Scaling of energy absorbing composite plates

The energy absorption response and crushing characteristics of geometrically scaled graphite-Kevlar epoxy composite plates were investigated. Two different trigger mechanisms including notch, and steeple geometries were incorporated into the plate specimens to initiate crushing. Sustained crushing was achieved with a new test fixture which provided lateral support to prevent global buckling. Values of specific sustained crushing stress (SSCS) were obtained which were lower than values reported for tube specimens from previously published data. Two sizes of hybrid plates were fabricated; a baseline or model plate, and a full-scale plate with inplane dimensions scaled by a factor of two. The thickness dimension of the full-scale plates was increased using two different techniques: the ply-level method in which each ply orientation in the baseline laminate stacking sequence is doubled, and the sublaminate technique in which the baseline laminate stacking sequence is repeated as a group. Results indicated that the SSCS has a small dependence on trigger mechanism geometry. However, a reduction in the SSCS of 10-25% was observed for the full-scale plates as compared with the baseline specimens, indicating a scaling effect in the crushing response.

Jackson, Karen↗

Mechanical Behaviour of Woven Graphite/Polyimide Composites with Medium and High Modulus Graphite Fibers Subjected to Biaxial Shear Dominated Loads

A major limitation of woven fiber/polymer matrix composite systems is the inability of these materials to resist intralaminar and interlaminar damage initiation and propagation under shear-dominated biaxial loading conditions. There are numerous shear test methods for woven fabric composites, each with its own advantages and disadvantages. Two techniques, which show much potential, are the Iosipescu shear and +/- 45 deg tensile tests. In this paper, the application of these two tests for the room and high temperature failure analyses of woven graphite/polyimide composites is briefly evaluated. In particular, visco-elastic micro, meso, and macro-stress distributions in a woven eight harness satin (8HS) T650/PMR-15 composite subjected to these two tests are presented and their effect on the failure process of the composite is evaluated. Subsequently, the application of the Iosipescu tests to the failure analysis of woven composites with medium (T650) and high (M40J and M60J) modulus graphite fibers and PMR-15 and PMR-II-50 polyimide resins is discussed. The composites were tested as-supplied and after thermal conditioning. The effect of temperature and thermal conditioning on the initiation of intralaminar damage and the shear strength of the composites was established.

Kumose, M.↗

Scaling of energy absorbing composite plates

The energy absorption response and crushing characteristics of geometrically scaled graphite-Kevlar epoxy composite plates were investigated. Three different trigger mechanisms including chamfer, notch, and steeple geometries were incorporated into the plate specimens to initiate crushing. Sustained crushing was achieved with a simple test fixture which provided lateral support to prevent global buckling. Values of specific sustained crushing stress (SSCS) were obtained which were comparable to values reported for tube specimens from previously published data. Two sizes of hybrid plates were fabricated; a baseline or model plate, and a full-scale plate with in-plane dimensions scaled by a factor of two. The thickness dimension of the full-scale plates was increased using two different techniques; the ply-level method in which each ply orientation in the baseline laminate stacking sequence is doubled, and the sublaminate technique in which the baseline laminate stacking sequence is repeated as a group. Results indicated that the SSCS is independent of trigger mechanism geometry. However, a reduction in the SSCS of 10-25 percent was observed for the full-scale plates as compared with the baseline specimens, indicating a scaling effect in the crushing response.

Jackson, Karen↗

Evaluation of the Structural Response and Failure of a Full-Scale Stitched Graphite-Epoxy Wing

Analytical and experimental results for an all-composite full-scale wing box are presented. The wing box is representative of a section of a 220-passenger commercial transport aircraft wing box and was designed and constructed by The Boeing Company as part of the NASA Advanced Subsonics Technology (AST) program. The semi-span wing was fabricated from a graphite-epoxy material system with cover panels and spars held together using Kevlar stitches through the thickness. No mechanical fasteners were used to hold the stiffeners to the skin of the cover panels. Tests were conducted with and without low-speed impact damage, discrete source damage and repairs. Upbending, down-bending and brake roll loading conditions were applied. The structure with nonvisible impact damage carried 97% of Design Ultimate Load prior to failure through a lower cover panel access hole. Finite element and experimental results agree for the global response of the structure.

Jegley, Dawn C.↗

Development of a Continuum Damage Mechanics Material Model of a Graphite-Kevlar(Registered Trademark) Hybrid Fabric for Simulating the Impact Response of Energy Absorbing Kevlar(Registered Trademark) Hybrid Fabric for Simulating the Impact Response of Energy Absorbing

This paper describes the development of input properties for a continuum damage mechanics based material model, Mat 58, within LS-DYNA(Registered Trademark) to simulate the response of a graphite-Kevlar(Registered Trademark) hybrid plain weave fabric. A limited set of material characterization tests were performed on the hybrid graphite-Kevlar(Registered Trademark) fabric. Simple finite element models were executed in LS-DYNA(Registered Trademark) to simulate the material characterization tests and to verify the Mat 58 material model. Once verified, the Mat 58 model was used in finite element models of two composite energy absorbers: a conical-shaped design, designated the "conusoid," fabricated of four layers of hybrid graphite-Kevlar(Registered Trademark) fabric; and, a sinusoidal-shaped foam sandwich design, designated the "sinusoid," fabricated of the same hybrid fabric face sheets with a foam core. Dynamic crush tests were performed on components of the two energy absorbers, which were designed to limit average vertical accelerations to 25- to 40-g, to minimize peak crush loads, and to generate relatively long crush stroke values under dynamic loading conditions. Finite element models of the two energy absorbers utilized the Mat 58 model that had been verified through material characterization testing. Excellent predictions of the dynamic crushing response were obtained.

Jackson, Karen E.↗

Interlaminar shear properties of graphite fiber, high-performance resin composites

Short beam testing was used to determine the shear properties of laminates consisting of T-300 and Celion 3000 and 6000 graphite fibers, in epoxy, hot melt and solvent bismaleimide, polyimide and polystyrylpyridine (PSP). Epoxy, composites showed the highest interlaminar shear strength, with values for all other resins being substantially lower. The dependence of interlaminar shear properties on the fiber-resin interfacial bond and on resin wetting characteristics and mechanical properties is investigated, and it is determined that the lower shear strength of the tested composites, by comparison with epoxy resin matrix composites, is due to their correspondingly lower interfacial bond strengths. An investigation of the effect of the wettability of carbon fiber tow on shear strength shows wetting variations among resins that are too small to account for the large shear strength property differences observed.

Needles, H. L.↗

Utilization of Carbon Supply Chain Wastes and Byproducts to Manufacture Graphite for Energy Storage Applications

This project explored how coal and waste coal can be transformed into high-value graphite used in batteries for electric vehicles and power grids. A manufacturing technique that converts coal into carbon foam and subsequently graphite was developed and refined to improve the thermal and mechanical properties of the resulting materials. Cost-effectiveness and environmental impacts were also evaluated. Coal-derived graphite, especially when processed at high temperatures, was shown to perform comparably to commercial graphite in battery tests. Advanced computer simulations were used to model battery behavior and predict long-term performance, demonstrating that coal-based graphite has the potential to support electric vehicle deployment while reducing reliance on imported materials. This work offers a promising pathway for cleaner energy storage solutions and creates economic opportunities for coal-reliant communities by generating new uses for mining byproducts.

01 COAL, LIGNITE, AND PEAT↗

Mechanical property degradation of graphite/polyimide composites after exposure to moisture or shuttle orbiter fluids

The effects of moisture exposure on the mechanical properties of graphite polyimide systems are presented. The mechanism of the degradation and the magnitude of the affect associated with specific mechanical properties is investigated. An experimental effort involving exposure to selected environmental variables and subsequent mechanical property testing and analysis is included.

Lisagor, W. B.↗

Statistical distribution of mechanical properties for three graphite-epoxy material systems

Graphite-epoxy composites are playing an increasing role as viable alternative materials in structural applications necessitating thorough investigation into the predictability and reproducibility of their material strength properties. This investigation was concerned with tension, compression, and short beam shear coupon testing of large samples from three different material suppliers to determine their statistical strength behavior. Statistical results indicate that a two Parameter Weibull distribution model provides better overall characterization of material behavior for the graphite-epoxy systems tested than does the standard Normal distribution model that is employed for most design work. While either a Weibull or Normal distribution model provides adequate predictions for average strength values, the Weibull model provides better characterization in the lower tail region where the predictions are of maximum design interest. The two sets of the same material were found to have essentially the same material properties, and indicate that repeatability can be achieved.

Reese, C.↗

Effects of high energy radiation on the mechanical properties of epoxy-graphite fiber reinforced composites

The effects of high energy radiation on the mechanical properties and on the molecular and structural properties of graphite fiber reinforced composites were assessed so that the durability of such composites in space applications could be predicted. Investigative techniques including ESR and infrared spectroscopy, ESCA, contact angle measurements, and dynamic and static mechanical testing (3-point bending and interlaminar shear) were employed. The results using these different techniques are individually described, and the implications of the data are discussed. The proposed plan of work for the next fiscal year is outlined.

Fornes, R. E.↗

Modeling and Testing of the Viscoelastic Properties of a Graphite Nanoplatelet/Epoxy Composite

In order to facilitate the interpretation of experimental data, a micromechanical modeling procedure is developed to predict the viscoelastic properties of a graphite nanoplatelet/epoxy composite as a function of volume fraction and nanoplatelet diameter. The predicted storage and loss moduli for the composite are compared to measured values from the same material using three test methods; Dynamical Mechanical Analysis, nanoindentation, and quasi-static tensile tests. In most cases, the model and experiments indicate that for increasing volume fractions of nanoplatelets, both the storage and loss moduli increase. Also, the results indicate that for nanoplatelet sizes above 15 microns, nanoindentation is capable of measuring properties of individual constituents of a composite system. Comparison of the predicted values to the measured data helps illustrate the relative similarities and differences between the bulk and local measurement techniques.

Odegard, Gregory M.↗

Analytical models of hydrogen transport in graphite

The importance of graphite-hydrogen chemical reactions to fusion, fission, and hydrogen storage applications, combined with the rapidly evolving knowledge on the underlying mechanisms, has led to the development of multiple models to describe hydrogen transport in graphite. Significant differences exist among these models, resulting from discrepancies in the modeling assumptions, intended degree of fidelity, and conditions of applicability. This paper attempts at reconciling these apparent differences by providing a comprehensive description of the constitutive equations governing hydrogen transport in graphite at high-temperature, identifying outstanding gaps in knowledge, illustrating how these different models approach them, and proposing alternative analytical formulations grounded on experimental results from hydrogen-graphite studies. Governing equations, closing relations, and simplifying assumptions are discussed for hydrogen transport at the inter-granular and intra-granular level, accompanied by compiled experimental data and illustrated energy diagrams associated to the proposed transport mechanisms. Analytical formulations are provided to reproduce competing hypotheses on the mechanisms, supporting the development of a range of computational models that can enable resolution of outstanding knowledge gaps through comparative testing against experimental data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of long-duration exposure to the natural space environment on graphite-polyimide and graphite-epoxy mechanical properties

Experiment AO175 involved passive exposure (on oblique leading and trailing faces of LDEF) of carbon-fiber reinforced laminates of epoxy, bismaleimide, and polyimide resins. Post-flight evaluation included: optical examination of exposed surfaces, panel weight and distortion measurements, ultrasonic c-scan inspection, and conventional mechanical testing of coupons machined from the panel.

Vyhnal, Richard F.↗

Vapor/Mist Used to Lubricate Gears After Loss of Primary Lubrication System

Loss of lubrication in rotorcraft drive systems is a demanding requirement placed on drive system manufacturers. The drive system must operate for at least 30 minutes once the primary lubrication system has failed. This test is a military requirement that must be passed prior to certification of the aircraft. As new aircraft engines, operating at higher speeds, are fielded, the requirements for the drive system become increasingly more difficult. Also, the drive system must be lightweight, which minimizes the opportunity to use the gear bodies to absorb the tremendous amount of heating that takes place. In many cases, the amount of heat generated because of the high speed and load requires an emergency lubrication system that negatively impacts the aircraft's weight, complexity, and cost. A single mesh spur gear test rig is being used at the NASA Glenn Research Center to investigate possible emergency lubrication system improvements that will minimize the impact of having these systems onboard rotorcraft. A technique currently being investigated uses a vapor/mist system to lubricate the contacting surfaces after the primary lubrication system has been shut down. A number of tests were conducted in which the vapor/mist used the same lubricant as the primary system, but at a greatly reduced flow rate. Each test was initiated with the primary lubrication system operational and at steady-state conditions for a given speed and load. Then the primary lubrication system was shut down, and the vapor/mist lubrication system was initiated. An example of the tests conducted is shown in the figures. These preliminary tests have uncovered a mechanism that provides a lubricious, carbonaceous solid on the surface that actually reduces the surface temperature of the meshing gear teeth during operation. Surface analysis of the carbonaceous solid revealed it was graphitic. This mechanism is the synthetic lubricant "coking" on the active profile of the gears, which reduces the friction between the contacting gear surfaces. The level of load affects the onset of this mechanism: the higher the load, the sooner coking takes place. Future work will investigate several other factors that could improve the already promising results that have been attained.

Handschuh, Robert F.↗

HDG-1 Experiment Irradiation Monitoring Data Qualification Final Report

SUMMARY The U.S. Department of Energy (DOE) Advanced Reactor Technologies (ART) Graphite Research and Development (GRD) Program is conducting a series of six experiments to quantify the effects of irradiation on nuclear-grade graphite. This report documents the qualification of irradiation monitoring data for the fifth experiment, High Dose Graphite-1 (HDG-1). Qualified monitoring data are required by the ART program to support the design and licensing of the first high-temperature reactor (HTR) nuclear plant. Data are classified as Qualified if they meet the usage requirements described in the experiment planning and quality assurance (QA) documents, Failed if they do not meet those requirements and provide no usable information, or Trend if they do not fully meet all requirements but still provide useful information subject to an assessment of how any deficiencies may affect a particular use of the data. HDG-1 irradiation began with Advanced Test Reactor (ATR) Cycle 168B on August 24, 2020, and concluded after Cycle 173C on January 27, 2025. The HDG-1 capsule was removed from the reactor core twice—during core internal change (CIC) Cycle 170A and powered axial locator mechanism (PALM) Cycle 172A—to prevent overheating of the graphite specimens during high-power PALM cycles. The capsule was therefore irradiated during a total of seven normal ATR cycles: 168B, 169A, 171A, 171B, 173A, 173B, and 173C. Irradiation monitoring data evaluated in this report include thermocouple (TC) temperature, gas flow rate, gas moisture, gas pressure, specimen load, and graphite stack displacement. Temperature. A total of 14,508,065 TC temperature records were captured. Of these, 13,901,785 (95.8%) are Qualified and 606,280 (4.2%) are Failed. The principal source of failed temperature data was the instrument failure of TC-9 (Zone 2) on June 24, 2024, and TC-10 (Zone 1) on July 5, 2024, near the end of Cycle 173A, which resulted in 595,554 Failed readings. An additional 379 missing values and 10,347 slightly negative values from TC-13 during ATR outages are also Failed. Neither TC-9 nor TC-10 was used as a temperature-control TC, and their failures did not compromise capsule condition monitoring. Correlation analysis of all 13 TCs found no evidence of virtual junction formation. Control chart analysis revealed clear downward drift of approximately 80°C for TC-6 (Zone 3) relative to other stable TCs, and possible downward drift of approximately 60°C for TC-13 relative to the Zone 5 control TC (TC-1), though TC-13 remained consistent with the Zone 2 control TC (TC-12). Gas flow. A total of 20,088,090 gas flow rate records were captured. Of these, 19,941,463 (99.3%) are Qualified and 146,627 (0.7%) are Failed due to missing values. All argon, helium, and total gas flow data were within expected ranges throughout the irradiation. Gas moisture. A total of 1,116,005 outlet gas moisture values were captured. Of these, 1,101,421 (98.7%) are Qualified and 14,584 (1.3%) are Failed, comprising 14,556 out-of-range values and 28 missing values. The out-of-range moisture values exceeded 22,000 ppmv for approximately 1 week at the beginning of Cycle 173A, when accumulated moisture evaporated after the capsule was retrieved from water storage during PALM Cycle 172A and reinserted into the east flux trap. Moisture levels returned to below 25 ppmv for the remaining three cycles, and the transient high-moisture event did not affect the integrity of specimen irradiation. Gas pressure. A total of 7,812,035 gas pressure values were captured. Of these, 6,642,048 (85.0%) are Qualified and 1,169,987 (15.0%) outlet pressure values are Failed, comprising 718,537 zero outlet pressure values due to sensor failure from Cycle 168B through Cycle 171B, 54,550 missing values, and 396,900 too-low outlet pressure values, ranging from 1.1 to 1.6 psia after sensor replacement during Cycle 173A. Load. A total of 6,696,030 load values were captured. Of these, 6,694,580 (99.98%) are Qualified and 1,450 (0.02%) are Failed due to missing values. Applied loads to the six specimen stacks were stable throughout the irradiation. Stack displacement. A total of 6,696,030 displacement values were captured. Of these, 5,713,297 (85.32%) are Qualified and 3,781 (0.06%) are Failed due to missing values. Stack displacement increased consistently throughout the irradiation, reaching approximately 3.08 in. for Channels 5 and 6 by the end of irradiation. 978,952 (14.62%) substantially elevated displacements observed for Channel 6 beginning in Cycle 171A and for Channel 5 beginning in Cycle 173A are assigned Trend status. Raising pressure. A total of 1,115,999 raising pressure values were captured. Of these, 1,115,430 (99.95%) are Qualified and 569 (0.05%) are Failed due to missing values. Ram pressure. A total of 6,696,030 ram pressure values were captured. Of these, 6,692,249 (99.95%) are Qualified and 3,484 (0.05%) are Failed due to missing values. Stack raising was perf

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of Constituent Properties on Compression Failure Mechanisms

Compression failure mechanisms were investigated through the analysis of matrix-embedded fiber bundles. The use of fiber bundle specimens can provide much needed information on compression failure mechanisms because failure of the bundle is well contained and can be monitored during testing. The method can clearly distinguish between buckling-induced failure and shear-induced failure. The results indicate that WY and T300 graphite fibers and E-glass fiber fail in buckling while the high-modulus P75S graphite fiber fails in shear. Buckling-induced failure becomes more evident with low-modulus fiber in softer epoxy.

Hahn, H. T.↗

Response of polymer composites to high and low velocity impact

The present investigation of fiber-reinforced polymer matrix composites' impact characteristics employed a drop tower for the low-velocity impact case and a novel, projectile instantaneous velocity-measuring sensor for high-velocity impact. Attention was given to the energy loss of projectiles in composites reinforced with polyethylene, kevlar, and graphite. Two distinct energy-loss mechanisms are noted, the first of which is due to the actual fracture process while the other is due to the generation of friction heat. The drop-tower impact-test results furnish the strain-rate dependence of the energy loss.

Hsieh, C. Y.↗

Modeling and Characterization of a Graphite Nanoplatelet/Epoxy Composite

A micromechanical modeling procedure is developed to predict the viscoelastic properties of a graphite nanoplatelet/epoxy composite as a function of volume fraction and nanoplatelet diameter. The predicted storage and loss moduli from the model are compared to measured values from the same material using Dynamical Mechanical Analysis, nanoindentation, and tensile tests. In most cases, the model and experiments indicate that for increasing volume fractions of nanoplatelets, both the storage and loss moduli increase. Also, in most cases, the model and experiments indicate that as the nanoplatelet diameter is increased, the storage and loss moduli decrease and increase, respectively.

Odegard, Gregory M.↗