At least 127 records · Page 7

Magnetic particle imaging of blood coagulation

We investigated the feasibility of visualizing blood coagulation using a system for magnetic particle imaging (MPI). A magnetic field-free line is generated using two opposing neodymium magnets and transverse images are reconstructed from the third-harmonic signals received by a gradiometer coil, using the maximum likelihood-expectation maximization algorithm. Our MPI system was used to image the blood coagulation induced by adding CaCl{sub 2} to whole sheep blood mixed with magnetic nanoparticles (MNPs). The “MPI value” was defined as the pixel value of the transverse image reconstructed from the third-harmonic signals. MPI values were significantly smaller for coagulated blood samples than those without coagulation. We confirmed the rationale of these results by calculating the third-harmonic signals for the measured viscosities of samples, with an assumption that the magnetization and particle size distribution of MNPs obey the Langevin equation and log-normal distribution, respectively. We concluded that MPI can be useful for visualizing blood coagulation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A cryogen-free ultralow-field superconducting quantum interference device magnetic resonance imaging system

Magnetic resonance imaging (MRI) at microtesla fields using superconducting quantum interference device (SQUID) detection has previously been demonstrated, and advantages have been noted. Although the ultralow-field SQUID MRI technique would not need the heavy superconducting magnet of conventional MRI systems, liquid helium required to cool the low-temperature detector still places a significant burden on its operation. We have built a prototype cryocooler-based SQUID MRI system that does not require a cryogen. The SQUID detector and the superconducting gradiometer were cooled down to 3.7 K and 4.3 K, respectively. We describe the prototype design, characterization, a phantom image, and areas of further improvements needed to bring the imaging performance to parity with conventional MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizations of spin-exchange relaxation-free magnetometer based on potassium and rubidium hybrid optical pumping

The hybrid optical pumping atomic magnetometers have not realized its theoretical sensitivity, the optimization is critical for optimal performance. The optimizations proposed in this paper are suitable for hybrid optical pumping atomic magnetometer, which contains two alkali species. To optimize the parameters, the dynamic equations of spin evolution with two alkali species were solved, whose steady-state solution is used to optimize the parameters. The demand of the power of the pump beam is large for hybrid optical pumping. Moreover, the sensitivity of the hybrid optical pumping magnetometer increases with the increase of the power density of the pump beam. The density ratio between the two alkali species is especially important for hybrid optical pumping magnetometer. A simple expression for optimizing the density ratio is proposed in this paper, which can help to determine the mole faction of the alkali atoms in fabricating the hybrid cell before the cell is sealed. The spin-exchange rate between the two alkali species is proportional to the saturated density of the alkali vapor, which is highly dependent on the temperature of the cell. Consequently, the sensitivity of the hybrid optical pumping magnetometer is dependent on the temperature of the cell. We proposed the thermal optimization of the hybrid cell for a hybrid optical pumping magnetometer, which can improve the sensitivity especially when the power of the pump beam is low. With these optimizations, a sensitivity of approximately 5 fT/Hz{sup 1/2} is achieved with gradiometer arrangement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A simplified HTc rf SQUID to analyze the human cardiac magnetic field

We have developed a four-channel high temperature radio-frequency superconducting quantum interference device (HT{sub c} rf SQUID) in a simple magnetically shielded room (MSR) that can be used to analyze the cardiac magnetic field. It is more robust and compact than existing systems. To achieve the high-quality magnetocardiographic signal, we explored new adaptive software gradiometry technology constructed by the first-order axial gradiometer with a baseline of 80mm, which can adjust its performance timely with the surrounding conditions. The magnetic field sensitivity of each channel was less than 100fT/√Hz in the white noise region. Especially, in the analysis of MCG signal data, we proposed the total transient mapping (TTM) technique to visualize current density map (CDM), then we focused to observe the time-varying behavior of excitation propagation and estimated the underlying currents at T wave. According to the clear 3D imaging, isomagnetic field and CDM, the position and distribution of a current source in the heart can be visualized. It is believed that our four-channel HT{sub c} rf SQUID magnetometer based on biomagnetic system is available to detect MCG signals with sufficient signal-to-noise (SNR) ratio. In addition, the CDM showed the macroscopic current activation pattern, in a way, it has established strong underpinnings for researching the cardiac microscopic movement mechanism and opening the way for its use in clinical diagnosis.

36 MATERIALS SCIENCE↗

A practical approach to calculating magnetic Johnson noise for precision measurements

Magnetic Johnson noise is an important consideration for many applications involving precision magnetometry, and its significance will only increase in the future with improvements in measurement sensitivity. The fluctuation–dissipation theorem can be utilized to derive analytic expressions for magnetic Johnson noise in certain situations, but when used in conjunction with finite element analysis tools, the combined approach is particularly powerful as it provides a practical means to calculate the magnetic Johnson noise arising from conductors of arbitrary geometry and permeability. In this paper, we demonstrate this method to be one of the most comprehensive approaches presently available to calculate thermal magnetic noise. In particular, its applicability is shown to not be limited to cases where the noise is evaluated at a point in space but also can be expanded to include cases where the magnetic field detector has a more general shape, such as a finite-size loop, a gradiometer, or a detector that consists of a polarized atomic species trapped in a volume. Furthermore, some physics insights gained through studies made using this method are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precisely mapping the magnetic field gradient in vacuum with an atom interferometer

The magnetic field gradient has been measured with an atom interferometer using the magnetic sublevels of {sup 87}Rb atoms. The Doppler-insensitive measurement effectively eliminates the contribution from gravity and background vibration noise, and the differential measurement also can reject some systematic errors. A resolution of 300 pT/mm has been demonstrated with a 90-s integration time and a spatial resolution of 1.4 mm. The gradiometer was then used to measure the magnetic field gradient in an ultrahigh-vacuum environment. The technique will also be very useful to subtract the systematic error arising from the magnetic field inhomogeneity in precision atom-interferometry experiments, such as gravity measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization enhanced Nuclear Quadrupole Resonance with an atomic magnetometer

Nuclear Quadrupole Resonance (NQR) has been demonstrated for the detection of 14-N in explosive compounds. Application of a material specific radio-frequency (RF) pulse excites a response typically detected with a wire- wound antenna. NQR is non-contact and material specific, however fields produced by NQR are typically very weak, making demonstration of practical utility challenging. For certain materials, the NQR signal can be increased by transferring polarization from hydrogen nuclei to nitrogen nuclei using external magnetic fields. This polarization enhancement (PE) can enhance the NQR signal by an order of magnitude or more. Atomic magnetometers (AM) have been shown to improve detection sensitivity beyond a conventional antenna by a similar amount. AM sensors are immune to piezo-electric effects that hamper conventional NQR, and can be combined to form a gradiometer for effective RF noise cancellation. In principle, combining polarization enhancement with atomic magnetometer detection should yield improvement in signal-to-noise ratio that is the product of the two methods, 100-fold or more over conventional NQR. However both methods are even more exotic than traditional NQR, and have never been combined due to challenges in operating a large magnetic field and ultra-sensitive magnetic field sensor in proximity. Furthermore we present NQR with and without PE with an atomic magnetometer, demonstrating signal enhancement greater than 20-fold for ammonium nitrate. We also demonstrate PE for PETN using a traditional coil for detection with an enhancement factor of 10. Experimental methods and future applications are discussed.

47 OTHER INSTRUMENTATION↗

Four-channel optically pumped atomic magnetometer for magnetoencephalography

We have developed a four-channel optically pumped atomic magnetometer for magnetoencephalography (MEG) that incorporates a passive diffractive optical element (DOE). The DOE allows us to achieve a long, 18-mm gradiometer baseline in a compact footprint on the head. Using gradiometry, the sensitivities of the channels are < 5 fT/Hz 1/2 , and the 3-dB bandwidths are approximately 90 Hz, which are both sufficient to perform MEG. Additionally, the channels are highly uniform, which offers the possibility of employing standard MEG post-processing techniques. As a result, this module will serve as a building block of an array for magnetic source localization.

47 OTHER INSTRUMENTATION↗

Assessment of Potential Impact of Electromagnetic Fields from Undersea Cable on Migratory Fish Behavior

The US Department of Energy and US Department of the Interior, Bureau of Ocean Energy Management commissioned this study to address the limited scientific data on the impacts of high voltage direct current cables on aquatic biota, in particular migratory species within the San Francisco Bay. Empirical evidence exists that marine animals perceive and orient to local distortions in the earth’s main geomagnetic field magnetic field. The electromagnetic fields (EMF) generated by the cables that carry electricity from hydrokinetic energy sources to shore-based power stations may produce similar local distortions in the earth’s main field. Concern exists that animals that migrate along the continental shelves might orient to the EMF from the cables, and move either inshore or offshore away from their normal path. The Trans Bay Cable (TBC) is a ±200-kilovolt (kV), 400 MW 85-km long High Voltage Direct Current (DC) buried transmission line linking Pittsburg, CA with San Francisco, CA (SF) through the San Francisco Bay. The study addresses the following specific questions based on measurements and projections of the EMF produced by an existing marine cable, the TBC, in San Francisco Bay. Specifically, does the presence of EMF from an operating power cable alter the behavior and path of bony fishes and sharks along a migratory corridor? Does the EMF from an operating power cable guide migratory movements or pose an obstacle to movement? To meet the main study objectives several activities needed to be carried out: 1) modeling of the magnetic fields produced by the TBC, 2) assessing the migratory impacts on Chinook salmon smolts (Oncorhynchus tshawytscha) and green sturgeon (Acipenser medirostris) as a result of local magnetic field distortions produced by bridge structures and 3) analyzing behavioral responses by migratory Chinook salmon and green sturgeon to a high-voltage power cable. To meet the first objective, magnetic field measurements were made using two submerged Geometrics magnetometers towed behind a survey vessel in four locations in the San Francisco estuary along profiles crossing the cable path. We applied basic formulas to describe magnetic field from a DC cable summed vectorially with the background geomagnetic field (in the absence of other sources that would perturb the ambient field) to derive characteristics of the cable not immediately or otherwise observable. The magnetic field profiles of 76 survey lines were regressed against the measured fields, representing eight days of measurement. Many profiles were dominated by field distortions caused by bridge structures or other submerged objects, and the cable contribution to the field was not detectable. The regressions based on fundamental principles (Biot Savart law) and the vectorial summation of cable and geomagnetic fields provide estimates of cable characteristics consistent with plausible expectations. For the second objective, detailed gradiometer survey were examined. Distortions in the earth’s main field produced by bridges across the estuary were much greater than those from the TBC. The former anomalies exceeded the latter by an order of magnitude or more. Significant numbers of tagged Chinook salmon smolts migrated past bridges, which produced strong magnetic anomalies, to the Golden Gate Bridge, where they were recorded by dual arrays of acoustic tag-detecting monitors moored in lines across the mouth of the bay. Adult green sturgeon successfully swam upstream and downstream through the estuary on the way to and from their spawning grounds. Hence, the large anomalies produced by the bridges that run perpendicular to these migration routes do not appear to present a strong barrier to the natural seasonal movement patterns of salmonid smolts and adult green sturgeon. Finally, to assess the behavioral responses by migratory Chinook salmon and green sturgeon to a high- voltage power cable - the potential impacts effect of the TBC on fishes migrating through the San Francisco Estuary were examined. These included late-fall run Chinook salmon smolts (Oncorhynchus tshawytscha) that migrate downstream through the San Francisco Estuary to the Pacific Ocean and adult green sturgeon (Acipenser medirostris), which migrate upstream from the ocean through the estuary to their spawning habitat in the upper Sacramento River and return to the ocean after spawning occurs. Our results indicate Chinook salmon smolts may be attracted to the cable after activation (more cable location crossings, more detections at Bay Bridge, high importance of distance to cable in predicting fish location), but are not impeded from successfully migrating through the San Francisco Bay (similar proportions of successful exits, faster transit rates). Cable activity had opposite effects on outbound and inbound green sturgeon migrations: outbound migrations had significantly longer transit times while inbound migrations had significantly shorter migration times. However, the proportion of green sturgeon that successfully migrated through the San Francisco Bay was not strongly impacted after cable activation for either migration type. Based on the work, we provide the following conclusions: 1) calculations of magnetic fields for assessment of marine life can be performed; however, local anomalies in the fields resulting from submerged structures require validation of such calculations through collection of ambient DC magnetic field data, 2) the large anomalies produced by the bridges that run perpendicular to these migration routes do not appear to present a strong barrier to the natural seasonal movement patterns of salmonid smolts and adult green sturgeon and 3) Chinook salmon smolts may be attracted to the activated cable based on analysis of cable crossing, misdirections, and first presence at the array data, however, the cable activation does not appear to change the proportion of smolts that successfully migrate through the San Francisco Bay. Cable activation impacts inbound and outbound migrating adult green sturgeon: travel time was increased for outbound migrations but decreased for inbound migrations. However, cable activation did not appear to impact the success of either migration type in this species.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Seismic Source Modeling Software Enhancements (FY21)

Seismic source modeling allows researchers both to simulate how a source that induces seismic waves interacts with the Earth to produce observed seismograms and, inversely, to infer what the time histories, sizes, and force distributions were for a seismic source given observed seismograms. In this report, we discuss improvements made in FY21 to our software as applies to both the forward and inverse seismic source modeling problems. For the forward portion of the problem, we have added the ability to use full 3-D nonlinear simulations by implementing 3-D time varying boundary conditions within Sandia’s linear seismic code Parelasti. Secondly, on the inverse source modeling side, we have developed software that allows us to invert seismic gradiometer-derived observations in conjunction with standard translational motion seismic data to infer properties of the source that may improve characterization in certain circumstances. First, we describe the basic theory behind each software enhancement and then demonstrate the software in action with some simple examples.

58 GEOSCIENCES↗

NETL Plastic Pipes Project (Final Report)

Plastic or composite pipelines have been the bane of the utility locating industry because they are neither conductive nor magnetic which are the properties traditionally used to locate buried utilities. Ground penetrating radar (GPR) is an effective geophysical tool for locating plastic/composite pipelines where resistive cover allows for adequate penetration of radar energy. However, GPR has limited applicability in areas where the soil cover is conductive due to significant clay and/or salt content. This study examines complementary near-surface geophysical methods that are potentially useful for locating buried plastic/composite pipelines, either singly or in combination. Specifically, this modeling study used computational numerical methods to forward model the response of GPR, resistivity, seismic, gravity gradiometry, and photoacoustic/thermoacoustic imaging methods to plastic/composite pipelines for various scenarios including: (1) pipe diameters ranging between 2 in. to 12 in.; (2) burial depths ranging between 3 ft. to 4 ft.; (3) various degrees in contrast in physical properties (i.e., electrical permittivity, elasticity, resistivity, density); and (4) various experimental acquisition choices (e.g., GPR radar and seismic source frequencies, electrode spacing). Numerical modeling performed herein reconfirmed that GPR is the preferred method for detecting/locating plastic pipelines. A caveat for GPR detection is that the material covering the plastic pipe (trench fill material and adjacent soil) must be sufficiently resistive to allow the two-way propagation to the required depth of investigation and back to the surface. GPR was the only method modeled in this study that can be used to directly detect plastic pipelines of 2-in.-diameter and larger when buried 3-ft-deep. GPR data processing and imaging also can determine pipe depth, pipe diameter, trench dimensions, and moisture conditions. Seismic modeling results suggest that direct detection of a 12-in.-diameter plastic pipe at 3-ft.-depth may be possible under favorable conditions; however, the associated signature would be weak (e.g., surface- to S-wave, backscattered surface-waves, and/or forward scattered surface-waves to S-wave). Direct pipe detection under field conditions with noise and strong lateral geologic heterogeneity is doubtful. Numerical modeling also suggests that plastic pipelines can be indirectly located by detecting the trench in which they are buried. GPR, direct current (DC) resistivity, and seismic methods have the potential to locate the pipeline trench if there is sufficient contrast between the trench-wall and trench-fill materials for the physical property being measured by each method (i.e., electrical permittivity for GPR; resistivity for DC resistivity; or density, compressional velocity, or shear velocity for seismic). Modeling also indicated that currently available (commercial) gravity gradiometers would be unable to directly detect/locate plastic pipelines ≤ 8-in.-diameter when buried 3-ft.-deep given the typical instrument noise floor for field surveying as well as the expected density variations due to geologic heterogeneity. The numerical modeling performed in this project did not identify a universal geophysical technology that can locate buried plastic pipelines in all parts of the United States (although GPR is suggested for all areas with resistive cover). However, the project results suggest that a towed land streamer simultaneously acquiring multiple geophysical data types including multi-offset GPR, multi-channel DC resistivity, seismic geophone- and/or distributed acoustic sensing (DAS), and potentially photoacoustic/thermoacoustic data would be an appropriate platform for locating buried plastic pipeline. Moreover, the complementary multiphysics data acquired by a towed land streamer would permit the use of joint and/or cooperative inversion frameworks for a more rigorous and consistent data interpretation.

42 ENGINEERING↗

Designing a User Interface for Real-Time Magnetometer Data Acquisition

The Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) is a next-generation quantum sensor designed to search for ultralight dark matter and explore new frontiers in quantum mechanics. Due to the experiment s sensitivity to magnetic interference, a magnetometer trolley system was developed to scan magnetic fields along a vacuum tube. Interacting with the system required command-line inputs, creating usability challenges. To improve accessibility and streamline data acquisition, I developed a graphical user interface (GUI) using Python and the customtkinter library. The GUI supports real-time data display, state/mode switching, command execution, and CSV file management. I collaborated with another intern to integrate data visualization features into the GUI, allowing users to generate 3D plots of post-acquisition magnetic field data. In the future, I aim to fix the real-time plotting feature as it results in an unresponsive GUI.

Mendez, Milagros [DuPage Coll.]↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗