Search NASA⌕ Search

SEARCH · Search NASA

Results for “gas meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Conceptual design for a blanket tritium extraction test stand

Tritium breeding is fundamentally required for a sustainable fusion fuel cycle, yet the technological readiness of blanket technology lags far behind other fusion systems. Breeder concepts are divided into solid and liquid media, where solid breeders typically rely on a sweep gas, such as helium, to carry away tritium from lithium containing ceramic materials, and liquid breeders produce tritium from lithium containing eutectics (e.g., PbLi) or molten salts (FLiBe). In each case, tritium must be harvested from the breeding medium. A promising method for tritium extraction is through a vacuum permeator, in which a concentration gradient from the tritium- containing fluid promotes diffusion through a membrane with high hydrogen permeability to the vacuum. This technology has been demonstrated for hydrogen gas systems using Pd and PdAg permeators, but relatively little work has been done to test tritium extraction from PbLi. A Tritium Extraction eXperimental (TEX) loop is being designed to test tritium extraction in a vacuum permeator configuration. The system design is such that it will allow the testing of tritium extraction from both helium and PbLi. A phased approach is being taken that will allow testing of small specimens for fundamental permeation measurements, to multi-meter component testing at near-prototypic conditions. A molten PbLi loop is challenging due to the toxic and explosive nature of Pb and Li, respectively, radiological concerns by introducing tritium, and high temperatures involved in such a system. In addition, PbLi corrosion is a significant issue at high temperatures (>400C). The TEX system will not employ a neutron source for volumetric production of tritium. Herein we present the design and methods used for 1) pumping PbLi, 2) introducing deuterium or tritium into the PbLi, 3) quantifying the amount of deuterium in the loop, 4) extracting deuterium and tritium, and 5) quantifying the total amount of extracted deuterium or tritium from the permeator. In addition, the safety design for operating such a system will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combined Cycle Integrated Thermal Energy Storage “CiTES” (Final Scientific/Technical Report)

The Phase I of this project confirmed the technical feasibility of a Combined Cycle integrated Thermal Energy Storage “CiTES” system, calculated the key performance parameters like power efficiency and costs, and proved its commercial value with full-year simulations for several US electricity markets with high degree of variable renewable generation and volatile hourly electricity prices. The core element of this project is the Electro Thermal Energy Storage (ETES) technology from Siemens Gamesa Renewable Energy GmbH, using thermally stable and inexpensive volcanic rocks as storage material and air as heat transfer medium. This technology is backed by more than 10 years of experience and a 440MMBTU (130MWh-th) pilot plant in Hamburg, Germany, which is in operation since 2019. The integration of this thermal storage in an existing combined cycle power plant (CCPP) is typical power plant technology without any major technology risks. It allows the storage of inexpensive renewable energy during times of surplus renewable generation and the discharge of this energy in times of high energy demand when the fossil plant is in operation. This supplements the fossil power generation with CO2-emission-free energy. The secondary effect of the CiTES system is that a small part of the stored thermal energy is used to keep the heat recovery steam generator (HRSG) and steam turbine (ST) of the combined cycle power plant in hot and ready-to-start condition. This enables the plant to start rapidly when fossil generation is required to satisfy demand as soon variable generation drops off in the evenings or during cloud cover and calm wind periods. Without pre-warming of the HRSG and ST, the CCPP would need several hours for a cold or warm start, burn a lot of gas and release high NOx emissions during start and wouldn’t be able to use the short times of high energy prices in an efficient or economical manner. The economic parameters of CiTES were determined by a full year “8760” simulation using a data set calculation for each of the hours of the year, and historical electricity and gas prices. For consistency, the simulations were focused on the pre-COVID year 2019. The financially most attractive markets were in the Energy Reliability Council of Texas (ERCOT) region, which allowed substantial value generation with arbitrage (charge with cheap energy during renewable surplus times and discharge when energy is needed and expensive). The improvement of flexibility with the CiTES system by pre-heating and warm-keeping of the CCPP allowed for additional power generation during short time periods when demand is high but renewable generation is down; when the hourly energy prices are highest in these markets. The simulations are based on 2019 data, when ERCOT had 27GW of installed photovoltaic (PV) and wind generation. They showed that the created revenue with the prototypically sized CiTES system of 1,000MMBTU (300MWh-th) falls a little bit short of what is expected from a commercially viable investment. The system has optimization opportunities for cost reduction and increased effectiveness which will be realized during a potential Phase II Pre-FEED study following this project. Furthermore, it is safe to assume that a lot of renewable generation capacity will be added all over the US in the coming years. As an example, ERCOT is predicting to more than double its renewable generation from 27GW in 2019 to a forecasted 63GW in 2023. This will increase the amount of renewable overproduction exponentially. This rapid increase of local overproduction and the need to curtail renewable generation is well documented by the California ISO (www.CAISO.com / managing oversupply). However, the simulations also revealed a weakness in the structure of the electricity markets in the US. More specifically, when electricity prices are very low and approaching negative levels, the owners of Variable Renewable Energy (VRE) will curtail a part of their facility to stabilize the price by reducing supply. This results in a situation in which storage facilities, which are integrated in existing fossil assets and don’t have the behind-the-meter benefit of a VRE, won’t be able to purchase low cost – otherwise curtailed – renewable energy off the grid. A special tariff, which motivates VRE owners to sell otherwise curtailed renewable energy to storage facilities (Hydrogen, thermal, pumped hydro, etc.) can solve this issue. The implementation of such a regulating tariff by Independent System Operators, thus avoiding renewable curtailment, is a pre condition for successful commercialization for renewable energy storage technologies. With this advancement of design and technology and improvements in the market environment, it can be expected that the Combined Cycle integrated Thermal Energy Storage proves itself as an important innovation to keep highly efficient, natural gas-based power generation economically successful and relevant for the power industry in the United States of America.

Wolf, Thorsten↗

Preliminary design of a helium cryogenic system for SAND detector at LBNF-DUNE near site

The Long-Baseline Neutrino Facility (LBNF) is providing a helium cryogenic system to support the superconducting solenoid magnet of the System for on-Axis Neutrino Detection (SAND) for the Deep Underground Neutrino Experiment (DUNE) Near Site at Fermilab in Batavia, IL. The design started in 2020 and construction is set to begin in the mid 2020‘s.The helium cryogenic system primarily consists of a helium refrigerator system, distribution valve boxes, vacuum-jacketed helium and nitrogen transfer lines, warm gaseous helium transfer system, instruments and control system, and gaseous helium storage tanks. It is designed to provide supercritical helium at around 3 bara and 5 K with expansion from 3 to 1.2 bara in the SAND cryostat and 70K forced cold gas helium to cool the thermal shields of the SAND cryostat. The SAND superconductive magnet is indirectly cooled through a liquid helium thermosiphon cycle. A pair of 3 kA leads is cooled by the gas helium vaporized from the liquid helium reservoir in the cryostat turret. The helium system will share the liquid nitrogen tank and liquid nitrogen phase separator with the Near Site Liquid Argon system. The helium recycle compressor system, GHe tanks and LN2 tank will be located on the Surface. The cryogenic facilities including refrigerator cold box, valve boxes and LN2 phase separator will be located on the shaft cryo-mezzanine in the underground cavern. The shaft connecting surface and cavern is more than 60 meter deep. The helium vacuum-jacketed transfer line between the cold box and the SAND magnet is more than 50 meter long. This paper presents the preliminary design of the helium cryogenic system including the design scheme, process flow diagram, heat load estimates, layout plan and so on.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

From models to reality: a systematic review on simulated and measured residential heat pump energy savings

High-performance HVAC solutions are central to residential energy management. A substantial share of these are electric, reversible-cycle systems, with heat pumps representing the largest portion of current and near-term adoption. This review synthesizes peer-reviewed and grey literature on residential space heating and cooling heat pumps. The academic literature is dominated by modeling (73.8%), with limited field measurement (13.1%). Grey literature from United States serve as a supplemental resource providing measured savings. Conversions from electric-resistance heating consistently show the largest site energy reductions, while oil/propane baselines yield moderate savings, and gas baseline scenario often deliver small and region-dependent savings. This study cross-checks the grey literature measured data with simulation data filtered from the ResStock dataset. The comparison indicates a discrepancy between simulations and measured data: simulated site EUIs are typically lower than measured EUIs, but percentage energy savings fall in similar ranges, implying simulations capture directional effects while underestimating energy use. Factors associated with variability and model–measurement differences include system characterization and control representation (e.g., backup heat engagement, thermostat/setpoint strategies, commissioning/installation quality), occupant behavior, weather normalization, metering scope, and envelope characterization. This paper also outlines the proposed methodology for comparing simulation and measured data for heat pumps. It emphasizes the metrics used for comparison and units harmonization, building characteristics matching, and compact metadata are needed for simulations to match measured data. The proposed methodology is expected to improve the credibility of simulated savings as measured evidence grows.

Yu, Lili↗

Effects of Rapid Permafrost Thaw on CO2 and CH4 Fluxes in a Warmer and Wetter Future (Final Technical Report)

When ice-rich permafrost thaws, the ground subsides, creating thermokarst landscapes with dramatically different soil conditions and carbon fluxes than the original ecosystem. Roughly 20% of the northern permafrost region is susceptible to thermokarst formation (Olefeldt et al., 2016). Thermokarst formation is often rapid; tens of meters of permafrost can thaw within a few years (Schuur et al., 2015). In topographically low areas, thermokarst thaw converts boreal forest or tundra dry shrub ecosystems into sedge or Sphagnum moss wetlands (Olefeldt et al., 2016). While this type of landscape transformation releases carbon stored in permafrost into the atmosphere, on longer time scales, it facilitates sequestration of atmospheric carbon in plant biomass because permafrost thaw releases plant-available nutrients and wetlands are highly productive (M. C. Jones et al., 2017). However, wetlands also generate methane, which is a potent greenhouse gas. Methane emissions from thermokarst wetlands can cause these carbon-sequestering systems to have a positive global warming potential (Johansson et al., 2006; Turetsky et al., 2007). Our project objective was to improve Earth System and environmental predictability by advancing understanding of how CO 2 and CH 4 flux in permafrost thaw-induced wetlands (thermokarst) will change in the future as temperatures and climate conditions shift. Northern latitudes are expected to get warmer and wetter (IPCC 2013), and initiation and expansion of thermokarst thaw is expected to increase (Jorgenson et al. 2006; Zhang et al. 2017). Given these expected changes, our work sought to address three broad questions: Q1) How will northern latitude CO2 and CH4 emissions respond to warming temperatures? Q2) What is the impact of precipitation on permafrost thaw and carbon emissions? Q3) How do CO2 and CH4 emissions change as wetlands age after permafrost thaw? To answer these questions, we took both a modeling and measurement approach. Modeling work was conducted with DOE’s Energy Exascale Earth System Model (E3SM) land model (ELM). Empirical work took place in two primary locations. The first was a thermokarst site near Fairbanks, AK. The site is part of the Bonanza Creek Long Term Ecological Research program and is well instrumented (Neumann et al., 2019). The second was an isolated thawing permafrost wetland located on Kenai Peninsula — Brown’s Lake bog (B. M. Jones et al., 2016) — where the current climate is representative of what is expected at higher latitudes in the future. This site provides an ideal opportunity to test our hypotheses about how thermokarst wetland dynamics will respond to future environmental conditions. In addition, the project collaborated with researchers asking similar questions who were collecting measurements in high latitude post-glacial lakes located in collaborators tackling similar questions in Sweden (Stordalen Mire) (Emerson et al., 2021). Project efforts directly aligned with the stated goal of the funding opportunity announcement (FOA), which was “to improve the understanding and representation of terrestrial ecosystems in ways that advance Earth system model parameterizations and capabilities... thereby improving the quality of Earth and environmental model projections and providing the scientific foundation needed to support DOE’s science and energy missions.” Specifically, the project improved sophistication and accuracy of the Energy Exascale Earth System Model (E3SM), which is being developed primarily at DOE National Laboratories to support scientific research and decision-making.

54 ENVIRONMENTAL SCIENCES↗

Search for electron-neutrino transitions to sterile states in the BEST experiment

The Baksan Experiment on Sterile Transitions (BEST) probes the gallium anomaly and its possible connections to oscillations between active and sterile neutrinos. Based on the Gallium-Germanium Neutrino Telescope (GGNT) technology of the SAGE experiment, BEST employs two zones of liquid Ga target to explore neutrino oscillations on the meter scale. Oscillations on this short scale could produce deficits in the 71 Ge production rates within the two zones, as well as a possible rate difference between the zones. From July 5th to October 13th 2019, the two-zone target was exposed to a primarily monoenergetic, 3.4-MCi 51 Cr neutrino source 10 times for a total of 20 independent 71 Ge extractions from the two Ga targets. The 71 Ge production rates from the neutrino source were measured from July 2019 to March 2020. At the end of these measurements, the counters were filled with 71 Ge doped gas and calibrated during November 2020. In this paper, results from the BEST sterile neutrino oscillation experiment are presented in details. The ratio of the measured 71 Ge production rates to the predicted rates for the inner and the outer target volumes are calculated from the known neutrino capture cross section. Comparable deficits in the measured ratios relative to predicted values are found for both zones, with the 4⁢𝜎 deviations from unity consistent with the previously reported gallium anomaly. Finally, if interpreted in the context of neutrino oscillations, the deficits give best-fit oscillation parameters of Δ⁢𝑚 2 = 3.3$^{+∞}{−2.3}$ eV 2 and sin 2 ⁡2⁢𝜃 = 0.42$^{+0.15}{−0.17}$, consistent with 𝜈 𝑒 →𝜈 𝑠 oscillations governed by a surprisingly large mixing angle.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Non-Invasive Approach for Elucidating the Spatial Distribution of In-Situ Stress in Deep Subsurface Geologic Formations Considered for CO 2 Storage (Final Report)

The primary objectives of this project were to: develop a new, non-invasive method to define the orientation and magnitude of in-situ stresses in deep geologic formations (depths that exceed 1500 meters) considered for carbon dioxide (CO 2 ) sequestration; to demonstrate the method at a real field site; and, to extend current technical capabilities and reduce costs of acquiring information about deep-stress fields. This investigation was segmented into five tasks, including Project Management (Task 1) and four technical tasks (Tasks 2 through 5). The results of the technical tasks are described in this document.

02 PETROLEUM↗

Scaling Containment on a Large Centrifuge

Containment science concerns the trapping or leakage of radioactive cavity gases from underground nuclear explosions (UNEs). The most physically relevant data for validation of containment science comes from legacy UNE testing or large field-scale chemical explosions. Field-scale tests can inform on the degree of residual stress imparted to host geology and possible formation of an accompanying gas-containing “stress cage”, for example, as a function of chemical explosion yield. However, field testing can be expensive, difficult to conduct, and challenging to instrument with limitations on data coverage (i.e., the number of boreholes; difficult coring through damage zones). Small-scale laboratory tests are typically simpler to conduct and more thoroughly characterize, but may not include the right scale of containment processes for stress-cage or chimney formation. This report presents the theory and fundamentals of large centrifuge physical modeling, including a history of explosive or similar testing relevant to containment science investigations on centrifuges. Subscale models with embedded chemical explosives in the enhanced gravity of a large centrifuge can represent hundreds of meters of depth and large explosions not otherwise attainable in the laboratory as based on scaling of length, energy, and other processes by the g-factor of the centrifuge (i.e., the number of times larger the centrifugal force is than the gravitational force on the Earth’s surface). The centrifuge uniquely joins the simplicity and exhaustiveness of laboratory-scale characterization with the physics of field-scale processes. This report is part of Sandia National Laboratories’ (SNL’s) effort to prepare for physical modeling with approximately one-meter tall geologic models of stress cage and/or chimney formation on its 29-foot [8.84 m] radius centrifuge with a load capacity of 1.6 million 𝑔-pounds [726 𝑔-ton]. The scaling relationships herein will inform model design decisions and performance requirements for in-flight sensors.

42 ENGINEERING↗

Trace Gases, Meteorological Parameters, and GPS data for TRACER-MAP

This dataset includes trace gas, meteorological, and GPS measurements made on Mobile Air Quality Laboratory 2 (MAQL2) for the TRACER-MAP sampling campaign. Trace gas measurements include nitric oxide (NO), nitrogen dioxide (NO2), reactive nitrogen compounds (NOy), ozone (O3), sulfur dioxide (SO2), and carbon monoxide (CO). All trace gases are in units of ppbv, excluding CO which is in ppmv. The dataset also includes the photolysis rate of NO2 (jNO2), latitude and longitude, wind speed (WS), wind direction (WD), ambient relative humidity (RH), ambient pressure (press), and ambient temperature (temp). Units for trace gases are in parts per billion (ppbv), latitude and longitude are in decimal degrees (dd), jNO2 is in per second (per sec), pressure is in millibar (mbar), relative humidity is in percent, the temperature is in degrees C, wind direction is in degrees, and wind speed is in meters per second. All data is 5 minutes averaged.

54 ENVIRONMENTAL SCIENCES↗

The Effects of Channel Supplies on Overall Film-Cooling Effectiveness

Abstract Cooling components in the hot section of a gas turbine are essential to component durability. Common methods of cooling include rib turbulators in internal passages and film cooling on external surfaces. The holes that produce the film cooling are fed from the internal channels often containing ribs. Consequently, there is an interdependence of internal heat transfer and external film cooling. The purpose of this study was to obtain a better understanding of the interaction of ribs and film cooling. To quantify the cooling performance, the surface temperatures were measured, from which overall effectiveness was calculated. For the experiments, additively manufactured test coupons were made of Inconel 718 to match engine Biot numbers. These test coupons had internal feed channels with and without ribs and had both cylindrical holes and meter-diffuser-shaped holes with 15 deg lateral expansion angles and a 1 deg forward expansion angle. A single rectangular channel was one type of feed channel. The other type of feed channel was individual circular channels, with each circular channel supplying an individual film-cooling hole. The experimental results showed that the circular individual channels have 80% higher baseline overall effectiveness than the single rectangular channels without any film cooling. Ribbed turbulators without film cooling also increased the overall effectiveness by 21% for single rectangular channels and by 29% for the circular individual channels compared to the respective non-ribbed channels. While the film cooling increased the overall effectiveness of all geometries, the single rectangular channels had increased overall effectiveness levels by up to twice that of the no film-cooling case. On average, the single rectangular channels had an 80% improvement from film cooling, whereas the individual channel feeds, on average, had only a 50% improvement, given their high baseline effectiveness levels.

Engineering↗

NDX: Neutron Dose Rate Meters with Extended Capabilities

Particle accelerators, irradiation facilities, and nuclear power plants would benefit from using neutron dose rate meters featuring improved energy response covering full range of expected neutron energies, improved dynamic range of measured dose rates while providing the real-time data, and improved ability to operate in harsh radiation environments including heavy photon backgrounds and pulsed beams. The novel design of the neutron moderator for the NDX dose rate meter implements a layer of a Beryllium-loaded medium Z material which, similar to the earlier known WENDI detectors, allows the device to detect higher energy neutron flux and convert it to dose. Using Beryllium helps to fill the known dip in the response functions around 5-50 MeV. Optimized design parameter set, obtained using FLUKA Monte Carlo simulations, features the NDX moderator made of polyethylene embedding a layer of BeCu alloy inside, with the dose rate response constant within ±10% in the neutron energy range from about 100 keV to 500 MeV, and ±25% essentially in the full energy range above thermal. A new sensor technique implemented in the NDX is based on using the Ionization Chamber (IC) filled with 3He gas to capture the moderated neutron fluence, and includes a symmetric IC filled with regular 4He to evaluate the contributions due to the non-neutron ionizing radiation. Advantages of the method include large accessible dynamic range, relative insensitivity of the IC probes to photon radiation fields, and the ability to subtract their contribution. Two prototype NDX detectors were built, calibrated, and operated in various conditions at the CEBAF 12 GeV electron accelerator at JLab. The first results showed reliable neutron dose rate measurements in the presence of overwhelming photon radiation fields, and at practical high dose rate levels of up to approximately 10 Sv/h. Detector design, operation, first results, and further development plans are presented.

Degtiarenko, Pavel V.↗

A Miniature Multilevel Structures for Lossless Ion Manipulations Ion Mobility Spectrometer with Wide Mobility Range Separation Capabilities

Here, ion mobility spectrometry employing structures for lossless ion manipulations (SLIM-IMS) is an attractive gas-phase separation technique due to its ability to achieve unprecedented effective ion path lengths (>1 km) and IMS resolving powers in a small footprint. The emergence of multilevel SLIM technology, where ions are transferred between vertically stacked SLIM electrode surfaces, has subsequently allowed for ultralong single pass path lengths (>40 m) to be achieved, enabling ultrahigh resolution IMS measurements to be performed over the entire mobility range in a single experiment. The implementation of multiple SLIM levels requires very little additional space for the SLIM system, and we developed a miniature SLIM module (miniSLIM) based on multilevel SLIM technology and report the performance here. The module is 11.1 cm x 6.7 cm x 1.4 cm (L x W x H) and consists of three SLIM levels totaling 1-meter path length. Ion trajectory simulations were used to optimize the SLIM board spacings and SLIM board thicknesses of the miniSLIM IMS system. Methods of efficiently transferring ions between SLIM levels were examined and a new approach using asymmetric traveling waves (TWs) was developed and implemented in the miniSLIM. We experimentally characterized the performance of the --meter multilevel miniSLIM IMS-MS relative to a drift tube IM--MS using an Agilent tuning mixture and tetraalkylammonium cations. The 1-meter miniSLIM achieved a resolving power of up to 131 (CCS/ΔCCS), ~1.5x higher than achievable with a 78 cm path length drift tube IMS, and successfully transmitted the entire ion mobility range in a single separation. We also demonstrated the miniSLIM’s performance as a standalone IMS system (i.e., without MS), showing baseline separation between Agilent tuning mixture cations with the full mobility range observed, and a standard peptide mixture with different charge states readily differentiated. Overall the miniSLIM provides a compact alternative to high performance IMS instruments possessing similar path lengths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calculating Behind-the-Meter Energy Storage Incentives on an Avoided Cost Basis

Behind-the-meter (BTM) energy storage offers the potential for shared investment by utilities and their customers, in which both parties share in the costs and benefits of battery investment. Several utilities and a handful of states have begun providing incentives to help customers purchase BTM energy storage, and in exchange, operate that battery on behalf of the customer to realize grid benefits such as meeting peak capacity needs. But there is wide variation in the value and structure of these incentives, suggesting a lack of clarity on the value of BTM storage to the grid and to non-participating customers who fund the incentives for participating customers. This paper provides an objective framework for establishing BTM energy storage incentives based on the avoided cost of generation from a marginal, gas-fired peaking plant. It also conducts several sensitivity analyses to see how those avoided costs vary with emissions pricing, gas prices, plant heat rates, and utility capital structures. This work may be of use to utilities, regulators, and energy system stakeholders in providing a value-based framework for BTM incentive programs that can be used in the absence of policy guidance.

Twitchell, Jeremy B.↗

Blodgett Forest CA Warming Experiment Soil Gas Well Data March 2014 to June 2017

These are soil gas data from the whole soil profile warming experiment at the University of California Blodgett Forest Research Station, in the Sierra Nevada foothills near Georgetown, CA at 1370 m above sea level. Mean annual precipitation is 1774 mm with most of it occurring from November through April and mean annual temperature is about 12.5°C . The experiment is in a thinned 80-year-old stand of mixed conifers including ponderosa pine (Pinus ponderosa), sugar pine (Pinus lambertiana), incense cedar (Calodefrus decurrens), white fir (Abies concolor), and douglas fir (Pseudotsuga menziesii). The soils are Holland series: fine-loamy, mixed, superactive, mesic Ultic Haploxeralfs of granitic origin with thick, >5 cm O horizons, minimal carbonates , and a pH that ranges from 5.6 to 6.5. The warming experiment warms the top meter of the soil profile to +4°C above ambient. These data include depth-resolved measurements of CO2 concentrations, 13CO2, apparent respiration quotients, soil temperature, and soil moisture (VWC). These data can be used to model CO2 production rates across the soil profile or to track how the sources and processes contributing to soil respiration change seasonally and with warming.

13C↗

Snowmass2021 CMB-HD White Paper

CMB-HD is a proposed millimeter-wave survey over half the sky that would be ultra-deep (0.5 uK-arcmin) and have unprecedented resolution (15 arcseconds at 150 GHz). Such a survey would answer many outstanding questions about the fundamental physics of the Universe. Major advances would be 1.) the use of gravitational lensing of the primordial microwave background to map the distribution of matter on small scales (k~10 h Mpc^(-1)), which probes dark matter particle properties. It will also allow 2.) measurements of the thermal and kinetic Sunyaev-Zel'dovich effects on small scales to map the gas density and velocity, another probe of cosmic structure. In addition, CMB-HD would allow us to cross critical thresholds: 3.) ruling out or detecting any new, light (< 0.1 eV) particles that were in thermal equilibrium with known particles in the early Universe, 4.) testing a wide class of multi-field models that could explain an epoch of inflation in the early Universe, and 5.) ruling out or detecting inflationary magnetic fields. CMB-HD would also provide world-leading constraints on 6.) axion-like particles, 7.) cosmic birefringence, 8.) the sum of the neutrino masses, and 9.) the dark energy equation of state. The CMB-HD survey would be delivered in 7.5 years of observing 20,000 square degrees of sky, using two new 30-meter-class off-axis crossed Dragone telescopes to be located at Cerro Toco in the Atacama Desert. Each telescope would field 800,000 detectors (200,000 pixels), for a total of 1.6 million detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Queued Up: 2025 Edition – Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2024 [Slides]

Electric transmission system operators (ISOs, RTOs, or utilities) require proposed power plants seeking to connect to the transmission grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. The lists of projects in this process are known as “interconnection queues”. In collaboration with interconnection.fyi, Berkeley Lab compiled, aggregated, and cleaned interconnection queue data from >50 transmission grid operators (7 ISO/RTOs and 49 non-ISO balancing areas), which collectively represent ~97% of currently installed U.S. electric generating capacity. The dataset includes requests submitted to queues through the end of 2024, and only includes requests seeking to connect to the transmission grid (not distribution-connected or behind-the-meter projects). The files below include both a PDF report and an Excel data file. The PDF report analyzes interconnection data and metrics through the end of 2024. The Excel data file includes (a) the full project-level interconnection queue dataset through 2024, (b) a codebook (data dictionary) describing each data field, and (c) 35 additional tabs featuring tables summarizing a range of interconnection metrics. Key highlights from the Queued Up: 2025 Edition (featuring data through 2024) include: • As of the end of 2024, there were ~10,300 projects actively seeking grid interconnection in the U.S., representing 1,400 GW of generation and approximately 890 GW of storage. • Historic withdrawal rates alongside relatively fewer new requests resulted in a 12% decrease in total active queue volume compared to the prior year. • Active natural gas capacity (136 GW, +72% year-over-year) increased in 2024, while solar (956 GW, -12%), storage (890 GW, -13%), and wind (271 GW, -26%) capacity decreased. • 408 GW of capacity already has a draft or executed interconnection agreement (IA) but has not yet reached commercial operations. • The time projects spend in queues before reaching COD is increasing. For the regions with available data, the median duration from IR to COD has doubled from <2 years for projects built in 2000-2007 to over 4 years for those built in 2018-2024. • Ultimately, most of this proposed capacity will not be built. Only 13% of capacity that submitted interconnection requests from 2000-2019 had reached commercial operations by the end of 2024; 77% of that capacity had been withdrawn and 10% was still active. • FERC Order 2023 and various other reforms are being implemented. These are important measures to reduce interconnection bottlenecks and enhance grid system reliability, but it is too early to measure and assess their full impact. • New additions for the 2025 edition include: (a) additional detail on data processing and gaps; (b) updates on interconnection reforms; (c) new analysis on interconnection agreements, and more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Leaf-area index of Oak-Hickory Forest at Missouri Ozark (MOFLUX) site: 2007–2022

This data set contains measurements of leaf-area index (LAI) at the Missouri Ozark (MOFLUX) site during growing seasons from 2007-2022. The MOFLUX site is located in the University of Missouri Baskett Forest, a second growth oak-hickory forest situated in the Ozark Border Region of central Missouri, USA. MOFLUX is part of the AmeriFlux network (site ID: US-MOz) and an eddy covariance tower marks the middle of the site (Figure 1). During 2003, 24 circular vegetation plots (each 0.08 hectares) were established within a ~250 meter (m) radius around the tower. The plots were situated 50 m apart along 5 linear transects radiating out from the flux tower base in southeast, south, southwest, west, and northwest directions. There were 5 plots per transect except for the northwest one, which had only 4 due to the presence of a small pond at the terminus. At weekly intervals during the growing season, leaf-area index measurements were taken within each vegetation plot on the 5 transects running from the central flux tower. A plant canopy analyzer (model LAI-2000 Li-Cor Inc., Lincoln NE) was used to make the LAI measurements. We collected samples to enable measurement of the mean LAI of each transect. LAI observations are useful for understanding vegetation phenology, and to aid in the interpretation of ecosystem gas exchange. This dataset contains one data file in comma separate (.csv) format. Additional metadata are provided: one data dictionary and a file-level metadata file in comma separate (.csv) format and a user guide in PDF (*.pdf) format.

ESS-DIVE CSV File Formatting Guidelines Reporting ↗

Energy flexibility of residential buildings: A systematic review of characterization and quantification methods and applications

With building electric demand becoming increasingly dynamic, and a growing percentage of intermittent renewable power generation from solar photovoltaics and wind turbines, the power grid is facing increasing challenge to manage the real time balance between the supply and demand. With advancements in smart sensing and metering, smart appliances, electric vehicles, and energy storage technologies, demand side management of residential buildings can help the grid to improve stability by optimizing flexible loads. This paper reviews recent studies on residential building demand side management, with a focus on characterization and quantification of energy flexibility covering various types of flexible loads, metrics, methods, and applications. The reviewed studies showed four levels of applications: building level (45%), district or community level (29%), system level (19%), and building sector level (7%). Shifting loads is the dominant flexibility type in 60% of applications, followed by shedding (19%), generation (16%), and modulating (6%). Depending on the technology and application scope, flexible operations have a wide range of performance, with peak power reductions of 1%~65%, energy savings up to 60%, operational cost reduction of 1%~48%, and greenhouse gas emission reductions of up to29%. More than half (51%) of the studies employed control strategies to achieve flexibility; among those 72% used optimal controls, while 28% used rule-based controls. About 58% of the studies used mathematical formulation to quantify energy flexibility. Most studies were based on simulation, while less than 15% of the studies had measurements from experiments or field tests. The review reveals research opportunities to address significant gaps in the existing literature: (1) establishing a common definition and performance metrics for energy flexibility of buildings that are technology and application agnostic, (2) developing an ontology to standardize representation of flexibility resources for interoperability, (3) integrating occupant impacts into the quantification and optimization of energy flexibility, and (4) developing requirements and credits of energy flexibility in building energy codes and standards. Findings from the review can inform future research and development of energy flexible buildings which are essential to a reliable and resilient power grid.

Li, H↗