environmental conditions and its relative radiation hardness at low radiation doses. Long-term nuclear waste storage facilities require sensors for the detection of leakage of radioactive materials that are maintenance-free, do not require power and can survive with no ‘wear out’ mechanisms for decades. By accomplishing the wavelength transformation, we maximize efficiencies in the detection of α-particles and signal transport and can detect alpha scintillation at distances on the order of >1 km with a sensor that is ~3% efficient and can be easily scaled as a sensor array. This paper describes the construction and testing of the sensor including manufacture of the controlled thickness films, verification of the wavelength shift from 450 to 620 nm and optimization of the sensitivity as a function of thickness. We also model the relative sensitivity of the film as a function of film thickness, and we demonstrate a signal-to-noise ratio of 10 at a range of greater than 1 km.

alpha particles↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Sounding rocket flight report, MUMP 9 and MUMP 10

The results of the launching of two-Marshall-University of Michigan Probes (MUMP 9 and MUMP 10), Nike-Tomahawk sounding rocket payloads, are summarized. The MUMP is similar to the thermosphere probe, an ejectable instrument package for studying the variability of the earth's atmospheric parameters. The MUMP 9 payload included an omegatron mass analyzer, a molecular fluorescence densitometer, a mini-tilty filter, and a lunar position sensor. This complement of instruments permitted the determination of the molecular nitrogen density and temperature in the altitude range from approximately 143 to 297 km over Wallops Island, Virginia, during January 1971. The MUMP 10 payload included an omegatron mass analyzer, an electron temperature probe, a cryogenic densitometer, and a solar position sensor. These instruments permitted the determination of the molecular nitrogen density and temperature and the charged particle density and temperature in the altitude range from approximately 145 to 290 km over Wallops Island during the afternoon preceding the MUMP 9 launch.

Grassl, H. J.↗

Sounding rocket flight report: MUMP 9 and MUMP 10

The results of the launching of two Marshall-University of Michigan Probes (MUMP 9 and MUMP 10), Nike-Tomahawk sounding rocket payloads, are summarized. The MUMP 9 paylaod included an omegatron mass analyzer, a molecular fluorescence densitometer, a mini-tilty filter, and a lunar position sensor. This complement of instruments permitted the determination of the molecular nitrogen density and temperature in the altitude range from approximately 143 to 297 km over Wallops Island, Virginia, during January 1971. The MUMP 10 payload included an omegatron mass analyzer, an electron temperature probe (Spencer, Brace, and Carignan, 1962), a cryogenic densitometer, and a solar position sensor. This complement of instruments permitted the determination of the molecular nitrogen density and temperature and the charged particle density and temperature in the altitude range from approximately 145 to 290 km over Wallops Island, Virginia, during the afternoon preceding the MUMP 9 launch in January 1971. A general description of the payload kinematics, orientation analysis, and the technique for the reduction and analysis of the data is given.

Grassl, H. J.↗

Ground-Based Measurements and Validation Protocols for Flex

The upcoming ESA Fluorescence Explorer (FLEX) mission will incorporate ground-based validations for fluorescence parameters and reflectance indices, drawing on an international network of sensors located at eddy covariance tower sites. A program has been initiated by the OPTIMISE program to develop methods and protocols for this network. A sensor system suite under evaluation by OPTIMISE includes the FLoX hyperspectral spectroradiometers. The NASA team at GSFC is participating in this experiment and we report first results from the 2017 summer measurements made above the canopy at the USDA/ARS Beltsville cornfield using the DFLoX and two other leaf-level measurement systems, the MONI-PAM and the FluoWat.

DFLOX↗