Search NASA⌕ Search

SEARCH · Search NASA

Results for “functional Principal Component Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Noise Reduction in Low-Dose X-Ray Fluoroscopy for Image-Guided Radiation Therapy

Purpose: To improve the quality of low-dose X-ray fluoroscopic images using statistics-based restoration algorithm so that the patient fluoroscopy can be performed with reduced radiation dose. Method and Materials: Noise in the low-dose fluoroscopy was suppressed by temporal and spatial filtering. The temporal correlation among neighboring frames was considered by the Karhunen-Loeve (KL) transform (i.e., principal component analysis). After the KL transform, the selected neighboring frames of fluoroscopy were decomposed to uncorrelated and ordered principal components. For each KL component, a penalized weighted least-squares (PWLS) objective function was constructed to restore the ideal image. The penalty was chosen as anisotropic quadratic, and the penalty parameter in each KL component was inversely proportional to its corresponding eigenvalue. Smaller KL eigenvalue is associated with the KL component of lower signal-to-noise ratio (SNR), and a larger penalty parameter should be used for such KL component. The low-dose fluoroscopic images were acquired using a Varian Acuity simulator. A quality assurance phantom and an anthropomorphic chest phantom were used to evaluate the presented algorithm. Results: In the images restored by the proposed KL domain PWLS algorithm, noise is greatly suppressed, whereas fine structures are well preserved. Average improvement rate of SNR is 75% among selected regions of interest. Comparison studies with traditional techniques, such as the mean and median filters, show that the proposed algorithm is advantageous in terms of structure preservation. Conclusions: The proposed noise reduction algorithm can significantly improve the quality of low-dose X-ray fluoroscopic image and allows for dose reduction in X-ray fluoroscopy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-18C-09: Mammogram Surveillance Using Texture Analysis for Breast Cancer Patients After Radiation Therapy

Purpose: To study the feasibility of applying cancer risk model established from treated patients to predict the risk of recurrence on follow-up mammography after radiation therapy for both ipsilateral and contralateral breast. Methods: An extensive set of textural feature functions was applied to a set of 196 Mammograms from 50 patients. 56 Mammograms from 28 patients were used as training set, 44 mammograms from 22 patients were used as test set and the rest were used for prediction. Feature functions include Histogram, Gradient, Co-Occurrence Matrix, Run-Length Matrix and Wavelet Energy. An optimum subset of the feature functions was selected by Fisher Coefficient (FO) or Mutual Information (MI) (up to top 10 features) or a method combined FO, MI and Principal Component (FMP) (up to top 30 features). One-Nearest Neighbor (1-NN), Linear Discriminant Analysis (LDA) and Nonlinear Discriminant Analysis (NDA) were utilized to build a risk model of breast cancer from the training set of mammograms at the time of diagnosis. The risk model was then used to predict the risk of recurrence from mammogram taken one year and three years after RT. Results: FPM with NDA has the best classification power in classifying the training set of the mammogram with lesions versus those without lesions. The model of FPM with NDA achieved a true positive (TP) rate of 82% compared to 45.5% of using FO with 1-NN. The best false positive (FP) rates were 0% and 3.6% in contra-lateral breast of 1-year and 3-years after RT, and 10.9% in ipsi-lateral breast of 3-years after RT. Conclusion: Texture analysis offers high dimension to differentiate breast tissue in mammogram. Using NDA to classify mammogram with lesion from mammogram without lesion, it can achieve rather high TP and low FP in the surveillance of mammogram for patient with conservative surgery combined RT.

60 APPLIED LIFE SCIENCES↗

A variance-based decomposition and global sensitivity index method for uncertainty quantification: Application to retrieved ice cloud properties

This study develops a novel uncertainty quantification (UQ) method for cloud microphysical property retrievals using variance-based decomposition and global sensitivity index. In this UQ framework, empirical orthogonal function (EOF) analysis is applied to the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) ground-based observations, which are the inputs for the cloud retrieval studied here. The principal components (PCs) in the EOF expansion are parameterized as random input variables, and hence, the input dimension is greatly reduced (up to a factor of 50), allowing large ensemble of random samplings. The EOF expansion improves the accuracy of the uncertainty estimation by taking into account the cross correlations in the input data profiles. Here, this method enables a probabilistic representation of a retrieval process by adding normally distributed perturbations into PCs of sample means of input data profiles within a time window. Therefore, it effectively facilitates objective validation of climate models against cloud retrievals under a probabilistic framework for rigorous statistical inferences. Moreover, the variance-based global sensitivity index analysis, part of this method, attributes the output uncertainties to each individual source, thus providing directions for improving retrieval algorithms and observation strategies. For demonstration, we apply this method to quantify the uncertainties of the ARM program's baseline cloud retrieval algorithm for an ice cloud case observed at the Southern Great Plains site on 9 March 2000.

54 ENVIRONMENTAL SCIENCES↗

Choreographing Couch and Collimator in Volumetric Modulated Arc Therapy

Purpose: To design and optimize trajectory-based, noncoplanar subarcs for volumetric modulated arc therapy (VMAT) deliverable on both Varian TrueBEAM system and traditional accelerators; and to investigate their potential advantages for treating central nervous system (CNS) tumors. Methods and Materials: To guide the computerized selection of beam trajectories consisting of simultaneous couch, gantry, and collimator motion, a score function was implemented to estimate the geometric overlap between targets and organs at risk for each couch/gantry angle combination. An initial set of beam orientations is obtained as a function of couch and gantry angle, according to a minimum search of the score function excluding zones of collision. This set is grouped into multiple continuous and extended subarcs subject to mechanical limitations using a hierarchical clustering algorithm. After determination of couch/gantry trajectories, a principal component analysis finds the collimator angle at each beam orientation that minimizes residual target-organ at risk overlaps. An in-house VMAT optimization algorithm determines the optimal multileaf collimator position and monitor units for control points within each subarc. A retrospective study of 10 CNS patients compares the proposed method of VMAT trajectory with dynamic gantry, leaves, couch, and collimator motion (Tra-VMAT); a standard noncoplanar VMAT with no couch/collimator motion within subarcs (Std-VMAT); and noncoplanar intensity-modulated radiotherapy (IMRT) plans that were clinically used. Results: Tra-VMAT provided improved target dose conformality and lowered maximum dose to brainstem, optic nerves, and chiasm by 7.7%, 1.1%, 2.3%, and 1.7%, respectively, compared with Std-VMAT. Tra-VMAT provided higher planning target volume minimum dose and reduced maximum dose to chiasm, optic nerves, and cochlea by 6.2%, 1.3%, 6.3%, and 8.4%, respectively, and reduced cochlea mean dose by 8.7%, compared with IMRT. Tra-VMAT averaged beam-on time was comparable to Std-VMAT but significantly (45%) less than IMRT. Conclusion: Optimized couch, gantry, and collimator trajectories may be integrated into VMAT with improved mechanical flexibility and may provide better dosimetric properties and improved efficiency in the treatment of CNS tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Indirect dark matter signatures in the cosmic dark ages. I. Generalizing the bound on s -wave dark matter annihilation from Planck results

Recent measurements of the cosmic microwave background (CMB) anisotropies by Planck provide a sensitive probe of dark matter annihilation during the cosmic dark ages, and specifically constrain the annihilation parameter f eff <σv>=m χ . Using new results (paper II) for the ionization produced by particles injected at arbitrary energies, we calculate and provide f eff values for photons and e + e - pairs injected at keV-TeV energies; the f eff value for any dark matter model can be obtained straightforwardly by weighting these results by the spectrum of annihilation products. This result allows the sensitive and robust constraints on dark matter annihilation presented by the Planck collaboration to be applied to arbitrary dark matter models with s-wave annihilation. Here, we demonstrate the validity of this approach using principal component analysis. As an example, we integrate over the spectrum of annihilation products for a range of Standard Model final states to determine the CMB bounds on these models as a function of dark matter mass, and demonstrate that the new limits generically exclude models proposed to explain the observed high-energy rise in the cosmic ray positron fraction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multivariate analysis of progressive thermal desorption coupled gas chromatography-mass spectrometry.

Thermal decomposition of poly dimethyl siloxane compounds, Sylgard{reg_sign} 184 and 186, were examined using thermal desorption coupled gas chromatography-mass spectrometry (TD/GC-MS) and multivariate analysis. This work describes a method of producing multiway data using a stepped thermal desorption. The technique involves sequentially heating a sample of the material of interest with subsequent analysis in a commercial GC/MS system. The decomposition chromatograms were analyzed using multivariate analysis tools including principal component analysis (PCA), factor rotation employing the varimax criterion, and multivariate curve resolution. The results of the analysis show seven components related to offgassing of various fractions of siloxanes that vary as a function of temperature. Thermal desorption coupled with gas chromatography-mass spectrometry (TD/GC-MS) is a powerful analytical technique for analyzing chemical mixtures. It has great potential in numerous analytic areas including materials analysis, sports medicine, in the detection of designer drugs; and biological research for metabolomics. Data analysis is complicated, far from automated and can result in high false positive or false negative rates. We have demonstrated a step-wise TD/GC-MS technique that removes more volatile compounds from a sample before extracting the less volatile compounds. This creates an additional dimension of separation before the GC column, while simultaneously generating three-way data. Sandia's proven multivariate analysis methods, when applied to these data, have several advantages over current commercial options. It also has demonstrated potential for success in finding and enabling identification of trace compounds. Several challenges remain, however, including understanding the sources of noise in the data, outlier detection, improving the data pretreatment and analysis methods, developing a software tool for ease of use by the chemist, and demonstrating our belief that this multivariate analysis will enable superior differentiation capabilities. In addition, noise and system artifacts challenge the analysis of GC-MS data collected on lower cost equipment, ubiquitous in commercial laboratories. This research has the potential to affect many areas of analytical chemistry including materials analysis, medical testing, and environmental surveillance. It could also provide a method to measure adsorption parameters for chemical interactions on various surfaces by measuring desorption as a function of temperature for mixtures. We have presented results of a novel method for examining offgas products of a common PDMS material. Our method involves utilizing a stepped TD/GC-MS data acquisition scheme that may be almost totally automated, coupled with multivariate analysis schemes. This method of data generation and analysis can be applied to a number of materials aging and thermal degradation studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Statistical Shape Modeling of Cam Femoroacetabular Impingement

In this study, statistical shape modeling (SSM) was used to quantify three-dimensional (3D) variation and morphologic differences between femurs with and without cam femoroacetabular impingement (FAI). 3D surfaces were generated from CT scans of femurs from 41 controls and 30 cam FAI patients. SSM correspondence particles were optimally positioned on each surface using a gradient descent energy function. Mean shapes for control and patient groups were defined from the resulting particle configurations. Morphological differences between group mean shapes and between the control mean and individual patients were calculated. Principal component analysis was used to describe anatomical variation present in both groups. The first 6 modes (or principal components) captured statistically significant shape variations, which comprised 84% of cumulative variation among the femurs. Shape variation was greatest in femoral offset, greater trochanter height, and the head-neck junction. The mean cam femur shape protruded above the control mean by a maximum of 3.3 mm with sustained protrusions of 2.5-3.0 mm along the anterolateral head-neck junction and distally along the anterior neck, corresponding well with reported cam lesion locations and soft-tissue damage. This study provides initial evidence that SSM can describe variations in femoral morphology in both controls and cam FAI patients and may be useful for developing new measurements of pathological anatomy. SSM may also be applied to characterize cam FAI severity and provide templates to guide patient-specific surgical resection of bone.

statistical shape modeling↗

Simulation methodology for fuel assembly drop accident during handling

Fresh and irradiated fuel assembly handling is a routine part of Nuclear Power Plant activities. Fuel Assembly handling occurs during fresh fuel receipt, core refueling, spent fuel assemblies transfer from spent fuel pool to the storage containers, etc. Westinghouse, ENUSA and KEPCO-NF have collaborated in the technical area of Fuel Assembly Drop Accident (FADA) Simulation to update the approach for estimating the number of failed fuel rods as a consequence of a fresh or irradiated fuel assembly drop, which might occur during a handling accident in a PWR-type reactor. The proposed FADA simulation methodology starts with an assessment of fuel assembly impact velocity at the final stage of the drop in water or air. The vertical, horizontal or inclined drop directions are considered. This velocity is an input to determine a fuel assembly structural response during impact which defines the loading function for the fuel assembly components including spacer grids. The dynamic load on the fuel rod is calculated from the detailed spacer grid model and the corresponding loading function. Finally, the load from the spacer grid spring and dimples are applied to the fuel rod model to determine the cladding parameters for use in compliance to fuel rod cladding failure criteria. A combination of first principal, finite element analysis (FEA) and computational fluid dynamic (CFD) methods has been utilized to create a technically sound methodology. A number of specific and traditional tests for the fuel assembly and its components has been used to confirm that the proposed approaches which describe the physical phenomena related to the fuel assembly drop accident are reasonably conservative.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Star/galaxy separation at faint magnitudes: Application to a simulated Dark Energy Survey

We address the problem of separating stars from galaxies in future large photometric surveys. We focus our analysis on simulations of the Dark Energy Survey (DES). In the first part of the paper, we derive the science requirements on star/galaxy separation, for measurement of the cosmological parameters with the Gravitational Weak Lensing and Large Scale Structure probes. These requirements are dictated by the need to control both the statistical and systematic errors on the cosmological parameters, and by Point Spread Function calibration. We formulate the requirements in terms of the completeness and purity provided by a given star/galaxy classifier. In order to achieve these requirements at faint magnitudes, we propose a new method for star/galaxy separation in the second part of the paper. We first use Principal Component Analysis to outline the correlations between the objects parameters and extract from it the most relevant information. We then use the reduced set of parameters as input to an Artificial Neural Network. This multi-parameter approach improves upon purely morphometric classifiers (such as the classifier implemented in SExtractor), especially at faint magnitudes: it increases the purity by up to 20% for stars and by up to 12% for galaxies, at i-magnitude fainter than 23.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Star/galaxy separation at faint magnitudes: application to a simulated Dark Energy Survey

We address the problem of separating stars from galaxies in future large photometric surveys. We focus our analysis on simulations of the Dark Energy Survey (DES). In the first part of the paper, we derive the science requirements on star/galaxy separation, for measurement of the cosmological parameters with the gravitational weak lensing and large-scale structure probes. These requirements are dictated by the need to control both the statistical and systematic errors on the cosmological parameters, and by point spread function calibration. We formulate the requirements in terms of the completeness and purity provided by a given star/galaxy classifier. In order to achieve these requirements at faint magnitudes, we propose a new method for star/galaxy separation in the second part of the paper. We first use principal component analysis to outline the correlations between the objects parameters and extract from it the most relevant information. We then use the reduced set of parameters as input to an Artificial Neural Network. This multiparameter approach improves upon purely morphometric classifiers (such as the classifier implemented in SExtractor), especially at faint magnitudes: it increases the purity by up to 20 per cent for stars and by up to 12 per cent for galaxies, at i-magnitude fainter than 23.

79 ASTRONOMY AND ASTROPHYSICS↗

Kernel principal component analysis for stochastic input model generation

Highlights: {yields} KPCA is used to construct a reduced order stochastic model of permeability. {yields} A new approach is proposed to solve the pre-image problem in KPCA. {yields} Polynomial chaos is used to provide a parametric stochastic input model. {yields} Flow in porous media with channelized permeability is considered. - Abstract: Stochastic analysis of random heterogeneous media provides useful information only if realistic input models of the material property variations are used. These input models are often constructed from a set of experimental samples of the underlying random field. To this end, the Karhunen-Loeve (K-L) expansion, also known as principal component analysis (PCA), is the most popular model reduction method due to its uniform mean-square convergence. However, it only projects the samples onto an optimal linear subspace, which results in an unreasonable representation of the original data if they are non-linearly related to each other. In other words, it only preserves the first-order (mean) and second-order statistics (covariance) of a random field, which is insufficient for reproducing complex structures. This paper applies kernel principal component analysis (KPCA) to construct a reduced-order stochastic input model for the material property variation in heterogeneous media. KPCA can be considered as a nonlinear version of PCA. Through use of kernel functions, KPCA further enables the preservation of higher-order statistics of the random field, instead of just two-point statistics as in the standard Karhunen-Loeve (K-L) expansion. Thus, this method can model non-Gaussian, non-stationary random fields. In this work, we also propose a new approach to solve the pre-image problem involved in KPCA. In addition, polynomial chaos (PC) expansion is used to represent the random coefficients in KPCA which provides a parametric stochastic input model. Thus, realizations, which are statistically consistent with the experimental data, can be generated in an efficient way. We showcase the methodology by constructing a low-dimensional stochastic input model to represent channelized permeability in porous media.

97 MATHEMATICS AND COMPUTING↗

A limited-angle intrafraction verification (LIVE) system for radiation therapy

Purpose: Currently, no 3D or 4D volumetric x-ray imaging techniques are available for intrafraction verification of target position during actual treatment delivery or in-between treatment beams, which is critical for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments. This study aims to develop a limited-angle intrafraction verification (LIVE) system to use prior information, deformation models, and limited angle kV-MV projections to verify target position intrafractionally. Methods: The LIVE system acquires limited-angle kV projections simultaneously during arc treatment delivery or in-between static 3D/IMRT treatment beams as the gantry moves from one beam to the next. Orthogonal limited-angle MV projections are acquired from the beam's eye view (BEV) exit fluence of arc treatment beam or in-between static beams to provide additional anatomical information. MV projections are converted to kV projections using a linear conversion function. Patient prior planning CT at one phase is used as the prior information, and the on-board patient volume is considered as a deformation of the prior images. The deformation field is solved using the data fidelity constraint, a breathing motion model extracted from the planning 4D-CT based on principal component analysis (PCA) and a free-form deformation (FD) model. LIVE was evaluated using a 4D digital extended cardiac torso phantom (XCAT) and a CIRS 008A dynamic thoracic phantom. In the XCAT study, patient breathing pattern and tumor size changes were simulated from CT to treatment position. In the CIRS phantom study, the artificial target in the lung region experienced both size change and position shift from CT to treatment position. Varian Truebeam research mode was used to acquire kV and MV projections simultaneously during the delivery of a dynamic conformal arc plan. The reconstruction accuracy was evaluated by calculating the 3D volume percentage difference (VPD) and the center of mass (COM) difference of the tumor in the true on-board images and reconstructed images. Results: In both simulation and phantom studies, LIVE achieved substantially better reconstruction accuracy than reconstruction using PCA or FD deformation model alone. In the XCAT study, the average VPD and COM differences among different patient scenarios for LIVE system using orthogonal 30° scan angles were 4.3% and 0.3 mm when using kV+BEV MV. Reducing scan angle to 15° increased the average VPD and COM differences to 15.1% and 1.7 mm. In the CIRS phantom study, the VPD and COM differences for the LIVE system using orthogonal 30° scan angles were 6.4% and 1.4 mm. Reducing scan angle to 15° increased the VPD and COM differences to 51.9% and 3.8 mm. Conclusions: The LIVE system has the potential to substantially improve intrafraction target localization accuracy by providing volumetric verification of tumor position simultaneously during arc treatment delivery or in-between static treatment beams. With this improvement, LIVE opens up a new avenue for margin reduction and dose escalation in both fractionated treatments and SRS and SBRT treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Data Analytics Applied to Coal Fired Boilers for Detecting Leaks

Data analytics were used to detect boiler leaks from five different coal-fired boilers including both subcritical and supercritical systems. Discriminant functions were developed that detected leaks up to two weeks prior to forced plant shutdowns for repairs. The leaks were identified to occur at different sections of the boiler for each plant, including waterwalls, economizer and superheater using conventional process measurement data. Leaking conditions were detected with a high degree of confidence (&NestedLessLess; 1% misclassified observations) and were able to distinguish normal operations from those time periods with steam leaks even while operating the power plants in power cycling mode.Multivariable statistical analyses, including Principal Component (PCA), cluster, and Fischer Discriminant Analysis (FDA) were used to characterize the leak occurrence. Normal and operational states with steam leaks were provided in the original process datasets. These datasets were split into two different groups for training and validation purposes. The data were sorted chronologically, and every third observation was assigned to training the Discriminant Function Model (DFM) while the rest were reserved for validation. PCA was used to reduce dimensionality of the original datasets. Canonical and FDA analyses were used to investigate the relationship between process variables. The outcome of the analyses revealed that nearly 35,000 observations were classified correctly; less than 0.05% of total observations were misclassified to be leaking, i.e. both false positives and false negatives.

Indrawan, Natarianto↗

A hierarchical analysis of the impact of methodological decisions on statistical downscaling of daily precipitation and air temperatures

Despite the widespread application of statistical downscaling tools, uncertainty remains regarding the role of model formulation in determining model skill for daily maximum and minimum temperature (Tmax and Tmin), and precipitation occurrence and intensity. Impacts of several key aspects of statistical transfer function form on model skill are evaluated using a framework resistant to model overspecification. We focus on: (a) model structure: simple (generalized linear models, GLMs) versus complex (artificial neural networks, ANNs) models. (b) Predictor selection: Fixed number of predictors chosen a priori versus stepwise selection of predictors and inclusion of grid point values versus predictors derived from application of principal components analysis (PCA) to spatial fields. We also examine the influence of domain size on model performance. For precipitation downscaling, we consider the role of the threshold used to characterize a wet day and apply three approaches (Poisson and Gamma distributions in GLM and ANN) to downscale wet-day precipitation amounts. While no downscaling formulation is optimal for all predictands and at 10 locations representing diverse U.S. climates, and due to the exclusion of variance inflation all of the downscaling formulations fail to reproduce the range of observed variability, models with larger suites of prospective predictors generally have higher skill. For temperature downscaling, ANNs generally outperform GLM, with greater improvements for T min than T max . Furthermore, use of PCA-derived predictors does not systematically improve model skill, but does improve skill for temperature extremes. Model skill for precipitation occurrence generally increases as the wet-day threshold increases and models using PCA-derived predictors tend to outperform those based on grid cell predictors. Each model for wet-day precipitation intensity overestimates annual total precipitation and underestimates the proportion derived from extreme precipitation events, but ANN-based models and those with larger predictor suites tend to have the smallest bias.

54 ENVIRONMENTAL SCIENCES↗

Designing clay-polymer nanocomposite sorbents for water treatment: A review and meta-analysis of the past decade

Clay-polymer nanocomposites (CPNs) have been studied for two decades as sorbents for water pollutants, but their applicability remains limited. Our aim in this review is to present the latest progress in CPN research using a meta-analysis approach and identify key steps necessary to bridge the gap between basic research and CPN application. Based on results extracted from 99 research articles on CPNs and 8 review articles on other widely studies sorbents, CPNs had higher adsorption capacities for several inorganic and organic pollutant classes (including heavy metals, oxyanions, and dyes, n = 308 observations). We applied principal component analysis, analysis of variance, and multiple linear regressions to test how CPN and pollutant properties correlated with Langmuir adsorption model coefficients. While adsorption was, surprisingly, not influenced by mineral properties, it was influenced by CPN fabrication method, polymer functional groups, and pollutant properties. For example, among the pollutant classes, heavy metals had the highest adsorption capacity but the lowest adsorption affinity. Conversely, dyes had high adsorption affinities, as reflected by the linear correlation between adsorption affinity and pollutant molecular weight. Scaling from ‘basic research’ to ‘technological application’ requires testing CPN performance in real water, application in columns, comparison to commercial sorbents, regeneration, and cost evaluation. However, our survey indicates that of the 158 observations, only 20 compared the CPN's performance to that of a commercial sorbent. We anticipate that this review will promote the design of smart and functional CPNs, which can then evolve into an effective water treatment technology.

42 ENGINEERING↗

Principal shapes and squeezed limits in the effective field theory of large scale structure

We apply an orthogonalization procedure on the effective field theory of large scale structure (EFT of LSS) shapes, relevant for the angle-averaged bispectrum and non-Gaussian covariance of the matter power spectrum at one loop. Assuming natural-sized EFT parameters, this identifies a linear combination of EFT shapes—referred to as the principal shape—that gives the dominant contribution for the whole kinematic plane, with subdominant combinations suppressed by a few orders of magnitude. For the covariance, our orthogonal transformation is in excellent agreement with a principal component analysis applied to available data. Additionally we find that, for both observables, the coefficients of the principal shapes are well approximated by the EFT coefficients appearing in the squeezed limit, and are thus measurable from power spectrum response functions. Employing data from N-body simulations for the growth-only response, we measure the single EFT coefficient describing the angle-averaged bispectrum with Ο (10%) precision. These methods of shape orthogonalization and measurement of coefficients from response functions are valuable tools for developing the EFT of LSS framework, and can be applied to more general observables.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Efficient Stochastic Inversion Using Adjoint Models and Kernel-PCA

Performing stochastic inversion on a computationally expensive forward simulation model with a high-dimensional uncertain parameter space (e.g. a spatial random field) is computationally prohibitive even with gradient information provided. Moreover, the ‘nonlinear’ mapping from parameters to observables generally gives rise to non-Gaussian posteriors even with Gaussian priors, thus hampering the use of efficient inversion algorithms designed for models with Gaussian assumptions. In this work, we propose a novel Bayesian stochastic inversion methodology, characterized by a tight coupling between a gradient-based Langevin Markov Chain Monte Carlo (LMCMC) method and a kernel principal component analysis (KPCA). This approach addresses the ‘curse-of-dimensionality’ via KPCA to identify a low-dimensional feature space within the high-dimensional and nonlinearly correlated spatial random field. Moreover, non-Gaussian full posterior probability distribution functions are estimated via an efficient LMCMC method on both the projected low-dimensional feature space and the recovered high-dimensional parameter space. We demonstrate this computational framework by integrating and adapting recent developments such as data-driven statistics-on-manifolds constructions and reduction-through-projection techniques to solve inverse problems in linear elasticity.

97 MATHEMATICS AND COMPUTING↗

An initial study on the estimation of time-varying volumetric treatment images and 3D tumor localization from single MV cine EPID images

Purpose: In this work the authors develop and investigate the feasibility of a method to estimate time-varying volumetric images from individual MV cine electronic portal image device (EPID) images. Methods: The authors adopt a two-step approach to time-varying volumetric image estimation from a single cine EPID image. In the first step, a patient-specific motion model is constructed from 4DCT. In the second step, parameters in the motion model are tuned according to the information in the EPID image. The patient-specific motion model is based on a compact representation of lung motion represented in displacement vector fields (DVFs). DVFs are calculated through deformable image registration (DIR) of a reference 4DCT phase image (typically peak-exhale) to a set of 4DCT images corresponding to different phases of a breathing cycle. The salient characteristics in the DVFs are captured in a compact representation through principal component analysis (PCA). PCA decouples the spatial and temporal components of the DVFs. Spatial information is represented in eigenvectors and the temporal information is represented by eigen-coefficients. To generate a new volumetric image, the eigen-coefficients are updated via cost function optimization based on digitally reconstructed radiographs and projection images. The updated eigen-coefficients are then multiplied with the eigenvectors to obtain updated DVFs that, in turn, give the volumetric image corresponding to the cine EPID image. Results: The algorithm was tested on (1) Eight digital eXtended CArdiac-Torso phantom datasets based on different irregular patient breathing patterns and (2) patient cine EPID images acquired during SBRT treatments. The root-mean-squared tumor localization error is (0.73 ± 0.63 mm) for the XCAT data and (0.90 ± 0.65 mm) for the patient data. Conclusions: The authors introduced a novel method of estimating volumetric time-varying images from single cine EPID images and a PCA-based lung motion model. This is the first method to estimate volumetric time-varying images from single MV cine EPID images, and has the potential to provide volumetric information with no additional imaging dose to the patient.

60 APPLIED LIFE SCIENCES↗