Search NASA⌕ Search

SEARCH · Search NASA

Results for “helium bubble”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

115 records · Page 7

Using Electrostriction to Manipulate Ullage in Microgravity

A report proposes to use electrostriction to manipulate the ullage in a tank containing a dielectric liquid in a microgravitational environment. In the original intended application, the liquid would be a spacecraft propellant and the goal would be to force the ullage (comprising bubbles of noncondensible gas) to coalesce at one end of the tank, to enable use of one of the established means of (1) measuring the position of the gas/liquid interface and (2) inferring the quantity of liquid from the measurement. Electrically insulated wires would be installed in the tank, shaped and positioned so that application of a suitably high potential (e.g., 1 kV) between adjacent wires in successive pairs would give rise to a sufficient electric field gradient along the tank. The resulting electrostriction in the liquid would give rise to a pressure gradient that would force the ullage toward the low-electric-field-magnitude end of the tank. The feasibility of this proposal was demonstrated in an experiment in a tank containing liquid helium aboard an airplane flying a low-gravity arc. The ullage-segregating electrostrictive effect is expected to be considerably greater in other liquids.

Chui, Talso↗

Observed Limits on Charge Exchange Contributions to the Diffuse X-Ray Background

We present a high-resolution spectrum of the diffuse X-ray background from 0.1 to 1 keV for an approximately 1 sr region of the sky centered at l = 90 degrees b = +60 degrees using a 36 pixel array of microcalorimeters flown on a sounding rocket. With an energy resolution of 11 eV FWHM below 1 keV, the spectrum s observed line ratios help separate charge exchange contributions originating within the heliosphere from thermal emission of hot gas in the interstellar medium. The X-ray sensitivity below 1 keV was reduced by about a factor of four from contamination that occurred early in the flight, limiting the significance of the results. The observed centroid of helium-like O VII is 568 (sup +2 (sub -3) eV at 90% confidence. Since the centroid expected for thermal emission is 568.4 eV and for charge exchange is 564.2 eV, thermal emission appears to dominate for this line complex. The dominance of thermal emission is consistent with much of the high-latitude O VII emission originating in 2-3 x 10(exp 6) K gas in the Galactic halo. On the other hand, the observed ratio of C VI Lygamma to Lyalpha is 0.3 plus or minus 0.2. The expected ratios are 0.04 for thermal emission and 0.24 for charge exchange, indicating that charge exchange must contribute strongly to this line and therefore potentially to the rest of the ROSAT R12 band usually associated with 10(sup 6) K emission from the Local Hot Bubble. The limited statistics of this experiment and systematic uncertainties due to the contamination require only greater than 32% thermal emission for O VII and greater than 20% from charge exchange for C VI at the 90% confidence level. An experimental gold coating on the silicon substrate of the array greatly reduced extraneous signals induced on nearby pixels from cosmic rays passing through the substrate, reducing the triggered event rate by a factor of 15 from a previous flight of the instrument.

Crowder, S. G.↗

Observed Limits on Charge Exchange Contributions to the Diffuse X-Ray Background

We present a high-resolution spectrum of the diffuse X-ray background from 0.1 to 1 keV for an approximately 1 sr region of the sky centered at l = 90 degrees b = +60 degrees using a 36 pixel array of microcalorimeters flown on a sounding rocket. With an energy resolution of 11 eV FWHM below 1 keV, the spectrum s observed line ratios help separate charge exchange contributions originating within the heliosphere from thermal emission of hot gas in the interstellar medium. The X-ray sensitivity below 1 keV was reduced by about a factor of four from contamination that occurred early in the flight, limiting the significance of the results. The observed centroid of helium-like O VII is 568 (sup +2 (sub -3) eV at 90% confidence. Since the centroid expected for thermal emission is 568.4 eV and for charge exchange is 564.2 eV, thermal emission appears to dominate for this line complex. The dominance of thermal emission is consistent with much of the high-latitude O VII emission originating in 2-3 x 10(exp 6) K gas in the Galactic halo. On the other hand, the observed ratio of C VI Lygamma to Lyalpha is 0.3 plus or minus 0.2. The expected ratios are 0.04 for thermal emission and 0.24 for charge exchange, indicating that charge exchange must contribute strongly to this line and therefore potentially to the rest of the ROSAT R12 band usually associated with 10(sup 6) K emission from the Local Hot Bubble. The limited statistics of this experiment and systematic uncertainties due to the contamination require only greater than 32% thermal emission for O VII and greater than 20% from charge exchange for C VI at the 90% confidence level. An experimental gold coating on the silicon substrate of the array greatly reduced extraneous signals induced on nearby pixels from cosmic rays passing through the substrate, reducing the triggered event rate by a factor of 15 from a previous flight of the instrument.

Crowder, S. G.↗

Portable Microleak-Detection System

The figure schematically depicts a portable microleak-detection system that has been built especially for use in testing hydrogen tanks made of polymer-matrix composite materials. (As used here, microleak signifies a leak that is too small to be detectable by the simple soap-bubble technique.) The system can also be used to test for microleaks in tanks that are made of other materials and that contain gases other than hydrogen. Results of calibration tests have shown that measurement errors are less than 10 percent for leak rates ranging from 0.3 to 200 cm3/min. Like some other microleak-detection systems, this system includes a vacuum pump and associated plumbing for sampling the leaking gas, and a mass spectrometer for analyzing the molecular constituents of the gas. The system includes a flexible vacuum chamber that can be attached to the outer surface of a tank or other object of interest that is to be tested for leakage (hereafter denoted, simply, the test object). The gas used in a test can be the gas or vapor (e.g., hydrogen in the original application) to be contained by the test object. Alternatively, following common practice in leak testing, helium can be used as a test gas. In either case, the mass spectrometer can be used to verify that the gas measured by the system is the test gas rather than a different gas and, hence, that the leak is indeed from the test object.

Rivers, H. Kevin↗

Rewet Temperature Correlations for Liquid-Nitrogen Boiling Pipe Flows Across Varying Flow Conditions and Orientations

In many convective liquid-vapor phase change heat transfer engineering applications, cryogenic fluids are widely used in industrial processes, spacecraft and cryosurgery systems, and so on. For example, cryogens are usually used as liquid fuels such as liquid hydrogen and oxygen in the rocket industry, liquid nitrogen (LN2) and helium are frequently used to cool superconducting magnetic device for medical applications. In these systems, proper transport, handling, and storage of cryogenic fluids are of extreme importance. Among all the cryogenic transport processes performed in room temperatures, quenching, also termed chilldown, is a unavoidable initial, transient phase-change heat transfer process that brings the system down to the cryogenic condition. The Leidenfrost temperature or rewet temperature that signals the end of film boiling is practically considered the completion point of a quenching process. Therefore, rewet temperature has been considered the most important parameter for the engineering design of cryogenic thermal management systems. As most of the previous correlations for predicting the Leidenfrost temperature and the rewet temperature have been basically developed for water, they are shown to disagree with recent liquid nitrogen pipe chilldown experiments in upward and downward flow directions over a wide range of flow rates, pressures, and degrees of inlet subcooling. In addition to a complete review of the literature, two new correlations are presented in this work, one based on bubble growth and another based on the theoretical maximum limit of superheat. Each correlation performs well over the entire data set.

liquid nitrogen↗

Consequences of a conductive boundary on the local cloud. I - No dust

Using boundary conditions appropriate to the Local Cloud embedded in the Local Bubble, the evaporation of the cloud is modeled assuming steady flow. Included in the model are the effects of radiative cooling and nonequilibrium ionization structure in the interface, and pressure support and heat conduction inhibition due to the magnetic field. The soft X-ray and EUV emission from the interface are calculated and compared with observations. It is found that the emission in the softest X-ray band, the Be band, is harder than that calculated for an equilibrium, normal abundance, 10 to the 6th K plasma. Column densities of C IV, N V, O VI, Si IV, and Si III in the interface are calculated. The column density for O VI is found to be very close to observed values for nearby stars, while all others are too small to contribute significantly to observed values. The ionization of the Local Cloud due to radiation from the interface is calculated. It is found that a significant amount of ionizing radiation is produced, dominating all other known sources. The hardness of the emission, however, results in ionization of helium as well as hydrogen. Thus, the type of boundary modeled cannot explain the ionization of the very local interstellar medium inferred from solar backscatter measurements.

Slavin, Jonathan D.↗

Explosions of infalling comets in Jupiter's atmosphere

In view of the expected collision of comet Shoemaker-Levy 9 (1993e) with Jupiter in 1994 July, we calculate basic properties of the initial interaction for a simplified Jovian atmosphere. The comet is expected to impact Jupiter at 60 km/sec and at an angle of 45 deg to the zenith. The shock wave generated by the bolide should be optically thick once it has penetrated to an atmospheric density approximately 10(exp -6) gr/cm(exp 3), and we calculate the post-shock conditions assuming local thermodynamic equilibrium (LTE) for shock velocities v(sub sh) in the range 10 to 60 km/sec and preshock densities rho(sub a) = 10(exp -6) to 10(exp -2) gr/cm(exp 3). Our shock calculations include molecular hydrogen, atomic hydrogen, ionized hydrogen, neutral helium, and singly ionized helium. Even at the highest shock velocity, the gas is only partially ionized and the postshock temperature rises with preshock density in order to maintain the ionization. The value of the effective shock adiabatic index gamma(sub sh) varies from 1.17 (at low v(sub sh) and rho(sub a) to 1.40 (at high v(sub sh) and rho(sub a). The ablation rate is limited by the radiative flux that reaches the bolide surface. We argue that the ablated gas does not efficiently transfer its kinetic energy to the atmosphere, and it ultimately slows in a similar fashion to the comet material. As the bolide initially falls through the atmosphere, the character of the shock emission changes. At rho(sub a) approximately 10(exp -8) gr/cm (exp 3), the gas is optically thin and we expect line emission; in the optical spectrum, Balmer emission is expected from the shocked atmosphere and low-ionization metal lines from ablated cometary material. At rho(sub a) approximately 10(exp -6) gr/m(exp 3), the shocked gas is optically thick and the shock front near the bolide produces a blackbody spectrum. The temperature is favorable for ultraviolet (1000 to 3000 A) emission and the luminosity may be approximately 5 x 10(exp 23) ergs/sec for approximately 0.6 sec for a bolide 1 km in radius. At rho(sub a) approximately 10(exp -4) gr/cm(exp 3), the bolide has passed below the ultraviolet photosphere. The shock front emits considerable ionizing radiation, but it is absorbed in a narrow preshock region. The bolometric correction for the optical luminosity is large and we expect a 3000 to 8000 A luminosity of approximately 3 x 10(exp 23) ergs/sec for approximately 1 sec. The optical emission is strongly peaked in the vicinity of the bolide. The bolide does have a somewhat less luminous, optically thick trail extending greater than or equal to 10 km, but the radiation is characterized by a temperature of 4000 to 5000 K. From the fragmentation model of Chyba, Thomas, & Zahnle (1993), the bolide deposits most of its kinetic energy at rho(sub a) approximately 10(exp -3) gr/cm(exp 3) and this is the effective explosion site. The shock wave from such an explosion can move up about one density scale height. We examine the breakout of the shock front from the Jovian atmosphere and find that the shock acceleration in the decreasing density region is slow, so that the energy flux in the shock front is small. Higher velocities might be generated by shock acceleration along the channel left by the bolide if the shock motion can occur before the channel closes off as a result of radiative cooling. Hot gas created by the explosion ultimately rises due to buoyancy on a timescale of a minute. The luminosity is highest when the bubble first rises into the optically thin part of the atmosphere and may be approximately 1 x 10(exp 25) ergs/sec in the near-infrared. Roughly 1% of the initial bolide energy may be radiated in this way; the rest of the energy is lost to sound waves from the initial explosion and to work done by the bubble on the surrounding atmosphere.

Chevalier, Roger A.↗