TCR Postulated Accident and MHA Dose Assessment
Oak Ridge National Laboratory (ORNL) is engaged in regulatory activities to gain US Department of Energy (DOE) approval to build and operate a small high-temperature gas reactor, the Transformational Challenge Reactor (TCR). ORNL uses advanced manufacturing techniques to produce select reactor components. The TCR is unique in its mission: the reactor’s at-power operating lifetime will be less than one effective full-power day to limit the radiological source term to very low values, thus facilitating approval to operate. The primary regulatory documents governing construction and operation of the facility are NUREG-1537, “Guidelines for Preparing and Reviewing Applications for the Licensing of Non-Power Reactors” and DOE-STD-3009, “Preparation of Nonreactor Nuclear Facility Documented Safety Analysis.” Although this document is not a safety basis document, it provides a conservative indication of the magnitude of onsite and offsite radiological doses for specific scenarios, thus informing future design and regulatory activities. As required by NUREG-1537, scenarios included in this analysis are (1) a worstcase depressurized loss-of-forced-circulation accident, and (2) a maximum hypothetical accident. Details on the analysis of dose consequences with various system configurations are also provided.