Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A Testing Framework for Grid-Forming Resources

This paper presents a testing framework for grid-forming (GFM) resources. First, it analytically derives in the frequency domain the active and reactive power response of an ideal voltage source with a reactor. These transfer functions are then used to quantify the voltage source behavior expected from a GFM inverter within subtransient timescales (5-15 cycles) following a grid disturbance. The paper also shows that the testing of a GFM inverter might require a reactor of an appropriate size between the inverter and the grid simulator used for the inverter testing. Finally, the paper presents a systematic approach for developing specifications for GFM resources using active and reactive power response frequency scans. The testing framework and results presented in this paper are demonstrated using EMT-PSCAD simulations of a 1-MW GFM inverter.

frequency scans↗

A Testing Framework for Grid-Forming Resources: Preprint

This paper presents a testing framework for grid-forming (GFM) resources. It first analytically derives in frequency domain the active and reactive power response of an ideal voltage source with a reactor. These transfer functions are then used to quantify the voltage source behavior expected from a GFM inverter within subtransient time scales (5-10 cycles) following a grid disturbance. The paper also shows that the testing of a GFM inverter might require a reactor of an appropriate size between the inverter and the grid simulator used for the inverter testing. Finally, the paper presents a systematic approach for developing specifications for GFM resources using active and reactive power response frequency scans. The testing framework and results presented in this paper are demonstrated using EMT simulations of a 1-MW GFM inverter.

frequency scans↗

A multi-center quadrature scheme for the molecular continuum

We report a common way to evaluate electronic integrals for polyatomic molecules is to use Becke’s partitioning scheme (Becke and Chem, 1988) in conjunction with overlapping grids centered at each atomic site. The Becke scheme was designed for integrands that fall off rapidly at large distances, such as those approximating bound electronic states. When applied to states in the electronic continuum, however, Becke scheme exhibits slow convergence and it is highly redundant. Here, we present a modified version of Becke scheme that is applicable to functions of the electronic continuum, such as those involved in molecular photoionization and electron–molecule scattering, and which ensures convergence and efficiency comparable to those realized in the calculation of bound states. In this modified scheme, the atomic weights already present in Becke’s partition are smoothly switched off within a range of few bond lengths from their respective nuclei, and complemented by an asymptotically unitary weight. The atomic integrals are evaluated on small spherical grids, centered on each atom, with size commensurate to the support of the corresponding atomic weight. The residual integral of the interstitial and long-range region is evaluated with a central master grid. The accuracy of the method is demonstrated by evaluating integrals involving integrands containing Gaussian Type Orbitals and Yukawa potentials, on the atomic sites, as well as spherical Bessel functions centered on the master grid. These functions are representative of those encountered in realistic electron-scattering and photoionization calculations in polyatomic molecules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Zigzag flow reactor for weekly thermochemical energy storage

This paper describes theoretical models and experimental performance of a novel Zigzag Flow Reactor (ZFR) for weekly thermochemical energy storage. The ZFR reduces redox-active metal oxide (MO x ) particles at high temperature (up to ~1100 °C) under inert gas sweep. A physical model demonstrates the approach to process equilibrium by minimizing the associated exergy destruction in a finite number of reaction steps, establishing the thermodynamic requirements for a practical reactor. The model results show several cost-relevant parameter tradeoffs, and the tradeoff analysis implies a cost-optimized set of boundary conditions. Numerical models and prototypes show that the ZFR enables significant gas phase homogenization while simultaneously enabling a customizable MO x residence time in the reactor, both key requirements for approaching an equilibrium process. A scaling model demonstrates the simplicity and affordability of sizing the ZFR to grid-scale levels, with fabrication costs at least five times lower than previously proposed scalable reactor concepts. As a result, a laboratory ZFR prototype achieved an energy storage density of ~90 Wh/kg with CaAl 0.2 Mn 0.8 O 3-δ as the MO x , at temperatures of ~850 °C in >10 h of total runtime.

Thermochemical energy storage↗

National population mapping from sparse survey data: A hierarchical Bayesian modeling framework to account for uncertainty

Population estimates are critical for government services, development projects, and public health campaigns. Such data are typically obtained through a national population and housing census. However, population estimates can quickly become inaccurate in localized areas, particularly where migration or displacement has occurred. Some conflict-affected and resource-poor countries have not conducted a census in over 10 y. We developed a hierarchical Bayesian model to estimate population numbers in small areas based on enumeration data from sample areas and nationwide information about administrative boundaries, building locations, settlement types, and other factors related to population density. We demonstrated this model by estimating population sizes in every 10- m grid cell in Nigeria with national coverage. These gridded population estimates and areal population totals derived from them are accompanied by estimates of uncertainty based on Bayesian posterior probabilities. The model had an overall error rate of 67 people per hectare (mean of absolute residuals) or 43% (using scaled residuals) for predictions in out-of-sample survey areas (approximately 3 ha each), with increased precision expected for aggregated population totals in larger areas. This statistical approach represents a significant step toward estimating populations at high resolution with national coverage in the absence of a complete and recent census, while also providing reliable estimates of uncertainty to support informed decision making.

99 GENERAL AND MISCELLANEOUS↗

Dynamic Modeling of Full Converter Adjustable-speed Pumped Storage Hydropower (FC AS-PSH)

Full converter adjustable-speed pumped storage hydropower (FC AS-PSH) technology, as one of advanced-PSH technology, is developed from wind turbine technology. By making the synchronous machine connect to the grid through a full-size converter, FC AS-PSH has a wider adjustment range of speed and a better reactive power control capability compared with a doubly-fed asynchronous generator AS-PSH technology. When it plays as an energy backup in the power system, FC AS-PSH can provide a much faster response than conventional-PSH (C-PSH) which makes this technology provide better ancillary service for a high renewable penetrated system. In this paper, the dynamic modeling of FC AS-PSH is fully studied. We develop a detailed model of this technology in the IEEE 14-bus system based on GE Positive Sequence Load Flow (PSLF) platform. Especially, the first governor model is developed based on the Engineer’s Program Control Language (EPCL) user-defined model in this platform. All operation modes are validated and studied under a system contingency. Besides, comparison cases between FC AS-PSH and C-PSH are studied to show advantages providing from FC AS-PSH when it works with renewable energy.

50 EE - Wind and Water Power Program - Water (EE-4↗

Grid Capacity – What is it, what determines it, does one number work, and how does it relate to electric vehicles?

Grid capacity is effectively how much power the system can reliably deliver, whether that is to serve loads (load service capacity) or accept generation (hosting capacity). Grid capacity can also mean different things at different scales. On the whole power system, grid capacity may be the maximum amount of power generation available. For a specific region, grid capacity may be limited by how much power the transmission and distribution lines can safely carry to that region. At the feeder level, it may be how much photovoltaic generation can be included before reliability or operations are impacted. At the end-use or residential level, grid capacity may be the size of the service breaker for that house.

24 POWER TRANSMISSION AND DISTRIBUTION↗

POPSnet-SGP: A Pilot Aerosol Microphysics Network for Targeting Climate Model Uncertainty Interim Field Campaign Report

Aerosols mediate the radiative fluxes in clear and cloudy skies and dominate the uncertainty in the radiative forcing of climate. Relatively dense networks of aerosol optical depth measurements have been used to effectively constrain simulated aerosol optical properties, but model diversity of aerosol microphysical properties is much larger (Mann et al. 2014, Myhre et al. 2009). A better understanding of aerosol microphysics is essential as they are the fundamental pieces of information required to convert aerosol emissions information to radiative and cloud-nucleating properties that drive radiative effects and forcing of climate. Model representation of aerosol microphysical properties has lagged in part due to their inherently greater spatial variability, but also due to a lack of available observations. This project – the Printed Optical Particle Spectrometer Network (POPSnet)-Southern Great Plains (SGP) Pilot – launched the first spatially dense network of aerosol size distribution measurements over an area the size of a global model grid cell and demonstrated its use in providing valuable information regarding the spatial variability of aerosol microphysical properties and its drivers for improving model constraints.

54 ENVIRONMENTAL SCIENCES↗

Sparse Linear Solvers for Large-scale Electromagnetic Transient Simulations

Linear solvers form the basis for electromagnetic transient (EMT) simulations. There is a need to speed up EMT simulations as larger regions are analyzed using EMT simulations. For the same, the performance of linear solvers plays an important role. Exploiting the sparsity of the matrices generated in EMT simulations could assist with speed-up. Scalability is also crucial as power grids expand, demanding solutions capable of accommodating the increasing system size. Recent studies from the North American Electric Reliability Corporation (NERC) increasingly emphasize that EMT simulation models of the power grid will grow larger with the inclusion of power electronics components. Parallelisms in sparsity patterns exploit modern central processing units (CPUs), multi-core CPUs, and graphics processing units (GPUs) architectures in sparse solver designs. Therefore, this paper explores publicly available existing linear solvers and investigates their efficiency in large-scale power grid simulations. A large-scale power grid is developed by increasing the size of the IEEE 39 bus test system to up to 39000 bus systems.

Hsu, Kuan-Chieh↗

Solar Resource and Infrastructure Assessment for the Town of Westhampton

This report is a solar resource and infrastructure assessment for the town of Westhampton, Massachusetts. The assessment was funded through the National Renewable Energy Laboratory, Solar Energy Innovation Network (NREL SEIN) Solar in Rural Communities Program, as part of a project to develop a Community-Informed Proactive Solar Siting and Financing Model. As a first step, the project lead organization, UMass Clean Energy Extension prepared an assessment of existing infrastructure, resources, and potential solar development opportunities in participating municipalities, including Westhampton. This assessment was designed to describe relevant bylaws and infrastructure within the town, identify the types of solar facilities that could be developed, and quantify the total space available for each type of facility. In this report, we reviewed existing electricity grid infrastructure, and the potential to interconnect additional solar facilities. At the present time, both distribution lines providing electricity to Westhampton are oversaturated with authorized and proposed solar projects, and cannot accommodate additional solar projects to interconnect to the grid. Future upgrades could potentially free up additional capacity for new, large projects. Meanwhile, most three-phase lines could likely accommodate additional small-to-medium scale projects (under 200 kW), and most single-phase lines could likely accommodate additional projects under 50 kW in size. This description represents the local grid infrastructure as it is - planning for future scenarios of development could include recommendations for areas of grid infrastructure improvement to allow siting of distributed generation in locations preferred by the community. Future scenarios may also include the addition energy storage and other "non-wires alternatives."

14 SOLAR ENERGY↗

An economic assessment of behind-the-meter photovoltaics paired with batteries on the Hawaiian Islands.

Due to natural variability and uncertainty, the ever-increasing penetration of solar generation in Hawaii presents challenges to power grid operators to maintain reliable system operation. Demand response (DR) has the potential to be a cost-effective tool for Hawaii to reach its aggressive renewable energy goals while maintaining the reliability of power grids. The Hawaii Public Utilities Commission has approved the Hawaiian Electric Company's revised portfolio of DR programs. The companies have released a grid services purchase agreement and subscribed an initial tranche of load into their DR programs. This paper presents innovative analytical methods and comprehensive economic assessment for distributed photovoltaics (PV) paired with battery energy storage systems (BESSs) for two new DR programs, including fast frequency response and capacity grid service. Optimal dispatch and sizing methods are proposed for the paired system considering different tariff schedules and PV compensation programs across five islands. It was found that while the best resource configuration and potential economic benefits vary with tariff structure, a BESS paired with PV can be optimally dispatched to generate multiple value streams simultaneously. Compensation from DR programs is an important value stream to help increase the cost-effectiveness of the integrated system.

Battery energy storage system↗

Simulations for Planning of Liquid Hydrogen Spill Test

In order to better understand the complex pooling and vaporization of a liquid hydrogen spill, Sandia National Laboratories is conducting a highly instrumented, controlled experiment inside their Shock Tube Facility. Simulations were run before the experiment to help with the planning of experimental conditions, including sensor placement and cross wind velocity. This paper describes the modeling used in this planning process and its main conclusions. Sierra Suite’s Fuego, an in-house computational fluid dynamics code, was used to simulate a RANS model of a liquid hydrogen spill with five crosswind velocities: 0.45, 0.89, 1.34, 1.79, and 2.24 m/s. Two pool sizes were considered: a diameter of 0.85 m and a diameter of 1.7. A grid resolution study was completed on the smaller pool size with a 1.34 m/s crosswind. A comparison of the length and height of the plume of flammable hydrogen vaporizing from the pool shows that the plume becomes longer and remains closer to the ground with increasing wind speed. The plume reaches the top of the facility only in the 0.45 m/s case. From these results, we concluded that it will be best for the spacing and location of the concentration sensors to be reconfigured for each wind speed during the experiment.

08 HYDROGEN↗

Solar Resource and Infrastructure Assessment for the Town of Wendell

This report is a solar resource and infrastructure assessment for the town of Wendell, Massachusetts. The assessment was funded through the National Renewable Energy Laboratory, Solar Energy Innovation Network (NREL SEIN) Solar in Rural Communities Program, as part of a project to develop a Community-Informed Proactive Solar Siting and Financing Model. As a first step, the project lead organization, UMass Clean Energy Extension prepared an assessment of existing infrastructure, resources, and potential solar development opportunities in participating municipalities, including Wendell. This assessment was designed to describe relevant bylaws and infrastructure within the town, identify the types of solar facilities that could be developed, and quantify the total space available for each type of facility. In this report, we reviewed existing electricity grid infrastructure, and the potential to interconnect additional solar facilities. At the present time, both distribution lines providing electricity to Wendell are over-saturated with authorized and proposed solar projects, and cannot accommodate additional solar projects to interconnect to the grid. It appears that National Grid is planning an upgrade to the Wendell Depot substation, which might then allow in-process projects are to proceed, and potentially free up additional capacity for new, large projects. Meanwhile, most three-phase lines could likely accommodate additional small-to-medium scale projects (under 200 kW), and most single-phase lines could likely accommodate additional projects under 50 kW in size. This description represents the local grid infrastructure as it is - planning for future scenarios of development could include recommendations for areas of grid infrastructure improvement to allow siting of distributed generation in locations preferred by the community. Future scenarios may also include the addition energy storage and other "non-wires alternatives."

14 SOLAR ENERGY↗

ABACUSSUMMIT : a massive set of high-accuracy, high-resolution N -body simulations

We present the public data release of the AbacusSummit cosmological N-body simulation suite, produced with the Abacus N-body code on the Summit supercomputer of the Oak Ridge Leadership Computing Facility. Abacus achieves $\mathcal {O}(10^{-5})$ median fractional force error at superlative speeds, calculating 70M particle updates per second per node at early times, and 45M particle updates per second per node at late times. The simulation suite totals roughly 60 trillion particles, the core of which is a set of 139 simulations with particle mass $2\times 10^{9}\, h^{-1}\, \mathrm{M}_\odot$ in box size $2\, h^{-1}\, \mathrm{Gpc}$. The suite spans 97 cosmological models, including Planck 2018, previous flagship simulation cosmologies, and a linear derivative and cosmic emulator grid. A subsuite of 1883 boxes of size $500\, h^{-1}\, \mathrm{Mpc}$ is available for covariance estimation. AbacusSummit data products span 33 epochs from z = 8 to 0.1 and include light cones, full particle snapshots, halo catalogues, and particle subsets sampled consistently across redshift. AbacusSummit is the largest high-accuracy cosmological N-body data set produced to date.

79 ASTRONOMY AND ASTROPHYSICS↗

Adaptive primal–dual control for distributed energy resource management

With the increased adoption of distributed energy resources (DERs) in distribution networks, their coordinated control with a DER management system (DERMS) that provides grid services (e.g., voltage regulation, virtual power plant) is becoming more necessary. One particular type of DERMS using primal–dual control has recently been found to be very effective at providing multiple grid services among an aggregation of DERs; however, the main parameter, the primal–dual step size, must be manually tuned for the DERMS to be effective, which can take a considerable amount of engineering time and labor. To this end, we design a simple method that self-tunes the step size(s) and adapts it to changing system conditions. Additionally, it gives the DER management operator the ability to prioritize among possibly competing grid services. Here we evaluate the automatic tuning method on a simulation model of a real-world feeder in Colorado with data obtained from an electric utility. Through a variety of scenarios, we demonstrate that the DERMS with automatically and adaptively tuned step sizes provides higher-quality grid services than a DERMS with a manually tuned step size.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar Resource and Infrastructure Assessment for the Town of Blandford

This report is a solar resource and infrastructure assessment for the town of Blandford, Massachusetts. The assessment was funded through the National Renewable Energy Laboratory, Solar Energy Innovation Network (NREL SEIN) Solar in Rural Communities Program, as part of a project to develop a Community-Informed Proactive Solar Siting and Financing Model. As a first step, the project lead organization, UMass Clean Energy Extension prepared an assessment of existing infrastructure, resources, and potential solar development opportunities in participating municipalities, including Blandford. This assessment was designed to describe relevant bylaws and infrastructure within the town, identify the types of solar facilities that could be developed, and quantify the total space available for each type of facility. In this report, we reviewed existing electricity grid infrastructure, and the potential to interconnect additional solar facilities. At the present time, most distribution lines providing electricity to Blandford are over-saturated with authorized and proposed solar projects, and cannot accommodate additional solar projects to interconnect to the grid. We can expect significant upgrades to these circuits, if any of the in-process projects are to proceed, which might then free up additional capacity for new projects. There is one circuit which serves a section of North Blandford Road that is not over-saturated; for the immediate future, this is the most cost-effective location for new large-scale projects to be sited. Meanwhile, most three-phase lines could likely accommodate additional small-to-medium scale projects (under 200 kW), and most single-phase lines could likely accommodate additional projects under 50 kW in size. This description represents the local grid infrastructure as it is - planning for future scenarios of development could include recommendations for areas of grid infrastructure improvement to allow siting of distributed generation in preferred locations. Future scenarios may also include the addition energy storage and other "non-wires alternatives."

14 SOLAR ENERGY↗

7.2 kV Three-Port SiC Single-Stage Current-Source Solid-State Transformer With 90 kV Lightning Protection

This article proposes a multiport modular single-stage current-source solid-state transformer (SST) for applications like photovoltaic, energy storage integration, electric vehicle fast charging, data center, etc. The 7.2 kV 50 kVA current-source SST consists of five input-series output-parallel modules, each based on 3.3 kV SiC reverse-blocking MOSFET-plus-diode modules. The proposed SST has some unique features. First, compared to the voltage-source or matrix converter-based SSTs, the current-source SST has a unique advantage of single-stage isolated AC/DC or AC/AC conversion with an inductive DC link, but no medium-voltage (MV) AC experiments have been reported. This article for the first time demonstrates MV AC current-source SST up to 7.5 kV peak. Second, the multiport SST has a buffer port for active power decoupling (APD) or energy storage integration. The double-line-frequency power ripple from single-phase AC grid normally results in a large capacitor size in MV SSTs. The APD scheme is proposed in MV applications for the first time to enable a reduced DC link and the electrolytic capacitor-less SST with high reliability. Third, as a direct grid-connected converter without line-frequency transformer, insulation and protection are critical. A medium-frequency transformer design passes 55 kV basic-insulation level (BIL) and 60 kV high potential dielectrics withstand test with only 0.09% leakage inductance. Importantly, a lightning protection scheme is presented to protect the SST itself from 90 kV BIL impulse. Fourth, the proposed current-source SST topology is a modular soft-switching solid-state transformer (M-S4T) with full-range zero-voltage switching and controlled dv/dt for low electromagnetic interference. Furthermore, these concepts are verified in a three-port M-S4T prototype with forced oil cooling under single-module, stacked-module, steady-state, and dynamic operations.

14 SOLAR ENERGY↗