Search NASA⌕ Search

SEARCH · Search NASA

Results for “high - contrast imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Fresnel zone plate development for x-ray radiography of hydrodynamic instabilities at the National Ignition Facility

The study of Rayleigh–Taylor (RT) and Richtmyer–Meshkov (RM) instabilities in a planar geometry at high energy densities at the National Ignition Facility (NIF) requires high spatial resolution imaging. We demonstrate the potential of Fresnel zone plates (FZPs) to achieve resolution that would unlock such studies. FZPs are circular aperiodic gratings that use diffraction to focus x rays and produce an image with high spatial resolution. Taking into account the NIF’s challenging environment, we have designed a specific array of five FZPs for a zinc backlighter to take a radiograph of a target with 9 keV x rays. We measured a mean resolution for the FZP of 1.9µm±0.5µm and a ±1mm depth of focus at an x-ray calibration facility as well as a 2.3µm±0.4µm resolution on a resolution wire mesh shot on the NIF. We also performed an in-depth analysis of the image quality to assess the capability to resolve the small features present in RT and RM instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ high-temperature 3D imaging of the damage evolution in a SiC nuclear fuel cladding material

Silicon carbide (SiC)-based nuclear fission fuel rod cladding has been considered as one of the possible designs for accident tolerant fuels. It is in the form of a SiC fibre reinforced SiC matrix composite tube (SiC f -SiC m ) with monolithic SiC outer and/or inner coating layers. This study focuses on the deformation and fracture processes in this material using in situ X-ray micro-computed tomography (XCT) at room temperature (RT) and 1200 °C in an inert gas environment in a C-ring compression loading configuration. Prior to testing, local properties and residual stresses were characterised using nanoindentation and Raman spectroscopy since they can impact the mechanical behaviour of the material. The 3D strain distribution, crack formation and propagation processes including the toughening mechanisms (e.g., crack deflection, micro-cracking, crack bridging and bifurcation) are investigated in the coating and underlying composites at RT and 1200 °C. There is no particular sequence which toughening mechanism occurs first – this is very different from the conventional toughening theory in ceramic-matrix composites under uniaxial tension loading. Indeed, no evidence of fibre pull-out or fibre fracture was observed in this SiC f -SiC m nuclear cladding material in the current C-ring compression configuration. The correlation between local measurements and bulk mechanical behaviour are discussed.

3D imaging↗

Projective imaging of high-energy nuclei via coherent exclusive vector meson production in electron-nucleus collisions

One of the major goals of modern nuclear experiments is to study the distributions of gluons inside nuclei at high energy. A key measurement is the coherent exclusive vector meson (VM) production in diffractive electron-nucleus collisions, where the gluon spatial distribution inside the nucleus can be obtained through a Fourier transform of the squared nuclear momentum transfer (|t|) distribution. This research aims to overcome the two main obstacles of the |t| measurement: limited precision in measuring |t| arising from the momentum resolution of the outgoing electron and the overwhelming incoherent background. We demonstrate that by measuring the projected |t| distribution along the direction perpendicular to the electron scattering plane, the effect of the outgoing electron’s momentum resolution can be effectively mitigated, and the diffractive pattern is largely restored. Furthermore, we propose to measure the angular distribution of the VM’s decay daughters to statistically remove the incoherent background.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ion trap with in-vacuum high numerical aperture imaging for a dual-species modular quantum computer

Photonic interconnects between quantum systems will play a central role in both scalable quantum computing and quantum networking. Entanglement of remote qubits via photons has been demonstrated in many platforms; however, improving the rate of entanglement generation will be instrumental for integrating photonic links into modular quantum computers. We present an ion trap system that has the highest reported free-space photon collection efficiency for quantum networking. We use a pair of in-vacuum aspheric lenses, each with a numerical aperture of 0.8, to couple 10(1)% of the 493 nm photons emitted from a 138Ba+ ion into single-mode fibers. We also demonstrate that proximal effects of the lenses on the ion position and motion can be mitigated.

Instruments & Instrumentation↗

Generalized Optimization of High-Capacity Compressive Imaging Systems

One of the greatest challenges in applying compressive sensing (CS) signal processing techniques to electromagnetic imaging applications is designing a sensing matrix that has good reconstruction capabilities. Compressive reflector antennas (CRAs) are a class of antennas that have been shown to provide enhanced image reconstruction performance over traditional reflector antennas (TRAs) when CS techniques are employed. In this article, we present a unified CRA design method, which considers both the sensing capacity and efficiency of the antenna and can be used for both compressive imaging and multiple-input multiple-output (MIMO) communication applications. The unified design method is assessed for a CRA configuration in which dielectric scatterers are added to the surface of a TRA. The design results demonstrate the ability of the unified design method to enhance the CS reconstruction capabilities of the CRA.

42 ENGINEERING↗

Data Report: High-Resolution Microscopy Images of Sediments from Green Canyon Block 955, Gulf of Mexico

We took Leica microscopy images of sediment samples acquired at Holes H002 (4 samples) and H005 (1 sample) during the UT-GOM2-1 Expedition in Green Canyon Block 955, in the northern Gulf of Mexico. A total of 37 images were acquired. The images document a prevalence of spherical conchoidal minerals, cleavage planes typical of feldspar or mica, and black fragmented minerals which stand out from the surrounding matrix. Drilling mud intrusion is thought to contribute to a grey metallic matrix observed across multiple samples.

03 NATURAL GAS↗

Resonance-enhanced compact nonlinear acoustic source of low frequency collimated beam for imaging applications in highly attenuating media

Acoustic signal sources include acoustic resonators that include acoustic nonlinear materials. Acoustic signals at higher frequencies are mixed in the nonlinear materials to produce a lower frequency acoustic signal. Resonance provides increased efficiency in producing acoustic signals at difference frequencies corresponding to resonance frequencies. Higher frequency acoustic signals used in nonlinear mixing are preferably at frequencies corresponding to resonance frequencies as well.

Pantea, Cristian↗