Search NASA⌕ Search

SEARCH · Search NASA

Results for “force limits vibration testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

112 records · Page 7

Developing Methods for Exercise System Kinematics Tracking

BACKGROUND How to quantify the load and forces produced by exercise equipment and their Vibration Isolation and Stabilization (VIS) platforms in-flight is an active area of investigation. Kinematic tracking paired with system modeling can provide insights as well as verification and validation of simulations used for system design and development. Traditional motion capture methods can require significant cost in equipment procurement and crew-time, but newer lessons learned can be leveraged [1]. The VIS systems of current and future exercise hardware on the International Space Station (ISS) such as the Cycle Ergometer with Vibration Isolation System (CEVIS) and the European Enhanced Exploration Exercise Device (E4D) are not currently outfitted with IMUs or similar measurement devices. Video-based methods would enable use of multi-purpose, crew-familiar flight equipment. An initial exploration of video-based solutions was performed utilizing 2-camera video from crew cycling on Teal-CEVIS on the ISS. METHODS AND RESULTS Our group has scoped a variety of video-based object tracking methods. To date, we have primarily investigated computer vision toolkits such as openCV. Techniques explored include key-point detection, background subtraction, region-of interest tracking, color-based tracking, tag masking and tracking, and corner detection. Although object-tracking and 6D pose estimation is a rich field, space applications are a unique problem that are challenging for existing software and toolkits. The majority of the existing object-tracking applications involve vehicles/pedestrians and household objects with simple backgrounds. We have identified the following features which pose particular challenges for on-station exercise equipment tracking: Busy and visually cluttered background Low-textured tracking object with relatively small motions Occlusions and motion by human subject and loose, floating objects Limited number of video cameras with no fixed global references Limited ability to add tags, markers, or visual references to the tracking object Lack of training data for Machine Learning (ML) algorithms CONCLUSION We will summarize the efficacy of techniques tested for a ground mock-trial and the on-station exercise trial. It is likely that human-in-loop feedback or a conglomerate of methods is required. ML-based methods, like those implemented for human body tracking [2], may still be a viable option, but more training data and validation is needed.

L B Nilsson↗

Developing Methods for Exercise System Kinematic Tracking

BACKGROUND How to quantify the load and forces produced by exercise equipment and their Vibration Isolation and Stabilization (VIS) platforms in-flight is an active area of investigation. Kinematic tracking paired with system modeling can provide insights as well as verification and validation of simulations used for system design and development. Traditional motion capture methods can require significant cost in equipment procurement and crew-time, but newer lessons learned can be leveraged [1]. The VIS systems of current and future exercise hardware on the International Space Station (ISS) such as the Cycle Ergometer with Vibration Isolation System (CEVIS) and the European Enhanced Exploration Exercise Device (E4D) are not currently outfitted with IMUs or similar measurement devices. Video-based methods would enable use of multi-purpose, crew-familiar flight equipment. An initial exploration of video-based solutions was performed utilizing 2-camera video from crew cycling on Teal-CEVIS on the ISS. METHODS AND RESULTS Our group has scoped a variety of video-based object tracking methods. To date, we have primarily investigated computer vision toolkits such as open CV. Techniques explored include key-point detection, background subtraction, region-of interest tracking, color-based tracking, tag masking and tracking, and corner detection. Although object-tracking and 6D pose estimation is a rich field, space applications are a unique problem that are challenging for existing software and toolkits. The majority of the existing object-tracking applications involve vehicles/pedestrians and household objects with simple backgrounds. We have identified the following features which pose particular challenges for on-station exercise equipment tracking: 1. Busy and visually cluttered background 2. Low-textured tracking object with relatively small motions 3. Occlusions and motion by human subject and loose, floating objects 4. Limited number of video cameras with no fixed global references 5. Limited ability to add tags, markers, or visual references to the tracking object 6. Lack of training data for Machine Learning (ML) algorithms CONCLUSION We will summarize the efficacy of techniques tested for a ground mock-trial and the on-station exercise trial. It is likely that human-in-loop feedback or a conglomerate of methods is required. ML-based methods, like those implemented for human body tracking [2], may still be a viable option, but more training data and validation is needed.

L Nilsson↗

Recent Improvements and Verification of A Full Body Model in Opensim

BACKGROUND: The dynamic feasibility [1,2] criterion, that the subject’s Center of Pressure (COP) be located within the Base of Support (BOS) which outlines the feet, has aided in assessing the stability of human motion recorded on earth while performing the recorded tasks in lunar gravity or as countermeasures exercises on a vibration isolation and stabilization system in microgravity. The convex hull of the BOS on the platform under the subject’s feet was estimated using virtual markers on the feet of the scaled subject model. The COP was calculated using the ground reaction forces and moments determined from motion capture data with biomechanical modeling tools [3]. Occasionally, large-amplitude oscillatory spikes or “artifacts” were observed in the subject’s linear and angular momentum derivatives, affecting some COP data derived from motion capture. The purpose of this investigation was to assess and improve the accuracy of model scaling and BOS estimation as well as to determine the efficacy of model adjustments in mitigating artifacts influencing motion capture-derived ground reaction force and COP results. METHODS: To aid evaluation of proposed process and model updates, motion capture data were collected for two subjects during unit test and range of motion trials, lunar tasks, and countermeasures exercise motions. Markers were added to the full body Plug-in Gait marker set [4] during data collection. New markers were placed on the front, back, sides, and top of the head to improve scaling using distances between marker pairs. Medial elbow markers were added to stabilize the upper arm during OpenSim Inverse Kinematics (IK) [5]. Finally, markers were added on the outer edge of the heels and on the outside edges of the first and last toes on each foot. These additional foot markers were made available to test new automated foot scaling techniques and to calculate the error between the subject’s estimated and recorded BOS. The modified unscaled OpenSim Full Body Rajagopal Model [6,7] was adjusted using some previously investigated techniques [8] to mitigate rapid shifts in joint angles occurring during IK, as these were found to cause the spike artifacts observed in subsequent stages of analysis. Since OpenSim models use Euler angles and rotation sequences, the arm axes of rotation were adjusted, and the pelvis order of rotation was changed to minimize the likelihood of encountering “gimbal lock” during common human motion. The model clavicle, arm, elbow, wrist, pelvis, and ankle angle limits were adjusted to better accommodate the full human range of motion seen in exercise and lunar data. The shoulder joint center was calculated using a “pivoting” algorithm [9], and both shoulder joint center and upper arm markers were included during IK to provide additional shoulder stability on a case-by-case basis. The quality of IK results was assessed by three criteria: minimizing error between recorded motion capture markers and model markers, checking for reasonable rates of change in joint angles between fames (i.e., no IK artifacts), and ensuring the absence of spikes in the inertial forces and angular momentum derivatives calculated using a custom OpenSim plugin [10]. RESULTS: The additional markers placed on the subject during data collection allowed the head and feet to be scaled more accurately using distances between new marker pairs. Scaling with BOS markers placed on the subject and removing the limit on subtalar angle resulted in more accurate BOS determination. Unrealistically large changes in joint angles between frames could be reduced by including clavicle, sternum, and medial elbow markers during IK. In cases with large arm ranges of motion, results could be further improved by running IK using medial elbow and virtual shoulder joint center markers. Model adjustments significantly improved the IK results affecting COP calculation and increased the accuracy of BOS estimation.

C A Bell↗

Meeting the Grand Challenge of Protecting Astronauts Health: Electrostatic Active Space Radiation Shielding for Deep Space Missions

This report describes the research completed during 2011 for the NASA Innovative Advanced Concepts (NIAC) project. The research is motivated by the desire to safely send humans in deep space missions and to keep radiation exposures within permitted limits. To this end current material shielding, developed for low earth orbit missions, is not a viable option due to payload and cost penalties. The active radiation shielding is the path forward for such missions. To achieve active space radiation shielding innovative large lightweight gossamer space structures are used. The goal is to deflect enough positive ions without attracting negatively charged plasma and to investigate if a charged Gossamer structure can perform charge deflections without significant structural instabilities occurring. In this study different innovative configurations are explored to design an optimum active shielding. In addition, to establish technological feasibility experiments are performed with up to 10kV of membrane charging, and an electron flux source with up to 5keV of energy and 5mA of current. While these charge flux energy levels are much less than those encountered in space, the fundamental coupled interaction of charged Gossamer structures with the ambient charge flux can be experimentally investigated. Of interest are, will the EIMS remain inflated during the charge deflections, and are there visible charge flux interactions. Aluminum coated Mylar membrane prototype structures are created to test their inflation capability using electrostatic charging. To simulate the charge flux, a 5keV electron emitter is utilized. The remaining charge flux at the end of the test chamber is measured with a Faraday cup mounted on a movable boom. A range of experiments with this electron emitter and detector were performed within a 30x60cm vacuum chamber with vacuum environment capability of 10-7 Torr. Experiments are performed with the charge flux aimed at the electrostatically inflated membrane structure (EIMS) in both charged and uncharged configurations. The amount of charge shielding behind and around the EIMS was studied for different combinations of membrane structure voltages and electron energies. Both passive and active shielding were observed, with active shielding capable of deflecting nearly all incoming electrons. The pattern of charge distribution around the structure was studied as well as the stability of the structures in the charge flow. The charge deflection experiments illustrate that the EIMS remain inflated during charge deflection, but will experience small amplitude oscillations. Investigations were performed to determine a potential cause of the vibrations. It is postulated these vibrations are due to the charge flux causing local membrane charge distribution changes. As the membrane structure inflation pressure is changed, the shape responds, and causes the observed sustained vibration. Having identified this phenomenon is important when considering electrostatically inflated membrane structures (EIMS) in a space environment. Additionally, this project included a study of membrane material impacts, specifically the impact of membrane thickness. Extremely thin materials presented new challenges with vacuum preparation techniques and rapid charging. The thinner and lighter membrane materials were successfully inflated using electrostatic forces in a vacuum chamber. However, care must be taken when varying the potentials of such lighter structures as the currents can cause local heating and melting of the very thin membranes. Lastly, a preliminary analysis is performed to study rough order of magnitude power requirements for using EIMS for radiation shielding. The EIMS power requirement becomes increasingly more challenging as the spacecraft voltage is increased. As a result, the emphasis is on the deflection of charges away from the spacecraft rather than totally stopping them. This significantly alleviates the initial power requirements. With modest technological development(s) active shielding is emerging to be a viable option.

Radiation↗