Search NASA⌕ Search

SEARCH · Search NASA

Results for “full width at half maximum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Defect characterization and charge transport measurements in high-resolution Ni/n-4H-SiC Schottky barrier radiation detectors fabricated on 250 μ m epitaxial layers

Advances in the growth processes of 4H-SiC epitaxial layers have led to the continued expansion of epilayer thickness, allowing for the detection of more penetrative radioactive particles. In this work, we report the fabrication and characterization of high-resolution Schottky barrier radiation detectors on 250 μm thick n-type 4H-SiC epitaxial layers, the highest reported thickness to date. Several 8 × 8 mm 2 detectors were fabricated from a diced 100 mm diameter 4H-SiC epitaxial wafer grown on a conductive 4H-SiC substrate with a mean micropipe density of 0.11 cm -2 From the Mott–Schottky plots, the effective doping concentration was found to be in the range (0.95–1.85) × 10 14 cm -3 , implying that full depletion could be achieved at ~5.7 kV (0.5 MV/cm at the interface). The current-voltage characteristics demonstrated consistently low leakage current densities of 1–3 nA/cm 2 at a reverse bias of -800 V. This resulted in the pulse-height spectra generated using a 241Am alpha source (5486 keV) manifesting an energy resolution of less than 0.5% full width at half maximum (FWHM) for all the detectors at -200 V. The charge collection efficiencies (CCEs) were measured to be 98–99% with no discernable correlation to the energy resolution. A drift-diffusion model fit to the variation of CCE as a function of bias voltage, revealed a minority carrier diffusion length of ~10 μm. Deep level transient spectroscopy measurements on the best resolution detector revealed that the excellent performance was the result of having ultralow concentrations of the order of 1011 cm-3 lifetime limiting defects—Z 1/2 and EH 6/7 .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatially resolved x-ray detection with photonic crystal scintillators

We study the self-collimation phenomenon in photonic crystals (PhC) of wide bandgap materials for ultra-fast and high spatial resolution x-ray detection. We work on various heavy inorganic scintillators: BaF 2 , GaN, ZnO, CsI:Tl, NaI:Tl, LYSO, WO 4 compounds, and plastic scintillators. Conventional scintillator detectors do not rely on a direct detection mechanism; hence, they require intricate design and fabrication processes. We offer a PhC design to observe self-collimation phenomena and overcome the ongoing spatial resolution challenges with these types of materials. We investigate the photonic band diagrams and iso-frequency contours. Fourier transforms based on finite-difference time-domain and frequency domain simulations are done for verifying and analyzing the self-collimation with the selected material. Light extraction efficiency at the PhC–air interface, depending on the truncation distance from the excitation point, is measured. Beam divergence values are calculated at 1 mm propagation distance. The vertical field profiles are obtained to observe the confinement. For the spatial resolution analysis, cross-sectional beam profiles have been examined. Furthermore, Gaussian envelopes are fitted to beam profiles for a consistent data analysis, and full-width-at-half-maximum values are considered. As a result, we theoretically prove and demonstrate the spatially resolved x-ray detection at the sub-micrometer level for a wide range of scintillator materials.

36 MATERIALS SCIENCE↗

Photophysical properties of zero-dimensional perovskites studied by PBE0 and GW+BSE methods

Due to the exceptional photophysical properties and great potential applications in solid state lighting, zero-dimensional halide perovskites with broadband emitting have recently attracted much attention. In this work, to reveal the origin of the broadband absorption and emission spectra of 0D (C 4 N 2 H 14 Br) 4 SnBr x I 6-x (x = 3), the ground state and exciton dynamics properties have been studied by hybrid PBE0 functional and the GW+BSE method. Different self-trapped excitons (STEs) are obtained, and their emission energies by PBE0 are consistent well with experimental data. By considering the vibrational broadening of emission, our calculated full width at half maximum of emission accords well with the experiment. The absorption of free exciton and STEs is also calculated by considering the quasiparticle and excitonic effect. Our results show that these light-induced trapped states can be observed by experiments, as confirmed in other similar systems by the femtosecond transient absorption spectra.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of crystalline quality of traveling heater method (THM) grown Cd0.9Zn0.1Te0.98Se0.02 crystals

Because of its excellent opto-electronic properties, CdZnTe (CZT) has been the material of choice for x- and gamma-ray detectors operable at room temperature. CZT is the leading commercially available room-temperature radiation detector material today. Although much progress has been made over the past three decades, today's CZT crystals still face certain challenges, especially the presence of the performance-limiting materials defects and the associated relatively high production cost. In this regard, CdxZn1−xTeySe1−y (CZTS) is emerging as a next-generation compound semiconductor, which overcomes some of the limitations of CZT technology for the stated applications. Here, we conducted a study to evaluate the crystalline quality of the traveling heater method grown CZTS with an optimized alloy composition, i.e., Cd0.9Zn0.1Te0.98Se0.02. The as-grown samples were evaluated by low-temperature photoluminescence (PL) spectroscopy and high-resolution x-ray diffraction using the synchrotron light source at Brookhaven National Laboratory. The full width at half maximum of both the PL and x-ray rocking curves was observed to be broadened due to the lattice disorder of the quaternary compound, eventually degrading the crystalline quality. This was consistent with density functional theory calculations.

Roy, U. N. (ORCID:0000000282089680)↗

(Cd,Mg)Te crystals for picosecond-response optical-to-x-ray radiation detectors

We demonstrate a photodetector sensitive to both optical and x-ray picosecond pulses based on our in-house grown cadmium magnesium telluride (Cd,Mg)Te single crystal. Specifically, we developed In-doped Cd0.96Mg0.04Te material and discuss its femtosecond optical photoresponse, as well as the detector performance, such as <100-pA dark current and up to 0.22-mA/W responsivity for 780-nm wavelength optical radiation. The detector exposed to Ti fluorescence (K alpha) x-ray pulses at 4.5 keV, generated by a free-electron laser beam with the central energy of 9.8 keV and <100 fs pulse width, exhibited readout-electronics-limited 200-ps full-width-at-half-maximum photoresponse, demonstrating that it is suitable for coarse timing in free-electron laser x-ray/optical femtosecond pump–probe spectroscopy applications.

Instruments & Instrumentation↗

Enhancing the electron mobility in Si-doped (010) β-Ga 2 O 3 films with low-temperature buffer layers

We demonstrate a new substrate cleaning and buffer growth scheme in β-Ga 2 O 3 epitaxial thin films using metal–organic vapor phase epitaxy (MOVPE). For the channel structure, a low-temperature (LT, 600 °C) un-doped Ga 2 O 3 buffer was grown, followed by a transition layer to a high-temperature (HT, 810 °C) Si-doped Ga 2 O 3 channel layers without growth interruption. The (010) Ga 2 O 3 Fe-doped substrate cleaning uses solvent cleaning, followed by additional hydrofluoric acid (49% in water) treatment for 30 min before the epilayer growth. This step is shown to compensate the parasitic Si channel at the epilayer–substrate interface that originates from the substrate polishing process or contamination from the ambient. From secondary ion mass spectroscopy (SIMS) analysis, the Si peak atomic density at the substrate interface is found to be several times lower than the Fe atomic density in the substrate—indicating full compensation. The elimination of the parasitic electron channel at the epi–substrate interface was also verified by electrical (capacitance–voltage profiling) measurements. In the LT-grown (600 °C) buffer layers, it is seen that the Fe forward decay tail from the substrate is very sharp, with a decay rate of ∼9 nm/dec. X-ray off-axis rocking curve ω-scans show very narrow full width at half maximum (FWHM) values, similar to the as-received substrates. These channels show record high electron mobility in the range of 196–85 cm 2 /V⋅s in unintentionally doped and Si-doped films in the doping range of 2 × 10 16 –1 × 10 20 cm −3 . Si delta-doped channels were also grown utilizing this substrate cleaning and the hybrid LT buffers. Record high electron Hall mobility of 110 cm 2 /V⋅s was measured for sheet charge density of 9.2 × 10 12 cm −2 . This substrate cleaning, combined with the LT buffer scheme, shows the potential of designing Si-doped β-Ga 2 O 3 channels with exceptional transport properties for high-performance Ga 2 O 3 -based electron devices.

Bhattacharyya, Arkka↗

Gallium oxide (Ga 2 O 3 ) energy dependent scintillation response to fast neutrons and flash gamma-rays

Gallium oxide is a newly emerged ultrawide bandgap (4.9 eV) semiconductor that is suitable as a combined electronics and radiation detection platform. We have experimentally demonstrated fast neutron and gamma-ray scintillation from Czochralski-grown β-Ga 2 O 3 in a recent series (October 2023) of experiments at the unmoderated pulsed neutron spallation source located at the Los Alamos Neutron Science Center. Using the neutron time-of-flight (TOF) technique and a fast-gated intensified CCD camera, we observed energy-dependent neutron scintillation for neutron energies ranging from 1 to 400 MeV, including the 14.1 MeV neutron energy relevant to D–T fusion. Neutron flux is quantified and calibrated by cascading the scintillator after the fission chamber, enabling a detailed analysis of temporal and energy-dependent characteristics of the scintillation events. Further, a pronounced scintillation signal from the spallation gamma flash with a temporal full width of half maximum of ~4 ns is indicative of the material’s rapid response. Neutron energy dependent scintillation is observed using the TOF method at a 22.6-m distance from the neutron source. These results highlight the possibility of developing a Ga 2 O 3 based fusion neutron diagnostic platform integrated with both scintillation and electronics functions on the integrated chip scale.

47 OTHER INSTRUMENTATION↗

The XPS of pyridine: A combined theoretical and experimental analysis

A detailed analysis of the N(1s) and C(1s) X-Ray Photoelectron Spectroscopy (XPS) is made, where the measured XPS is compared with theoretical Sudden Approximation (SA) intensities and theoretical XPS Binding Energies (BEs). There is remarkably good agreement between the theoretical predictions and the measured XPS; in particular, the different full width at half maximum values for the C(1s) and N(1s) BEs are explained in terms of unresolved C(1s) BEs for the different C atoms in pyridine. Here, this work demonstrates that the combination of theory and XPS measurements can extract analysis of the XPS relevant to the molecular electronic structure. The theory used is based on fully relativistic self-consistent field solutions of the Dirac–Coulomb Hamiltonian, and the SA is used to determine relative XPS intensities.

Binding Energies (BEs)↗

Growth and characterization of high-quality Zr doped AlN epilayers

AlN stands out for its remarkable figures of merit for electronic and photonic devices, attributed to its ultrawide bandgap of ∼6.1 eV and an exceptionally high critical field of ∼15 MV/cm. More recently, zirconium (Zr) doped AlN (AlN:Zr) has also been identified as a promising material platform for the exploration of solid-state qubits for quantum information and technology, high performance piezoelectric acoustic wave resonators, and optically triggered ultrafast power switching devices facilitated by optically activating Zr related impurities. Despite the significant potential, the ability for producing AlN:Zr epitaxial structures has yet to be established. In this study, we have achieved AlN:Zr epilayers with a high Zr doping level [NZr] of up to 1020 cm−3 using industrial standard metal-organic chemical vapor deposition growth technique. High crystalline quality of AlN:Zr was confirmed by x-ray diffraction, revealing a narrow full width at half maximum of the (002) rocking curve at 216 arcsec for 1.8 μm thick epilayers deposited on sapphire at [NZr]=1020 cm−3. Zr doping was observed to slightly increase the c-lattice constant to 4.992 Å for AlN:Zr (at [NZr]=1020 cm−3) compared to 4.980 Å for undoped AlN. X-ray photoelectron spectroscopy measurement results verified the substitution of Zr at the Al site (ZrAl). The formation of (ZrAl–VN) complexes, which are predicted to possess all the desired properties required by quantum qubits, was confirmed through optical absorption studies. The realization of high-quality AlN:Zr epilayers significantly broadens the scope of technologically significant device applications for AlN.

36 MATERIALS SCIENCE↗

Gallium oxide (Ga2O3) as a radiation detector distinguishing neutrons and gammas

Gallium oxide (Ga2O3) is a promising ultrawide bandgap semiconductor for radiation detection with the potential of integrating electronic and scintillation functions within a single crystal device. This study establishes the scintillation response of β-Ga2O3 gamma irradiation from yttrium-88 (88Y). Then, californium-252 (252Cf) is used as a spontaneous fission source of mixed neutron and gamma radiation field to measure scintillation signals. Pulse shape discrimination and constant fraction discrimination techniques were used to separate neutron and gamma interaction events. Further investigation indicates that the prompt temporal responses of β-Ga2O3 for gammas and neutrons may enable discrimination of the two by prompt pulse fitting methods, focused around the initial peak. For gamma irradiation, we observed a rise time (τr) of 2.1 ns, decay time (τd) of 9.5 ns, and a full width at half maximum (FWHM) of 6.2 ns. For neutrons, it showed a τr of 2.3 ns, a τd of 12.1 ns, 9.4 ns FWHM, and reduced peak intensity. A diamond detector exhibited a more symmetrical τr and τd for both gamma and neutron signals and therefore is less effective at discriminating between the two by this method. This draws attention to β-Ga2O3’s ability to distinguish neutron and gamma particles. These findings showcase Ga2O3’s potential as a next-generation semiconductor for applications in nuclear safety and medical imaging, where precise discrimination between neutron and gamma interactions is essential.

Valdes, D. J. (ORCID:0000000304373720)↗

Experimental study of high-energy single-pulse nanosecond discharges in pin-to-pin configuration

Single-pulse pin-to-pin nanosecond pulsed discharges in ambient air (gap distances of 3–7 mm) were investigated at high pulse energies (∼20–30 mJ deposited energy per 11 ns full width at half maximum pulse). A Michelson interferometry setup (532 nm continuous-wave laser) was employed to record time-resolved interferograms of the discharge, enabling spatially resolved calculation of the electron number density. An intensified charge-coupled device camera was used to capture the spatiotemporal evolution of the discharge (streamer formation and spark channel development), and Coherent Anti-Stokes Raman Spectroscopy (CARS) was used to measure post-discharge N 2 vibrational temperatures. Discharge current and voltage were monitored with a back-current shunt. The discharge was initiated with simultaneous cathode-directed and anode-directed streamers that bridge the gap within ∼1 ns and form a luminous, filamentary plasma channel immediately after breakdown. Laser interferometry measurements showed peak electron number densities of the order of 10 1 7–10 18 cm −3 , occurring about 15–20 ns after pulse arrival at the discharge gap. Shorter gap discharges yielded higher peak electron densities, consistent with the higher energy density in the smaller gaps. Spatially, the electron density was highest near the electrodes and decreased toward the midgap region, with 5 and 7 mm gaps exhibiting a pronounced drop in the central channel. CARS indicated initial vibrational temperatures of approximately 4000–6000 K in the spark core of ∼50 ns after the discharge onset, decaying on a ∼500 ns timescale as the plasma cooled and recombined.

Coherent anti-Stokes Raman spectroscopy↗

Ultrathin epitaxial NbN superconducting films with high upper critical field grown at low temperature

Ultrathin (5–50 nm) epitaxial superconducting niobium nitride (NbN) films were grown on AlN-buffered c-plane Al 2 O 3 by an industrial scale physical vapor deposition technique at 400°C. Both X-ray diffraction and scanning electron microscopy analysis show high crystallinity of the (111)-oriented NbN films, with a narrow full-width-at-half-maximum of the rocking curve down to 0.030°. The lattice constant decreases with decreasing NbN layer thickness, suggesting lattice strain for films with thicknesses below 20 nm. The superconducting transition temperature, the transition width, the upper critical field, the irreversibility line, and the coherence length are closely correlated to the film thickness. This work realized high quality ultrathin epitaxial NbN films by an industry-scale PVD technology at low substrate temperature, which opens up new opportunities for quantum devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET

Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fine structure of the isovector giant dipole resonance in Nd 142 – 150 and Sm 152

Inelastic proton scattering at energies of a few hundred MeV and very-forward scattering angles including 0° has been established as a tool for the study of electric-dipole strength distributions in nuclei. The present work reports a systematic investigation of the chain of stable even-mass Nd isotopes representing a transition from spherical to quadrupole-deformed nuclei. Extraction of the equivalent photo-absorption cross sections and analysis of their fine structure in the energy region of the isovector giant dipole resonance (IVGDR). Method: Proton inelastic scattering reactions of 200 MeV protons were measured at the iThemba Laboratory for Accelerator Based Sciences in Cape Town, South Africa. The scattering products were momentum-analyzed by the K600 magnetic spectrometer positioned at θ Lab = 0°. Using dispersion-matching techniques, energy resolutions of ΔE ≈ 40–50 keV (full width at half maximum) were obtained. After subtraction of background and contributions from other multipoles, the spectra were converted to photoabsorption cross sections using the equivalent virtual-photon method. Wavelet-analysis techniques are used to extract characteristic energy scales of the fine structure of the IVGDR from the experimental data. Fine structure of the IVGDR is observed even for the most deformed nuclei studied. Comparisons between the extracted experimental energy scales and those energy scales obtained from the quasiparticle-phonon model (QPM) and Skyrme separable random phase approximation (SSRPA) predictions provide insight into the role of different giant-resonance damping mechanisms. It can be seen that the scales in the spherical and most likely also in the deformed nuclei mainly result from the fragmentation of the one-particle-one-hole (1p1h) strength into several dominant transitions serving as doorway states. In cases where calculations beyond the 1p1h level are available, some impact of the spreading due to coupling of the two-particle-two-hole (2p2h) states to the 1p1h doorway states is observed. New virtual-photon absorption data for the chain of stable Nd isotopes and 152 Sm are presented, with a focus on the phenomenon of nonstatistical cross-section fluctuations, referred to as fine structure, in the energy region of the IVGDR. The wavelet-analysis techniques used allowed for the features of the fine structure to be quantified in the form of characteristic scales. Finally, comparisons between experimental results and model predictions indicate that Landau damping seems to be the main source of the fine structure in both the spherical and deformed nuclei, but calculations including 2p2h degrees of freedom would be beneficial to confirm this for the deformed cases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of the lineshape of the χ c1 (3872) state

A study of the lineshape of the χ c1 (3872) state is made using a data sample corresponding to an integrated luminosity of 3 fb –1 collected in pp collisions at center-of-mass energies of 7 and 8 TeV with the LHCb detector. Candidate χ c1 (3872) and ψ(2S) mesons from b-hadron decays are selected in the J/ψπ + π – decay mode. Describing the lineshape with a Breit-Wigner function, the mass splitting between the χ c1 (3872) and ψ(2S) states, Δm, and the width of the χ c1 (3872) state, Γ BW , are determined to be Δm=185.598 ± 0.067 ± 0.068 MeV, Γ BW = 1.39 ± 0.24 ± 0.10 MeV, where the first uncertainty is statistical and the second systematic. Using a Flatté-inspired model, the mode and full width at half maximum of the lineshape are determined to be mode = 3871.69+0.00+0.05 – 0.04–0.13 MeV, FWHM=0.22 +0.07+0.11–0.06–0.13 MeV. An investigation of the analytic structure of the Flatté amplitude reveals a pole structure, which is compatible with a quasibound D 0 D¯ *0 state but a quasivirtual state is still allowed at the level of 2 standard deviations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electronic Population Transfer via Impulsive Stimulated X-Ray Raman Scattering with Attosecond Soft-X-Ray Pulses

Free electron lasers provide a source of X-ray pulses short enough and intense enough to drive nonlinearities in molecular systems. Impulsive interactions driven by these X-ray pulses provide a way to create and probe valence electron motions with high temporal and spatial resolution. Observing these electronic motions is crucial to understand the role of electronic coherence in chemical processes. A simple nonlinear technique for probing electronic motion, impulsive stimulated X-ray Raman scattering (ISXRS), involves a single impulsive interaction to produce a coherent superposition of electronic states. In this work, we demonstrate electronic population transfer via ISXRS using broad bandwidth (5.5 eV full width at half maximum) attosecond X-ray pulses produced by the Linac Coherent Light Source (LCLS). The impulsive excitation is resonantly enhanced by the oxygen 1s &rarr; 2π* resonance of nitric oxide (NO), and excited state neutral molecules are probed with a time-delayed UV laser pulse.

74 ATOMIC AND MOLECULAR PHYSICS↗

Observation of van der Waals phonons in the single-layer cuprate ( Bi , Pb ) 2 ( Sr , La ) 2 CuO 6 + δ

Interlayer van der Waals (vdW) coupling is generic in two-dimensional materials such as graphene and transition-metal dichalcogenides, which can induce very low-energy phonon modes. Using high-resolution inelastic hard x-ray scattering, we uncover the ultralow energy phonon mode along the Cu-O bond direction in the high- T c cuprate (Bi,Pb) 2 (Sr,La) 2 ⁢CuO 6+$\delta$ (Bi2201). The energy and full-width half-maximum (FWHM) of these modes are independent of temperature, while their intensity decreases with doping in accordance with an increasing c -axis lattice parameter. Here, we compare the experimental results to first-principles density functional theory simulations and identify the observed mode as a van der Waals phonon, which arises from the shear motion of the adjacent Bi-O layers. This shows that Bi-based cuprate has vibrational properties similar to graphene and transition-metal dichalcogenides, which can be exploited to engineer novel heterostructures.

36 MATERIALS SCIENCE↗

Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging

In this paper, the imaging dose and scan time have been considered as the two major constraints for routine benchtop x-ray fluorescence computed tomography (XFCT) imaging. One way to address this issue is to acquire x-ray fluorescence (XRF) signals in parallel through a 2D array of single-crystal detectors or a pixelated detector along with the cone-beam x-ray source. To identify a detector system suitable for this purpose, a commercially available, fully spectroscopic cadmium telluride (CdTe) pixelated detector, HEXITEC (High-Energy X-ray Imaging Technology), was tested under the experimental conditions optimized for benchtop XFCT imaging of gold nanoparticles (GNPs). Specifically, two different parallel-hole stainless steel collimators were fabricated and coupled with the detector for seamless integration into our existing benchtop cone-beam XFCT system. After the detector deployment, this benchtop XFCT system was used to detect XRF photons from GNP-loaded phantoms. A pixel-merging algorithm was introduced to enhance the sensitivity of XRF photon detection thereby minimizing the scan time. The effect of pixel-level charge sharing correction algorithms was investigated within the context of benchtop XFCT imaging. The detector energy resolution, in terms of the full width at half maximum (FWHM) values at different gold K-shell XRF energies, was also determined. Of the two charge sharing correction algorithms examined, the charge sharing addition gave better sensitivity than the charge sharing discrimination (csd). On the other hand, under the current experimental conditions, the energy resolution of the HEXITEC detector was the best with the csd and estimated to be 1.56 keV FWHM at 66-69 keV photon energy. Overall, despite some degradation of the detector energy resolution (compared with typical single crystal CdTe detectors), the HEXITEC detector enabled parallel data acquisition under the experimental conditions typical of benchtop XFCT imaging and operated well within our benchtop XFCT setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗