Particle Heat Exchangers: Development and Testing of a 20 kWt Moving Packed-Bed Particle-to-sCO2 Heat Exchanger.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
The growing interest in additively manufactured (AM) heat exchangers drove the need to understand how this construction technique impacts heat exchanger performance. Two primary factors driven by AM that influence heat exchanger performance are surface roughness and geometry. To better understand these parameters, a range of shell and tube heat exchangers constructed using laser powder bed fusion were evaluated. Of those evaluated, the surface roughness throughout a fourteen-tube, zero-baffle heat exchanger was measured using computed tomography. Between the inner and outer tubes, the inner tube surfaces had a greater surface roughness than the outer by 8.07 μm, while the surfaces at the top of the build volume had higher surface roughness values than the bottom. Dimensionally, the inner tube diameters of this heat exchanger were 0.15% different from the design value, while the outer diameters were within a 0.84 % difference. Manual measurements across seven other heat exchangers yielded a maximum 1.15% difference between the design and measured diameters. Across the build volume for all heat exchangers studied, the tube diameters at the top were larger than at the bottom by a maximum of 1.24% difference. Inconsistent melting throughout the individual parts and the build volume, as well as particle splatter and thermal gradient variation were attributed to the surface roughness and dimensional changes seen. These results strengthen the knowledge of dimensional and surface roughness considerations when designing AM heat exchangers.
Disclosed is an interdigitated plate-type heat exchanger interface. The interface includes a modular interconnect to thermally connect a pair or pairs of plate-type heat exchangers to a second single or multiple plate-type heat exchanger. The modular interconnect comprises a series of parallel, plate-type heat exchangers arranged in pairs to form a slot therebetween. The plate-type heat exchangers of the second heat exchanger insert into the slots of the modular interconnect. Bellows are provided between the pairs of fins of the modular interconnect so that when the bellows are pressurized, they drive the plate-type heat exchangers of the modular interconnect toward one another, thus closing upon the second heat exchanger plates. Each end of the bellows has a part thereof a thin, membrane diaphragm which readily conforms to the contours of the heat exchanger plates of the modular interconnect when the bellows is pressurized. This ensures an even distribution of pressure on the heat exchangers of the modular interconnect thus creating substantially planar contact between the two heat exchangers. The effect of the interface of the present invention is to provide a dry connection between two heat exchangers whereby the rate of heat transfer can be varied by varying the pressure within the bellows.
Exact solution for wall and fluid temperature distributions for counterflow heat exchanger with effect of longitudinal heat conduction
Plate heat exchangers (PHEs) have been used in numerous industrial applications, such as HVAC systems, power generation, transportation and manufacturing. The performance of plate heat exchangers is frequently undermined by corrosion, fouling, and scaling. These phenomena not only diminish heat transfer efficiency but also lead to increased operational costs, maintenance demands, and reduced equipment lifespan. In this project, the team addressed the widespread challenges of corrosion, fouling, and scaling, and explored alternative material solutions. While commonly used materials like stainless steel and titanium offer notable benefits, they can still experience corrosion under certain operating conditions. The advancement of new materials and surface engineering technologies, such as advanced coating, ceramics, composites materials, and high entropy alloys are promising for can help solve these issues, enable longer lifetime and high performance of plate heat exchangers.
A shuttle orbiter flight configuration aluminum heat exchanger was designed, fabricated, and tested. The heat exchanger utilized aluminum clad titanium composite parting sheets for protection against parting sheet pin hole corrosion. The heat exchanger, which is fully interchangeable with the shuttle condensing heat exchanger, includes slurpers (a means for removing condensed water from the downstream face of the heat exchanger), and both the core air passes and slurpers were hydrophilic coated to enhance wettability. The test program included performance tests which demonstrated the adequacy of the design and confirmed the predicted weight savings.
In sizing a condensing heat exchanger for space life support systems, there is a limit to allowable pressure drop along with a required vapor recuperation rate. This sizing is performed by using known heat transfer and pressure drop correlations in a numerical model. Dimpling the surface of an air-liquid channeled heat exchanger increases the convective heat transfer rate however creates difficulties within the numerical model as the flat plate correlations are no longer accurate. To increase the fidelity of the numerical model used for sizing the heat exchanger Computational Fluid Dynamics (CFD) with an SST k-ω turbulence model was performed on a periodic portion of the heat exchanger. Through CFD modeling a heat flux and pressure drop was measured across the heat exchanger channel, this information was used to create a localized Nusselt number that was incorporated into the numerical model along with a more accurate pressure drop due to the dimpled surface. Additionally, through modeling the heat exchanger after manufacturing and assembly in Computer Aided Drafting (CAD) software there was an increase in the measurement accuracy of geometric features which was incorporated into the numerical model for further increase in fidelity.
Within virtually all reactor systems with heat exchangers, the thinnest barriers between primary and secondary fluids are the heat exchanger tubes. Consistent with light water reactor experience, the advanced reactor heat exchangers are the most susceptible regions for corrosion and leakage (NRC, 2019). Moreover, traditional inspections and repairs using robotics will be expensive or impractical. On-line structural health corrosion monitoring (OLSHM) is therefore desirable to detect tube degradation prior to leaks that may allow mixing of heat exchanger fluids. Rhetorically many molten salt reactor (MSR) designers plan for on-line monitoring of critical reactor components including heat exchangers but there are no proven OLSHM sensors or systems for MSR heat exchangers. Guided wave ultrasound from the tube-end or ID using conventional low-temperature piezoelectric sensors has been shown to be sensitive to pits and cracks less than 50% through-wall in long pipes and tubes (Narayanan M.M., 2019) . Mode and frequency selection are important for practical sensor design decisions and ultimate performance. The L-0 wave-mode is easily excited by L-mode transducers but they have surface normal wave motion that will be sensitive to and more attenuative because of fluid interaction with the tube surface (Rose J.L., 1994). Shear Horizontal (SH) wave modes have material motion parallel to the tube surface therefore are virtually unaffected by fluid interaction. For SH-0 to be nondispersive in steel, the frequency-thickness product (MHz-mm) must be less than approximately 1.5. SH mode transducers must be coupled by a material that can support shear stress; a thin layer of honey works well for temporary sensors and an adhesive or a brazed metallurgical bond for permanent sensors. If sensors are incorporated into the fabrication process, the same kinds of SH-0 waves can be generated from the stagnant flow area of the tube OD without compromising the heat-exchange tube function. Piezoelectric materials are also available that can withstand harsh temperatures of molten salt heat exchangers (Stevenson T., 2015) (Machura et al., 2008). Though they may not have as high-performance characteristics, their performance only needs to be good enough to detect flaws of interest. This project attempts to demonstrate feasibility to develop a sensor that can be sensitive to flaws of interest and perform long-term monitoring of a molten salt reactor heat exchanger. Benefits to the advanced reactor system include: • Minimizing the expense of a reactor shut down for periodic inspection—only shutdown for cause. • Reduce risk of unexpected tube rupture by detecting flaws before they grow to through-wall leaks. • Cost reduction by minimizing need to design for manual/robotic inspectability. Transducer design, characterization of the beam profile, wedges vs. direct application of piezoelectric sensors, and ultrasonic pulse-echo responses from a representative heat exchange tube with fabricated flaw types are discussed.
Air-to-refrigerant heat exchangers (HXs) are fundamental components to HVAC&R systems and as a result there is an ever-increasing need for performance and packaging improvements. Typically, HX’s are designed in uniform arrangements with the goal of providing the necessary heat transfer for minimal material costs. Recent research on fin tube heat exchangers (FTHX) with variation in one or more key parameters has shown significant potential for increasing heat transfer, reducing pressure losses, and making HXs more resilient to environmental externalities like airflow maldistribution and frost accumulation. In particular, researchers have increased heat transfer by 7.6% and j/f by 16% via non-uniform tube and winglet shapes. Additionally, multiple cases have shown that variable geometry heat exchangers (VGHX) are able to match the performance of conventional HXs with reductions in material mass and envelope volume of up to 33% and 40%, respectively. This paper presents a literature review of VGHXs specifically with regards to non-uniform FTHX’s.
Conceptual design for heat exchanger, utilizing two immiscible liquids with dissimilar specific gravities in direct contact, is more efficient mechanism of heat transfer than conventional heat exchangers with walls or membranes. Concept could be adapted for collection of heat from solar or geothermal sources.
Based on a theoretical analysis of convective heat transfer across large internal surface areas, this paper discusses the design implications for generating lightweight gas-gas heat exchanger designs by packaging such areas into compact three-dimensional shapes. Allowances are made for hot and cold inlet and outlet headers for assembly of completed regenerator (or recuperator) heat exchanger units into closed cycle gas turbine flow ducting. Surface area and resulting volume and mass requirements are computed for a range of heat exchanger effectiveness values and internal heat transfer coefficients. Benefit cost curves show the effect of increasing heat exchanger effectiveness on Brayton cycle thermodynamic efficiency on the plus side, while also illustrating the cost in heat exchanger required surface area, volume, and mass requirements as effectiveness is increased. The equations derived for counterflow and crossflow configurations show that as effectiveness values approach unity, or 100 percent, the required surface area, and hence heat exchanger volume and mass tend toward infinity, since the implication is that heat is transferred at a zero temperature difference. To verify the dimensional accuracy of the regenerator mass computational procedure, calculation of a regenerator specific mass, that is, heat exchanger weight per unit working fluid mass flow, is performed in both English and SI units. Identical numerical values for the specific mass parameter, whether expressed in lb/(lb/sec) or kg/(kg/sec), show the dimensional consistency of overall results.
Based on a theoretical analysis of convective heat transfer across large internal surface areas, this paper discusses the design implications for generating lightweight gas-gas heat exchanger designs by packaging such areas into compact three-dimensional shapes. Allowances are made for hot and cold inlet and outlet headers for assembly of completed regenerator (or recuperator) heat exchanger units into closed cycle gas turbine flow ducting. Surface area and resulting volume and mass requirements are computed for a range of heat exchanger effectiveness values and internal heat transfer coefficients. Benefit cost curves show the effect of increasing heat exchanger effectiveness on Brayton cycle thermodynamic efficiency on the plus side, while also illustrating the cost in heat exchanger required surface area, volume, and mass requirements as effectiveness is increased. The equations derived for counterflow and crossflow configurations show that as effectiveness values approach unity, or 100 percent, the required surface area, and hence heat exchanger volume and mass tend toward infinity, since the implication is that heat is transferred at a zero temperature difference. To verify the dimensional accuracy of the regenerator mass computational procedure, calculation of a regenerator specific mass, that is, heat exchanger weight per unit working fluid mass flow, is performed in both English and SI units. Identical numerical values for the specific mass parameter, whether expressed in lb/(lb/sec) or kg/ (kg/sec), show the dimensional consistency of overall results.
A prototype cryogenic heat exchanger for removal of waste heat from a spacecraft environmental control life support system was developed. The heat exchanger uses the heat sink capabilities of the cryogenic propellants and, hence, can operate over all mission phases from prelaunch to orbit, to post landing, with quiescent periods during orbit. A survey of candidate warm fluids resulted in the selection of E-2, a fluorocarbon compound, because of its low freezing point and high boiling point. The final design and testing of the heat exchanger was carried out, however, using Freon-21, which is similar to E-2 except for its low boiling point. This change was motivated by the desire for cost effectiveness of the experimental program. The transient performance of the heat exchanger was demonstrated by an analog simulation of the heat sink system. Under the realistic transient heat load conditions (20 sec ramp from minimum to maximum Freon-21 inlet temperature), the control system was able to maintain the warm fluid outlet temperature within + or - 3 F. For a 20-sec ramp from 0 F to -400 F in the hydrogen inlet temperature, at maximum heat load, the warm fluid outlet temperature was maintained within + or - 7 F.
Traditional heat exchanger designs have relied on a plate-fin architecture, assembled in a crossflow configuration. These HX designs are limited in their maximum allowable temperature and, therefore, efficiency. More advanced designs, such as those containing counter-flow, microtube cores, can yield higher efficiencies, but generally require complex headers. The design of such headers is usually determined based on user experience rather than on rigorous design tools, which can lead to lossy architectures; conventional headers can generate up to 50% of the total pressure loss through the HX. Furthermore, the consequences of manufacturing techniques are rarely considered during the design phase. Our team has developed an ultra-compact, topology-optimized heat exchanger capable of operating in environments with temperatures and pressures up to 800°C (1472°F) and 250 bar (3626 psi), respectively. Throughout the program, the team leveraged extensive additive manufacturing research and experience in supercritical carbon dioxide (sCO 2 ) power generation experience to develop and commercialize the technology. The final power density numbers for the subscale and full-scale heat exchangers are >15 kW/kg and >50 kW/L, which includes the core and the headers. The team has involved the RTX business units, notably Collins Aerospace, in discussions for commercializing the technology.
An improved lightweight heat exchanger particularly suited for use in systems having low volume flow, high longitudinal gradient and high effectiveness requirements is described. The heat exchanger is characterized by a shell of an annular configuration, an endless plate of minimal thickness and of a substantially uniformly convoluted configuration disposed within the annular shell for defining a plurality of endless, juxtaposed passages, each having a low Reynold's number and being of an annular configuration. A pair of manifolds disposed 180 deg apart is mounted on the shell in communication with the passages through which counterflowing fluids are simultaneously introduced and extracted from the passageways for achieving a continuous transfer of heat through the convoluted plate.
Within virtually all reactor systems with heat exchangers, the thinnest barriers between primary and secondary fluids are the heat exchanger tubes. Consistent with light water reactor experience, the advanced reactor heat exchangers are the most susceptible regions for corrosion and leakage (NRC, 2019). Moreover, traditional inspections and repairs using robotics will be expensive or impractical. On-line structural health corrosion monitoring (OLSHM) is therefore desirable to detect tube degradation prior to leaks that may allow mixing of heat exchanger fluids. Rhetorically many molten salt reactor (MSR) designers plan for on-line monitoring of critical reactor components including heat exchangers but there are no proven OLSHM sensors or systems for MSR heat exchangers. Guided wave ultrasound from the tube-end or ID using conventional low-temperature piezoelectric sensors has been shown to be sensitive to pits and cracks less than 50% through-wall in long pipes and tubes (Narayanan M.M., 2019) . Mode and frequency selection are important for practical sensor design decisions and ultimate performance. The L-0 wave-mode is easily excited by L-mode transducers but they have surface normal wave motion that will be sensitive to and more attenuative because of fluid interaction with the tube surface (Rose J.L., 1994). Shear Horizontal (SH) wave modes have material motion parallel to the tube surface therefore are virtually unaffected by fluid interaction. For SH-0 to be nondispersive in steel, the frequency-thickness product (MHz-mm) must be less than approximately 1.5. SH mode transducers must be coupled by a material that can support shear stress; a thin layer of honey works well for temporary sensors and an adhesive or a brazed metallurgical bond for permanent sensors. If sensors are incorporated into the fabrication process, the same kinds of SH-0 waves can be generated from the stagnant flow area of the tube OD without compromising the heat-exchange tube function. Piezoelectric materials are also available that can withstand harsh temperatures of molten salt heat exchangers (Stevenson T., 2015) (Machura et al., 2008). Though they may not have as high-performance characteristics, their performance only needs to be good enough to detect flaws of interest. This project attempts to demonstrate feasibility to develop a sensor that can be sensitive to flaws of interest and perform long-term monitoring of a molten salt reactor heat exchanger. Benefits to the advanced reactor system include: • Minimizing the expense of a reactor shut down for periodic inspection—only shutdown for cause. • Reduce risk of unexpected tube rupture by detecting flaws before they grow to through-wall leaks. • Cost reduction by minimizing need to design for manual/robotic inspectability. Transducer design, characterization of the beam profile, and ultrasonic pulse-echo responses from a representative heat exchange tube with fabricated flaw types are discussed.
High-performance microchannel heat exchangers are needed to supply heat for power conversion for nuclear microreactors. An airfoil fin microchannel design, constructed of Alloy 617 with helium as the working fluid, is analyzed and optimized using a design of experiments with artificial intelligence techniques. The use of airfoil fins offers the potential to reduce pressure drop across the heat exchanger, as compared to other types of channel configurations. A framework for topology optimization of airfoil fin printed circuit heat exchangers (PCHEs) has been developed that can be readily extended to different fin sizes and shapes, as well as different inlet and operating conditions, materials of construction, and working fluids. An optimization procedure is developed that employs computational fluid dynamics for a set of design points identified using Latin hypercube sampling. Computational fluid dynamics is used to analyze a simplified two-channel configuration where five design parameters are varied – inlet angle, fin scale, extent of staggering, transverse and longitudinal pitches. Two methods (a 5D polynomial and a regression neural network) are compared for generating surrogate models and the resulting response surface approximation is input to a genetic algorithm that is used to identify a set of optimal parameters. The optimal geometries are found across six channel Reynolds numbers ranging from 1000 to 5000, since inlet conditions affect flow through the heat exchanger. Additionally, a set of optimal designs that maximizes heat transfer and minimizes pressure drop is identified, and a thermal stress analysis is performed on the optimal design. Correlations for the Nusselt number and Darcy friction factor are developed that can be useful for thermal hydraulic analyses using system codes. Thermal stresses are analyzed and a brief discussion of the status of code cases of PCHEs for nuclear applications is given. Testing and thermomechanical modeling is needed to facilitate future code compliance of PCHEs for high pressure and high temperature applications.
High-performance microchannel heat exchangers are needed to supply heat for power conversion for nuclear microreactors. An airfoil fin microchannel design, constructed of Alloy 617 with helium as the working fluid, was analyzed and optimized using a design of experiments with artificial intelligence and machine learning techniques. The use of airfoil fins offers the potential to reduce pressure drop across the heat exchanger, as compared to other types of channel configurations. A framework for topology optimization of airfoil fin PCHEs has been developed that can be readily extended to different fin sizes and shapes, as well as different inlet and operating conditions, materials of construction, and working fluids. An optimization procedure was developed that employs computational fluid dynamics for a set of design points identified using Latin hypercube sampling. STAR-CCM+ was used to analyze a simplified two-channel configuration where five parameters were varied – inlet angle, fin scale, extent of staggering, transverse and longitudinal pitches. Two methods were compared for generating surrogate models – a 5D polynomial and a regression neural network. A response surface approximation was created from the surrogate models and input to a genetic algorithm. The genetic algorithm identified a set of optimal points on the Pareto front. The optimal geometry was found across six channel Reynolds numbers ranging from 1000 to 5000 to analyze how varying inlet conditions affects the optimal design. A set of optimal designs that maximizes heat transfer and minimizes pressure drop was identified, and a thermal stress analysis was performed on the optimal design. This work has developed a digital framework for the expedient topology design and evaluation of PCHE designs for gas-cooled microreactor applications. Correlations for the Nusselt number and Darcy friction factor were developed that can be useful for thermal hydraulic analyses using system codes. A thermal stress analysis was conducted and a brief discussion of the status of code cases of PCHEs for nuclear applications is given. Testing and thermomechanical modeling is needed to facilitate future code compliance of PCHEs for high pressure and high temperature applications.