Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency regulation control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) for Monitoring and Control of Medium Voltage Distribution Systems with High Penetration of Intermittent Distributed Energy Resources

The primary focus of the SIMPLE project was to develop, commission, test and introduce intelligent voltage and current sensor platform with enhanced characteristics (accuracy, bandwidth and harmonic range) and high measurement granularity for medium voltage distribution system monitoring, protection and control. The enhancements incorporated existing (commercially available) sensors and made them suitable for applications such as voltage regulation, frequency support, fault detection and location, distribution system state estimation, power quality measurements and electrical distribution network topology processing. The development of the intelligent sensor platform was driven by the need for high-fidelity monitoring and control of medium voltage distribution feeder to enable higher penetration of renewable resources and microgrid operation.

14 SOLAR ENERGY↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

Artificial Intelligence-Driven Management of Sustainable Energy Resources: Visibility, Operation, and Control

The rapid global transition toward sustainable energy resources (SERs) is reshaping how modern power systems are observed, optimized, and controlled. While SERs have significantly advanced decarbonization, their weather dependence, variability, and inverter-dominated characteristics challenge traditional, centralized, and deterministic grid operation. At the same time, the proliferation of high-resolution data from inverters, smart meters, and sensors offers unprecedented visibility into system dynamics. Yet, it also exceeds the analytical capability of conventional model-based approaches. Artificial intelligence (AI) provides a new foundation for addressing these challenges by bridging physical laws with data-driven learning, enabling accurate state awareness, adaptive operation, and coordinated control across distributed assets. This article examines how AI transforms the management of SER-rich power systems along three critical dimensions: 1) enhancing visibility by inferring behind-the-meter (BTM) activities, assessing SER flexibility, and reconstructing system states from sparse or noisy measurements; 2) improving operation through AI-enhanced SER service provision, volt/var control (VVC), and dynamic operating envelopes (DOE) for efficiency and security; and 3) advancing control by embedding learning-based intelligence into inverter coordination, voltage and frequency regulation, and long-term dispatch. Together, these developments reveal how AI can convert the variability of SERs from an operational challenge into a source of flexibility, resilience, and intelligence, paving the way toward sustainable, adaptive, and self-optimizing power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SpinQuest Polarized Target System

The SpinQuest experiment at Fermilab uses a solid-state polarized ammonia target held at a magnetic field of 5 T, immersed in liquid helium-4, which is held at approximately 1K by the evaporation refrigerator. The refrigerator provides the required cooling power during the dynamic nuclear polarization (DNP) process and the high intensity interaction with the 120 GeV proton beam from the Fermilab main injector. The refrigerator was designed in compliance with the American Society of Mechanical Engineers (ASME) to operate safely at Fermilab. The high pumping capacity ($17,000 \:m^3/h$) roots stack provides the required pumping speed during DNP production data taking and a custom-made radiation hard flow control valve regulates the refrigerator temperature during the thermal equilibrium calibration measurements. The frequency of the microwave generator, an Extended Interaction Oscillator (EIO), is automated to keep the maximum polarization while the (Nuclear Magnetic Resonance) NMR system continuously measures the polarization of the target material. In this talk, an overview of the SpinQuest polarized target system will be presented as well as a brief report of recent commissioning activities and target performance during the early production runs in 2024.

Bandara, Vibodha [Colombo U.]↗

Spool valve cycles at controlled frequency

Spool valve accurately controls the cycle of a pneumatically-actuated system over long periods. Regulation of pressure from the external source, positioning of the adjusting plugs, and magnet selection, together afford wide variation in cyclic timing and speed of closure in either direction.

Charlton, K. W.↗

Accurate Consensus-based Distributed Averaging with Variable Time Delay in Support of Distributed Secondary Control Algorithms

We report that distributed secondary control has been widely used in hierarchical control structures, where multiple distributed generators (DGs) need to coordinate to regulate system voltage and frequency. In these systems, consensus algorithms determine the average of a group of dynamic states (e.g. voltages measured by a group of DGs). To be useful, consensus algorithms must be computationally efficient, stable and accurate. In practice, numerous practical implementation challenges significantly affect the consensus equilibrium. In this paper, we quantify the accuracy deviations of the distributed average observer algorithms proposed in the literature to demonstrate the problems with the state-of-the-art distributed averaging techniques. A novel approach is proposed that achieves accurate average tracking in the presence of time-varying communication delays among agents. In our implementation, time synchronization of all distributed controllers is enabled by a novel software platform, called Resilient Information Architecture Platform for the Smart Grid (RIAPS). The proposed distributed average observer is implemented on hardware controllers and its effectiveness is validated in a controller hardware-in-the-loop testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Injection Based HVDC Attack-Defense Control Via Squeeze-Excitation Double CNN

Due to the independent controllability and fast power regulation capability, the High Voltage Direct Current (HVDC) system could be a prospective technology to provide multiple ancillary services to the system besides conventional bulk power transmission. However, with the increase of False Data Injection Attacks (FDIAs) on PMU data, the HVDC system could have the wrong response once the collected data that the HVDC system relied on is attacked, thus threatening the system operating security. How to ensure the security of the PMU-based HVDC ancillary service control become an urgent issue. To mitigate the risk, this paper proposed an HVDC attack-defense control based on the FDIAs detection method. Firstly, the Squeeze-Excitation based Double Convolutional Neural Networks (SE-DCNN) is proposed to realize fast identification of the attacking frequency type based on the time and frequency domain signals. Furthermore, the duration time of FDIAs is detected by the local outlier factor. Then, utilizing the results from SE-DCNN, HVDC ancillary service control framework is reorganized and an HVDC attack defense control is proposed for suppressing the potential influence of various types of FDIAs on the HVDC system ancillary service. Different experiments results demonstrate that the proposed method has the ability to significantly mitigate the frequency deviation and oscillation under the FDIA.

42 ENGINEERING↗

Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems

This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.

Fernandes, Arnold Anthony [ORNL] (ORCID:0009000631↗

A Hardware-in-the-Loop Experimental Testbed Using Air Conditioners for Grid Balancing

Driven by the need to offset the variability of renewable generation on the grid, development of load control is a highly active field of research. However, practical use of residential loads for grid balancing remains rare, in part due to the cost of communicating with large numbers of small loads and also the limited experimentation done so far to demonstrate reliable operation. To establish a basis for the safe and reliable use of fleets of compressor loads as distributed energy resources, we constructed an experimental testbed in a laboratory, so that load coordination schemes could be tested at extreme conditions. Here, this experimental testbed was used to tune a simulation testbed to which it was then linked, thereby augmenting the effective size of the fleet. Modeling of the system was done both to demonstrate the experimental testbed's behavior and also to understand how to tune the behavior of each load. Implementing this testbed has enabled rapid turnaround of experiments on various load control algorithms, and year-round testing without the constraints and limitations arising in seasonal field tests with real houses. Experimental results show the practical feasibility of an ensemble of small loads contributing to grid balancing.

Air Conditioners↗

Small Hydropower Plant Response Improvement Using Energy Storage

Small hydropower plants contribute significantly to global power generation. However, due to limited storage, these can have low ramping capacity and poor load-frequency regulation. These can prevent small hydropower plants from being used in isolated grids as backup power to critical loads and rural areas. In this paper, a control architecture for frequency control is proposed that facilitates the use of energy storage to improve the response of standalone small hydropower plants. The frequency controller generates power commands using proportional control on frequency deviation and a user-defined power setpoint, and this incorporates with a current controller that facilitates power injection. The distinctive feature of the controller design is that it takes into account frequency thresholds and storage constraints to enable power injections, and it provides the capability to perform automated and manual recharge of the energy storage. Simulations using detailed nonlinear models demonstrate the improved performance of the hydropower with energy storage using the proposed controller. Automated and manual recharge and the impact of the energy storage constraints on the performance of the hydropower plant are demonstrated.

13 HYDRO ENERGY↗

Frequency response modeling and control of flexible structures: Computational methods

The dynamics of vibrations in flexible structures can be conventiently modeled in terms of frequency response models. For structural control such models capture the distributed parameter dynamics of the elastic structural response as an irrational transfer function. For most flexible structures arising in aerospace applications the irrational transfer functions which arise are of a special class of pseudo-meromorphic functions which have only a finite number of right half place poles. Computational algorithms are demonstrated for design of multiloop control laws for such models based on optimal Wiener-Hopf control of the frequency responses. The algorithms employ a sampled-data representation of irrational transfer functions which is particularly attractive for numerical computation. One key algorithm for the solution of the optimal control problem is the spectral factorization of an irrational transfer function. The basis for the spectral factorization algorithm is highlighted together with associated computational issues arising in optimal regulator design. Options for implementation of wide band vibration control for flexible structures based on the sampled-data frequency response models is also highlighted. A simple flexible structure control example is considered to demonstrate the combined frequency response modeling and control algorithms.

Bennett, William H.↗

Final Report for ARPA-E NODES "Real-Time Optimization and Control of Next-Generation Distribution Infrastructure" Project

The project examined next-generation power distribution systems with high levels of power- electronics-interfaced distributed energy resources (DERs) that include: renewable energy systems (RESs), energy-storage devices, electric vehicles, fuel cells, small-scale diesel generators, and controllable loads. The project developed a comprehensive distribution- network management framework that unifies real-time voltage and frequency control with network-wide energy management under an integrated framework. The aim of the project was to: i) systematically optimize network-wide operation and congruently regulate voltages and frequency in the face of high volatility induced by rapidly varying RES and uncontrolled loads; ii) facilitate high renewable integration beyond 50% on an energy basis; iii) meet power-quality requirements and operational constraints; and, iv) respect response, ramp- time, and hold-time requirements for synthetic frequency and regulating reserves via fast- and longer-term dynamic energy management.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilient and Cost-Effective Hybrid Li-Ion Battery Energy Storage System for Sites with Solar Generation and Electric Vehicle (EV) Charging (CRADA Final Report, CRD-19-00799)

The batteries of an energy storage system designed for multiple use-cases are traditionally selected to withstand the highest rate at which a battery is discharged relative to its maximum capacity (C-rate) and cycling requirements of the most intense use-case. However, this is not cost-effective given that the price of the batteries is strongly correlated to C-rate and cyclability. We propose to establish design guidelines for a hybrid energy storage system and test an edge controller that uses high-power and high-energy batteries for high- cyclability use cases such as frequency regulation and electric vehicle (EV) charging and low-cost batteries for low-power and low-cyclability use cases such as summer peak loads. The three main objectives of this proposal are (i) establishing sizing guidelines for such a hybrid storage system, (ii) installing a hybrid storage system in the Energy Systems Integration Facility (ESIF) sized based on those guidelines, and (iii) testing an edge controller specific for the system through hardware tests.

14 SOLAR ENERGY↗

Assessing Dynamic Behaviors in Converter- Dominated Power Systems via RMS and EMT Simulations: A Study of Hawaii’s NELHA Microgrid

The transition from conventional power systems to converter-based microgrids has significantly advanced sustainability, clean energy integration, and operational reliability. However, this paradigm shift introduces operational challenges due to the intermittent nature of renewable energy sources and the non-linear characteristics of power electronic loads, inducing voltage fluctuations and harmonic distortions that complicate voltage and frequency regulation. Accurate dynamic modeling is hypothesized to be critical for capturing such effects, enabling reliable simulation and control strategy development. This study introduces an innovative dynamic modeling framework for a real-world converter-based microgrid, utilizing both root mean square (RMS) and electromagnetic transient (EMT) simulation methods. The microgrid was modeled in DIgSILENT PowerFactory, with simulations calibrated against high-resolution field measurements from SEL-735 power quality meters. Results show that RMS simulations effectively characterize steady-state dynamics, while EMT simulations are essential for capturing high-frequency transients and non-linear effects from photovoltaic inverters and variable frequency drives (VFDs). This complementary approach provides a comprehensive understanding of microgrid behavior, providing critical insights for improving simulation accuracy, advancing protection schemes, and improving resilience in future low-inertia power networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced control techniques for modern inertia based inverters

In this research three artificial intelligent (AI)-based techniques are proposed to regulate the voltage and frequency of a grid-connected inverter. The increase in the penetration of renewable energy sources (RESs) into the power grid has led to the increase in the penetration of fast-responding inertia-less power converters. The increase in the penetration of these power electronics converters changes the nature of the conventional grid, in which the existing kinetic inertia in the rotating parts of the enormous generators plays a vital role. The concept of virtual inertia control scheme is proposed to make the behavior of grid connected inverters more similar to the synchronous generators, by mimicking the mechanical behavior of a synchronous generator. Conventional control techniques lack to perform optimally in nonlinear, uncertain, inaccurate power grids. Besides, the decoupled control assumption in conventional VSGs makes them nonoptimal in resistive grids. The neural network predictive controller, the heuristic dynamic programming, and the dual heuristic dynamic programming techniques are presented in this research to overcome the draw backs of conventional VSGs. The nonlinear characteristics of neural networks, and the online training enable the proposed methods to perform as robust and optimal controllers. The simulation and the experimental laboratory prototype results are provided to demonstrate the effectiveness of the proposed techniques.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Benchmarking Real-Time Control Platforms Using a Matlab/Simulink Coder with Applications in the Control of DC/AC Switched Power Converters

In the control of DC/AC switched power converters (SPC), one of the most important aspects to be considered is the selection of the real-time control platform. The real-time control platform must be able to meet the high performance efficiency and regulation requirements of the DC/AC SPC, as these typically operate at switching frequencies in the order of kHz to MHz. For this reason, the hardware characteristics of the ADC and PWM, and the processing capacity of the real-time control platform are of vital importance when implementing advanced digital controllers that maintain voltage and current levels within regulatory standards. In this context, we aimed to perform a comparative study of the computation times of different real-time control platforms when implementing different control strategies for DC/AC switched power converters. We also analyzed the impact of the real-time control platforms on the THD of the voltages generated by the DC/AC switched power converters. With the help of this paper, researchers and developers will have criteria to select which real-time control platform to use in real-time control for DC/AC SPC applications.

42 ENGINEERING↗

A Penalty Scheme for Mitigating Uninstructed Deviation of Generation Outputs From Variable Renewables in a Distribution Market

With rapid growth of distributed renewable generation, the establishment of electricity distribution markets has attracted widespread concerns. Different from existing transmission grid-scale electricity markets, an electricity distribution market is featured by numerous small-scale prosumers, and zero marginal cost and intermittency of renewable generation units. Against this background, this paper first extends an average pricing market (APM) mechanism for pricing renewable generation outputs with zero marginal cost in the distribution network concerned. Then, to mitigate the uninstructed volatility of renewable generation outputs and power demand, a penalty scheme is proposed for deviations between the real-time demand/output and market cleared bid/offer, with frequency regulation service (FRS) from energy storage systems (ESSs) considered. It is proved that the market volatility can be well controlled within an expected limit through properly setting the penalty prices for load demand and generation output fluctuations. Also, with this mechanism a non-negative market surplus could always be attained. Case studies are carried out to demonstrate the feasibility and efficiency of the proposed distribution market mechanism and penalty scheme.

electricity distribution market↗