Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluorescence spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

PIXLISE-C: Exploring The Data Analysis Needs of NASA Scientists for Mineral Identification

NASA JPL scientists working on the micro x-ray fluorescence (microXRF) spectroscopy data collected from Mars surface perform data analysis to look for signs of past microbial life on Mars. Their data analysis workflow mainly involves identifying mineral com- pounds through the element abundance in spatially distributed data points. Working with the NASA JPL team, we identified pain points and needs to further develop their existing data visualization and analysis tool. Specifically, the team desired improvements for the process of creating and interpreting mineral composition groups. To address this problem, we developed an interactive tool that enables scientists to (1) cluster the data using either manual lasso-tool selection or through various machine learning clustering algorithms, and (2) compare the clusters and individual data points to make informed decisions about mineral compositions. Our preliminary tool supports a hybrid data analysis workflow where the user can manually refine the machine-generated clusters.

Davidoff, Scott↗

Perseverance’s Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Investigation

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) is a robotic arm-mounted instrument on NASA’s Perseverance rover. SHERLOC has two primary boresights. The Spectroscopy boresight generates spatially resolved chemical maps using fluorescence and Raman spectroscopy coupled to microscopic images (10.1 μm/pixel). The second boresight is a Wide Angle Topographic Sensor for Operations and eNgineering (WATSON); a copy of the Mars Science Laboratory (MSL) Mars Hand Lens Imager (MAHLI) that obtains color images from microscopic scales (∼13 μm/pixel) to infinity. SHERLOC Spectroscopy focuses a 40 μs pulsed deep UV neon-copper laser (248.6 nm), to a ∼100 μm spot on a target at a working distance of ∼48 mm. Fluorescence emissions from organics, and Raman scattered photons from organics and minerals, are spectrally resolved with a single diffractive grating spectrograph with a spectral range of 250 to ∼370 nm. Because the fluorescence and Raman regions are naturally separated with deep UV excitation (<250 nm), the Raman region ∼ 800 – 4000 cm−1 (250 to 273 nm) and the fluorescence region (274 to ∼370 nm) are acquired simultaneously without time gating or additional mechanisms. SHERLOC science begins by using an Autofocus Context Imager (ACI) to obtain target focus and acquire 10.1 μm/pixel greyscale images. Chemical maps of organic and mineral signatures are acquired by the orchestration of an internal scanning mirror that moves the focused laser spot across discrete points on the target surface where spectra are captured on the spectrometer detector. ACI images and chemical maps (< 100 μm/mapping pixel) will enable the first Mars in situ view of the spatial distribution and interaction between organics, minerals, and chemicals important to the assessment of potential biogenicity (containing CHNOPS). Single robotic arm placement chemical maps can cover areas up to 7x7 mm in area and, with the < 10 min acquisition time per map, larger mosaics are possible with arm movements. This microscopic view of the organic geochemistry of a target at the Perseverance field site, when combined with the other instruments, such as Mastcam-Z, PIXL, and SuperCam, will enable unprecedented analysis of geological materials for both scientific research and determination of which samples to collect and cache for Mars sample return.

Rohit Bhartia↗

Mineralogy and Astrobiology Detection Using Laser Remote Sensing Instrument

A multispectral instrument based on Raman, laser-induced fluorescence (LIF), laser-induced breakdown spectroscopy (LIBS), and a lidar system provides high-fidelity scientific investigations, scientific input, and science operation constraints in the context of planetary field campaigns with the Jupiter Europa Robotic Lander and Mars Sample Return mission opportunities. This instrument conducts scientific investigations analogous to investigations anticipated for missions to Mars and Jupiter's icy moons. This combined multispectral instrument is capable of performing Raman and fluorescence spectroscopy out to a >100 m target distance from the rover system and provides single-wavelength atmospheric profiling over long ranges (>20 km). In this article, we will reveal integrated remote Raman, LIF, and lidar technologies for use in robotic and lander-based planetary remote sensing applications. Discussions are focused on recently developed Raman, LIF, and lidar systems in addition to emphasizing surface water ice, surface and subsurface minerals, organics, biogenic, biomarker identification, atmospheric aerosols and clouds distributions, i.e., near-field atmospheric thin layers detection for next robotic-lander based instruments to measure all the above-mentioned parameters. OCIS codes: (120.0280) Remote sensing and sensors; (130.0250) Optoelectronics; (280.3640) Lidar; (300.2530) Fluorescence, laser-induced; (300.6450) Spectroscopy, Raman; (300.6365) Spectroscopy, laser induced breakdown

Abedin, M. Nurul↗

Surface-Enhanced X-Ray Fluorescence

Surface-enhanced x-ray fluorescence (SEn-XRF) spectroscopy is a form of surface- enhanced spectroscopy that was conceived as a means of obtaining greater sensitivity in x-ray fluorescence (XRF) spectroscopy. As such, SEn-XRF spectroscopy joins the ranks of such other, longer-wavelength surface-enhanced spectroscopies as those based on surface-enhanced Raman scattering (SERS), surface-enhanced resonance Raman scattering (SERRS), and surfaceenhanced infrared Raman absorption (SEIRA), which have been described in previous NASA Tech Briefs articles. XRF spectroscopy has been used in analytical chemistry for determining the elemental compositions of small samples. XRF spectroscopy is rapid and quantitative and has been applied to a variety of metal and mineralogical samples. The main drawback of XRF spectroscopy as practiced heretofore is that sensitivity has not been as high as required for some applications. In SEn-XRF as in the other surface-enhanced spectroscopies, one exploits several interacting near-field phenomena, occurring on nanotextured surfaces, that give rise to local concentrations of incident far-field illumination. In this case, the far-field illumination comes from an x-ray source. Depending on the chemical composition and the geometry of a given nanotextured surface, these phenomena could include the lightning-rod effect (concentration of electric fields at the sharpest points on needlelike surface features), surface plasmon resonances, and grazing incidence geometric effects. In the far field, the observable effect of these phenomena is an increase in the intensity of the spectrum of interest - in this case, the x-ray fluorescence spectrum of chemical elements of interest that may be present within a surface layer at distances no more than a few nanometers from the surface.

Anderson, Mark↗

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics↗

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics↗

SHERLOC Investigations at the Máaz and Séítah formations within Jezero crater

Introduction: The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) instrument combines microscopic imaging, native fluorescence and Raman spectroscopy to better understand the mineral and chemical makeup of rocks on the martian surface. Native fluorescence emissions from aromatic organic species allow for detection and classification of aromatic organic molecules, whereas Raman scattered photons from molecules allow identification of functional groups of organics, chemicals, and minerals. These signatures are obtained on a 100 micron spatial scale and collocated to images so textures, minerals and chemicals can all be compared [1]. Results: SHERLOC has been operating on Mars since February 18, 2021. As of this writing, we have analyzed 3 natural surfaces, and 5 abraded rock patches created during the Crater Floor Campaign within Jezero crater [2]. The Guillaumes target (from the Roubion outcrop, Roubion member of the Máaz Formation) is dominated by Ca-sulfate with patches of perchlorate. The Bellegarde target (from the Rochette outcrop, Rochette member of the Máaz Formation) exhibits Raman peaks that match hydrated Ca-sulfate, amorphous/microcrystalline silicate (AMS), carbonate, and phosphate phases. A fluorescence doublet at ~305 and ~325 nm was detected and is most likely due to indigenous organic material in the sample. The Garde target (from the Bastide outcrop, Bastide member of the Séítah Formation) is dominated by olivine and carbonate with AMS occurring across the material. The Dourbes target (from the Brac outcrop, Bastide member of the Séítah Formation) is dominated by olivine and shows minor amounts of carbonate, hydrated Ca-sulfate, and AMS. The Quartier target exhibits a large sulfate feature, as well as carbonate, perchlorate, olivine and a fluorescence doublet at 305 and 325 nm and is very similar to that observed at Bellegarde. In each of these samples we have identified fluorescence features that are likely aromatic organics native to the rock interiors. Acknowledgments: This work was carried out at the Jet Propulsion Laboratory, The California Institute of Technology under a contract from NASA.

L W Beegle↗

SHERLOC: Results of the first 350 sols of operations

On February 18th 2021, the Perseverance rover landed in Jezero crater, Mars. This site was chosen because orbiter data analysis provides evidence that the crater hosted a stream-fed lake during the Martian Noachian period. The Octavia Butler landing site is located ~1.9 km east of the remnants of a river delta. Deltaic and lacustrine sediments can preserve biosignatures, making Jezero crater a prime target for Mars sample return science. One of the seven instruments on Perseverance’s science payload is SHERLOC –Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals. SHERLOC combines fluorescence and Raman spectroscopy with microscopic imaging to analyze surface material to better understand the history of the aqueous environments recorded in the rocks of Jezero crater and to search for potential biosignatures. SHERLOC imaging obtains high spatial resolution images of geological targets to identify grain-scale structure and texture. SHERLOC spectroscopy enables high-sensitivity detection, characterization, and spatially resolved correlation of trace organic materials. Native fluorescence emissions from aromatic organic species allow for detection and classification of aromatic organic molecules, whereas Raman scattered photons from molecules allow identification of functional groups of organics, chemicals, and minerals. In the first 300 sols, SHERLOC has analyzed 3 natural surfaces, and 5 abraded rock patches created during the Crater Floor Campaign within Jezero crater. SHERLOC has been able to identify phosphates, amorphous/microcrystalline silicate (AMS), olivine, sulfates, and carbonates in abraded patches in the green zone campaign within Jezero Crater Máaz and Séítah formations. Within these detections we have begun to tell the story of what this crater was like when it was full of liquid water over 3 billion years ago. In each of these samples we have identified fluorescence features that are likely aromatic organics native to the rock interiors. We have identified multiple unique fluorescence signatures, within each of the abraded patches. The organic signatures have either been widely distributed over an extended area, which is probably due to planetary wide dust, or have spatially resolved locations that are collocated with different mineral signatures. Note: Additional information available on attachment.

L. W. Beegle↗

Raman spectroscopy of Ryugu particles and their extracted residues: Fluorescence background characteristics and similarities to CI chondrites

We present here an investigation of Ryugu particles recovered by the Hayabusa2 space mission and their extracted carbonaceous acid residues using Raman spectroscopy. Raman parameters of Ryugu intact grains and their acid residues are characterized by broad D (defect induced) and G (graphite) band widths, indicating the presence of polyaromatic carbonaceous matter with low thermal maturity. Raman spectra of Ryugu particles and CI (type 1) chondrites exhibit stronger laser-induced fluorescence backgrounds compared to Type 2 and Type 3 carbonaceous chondrites. The high fluorescence signatures and wide bandwidths of the D and G bands of Ryugu intact grains are similar to the Raman spectra observed in CI chondrites, reflecting the low structural order of their aromatic carbonaceous matter, and strengthening the link between Ryugu particles and CI chondrites. The high fluorescence background intensity of the Ryugu particles is due to multiple causes, but it is likely that the relative abundance of geometry-bearing macromolecular organic matter in total organic carbon contents makes a large contribution to the fluorescence intensities. Locally observed high fluorescence in the acid-extracted residues of Ryugu is due to nitrogen-bearing outlier phase. The high fluorescence signature is one consequence of the low degree of thermal maturity of the organic matter and supports evidence that the Ryugu particles have escaped significant parent body thermal metamorphism.

Ryugu particles↗

Calibration of the SHERLOC Deep Ultraviolet Fluorescence–Raman Spectrometer on the Perseverance Rover

We describe the wavelength calibration of the spectrometer for the scanning of habitable environments with Raman and luminescence for organics and chemicals (SHERLOC) instrument onboard NASA’s Perseverance Rover. SHERLOC utilizes deep ultraviolet Raman and fluorescence (DUV R/F) spectroscopy to enable analysis of samples from the Martian surface. SHERLOC employs a 248.6 nm deep ultraviolet laser to generate Raman-scattered photons and native fluorescence emission photons from near-surface material to detect and classify chemical and mineralogical compositions. The collected photons are focused on a charge-coupled device and the data are returned to Earth for analysis. The compact DUV R/F spectrometer has a spectral range from 249.9 nm to 353.6 nm (200 cm1 to 12, 000 cm1) (with a spectral resolution of 0.296 nm (40 cm1)). The compact spectrometer uses a custom design to project a high-resolution Raman spectrum and a low-resolution fluorescence spectrum on a single charge-coupled device. The natural spectral separation enabled by deep ultraviolet excitation enables wavelength separation of the Raman/fluorescence spectra. The SHERLOC spectrometer was designed to optimize the resolution of the Raman spectral region and the wavelength range of the fluorescence region. The resulting illumination on the charge-coupled device is curved, requiring a segmented, nonlinear wavelength calibration in order to understand the mineralogy and chemistry of Martian materials.

Kyle Uckert↗

Near-ultraviolet spectroscopy of Seyfert nuclei - Reddening and Bowen fluorescence

Spectra with high signal-to-noise ratios extending down to the atmospheric ultraviolet cut-off have been obtained for 11 Seyfert nuclei with narrow emission lines. In all objects the He II lines at 3204 A and 4686 A were measured simultaneously. Their ratio gives an estimate of reddening accurate to 0.14 mag in E(B-V). The redshifts of nine of the Seyfert galaxies are sufficient to allow detection of the O III 3133 line A, produced by Bowen fluorescence of He II Ly-alpha photons. The inferred efficiency of the Bowen mechanism ranges from 15 to 50 percent. The lower values, which are considerably less than the efficiencies found in planetary nebulae, are observed in Seyfert 2 nuclei with systematically weaker emission lines from high-excitation, high-density gas. In contrast, the Seyfert 1 and high-excitation Seyfert 2 nuclei have more 'normal' Bowen efficiencies. Several possible explanations are considered.

Malkan, Matthew A.↗

Multifunction Imaging and Spectroscopic Instrument

A proposed optoelectronic instrument would perform several different spectroscopic and imaging functions that, heretofore, have been performed by separate instruments. The functions would be reflectance, fluorescence, and Raman spectroscopies; variable-color confocal imaging at two different resolutions; and wide-field color imaging. The instrument was conceived for use in examination of minerals on remote planets. It could also be used on Earth to characterize material specimens. The conceptual design of the instrument emphasizes compactness and economy, to be achieved largely through sharing of components among subsystems that perform different imaging and spectrometric functions. The input optics for the various functions would be mounted in a single optical head. With the exception of a targeting lens, the input optics would all be aimed at the same spot on a specimen, thereby both (1) eliminating the need to reposition the specimen to perform different imaging and/or spectroscopic observations and (2) ensuring that data from such observations can be correlated with respect to known positions on the specimen. The figure schematically depicts the principal components and subsystems of the instrument. The targeting lens would collect light into a multimode optical fiber, which would guide the light through a fiber-selection switch to a reflection/ fluorescence spectrometer. The switch would have four positions, enabling selection of spectrometer input from the targeting lens, from either of one or two multimode optical fibers coming from a reflectance/fluorescence- microspectrometer optical head, or from a dark calibration position (no fiber). The switch would be the only moving part within the instrument.

Mouroulis, Pantazis↗

Photoionization of atoms and molecules

A literature review on the present state of knowledge in photoionization is presented. Various experimental techniques that have been developed to study photoionization, such as fluorescence and photoelectron spectroscopy, mass spectroscopy, are examined. Various atoms and molecules were chosen to illustrate these techniques, specifically helium and xenon atoms and hydrogen molecules. Specialized photoionization such as in positive and negative ions, excited states, and free radicals is also treated. Absorption cross sections and ionization potentials are also discussed.

Samson, J. A. R.↗

Geology orbiter comparison study

Instrument requirements of planetary geology orbiters were examined with the objective of determining the feasibility of applying standard instrument designs to a host of terrestrial targets. Within the basic discipline area of geochemistry, gamma-ray, X-ray fluorescence, and atomic spectroscopy remote sensing techniques were considered. Within the discipline area of geophysics, the complementary techniques of gravimetry and radar were studied. Experiments using these techniques were analyzed for comparison at the Moon, Mercury, Mars and the Galilean satellites. On the basis of these comparative assessments, the adaptability of each sensing technique was judged as a basic technique for many targets, as a single instrument applied to many targets, as a single instrument used in different mission modes, and as an instrument capability for nongeoscience objectives.

Cutts, J. A. J.↗

Pervasive Layering in the Lunar Highland Crust: Evidence from Apollos 15, 16,and 17

This paper presents results of a photogeologic reconnaissance of 70 mm photographs taken on the lunar surface during the Apollo 15, 16, and 17 missions, whose primary objective was to investigate the lunar highland crust. Photographs at all three sites, notably the Apennine Front, show pervasive layered structure. These layers are easily distinguished from lighting artifacts, and are considered genuine crustal structures. Their number, thickness, and extent implies that they are lava flows, not ejecta blankets or intrusive features. They appear to be the upper part of the earliest lunar crust, possibly forming a layer tens of kilometers thick. Remote sensing studies (X-ray fluorescence and reflectance spectroscopy), indicate that the highland crust is dominantly a feldspathic basalt. It is concluded that the highland layers represent a global crust formed by eruptions of high-alumina basalt in the first few hundred million years of the Moon's history.

Lowman, Paul D., Jr.↗

Cascaded Photoenhancement: Implications for Photonic Chemical and Biological Sensors

Our analysis shows that coupling of gold nanoparticles to microspheres will evoke a cascading effect from the respective photoenhancement mechanisms. We refer to this amplification process as cascaded photoenhancement, and the resulting cavity amplification of surface-enhanced Raman scattering (SERS) and fluorescence as CASERS and CAF, respectively. Calculations, based on modal analysis of scattering and absorption by compound spheres, presented herein indicate that the absorption cross sections of metal nanoparticles immobilized onto dielectric microspheres can be greatly enhanced by cavity resonances in the microspheres without significant degradation of the resonators. Gain factors associated with CSP of 10(exp 3) - 10(exp 4) are predicted for realistic experimental conditions using homogenous microspheres. Cascaded surface photoenhancement thus has the potential of dramatically increasing the sensitivities of fluorescence and vibrational spectroscopies.

Fuller, Kirk A.↗

The Mars 2020 Rover Mission: EISD Participation in Mission Science and Exploration

The Mars 2020 Rover mission will search for potential biosignatures on the martian surface, use new techniques to search for and identify tracelevel organics, and prepare a cache of samples for potential return to Earth. Identifying trace organic compounds is an important tenet of searching for potential biosignatures. Previous landed missions have experienced difficulty identifying unambiguously martian, unaltered organic compounds, possibly because any organic species have been destroyed on heating in the presence of martian perchlorates and/or other oxidants. The SHERLOC instrument on Mars 2020 will use ultraviolet (UV) fluorescence and Raman spectroscopy to identify trace organic compounds without heating the samples.

Fries, M.↗

Enhancing Global Change Experiments Through Integration of Remote‐Sensing Techniques

Global change experiments are often spatially and temporally limited because they are time‐ and labor‐intensive, and expensive to carry out. We describe how the incorporation of remote‐sensing techniques into global change experiments can complement traditional methods and provide additional information about system processes. We describe five emerging near‐surface remote‐sensing techniques: spectroscopy, thermal and fluorescence imaging, terrestrial laser scanning, digital repeat photography, and unmanned aerial systems. The addition of such techniques can reduce cost and effort, provide novel information, and expand existing observations by improving their context, accuracy, and completeness. In addition, we contend that use of airborne and satellite remote‐sensing data during site selection can improve the ecological representativeness of future experiments. We conclude by recommending a high level of communication and collaboration between remote‐sensing scientists and ecologists at all stages of global change experimentation.

Alexey N Shiklomanov↗