Search NASA⌕ Search

SEARCH · Search NASA

Results for “grating array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

First Results from the Thomson Scattering Diagnostic on the Large Plasma Device

We present the first Thomson scattering measurements of electron density and temperature in the Large Plasma Device (LAPD), a 22 m long magnetized linear plasma device at the University of California Los Angeles (UCLA). The diagnostic spectrally resolves the Doppler shift imparted on light from a frequency-doubled Nd:YAG laser when scattered by plasma electrons. A fiber array coupled to a triple-grating spectrometer is used to obtain high stray light rejection and discriminate the faint scattering signal from a much larger background. In the center of the plasma column, the measured electron density and temperature are about ne≈1.5×1013 cm−3 and Te≈ 3 eV, respectively, depending on the discharge parameters and in good agreement with Langmuir probe data. Optical design considerations to maximize photon count while minimizing alignment sensitivity are discussed in detail and compared to numerical calculations. Raman scattering off of a quartz crystal probe is used for an absolute irradiance calibration of the system.

Kaloyan, Marietta (ORCID:0000000182593038)↗

Measuring Monodisperse Small Particles En Masse

New optical method enables determination of sizes of approximately-micron-sized particles. Arrays of particles act as diffraction gratings. Simple and inexpensive apparatus replaces high-magnification microscopes in measurements of diameters of small polystyrene latex spheres. Device being used to determine monodispersity and diameters of polystyrene latex microspheres used as seeding material for laser-velocimetry flow measurements in NASA's wind tunnels. Characterization of particle sizes important in wide range of fields, including manufacture of plastics and ceramics, biochemistry, and medicine.

Bruce, Robert A.↗

Studies of thermal wave phenomena on the Jovian planets

Ground based and Voyager observations of Jupiter have provided evidence that the tropospheric temperature shows global scale longitudinal variations which are often wavelike in character. Voyager data are reported to exhibit the presence of slowly moving thermal features, wherein the jovian tropospheric temperature patterns are not advected by the equatorial zonal winds, but are not found to rotate at the System III (interior) rate. Ground based data in a broad infrared band (8 to 13 micron) show a wavelike structure whose amplitude and spatial scale are similar to the reported properties of the slowly moving thermal features. This study is directed toward obtaining additional ground based data in infrared spectral bands whose contribution functions are optimized for specific atmospheric regions (tropospheric at 20 micron, and stratospheric at 7.8 micron), in order to confirm the previous results, and to identify the nature and physical significance of wavelike longitudinal temperature fluctuations on the Jovian planets. A 2-D infrared array detector and low resolution cryogenic grating spectrometer is being adapted to obtain maps in approx. 2/cm bandpasses.

Deming, Drake↗

Lessons Learned from the AIRS Pre-Flight Radiometric Calibration

The Atmospheric Infrared Sounder (AIRS) instrument flies on the NASA Aqua satellite and measures the upwelling hyperspectral earth radiance in the spectral range of 3.7-15.4 micron with a nominal ground resolution at nadir of 13.5 km. The AIRS spectra are achieved using a temperature controlled grating spectrometer and HgCdTe infrared linear arrays providing 2378 channels with a nominal spectral resolution of approximately 1200. The AIRS pre-flight tests that impact the radiometric calibration include a full system radiometric response (linearity), polarization response, and response vs scan angle (RVS). We re-derive the AIRS instrument radiometric calibration coefficients from the pre-flight polarization measurements, the response vs scan (RVS) angle tests as well as the linearity tests, and a recent lunar roll test that allowed the AIRS to view the moon. The data and method for deriving the coefficients is discussed in detail and the resulting values compared amongst the different tests. Finally, we examine the residual errors in the reconstruction of the external calibrator blackbody radiances and the efficacy of a new radiometric uncertainty model. Results show the radiometric calibration of AIRS to be excellent and the radiometric uncertainty model does a reasonable job of characterizing the errors.

Sounder↗

The Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument which will survey galaxy and star formation history over cosmological time scales. Rather than identifying individual objects, EXCLAIM will be a pathfinder to demonstrate an intensity mapping approach, which measures the cumulative redshifted line emission. EXCLAIM will operate at 420-540 GHz with a spectral resolution R=512 to measure the integrated CO and [CII] in redshift windows spanning \exclaimz. CO and [CII] line emissions are key tracers of the gas phases in the interstellar medium involved in star-formation processes. EXCLAIM will shed light on questions such as why the star formation rate declines at z < 2, despite continued clustering of the dark matter. The instrument will employ an array of six superconducting integrated grating-analog spectrometers (µ-Spec) coupled to microwave kinetic inductance detectors (MKIDs). Here we present an overview of the EXCLAIM instrument design and status.

Instrumentation and Photography↗

EXCLAIM: A New Balloon Mission to Map the Cosmological History of Galaxies

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument that will survey galaxy and star formation history over cosmological time scales. Rather than identifying individual objects, EXCLAIM will be a pathfinder to demonstrate an intensity mapping approach, which measures the cumulative redshifted line emission. EXCLAIM will operate at 420-540 GHz with a spectral resolution R=512 to measure the integrated CO and [CII] in redshift windows spanning 0 < z < 3.5. CO and [CII] line emissions are key tracers of the gas phases in the interstellar medium involved in star-formation processes. EXCLAIM will shed light on questions such as why the star formation rate declines at z < 2, despite continued clustering of the dark matter. The instrument will employ an array of six superconducting integrated grating-analog spectrometers (micro-spec) coupled to microwave kinetic inductance detectors (MKIDs). I will present an overview of the EXCLAIM instrument design and status.

Eric Switzer↗

The Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a high-altitude balloon telescope designed to deepen our understanding of star formation in a cosmological context, shedding light on why the star formation rate declines and breaks away from the cosmological evolution of dark matter for redshifts z>2 [1]. EXCLAIM will operate at 420–540 GHz with a spectral resolution of R=512 to measure the integrated line emission from galaxies and the intergalactic medium (IGM), in particular CO and [CII] line emissions from the nearby universe out to redshifts of z~3.5. This approach is known as Intensity Mapping (IM), which provides efficient access to large cosmological volumes and redshifts with sensitivity limited by detector noise or photon background, while requiring modest apertures. The instrument will employ an array of six superconducting integrated grating-analog spectrometers (µ-Spec) with superconducting microwave kinetic inductance detectors (KIDs) in an all-cryogenic telescope (1.7 K) to achieve near background-limited sensitivity. Here, we present an overview of the EXCLAIM instrument and status, with emphasis on the Attitude Determination & Control System (ADCS) and the thermal system.

Giuseppe Cataldo↗

Three-dimensional modeling of electric-field enhancement in multilayer dielectric gratings arising from inadvertent flaws

Pulse-compression gratings for high-power, short-pulse laser systems are exposed to high electric fields that are further enhanced locally due to their 2D nanostructured surface. This makes them vulnerable to laser-induced damage. The present work considers the effect on electric-field modulation caused by an array of commonly found inadvertent flaws in gratings including fabrication defects, contamination particles, and laser-induced–damage initiation. These defects affect the laser-damage performance characteristics of the grating. To understand the local field-enhancement distribution due these imperfections, 3D modeling of the electric-field distribution is performed with a sufficiently high resolution of 1/74 of the laser wavelength ( λ ) while considering a volume of ≈489 λ 3 . The results provide estimates for the ensuing electric-field intensification and projected reduction of the laser-damage thresholds, as well as the anticipated pattern of damage growth initiation.

47 OTHER INSTRUMENTATION↗

Arrayed Micro-Ring Spectrometer System and Method of Use

A spectrometer system includes an array of micro-zone plates (MZP) each having coaxially-aligned ring gratings, a sample plate for supporting and illuminating a sample, and an array of photon detectors for measuring a spectral characteristic of the predetermined wavelength. The sample plate emits an evanescent wave in response to incident light, which excites molecules of the sample to thereby cause an emission of secondary photons. A method of detecting the intensity of a selected wavelength of incident light includes directing the incident light onto an array of MZP, diffracting a selected wavelength of the incident light onto a target focal point using the array of MZP, and detecting the intensity of the selected portion using an array of photon detectors. An electro-optic layer positioned adjacent to the array of MZP may be excited via an applied voltage to select the wavelength of the incident light.

Choi, Sang H.↗

Resolving Wave-Particle Duality Could Accelerate the Mass Production of Quantum Computers

Quantum computers, hypothesized in 1980s, use concepts of superposition and entanglement phenomena. Although theoretical propositions and associated search algorithms for accurate measurements are being generated, the development of practical quantum computers themselves are advancing very slowly requiring enormous time and investments. The underlying concepts of a quantum computer are not new to the optical domain. However, the crucial enabling concepts of Entanglement and Superposition Principle are remaining clouded under the unresolved postulates, Wave-Particle Duality (WPD), and Wave Packet Reduction (WPR), implicating incompleteness in the interpretations of the mathematical formalism behind Quantum Mechanics. The WPD debate started during late1600 between Newton and Huygens. Young’s resolution of WPD through his double-slit experiment in 1802 was effectively overturned by Einstein’s interpretation of photoelectric effect as due to “indivisible light quanta”. However, Einstein disowned his “light quanta” postulate shortly before his death in1955, even though it had earned him the Nobel Prize. We resolve WPD by synthesizing Newton’s and Maxwell’s concepts and assume atoms do emit quanta but propagate as time-finite exponential pulses. This assumption also resolves WPR for light-matter interaction with the assumption that Schrodinger’s ψ represents atom’s internal dipolar amplitude stimulations. This over-turns Born’s interpretation that ψ only represents the abstract mathematical probability amplitude, rather than the physical “internal amplitude stimulation” of the quantum entity. However, our concept of atomic pulse emission forces us to re-derive the expression for the N-slit grating-spectrometer response since the classical derivation uses CW light, which does not exist. This pulsespectrometric response function strengthens our postulate since the grating response to the exponential pulse appears to be the convolution of a Lorentzian spectrum with the classical CW response function of the grating. The Fourier Transform of an exponential function is Lorentzian and QM predicts spontaneous emission line width to be Lorentzian. Then, conceptually one can extend the grating-expression (with N=2) to get the double-slit pattern. This approach preserves the classical causality that each of the two slits, like the N-signals out of a grating, are physically real and jointly stimulate the quantum detector array at the far field to generate the “Local” cosine fringes. The detector array executes the square modulus operation on its imposed dipolar amplitude stimulation and absorbs the necessary energy to fill up their quantum cups. Hence the double-slit pattern must also be “Local”, just as the N-slit grating spectrum is generated locally at the exit spectral-plane of the spectrometer. This removes the need to believe that “single photons” mysteriously generate the double slit pattern. Quantum computers, hypothesized in 1980s, use concepts of superposition and entanglement phenomena. Although theoretical propositions and associated search algorithms for accurate measurements are being generated, the development of practical quantum computers themselves are advancing very slowly requiring enormous time and investments. The underlying concepts of a quantum computer are not new to the optical domain. However, the crucial enabling concepts of Entanglement and Superposition Principle are remaining clouded under the unresolved postulates, Wave-Particle Duality (WPD), and Wave Packet Reduction (WPR), implicating incompleteness in the interpretations of the mathematical formalism behind Quantum Mechanics. The WPD debate started during late1600 between Newton and Huygens. Young’s resolution of WPD through his double-slit experiment in 1802 was effectively overturned by Einstein’s interpretation of photoelectric effect as due to “indivisible light quanta”. However, Einstein disowned his “light quanta” postulate shortly before his death in1955, even though it had earned him the Nobel Prize. We resolve WPD by synthesizing Newton’s and Maxwell’s concepts and assume atoms do emit quanta but propagate as time-finite exponential pulses. This assumption also resolves WPR for light-matter interaction with the assumption that Schrodinger’s ψ represents atom’s internal dipolar amplitude stimulations. This over-turns Born’s interpretation that ψ only represents the abstract mathematical probability amplitude, rather than the physical “internal amplitude stimulation” of the quantum entity. However, our concept of atomic pulse emission forces us to re-derive the expression for the N-slit grating-spectrometer response since the classical derivation uses CW light, which does not exist. This pulsespectrometric response function strengthens our postulate since the grating response to the exponential pulse appears to be the convolution of a Lorentzian spectrum with the classical CW response function of the grating. The Fourier Transform of an exponential function is Lorentzian and QM predicts spontaneous emission line width to be Lorentzian. Then, conceptually one can extend the grating-expression (with N=2) to get the double-slit pattern. This approach preserves the classical causality that each of the two slits, like the N-signals out of a grating, are physically real and jointly stimulate the quantum detector array at the far field to generate the “Local” cosine fringes. The detector array executes the square modulus operation on its imposed dipolar amplitude stimulation and absorbs the necessary energy to fill up their quantum cups. Hence the double-slit pattern must also be “Local”, just as the N-slit grating spectrum is generated locally at the exit spectral-plane of the spectrometer. This removes the need to believe that “single photons” mysteriously generate the double slit pattern.

Quantum Computer↗

A system definition study for the Advanced Meteorological Temperature Sounder (AMTS)

The functional requirements of Exhibit A (11) were used as the baseline for the conceptual design of a fixed grating out of plane multidetector spectrometer for the Space Shuttle application. Because the grating instrument would be large and the 28 element detector array would be difficult to cool radiatively from a free flying spacecraft and because increasing the spectral resolution of the grating instrument would be difficult in an instrument of reasonable size, a parallel study of a Nichelson interferometer spectrometer was undertaken. This type of instrument offers compact size, fewer detectors to cool, and the possibility of increased spectral resolution. The design and performance parameters of both the grating and interferometer approaches are described. The tradeoffs involved in comparing the two systems for sounding applications are discussed.

Source record↗

Order-sorting filter transmittance measured with an array detector

The simultaneous measurement of the spectrally and spatially variant transmittance of a linear variable order-sorting filter in a manner that closely resembles its conditions of actual use is described. The transmittance of a prototype order-sorting filter was measured in the 400- to 880-nm wavelength region by illuminating it with the output beam of a spectrophotometer while the filter was attached to the front of a 30 x 32 pixel silicon array detector. The filter was designed to be used in the output beam of a grating spectrometer to prevent the dispersal of higher diffracted orders onto an array detector. Areas of the filter that were spatially matched to the corresponding detector pixel column had measured peak transmittances of about 90 percent that were uniform to within +/- 1.5 percent along a given column. Transmittances for incident wavelengths shorter than the desired bandpass, corresponding to the order overlap region, were measured in the 0.003 range. Line spread function measurements made with the array detector indicated no significant beam spreading caused by inserting the filter into the beam.

Heaney, James B.↗

Single-lens computed tomography imaging spectrometer and method of capturing spatial and spectral information

Computed tomography imaging spectrometers ("CTISs") employing a single lens are provided. The CTISs may be either transmissive or reflective, and the single lens is either configured to transmit and receive uncollimated light (in transmissive systems), or is configured to reflect and receive uncollimated light (in reflective systems). An exemplary transmissive CTIS includes a focal plane array detector, a single lens configured to transmit and receive uncollimated light, a two-dimensional grating, and a field stop aperture. An exemplary reflective CTIS includes a focal plane array detector, a single mirror configured to reflect and receive uncollimated light, a two-dimensional grating, and a field stop aperture.

Wilson, Daniel W.↗

Scalable low-loss cryogenic packaging of quantum memories in CMOS-foundry processed photonic chips

Optically linked solid-state quantum memories such as color centers in diamond are a promising platform for distributed quantum information processing and networking. Photonic integrated circuits (PICs) have emerged as a crucial enabling technology for these systems, integrating quantum memories with efficient electrical and optical interfaces in a compact and scalable platform. Packaging these hybrid chips into deployable modules while maintaining low optical loss and resiliency to temperature cycling is a central challenge to their practical use. We demonstrate a packaging method for PICs using surface grating couplers and angle-polished fiber arrays that is robust to temperature cycling, offers scalable channel count, applies to a wide variety of PIC platforms and wavelengths, and offers pathways to automated high-throughput packaging. Using this method, we show optically and electrically packaged quantum memory modules integrating all required qubit controls on chip, operating at millikelvin temperatures with <3 dB losses achievable from fiber to quantum memory for the TE 0 mode at a wavelength of 737 nm.

Bernson, Robert [Tyndall National Institute, Cork ↗

Technology thrusts for passive remote sensing. Sensing Technology Panel report

Technology thrusts for broadband spectrometry and gas filter radiometry development are identified. The development of 'smart' processing and cryogenics/cooling systems for all types of broadband spectrometers is advised. The use of large fixed gratings and the development of 1000-element arrays is recommended. Improvements suggested for interferometers are: the mitigation of background fluctuations; the development of multiaperature, multiband interferometers; and provision of in-flight alignment verification. Specifically recommended for gas filter radiometers are the development of gas filter cell technology, of liner and high dynamic range detectors, and of high uniform optical elements.

Source record↗

Spectral mapping of Jupiter and the Galilean satellites in the near infrared

A near-infrared mapping spectrometer is included in the science complement of the Galileo Mission, which will explore Jupiter and its satellites in the mid-1980s. The objectives of the infrared mapping spectrometer experiment are to map compositional units on the surfaces of the Jovian satellites and to characterize the mineral content of these units. For Jupiter's atmosphere, this experiment will investigate such areas as cloud properties and the spatial and temporal variability of minor species. The instrument consists of a telescope, a plane grating spectrometer, a Si and InSb detector array, and a passive radiative cooler. The spectral range is 0.7-5.2 microns, covered with a resolution of 0.025 micron. A wobbling secondary mirror in the telescope provides one dimension of spatial scanning, while the other dimension is provided by motion of the spacecraft scan platform.

Carlson, R. W.↗

Spectral transmissometer and radiometer - Design and initial results

A new solid-state spectral transmissometer and radiometer is described. The radiometer measures upwelling radiance, downwelling irradiance, and beam transmittance from 390 to 750 nm with channel widths of 2.35 nm. The spectrometer consists of a 256 element CCD linear array collecting light dispersed by a reflection grating in a modified Littrow configuration. The spectrometer is time and space-shared among the three signal types. The instrument has been deployed as a free-drifting buoy and in the profiling mode, with data stored internally on a magnetic bubble memory or sent up a conducting cable as desired. Power can be supplied either by a detachable external battery pack or through conducting cable. The instrument has been deployed in the oligotrophic North Pacific Central Gyre and in the eutrophic Straits of Juan de Fuca, and preliminary results for each region are discussed.

Carder, Kendall L.↗

Spectrometer system for diffuse extreme ultraviolet radiation

A unique grazing incidence spectrometer system has been designed to study diffuse line emission between 80 and 650 A with 10-30 A resolution. The minimum detectable emission line strength during a 5-min observation ranges from 100-2000 ph/sq cm sec str. The instrument uses mechanically ruled reflection gratings placed in front of a linear array of mirrors. These mirrors focus the spectral image on microchannel plate detectors located behind thin filters. The field of view is 40 min of arc by 15 deg, and there is no spatial imaging. This instrument has been fabricated, calibrated, and successfully flown on a sounding rocket to observe the astronomical background radiation.

Labov, Simon E.↗