Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

Electronic interactions in Dirac fluids visualized by nano-terahertz spacetime interference of electron-photon quasiparticles

Ultraclean graphene at charge neutrality hosts a quantum critical Dirac fluid of interacting electrons and holes. Interactions profoundly affect the charge dynamics of graphene, which is encoded in the properties of its electron-photon collective modes: surface plasmon polaritons (SPPs). Here, we show that polaritonic interference patterns are particularly well suited to unveil the interactions in Dirac fluids by tracking polaritonic interference in time at temporal scales commensurate with the electronic scattering. Spacetime SPP interference patterns recorded in terahertz (THz) frequency range provided unobstructed readouts of the group velocity and lifetime of polariton that can be directly mapped onto the electronic spectral weight and the relaxation rate. Our data uncovered prominent departures of the electron dynamics from the predictions of the conventional Fermi-liquid theory. The deviations are particularly strong when the densities of electrons and holes are approximately equal. The proposed spacetime imaging methodology can be broadly applied to probe the electrodynamics of quantum materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Vasomotion in Human Fingers

Introduction: We describe methods by which vasomotion can be recorded in awake and anesthetized human subjects without significant interference from other spontaneous vascular oscillations. Methods: In three separate studies, we used photoplethysmography (PPG) to record vasomotion in fingertips. In Study 1, we induced chemical sympathectomy in the studied hand of 11 awake subjects who received intravenous dexmedetomidine infusions. In Study 2, we administered four progressively increasing intravenous dexmedetomidine infusions to 16 awake volunteers. In Study 3, we recorded vasomotion simultaneously from 6 fingers of 7 patients who were under dexmedetomidine-based anesthesia. Five-minute epochs of PPG recordings that displayed slow vascular oscillations were analyzed for frequency and amplitude. Results: In Study 1, vasomotion frequencies were 0.025 ± 0.008 Hz. In Study 2, vasomotion frequencies were 0.033 ± 0.006 Hz, and 0.032 ± 0.008 Hz during the two highest dexmedetomidine infusion steps. In Study 3, vasomotion frequencies ranged from 0.020 to 0.037 Hz and were observed in all 6 fingers, with no synchrony between the six fingers. Conclusion: The vascular oscillations we observed without significant interference from other spontaneous oscillations are independent of neural activity (Study 1), local in nature (Study 3), and associated with alpha-2-adrenoceptor activation, consistent with known properties of vasomotion.

Cardiovascular System & Cardiology↗

Hyperspectral acquisition with ScanImage at the single pixel level: application to time domain coherent Raman imaging

We present a comprehensive strategy and its practical implementation using the commercial ScanImage software platform to perform hyperspectral point scanning microscopy when a fast time-dependent signal varies at each pixel level. In the proposed acquisition scheme, the scan along the X-axis is slowed down while the data acquisition is maintained at a high pace to enable the rapid acquisition of the time-dependent signal at each pixel level. The ScanImage generated raw 2D images have a very asymmetric aspect ratio between X and Y, the X axis encoding both for space and time acquisition. The results are X-axis macro-pixel where the associated time-dependent signal is sampled to provide hyperspectral information. We exemplified the proposed hyperspectral scheme in the context of time-domain coherent Raman imaging, where a pump pulse impulsively excites molecular vibrations that are subsequently probed by a time-delayed probe pulse. In this case, the time-dependent signal is a fast acousto-optics delay line that can scan a delay of 4.5ps in 25 μ s at each pixel level. With this acquisition scheme, we demonstrate ultra-fast hyperspectral vibrational imaging in the low frequency range [10 cm −1 , 150 cm −1 ] over a 500 μm field of view (64 x 64 pixels) in 130ms (∼ 7.5 frames/s). The proposed acquisition scheme can be readily extended to other applications requiring the acquisition of a fast-evolving signal at each pixel level.

Metais, Samuel↗

Single-element balanced detector giving 65 dB CMRR at 30 MHz

We present a simple design for a single-element balanced detector (BD) that utilizes optical fibers in the sensing and reference channels with path length differences set to detect the differential signal at a desired frequency. With this approach, we easily achieve a common-mode rejection ratio of 65 dB, corresponding to the shot-noise limit of our setup. The CMRR demonstration is made in the MHz frequency range but could be extended to the kHz or GHz range. Using a single detector, the BD achieves stable CMRR over extended periods and does not require careful matching of detectors and amplification electronics. We demonstrate the single-element balanced detector design using the optical Kerr effect induced by a 30 MHz pulsed laser, showing a significant improvement over similar experiments using a commercial balanced detector.

Badilla-Nunez, Kelly [Georgia Institute of Technol↗

Spectral interferometry-based microwave-frequency vibrometry for integrated acoustic wave devices

Microwave phononics is a promising platform for sensing, computing, and quantum information science; thus, sensitive and high-throughput characterization tools are needed not only for device verification and optimization but also for revealing transient and nonlinear dynamics. Existing interferometric optical vibrometers for 2D mapping are challenged by operating point stabilization, surface reflectivity contrast, and long acquisition time. Here, we use spectral interferometry, which is insensitive to these factors and utilizes a continuous raster scanning scheme for vibration mapping with high throughput. We intensity-modulate our broadband light source with an electro-optic modulator to resolve vibrations at microwave frequencies. Our system requires no fast photodetector or digitizer operating in the microwave frequency range. We image the 1 GHz vibration field of a 300 × 150 µm 2 area of an entire surface acoustic wave device in 10 min with simultaneous surface profilometry. Our system has a vibration sensitivity of 120 fm/sqrt(Hz) and a linear throughput of 0.77 mm/s on the chip surface. The technique offers capabilities for characterizing a wide range of acoustic wave and micromechanical devices to better understand their behavior and performance.

47 OTHER INSTRUMENTATION↗

The ion-ion correlations in organic ionic plastic crystal

Organic ionic plastic crystals (OIPCs) are emerging as promising electrolyte materials for solid-state batteries. However, despite the fast ionic diffusion, OIPCs exhibit relatively low DC conductivity in solid phases caused by strong ion-ion correlations that suppress charge transport. To understand the origin of this suppression, we performed a study of ion dynamics in the OIPC 1-Ethyl-1-methylpyrrolidinium bis (trifluoromethyl sulfonyl) imide [P 12 ][TFSI] utilizing dielectric spectroscopy, light scattering, and Nuclear Magnetic Resonance diffusometry. Comparison of the results obtained in this study with the published earlier results on an OIPC with a completely different structure (Diethyl(methyl)(isobutyl)phosphonium Hexafluorophosphate [P 1,2,2,4 ][PF 6 ]) revealed strong similarities in ion dynamics in both systems. Unlike DC conductivity, which may drop more than ten times between melted and solid phases, diffusion of anions and cations remains high and does not show strong changes at phase transition. The conductivity spectra in the broad frequency range demonstrate unusual shapes in solid phases with an additional step separating fast local ion motions from suppressed long-range charge diffusion controlling DC conductivity. We suggested that in solid phases, anions and cations can jump only between the specific ion sites defined by the crystalline structure. These constraints lead to strong cation-cation and anion-anion correlations strongly suppressing long-range charge transport.

36 MATERIALS SCIENCE↗

Noise in Intense Electron Bunches (Final Technical Report)

The goal of this project is to investigate density fluctuations in electron bunches. Noise and density fluctuations in relativistic electron bunches, accelerated in a linac, are of critical importance to various Coherent Electron Cooling (CEC) concepts as well as to free-electron lasers (FELs). For CEC, the beam noise results in additional diffusion that counteracts cooling; and if this noise is not controlled at sufficiently low level, the noise heating effects can overcome cooling. There have been several proposals in the past to suppress the noise in the beam in the frequency range of interest in order to optimize the cooling effects. In SASE FELs a microwave instability starts from the initial noise in the beam and eventually leads to the beam microbunching yielding coherent radiation, and the initial noise in the FEL bandwidth plays a useful role. In seeded FELs, in contrast, such noise interferes with the seed signal, so that reducing noise at the initial seed wavelength would lower the seed laser power requirement. Our major goals were (1) to measure the electron beam density noise level in a 0.5 – 10 um wavelength range, (2) to predict the beam noise level in order to compare with the measurements, and (3) as a stretch goal, to find mechanisms that affect the beam noise to control its level in a predictable manner.

43 PARTICLE ACCELERATORS↗

Passive Wireless Sensors for Realtime Temperature and Corrosion Monitoring of Coal Boiler Components Under Flexible Operation (Final Technical Report)

Researchers at West Virginia University (WVU) propose to demonstrate inexpensive wireless, high-temperature sensors for real-time monitoring of the temperature and corrosion of metal components, which are commonly used in coal-fired boilers. This study presents the development of cost-effective wireless high-temperature sensors for real-time temperature and corrosion monitoring in coal-fired boilers' metal components. The focus is on fabricating and evaluating chipless radio-frequency identification (RFID) sensors capable of operating between 25-1300 ºC. Efforts were directed towards designing passive RFID sensor and interrogator antenna with a broad frequency range, optimizing a microstrip patch antenna sensor integrated into a "peel-and-stick" format for efficient application to various metal specimens without altering their geometry. Additionally, this research aimed to assess the sensor responses under accelerated high-temperature conditions, correlating corrosion and cracking mechanisms with sensor data. An investigation of through-wall data acquisition techniques was also planned, facilitating unobtrusive monitoring of sensor responses housed within metal enclosures. Ultimately, this work sought to establish a robust passive wireless sensor system for the continuous health monitoring of metal components in operational settings, thereby contributing to enhanced safety and efficiency in coal-fired power plants.

20 FOSSIL-FUELED POWER PLANTS↗

A Dark Photon Dark Matter Search with a Widely-Tunable SRF Cavity

The SERAPH (SupERconducting Axion and Paraphoton Haloscope) experiment is a family of superconducting haloscopes being developed by the Superconducting Quantum Materials and Systems (SQMS) Center to search for wavelike dark matter. This presentation will focus on preliminary results from our dark photon dark matter search using a widely-tunable SRF cavity operating between 4-7 GHz, nicknamed the “plunger cavity.” I will present the cavity design and characterization, analyze the impact of microphonics on system performance and haloscope sensitivity, and describe our tuning methodology for this Q~10^8 cavity. The presentation will cover our haloscope analysis approach and discuss sensitivity limits achieved within this frequency range. Finally, I will outline lessons learned from this first search, implications for future axion searches, and proposed improvements for subsequent SERAPH experiments.

Cervantes, Raphael [Fermilab]↗

Advancing Tunnel Detection Via Vertical Acoustic Profiling

This study demonstrates that placing an acoustic source at depth significantly enhances the detection of tunnels. By adapting the methodology of vertical seismic profiling to acoustic-range frequencies, we introduce a novel approach for tunnel detection. To our knowledge, this report documents the first application of this technique. The field study was conducted on a cleared site at the Oak Ridge National Laboratory; the subsurface was clay. A series of vertical shafts were bored immediately before and after the placement of a 40 ft long, 3 ft diameter steel pipe located 10 ft below the surface. Acoustic signatures were produced at various depths up to 30 ft and an array of surface geophones was used to collect the resulting signals. The innovation lies in using subsurface acoustic signatures to better enable the collection of wide-angle diffracted waves by surface geophones. These diffracted waves appear as subharmonic frequencies of the source signal and are recorded by a surface geophone array. While the concept draws from vertical seismic profiling used in oil and gas exploration, a key distinguishing feature is the use of acoustic frequencies, which are necessary for detecting small subsurface features. The findings have important implications. Critical information pertaining to diffracted source signals are not measured by current state-of-the-art methods. Although this study confirms enhanced detectability, accurate localization and imaging will require additional research. Future work should focus on leveraging diffracted-wave strength and time delays to enable full imaging and characterization.

47 OTHER INSTRUMENTATION↗

FAIR Data and Interpretable AI Framework for Architectured Metamaterials (Final Report)

This research program established a transformative framework for the discovery and design of mechanical metamaterials, which are architected structures engineered to control physical phenomena like sound and vibration in ways natural materials cannot. To overcome the traditional reliance on trial-and-error, the project developed an interpretable Artificial Intelligence (AI) framework that moves beyond "black box" models to reveal the specific geometric patterns—such as "unit-cell templates"—that govern a material’s performance. A major breakthrough was the development of a hierarchical design method, which allows a single material to block vibrations across multiple frequency ranges simultaneously by layering patterns at different scales without them interfering with one another. This was further expanded to include irregular, graph-based designs that use spanning tree algorithms to ensure structural connectivity while allowing for customized, direction-dependent properties like stiffness and acoustic impedance. Beyond design, the project addressed the practicalities of real-world production by developing uncertainty quantification techniques that account for manufacturing defects and material variability, reducing the need for expensive physical testing by orders of magnitude. To speed up the discovery process, the team implemented Gaussian Process Regression and other surrogate models that provide accurate performance predictions at a fraction of the traditional computational cost. The AI-generated designs were successfully validated through fabrication of physical samples and wave propagation experiments, confirming their ability to accurately guide or reflect waves as predicted. By contributing these tools and high-quality FAIR benchmark datasets to the wider scientific community, this work provides a scalable foundation for advancing technologies in aerospace vibration control, medical imaging, and noise reduction.

36 MATERIALS SCIENCE↗

AI-Assisted Conceptual Development of a Pre-Geometric Cosmological Model - An Exercise in AI-Assisted Conceptual Framework Generation, Paper III: Cosmological Structure and Predictions

This paper develops the cosmological consequences of the replication-driven cosmogenesis framework introduced in Paper I and the emergent geometric structure established in Paper II. After the replication epoch freezes out, the coherent sector occupies a finite spectral band and contains a population of excited states. The relaxation of these excited coherent configurations does not produce coherent radiation; instead, all released energy flows into the incoherent substrate, where the randomizer acts as a rapid phase-scrambling mechanism. This process generates an effectively thermal radiation bath, providing a natural reheating mechanism that requires neither inflaton oscillations nor scalar-field potentials, and can be contrasted with standard scenarios of nonperturbative reheating dynamics. Subsequent symmetry-breaking transitions in the coherent vacuum inject additional radiation, yielding a multi-stage thermal history with well-defined energy transfers. We derive the effective equations of state for each component—the cosmological vacuum, the coherent vacuum, and the radiation bath—and show how their interplay produces an FRW-like expansion. The discrete sequence of coherent-state relaxations imprints a distinctive multi-peaked stochastic gravitational-wave background, whose spectral structure reflects the underlying hierarchy of coherent frequencies. Potential observational signatures in the LISA and mid-band frequency ranges are highlighted, providing concrete avenues to test this replication-based cosmological framework in the context of standard cosmological gravitational-wave backgrounds and LISA-oriented forecasts.

79 ASTRONOMY AND ASTROPHYSICS↗

A Dark Photon Dark Matter Search with a Widely-Tunable SRF Cavity

The SERAPH (SupERconducting Axion and Paraphoton Haloscope) experiment is a family of superconducting haloscopes being developed by the Superconducting Quantum Materials and Systems (SQMS) Center to search for wavelike dark matter. This presentation will focus on preliminary results from our dark photon dark matter search using a widely-tunable SRF cavity operating between 4-7 GHz, nicknamed the "plunger cavity." I will present the cavity design and characterization, analyze the impact of microphonics on system performance and haloscope sensitivity, and describe our tuning methodology for this Q~10^8 cavity. The presentation will cover our haloscope analysis approach and discuss sensitivity limits achieved in this frequency range. Finally, I will outline lessons learned from this first search, implications for future axion searches, and proposed improvements for subsequent SERAPH experiments.

Cervantes, Raphael [Fermilab]↗

Quantum-Enhanced Dark-Matter Sensing with Large Photon Number Fock States in a High-Q SRF Cavity

Wave-like dark matter candidates such as axions or dark photons in the microwave frequency range can be probed using resonant superconducting cavities. We demonstrate a quantum-enhanced sensing approach based on a multimode, high-Q superconducting RF (SRF) cavity, where a large Fock state is prepared in the storage mode via sideband transitions mediated by a transmon ancilla and a measurement-based feedforward protocol, achieving high-fidelity Fock states [1]. The prepared |n⟩ state induces stimulated emission from the dark-matter field, providing an (n + 1) enhancement in transition probability and proportional boost in signal rate [2]. A secondary cavity mode functions as an in-situ reference to calibrate noise. We present the control sequence, noise-referencing strategy, and projected sensitivity improvements for axion and dark-photon detection. This multimode architecture combines large Fock state preparation with noise calibration, offering a practical path to increased scan rate in cavity-based dark-matter searches.

Kim, Taeyoon↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino, Rafael [Unlisted]↗

Bulk viscosity of two-flavor color superconducting quark matter in neutron star mergers

This work investigates the bulk viscosity of warm, dense, neutrino-transparent, color-superconducting quark matter, where damping of density oscillations in the kHz frequency range arises from weak-interaction-driven direct Urca processes involving quarks. We study the two-flavor red-green paired color-superconducting (2SC) phase, while allowing for the presence of unpaired strange quarks and blue color light quarks of all flavors. Our calculations are based on the SU(3) Nambu–Jona–Lasinio model, extended to include both vector interactions and the ‘t Hooft determinant term. The primary focus is on how variations in the NJL Lagrangian parameters—specifically, the diquark and vector coupling strengths—affect both the static properties of quark matter, such as its equation of state and composition, and its dynamical behavior, including bulk viscosity and associated damping timescales. We find that the bulk viscosity and corresponding damping timescale can change by more than an order of magnitude upon varying the vector coupling by a factor of two at high densities and by a lesser degree at lower densities. This sensitivity primarily arises from the susceptibility of 2SC matter, with a smaller contribution from modifications to the weak interaction rates. In comparison, changes in the diquark coupling have a more limited impact. The damping of density oscillations in 2SC matter is similar quantitatively to nucleonic matter and can be a leading mechanism of dissipation in merging hybrid stars containing color superconducting cores.

Gravitational Waves↗

WEC-Sim Modeling of Laminar Scientific's Patented Seesaw Wave Energy Converter: Preprint

Laminar Scientific's patented seesaw wave energy converter was modeled in WEC-Sim to predict performance. The device operates by utilizing ocean surface waves to rotate a truss in pitch about a pivot. The pivot is located at the top of two pylons, which are embedded in the seafloor. The seesaw has a float on either end, and the buoyancy forces from each float cause the system to rise or fall with passing waves. Device performance relies upon seesaw length and ocean wavelength creating an antiphase effect. The seesaw truss has an adjustable length intended to achieve this effect. The operation method enforces a narrow band of wavelengths which induce the largest rotational motion from the device. The hydrodynamic analysis of the device was performed using Capytaine, and the results confirmed that the device operates best in a narrow frequency band. Four float-to-float spacing cases and three pylon radii were examined. The hydrodynamic results indicate a match between the model and the physical expectations for the device, and that varying the pylon radii by 0.1-m increments for three instances creates minimal changes in hydrodynamic properties. Power matrices for three float spacing cases of the device were simulated with Joint North Sea Wave Project spectra waves and optimal power take-off damping in WEC-Sim. The maximum average power production for the 15-m spacing case was 14.1 kW with a 5.0-s peak wave period and 4-m significant wave heights. Plots of capture-width ratios indicated that the device performance was linear and confirmed that the device is optimal in a narrow frequency band. The maximum percentage of the available wave power produced by the 15-m device was approximately 16%. Simulations of the device in regular waves were used to produce plots of average power compared to a ratio of float spacing to wavelength. These plots indicate that the power production is maximized at a ratio of 0.5, and further confirm that the device has a narrow frequency response. The device was simulated at an example field location, where the device produced an annual average power rating of 1.6 kW given an average omnidirectional wave climate of 10.3 kW m-1 and an optimal, linearized power take-off model. While the maximum predicted device performance is reliant upon a narrow band of wave frequencies, the conducted analysis provides an opportunity to improve device design prior to prototyping and testing. Modifying the design to respond to a broader frequency range would improve device performance.

numerical modeling↗