Search NASA⌕ Search

SEARCH · Search NASA

Results for “high enthalpy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A Summary of the 2023 Joint High-Speed Boundary Layer Transition Workshop

A joint workshop between the Air Force Office of Scientific Research, the Office of Naval Research, and the NASA Hypersonic Technology Project was held in June 2023 on the topic of high-speed boundary-layer transition. The purpose of this workshop was to gather subject matter experts in the areas of supersonic and hypersonic boundary-layer transition in the areas of geometries of interest, computational methods, facilities and diagnostics, flight experiments, flow control, and new approaches and to discuss the current state of the art in the field. As gaps and accomplishments were identified, roadmaps were also created to guide future investments in these areas. The top recommendations are (1) to define relevant common geometries of interest that can be worked by multiple research groups; (2) improve modeling of high-enthalpy flows involving chemistry and ablation, studies of receptivity of freestream disturbances and atmospheric particulates into the boundary layer, surface feature characterization and modeling of changes to geometry; (3) design and determine viable flow control methods; and (4) move towards incorporating boundary layer transition prediction into a standard practice for design of high-speed vehicles. To execute this last recommendation successfully, investments beyond fundamental (basic and early applied) research are needed.

boundary layer transition↗

Enthalpy damping for high Mach number Euler solutions

An improvement on the enthalpy damping procedure currently in use in solving supersonic flow fields is described. A correction based on entropy values is shown to produce a very efficient scheme for simulation of high Mach number three-dimensional flows. Substantial improvements in convergence rates have been achieved by incorporating this enthalpy damping scheme in a finite-volume Runge-Kutta method for solving the Euler equations. Results obtained for blended wing-body geometries at very high Mach numbers are presented.

Moitra, Anutosh↗

Analysis of Probe Surveys Conducted in the 10-MW TP3 Arc-Jet Facility 15-Inch Nozzle Flow

Computational simulations and analysis of flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center are reported. These tests were conducted in the 10-MW TP3 facility 15-inch conical nozzle, and pitot pressure and heat flux probes are used to survey test flow downstream of the nozzle exit. Two 1.59-cm (0.625 in) diameter hemisphere probes were used: one with a stagnation-point pressure port, the other with a Gardon heat flux gage. Calibration data were also obtained using 10.16-cm iso-q and 20.32-cm flat-faced slug calorimeters. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were obtained at eight arc-heater conditions, covering wide ranges in arc current (316–1756 A) and mass flow rate (32–500 g/s, without any cold-gas injection at the arc-heater plenum) and providing assessment of the flow uniformity in the facility. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. These simulations take into account non-uniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields. Comparisons of computations with the experimental measurements are presented, showing reasonably good agreement. The probe survey data and accompanying analysis show that the test flow in the TP3 15-inch nozzle is highly non-uniform at most conditions, and the extent of flow non-uniformity depends on arc current and mass flow rate.

Arc-jets↗

Analysis of Probe Surveys Conducted in the 10-MW TP3 Arc-Jet Facility 15-Inch Nozzle Flow

Computational simulations and analysis of flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center are reported. These tests were conducted in the 10-MW TP3 facility 15-inch conical nozzle, and pitot pressure and heat flux probes are used to survey test flow downstream of the nozzle exit. Two 1.59-cm (0.625 in) diameter hemisphere probes were used: one with a stagnation-point pressure port, the other with a Gardon heat flux gage. Calibration data were also obtained using 20.32-cm flat-faced slug calorimeters. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were obtained at eight arc-heater conditions, covering wide ranges in arc current (316–1756 A) and mass flow rate (32–500 g/s, without any cold-gas injection at the arc-heater plenum) and providing assessment of the flow uniformity in the facility. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. These simulations take into account non-uniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields. Comparisons of computations with the experimental measurements are presented, showing reasonably good agreement. The probe survey data and accompanying analysis show that the test flow in the TP3 15-inch nozzle is highly non-uniform at most conditions, and the extent of flow non-uniformity depends on arc current and mass flow rate.

Arc-jets↗

The Superorbital Expansion Tube concept, experiment and analysis

In response to the need for ground testing facilities for super orbital re-entry research, a small scale facility has been set up at the University of Queensland to demonstrate the superorbital expansion tube concept. This unique device is a free piston driven, triple diaphragm, impulse shock facility which uses the enthalpy multiplication mechanism of the unsteady expansion process and the addition of a secondary shock driver to further heat the driver gas. The pilot facility has been operated to produce quasi-steady test flows in air with shock velocities in excess of 13 km/s and with a usable test flow duration of the order of 15 micro sec. an experimental condition produced in the facility with total enthalpy of 108 MJ/kg and a total pressure of 335 MPa is reported. A simple analytical flow model which accounts for non-ideal rupture of the light tertiary diaphragm and the resulting entropy increase in the test gas is discussed. It is shown that equilibrium calculations more accurately model the unsteady expansion process than calculations assuming frozen chemistry. This is because the high enthalpy flows produced in the facility can only be achieved if the chemical energy stored in the test flow during shock heating of the test gas is partially returned to the flow during the process of unsteady expansion. Measurements of heat transfer rates to a flat plate demonstrate the usability of test flow for aerothermodynamic testing and comparison of these rates with empirical calculations confirms the usable accuracy of the flow model.

Neely, A. J.↗

Radial Profiles of Plasma Electron Characteristics in a Low-Power Arcjet

Since 1960, the Arc Jet Complex at NASA Ames Research Center has been a source of long-duration, high-enthalpy flow for materials testing with application to the thermal protection of aerospace vehicle components. From their inception the facilities have played an integral role supporting many of NASA's space flight programs and numerous DoD projects. In recent years advancements in computational fluid dynamics (CFO) have made the resultant models a valuable tool for assessing and predicting performance, however, the inherent limitation of models to compensate for a dissociated, transitionally high temperature nonequilibrated flowfield have made further measurements necessary. The use of electrostatic probe diagnostics within similarly harsh plasma environments in previous studies have been met with much success. In this study, the use of a single Langmuir probe was implemented to characterize the plasma parameters of interest as they vary radially within a large volume of the plume. Classical Langmuir probe theory was applied to achieve first order estimates of the heavy particle temperature, the ratio T(sub i)/T(sub e), and the ionization fraction. As expected, both the electron temperature and electron density measurements show a dependence on radial distance from the plume centerline, with electron density profiles showing the largest dependence. This paper aims to validate and strengthen modeling work conducted at the NASA Ames Research Center by measuring the critical plasma parameters (electron temperature, electron density, and plasma potential) within the arc plume of a subscale arc jet. These parameters are intended to give physical insight into the flow characteristics while providing the necessary boundary conditions to validate full scale simulations.

Codron, Douglas↗

Partially ionized gas flow and heat transfer in the separation, reattachment, and redevelopment regions downstream of an abrupt circular channel expansion.

Heat transfer and pressure measurements obtained in the separation, reattachment, and redevelopment regions along a tube and nozzle located downstream of an abrupt channel expansion are presented for a very high enthalpy flow of argon. The ionization energy fraction extended up to 0.6 at the tube inlet just downstream of the arc heater. Reattachment resulted from the growth of an instability in the vortex sheet-like shear layer between the central jet that discharged into the tube and the reverse flow along the wall at the lower Reynolds numbers, as indicated by water flow visualization studies which were found to dynamically model the high-temperature gas flow. A reasonably good prediction of the heat transfer in the reattachment region where the highest heat transfer occurred and in the redevelopment region downstream can be made by using existing laminar boundary layer theory for a partially ionized gas. In the experiments as much as 90 per cent of the inlet energy was lost by heat transfer to the tube and the nozzle wall.

Back, L. H.↗

Thermal response and ablation characteristics of light weight ceramic ablators

An account is given of the thermal performance and ablation characteristics of the NASA-Ames Lightweight Ceramic Ablators (LCAs) in supersonic, high-enthalpy convective environments, which use low density ceramic or carbon fiber matrices as substrates for main structural support, with organic resin fillers. LCA densities are in the 0.224-1.282 g/cu cm range. In-depth temperature data have been obtained to determine thermal penetration depths and conductivity. The addition of SiC and PPMA is noted to significantly improve the ablation performance of LCAs with silica substrates. Carbon-based LCAs are the most mass-efficient at high flux levels.

Tran, Huy K.↗

Base Flow Investigation of the Apollo AS-202 Command Module

In recent years, both Europe and the US are developing hypersonic research and operational vehicles. These include (re)entry capsules (both ballistic and lifting) and lifting bodies such as ExoMars, EXPERT, ARV, CEV and IXV. The research programs are meant to enable technology and engineering capabilities to support during the next decade the development of affordable (possibly reusable) space transportation systems as well as hypersonic weapons systems for time critical targets. These programs have a broad range of goals, ranging from the qualification of thermal protection systems, the assessment of RCS performances, the development of GNC algorithms, to the full demonstration of the performance and operability of the integrated vehicles. Since the aerothermodynamic characteristics influence nearly all elements of the vehicle design, the accurate prediction of the aerothermal environment is a prerequisite for the design of efficient hypersonic systems. Significant uncertainties in the prediction of the hypersonic aerodynamic and the aerothermal loads can lead to conservative margins in the design of the vehicle including its Outer Mould Line (OML), thermal protection system, structure, and required control system robustness. The current level of aerothermal prediction uncertainties results therefore in reduced vehicle performances (e.g., sub-optimal payload to mass ratio, increased operational constraints). On the other hand, present computational capabilities enable the simulation of three dimensional flow fields with complex thermo-chemical models over complete trajectories and ease the validation of these tools by, e.g., reconstruction of detailed wind tunnel tests performed under identified and controlled conditions (flow properties and vehicle attitude in particular). These controlled conditions are typically difficult to achieve when performing in flight measurements which in turn results in large associated measurement uncertainties. Similar problems arise when attempting to rebuild measurements performed in "hot" ground facilities, where the difficulty level is increased by the addition of the free-flow characterization itself. The implementation of ever more sophisticated thermochemical models is no obvious cure to the aforementioned problems since their effect is often overwhelmed by the large measurement uncertainties incurred in both flight and ground high enthalpy facilities. Concurrent to the previous considerations, a major contributor to the overall vehicle mass of re-entry vehicles is the afterbody thermal protection system. This is due to the large acreage (equal or bigger than that of the forebody) to be protected. The present predictive capabilities for base flows are comparatively lower than those for windward flowfields and offer therefore a substantial potential for improving the design of future re-entry vehicles. To that end, it is essential to address the accuracy of high fidelity CFD tools exercised in the US and EU, which motivates a thorough investigation of the present status of hypersonic flight afterbody heating. This paper addresses the predictive capabilities of after body flow fields of re-entry vehicles investigated in the frame of the NATO/RTO - RTG-043 Task Group and is structured as follows: First, the verification of base flow topologies on the basis of available wind-tunnel results performed under controlled supersonic conditions (i.e., cold flows devoid of reactive effects) is performed. Such tests address the detailed characterization of the base flow with particular emphasis on separation/reattachment and their relation to Mach number effects. The tests have been performed on an Apollo-like re-entry capsule configuration. Second, the tools validated in the frame of the previous effort are exercised and appraised against flight-test data collected during the Apollo AS-202 re-entry.

Walpot, Louis M. G.↗

Experimental Investigation of Roughness Effects on Transition on Blunt Spherical Capsule Shapes

The present contribution reviews recent experimental results of roughness effects on boundary layer transition on capsule geometries with spherical windward geometries. Experiments in three wind tunnel facilities are considered. The ACE Tunnel of Texas AM University, USA, provided Mach 6 experiments with distributed roughness at relatively low Reynolds numbers, 2.5 · 10(exp 5) < Re(sub d) < 5 · 10(exp 5), with d denoting the capsule diameter. The observed boundary layer transition compared well with correlations based on transient growth theory, even though the roughness heights were in the order of boundary layer thickness. Larger Reynolds numbers, 1 · 10(exp 6) < Re(sub d) < 3·10(exp 6), could be assessed in the hypersonic Ludwieg tube, HLB, of TU Braunschweig, Germany. Transition is observed at rather low, subcritical roughness values in the order of 20 μm for a roughness patch placed about the geometric center of the capsule model. These experiments varied fluctuation levels of the freestream. The authors assume that the observed transitions that occur downstream of the subcritical roughness patch are due to freestream disturbances in the tunnel, which interact with small roughness heights. Additional experiments in the HLB facility with patches of larger roughness height support the relevance of transient growth theory for low-to-medium roughness heights, relative to boundary layer thickness. The effects of Reynolds numbers and total flow enthalpy on transition with isolated roughness were investigated in the HIEST facility of JAXA, Japan. Here, a model insert with roughness elements of varying height for tripping transition to turbulence was employed. The results are compared to known trip effectiveness correlations for isolated roughness. Overall, the transient growth correlation seems to represent roughness-induced transition behavior on the ACE and HLB entry capsule shapes with roughness over the entire capsule surface. These experiment are however for perfect gases. Comparable experiments on roughness induced transition in a high-enthalpy facility are still needed to confirm the validity of transient-growth correlation for vehicle design.

Radespiel, Rolf↗

CSCM methodology for slot injection cooled cavity flow design in a high enthalpic stream

The CSCM method for the compressible Navier-Stokes equations is applied to study design factors in a slot injection cooled cavity flow in the side of a 2-D wedge body in a high enthalpy free stream. The flow geometry is being designed and will be tested in an arc jet tunnel at NASA-Ames Research Center. Objectives of the design are to provide adequate thermal protection for and minimize aero-optical distortion in the path above a window located in the bottom of the cavity. Among design issues, are the geometry of and flow conditions in the expanding section of the supersonic slot injection nozzle. Here, for straight walled nozzles, two geometries are considered for the upper nozzle lip between the hot, high speed outer flow and the colder, denser cooling flow. The two lip geometries - thick, square and thin, wedge - as the result of associated widely differing base/wake flows also exhibit different and interesting viscous-inviscid flow structures near the ramp termination to the cavity. For the thin lip case, the consequences on flow quality of off design nozzle conditions relative to matching pressure with the outer flow are explored.

Bardina, Jorge↗

Thermochemically-Closed Sonic-Flow Inversion for Enthalpy and Temperature in Multispecies Arc-Jet Flows

A thermochemically-closed sonic-flow inversion framework (TSIF) is developed to infer bulk enthalpy and total temperature upstream of a choked nozzle in arc-jet flows. The formulation recasts a pressure-rise total enthalpy quantification technique as an inverse problem in characteristic-velocity c * space using measured mass flow rate, upstream total pressure, gas composition, and nozzle throat geometry as inputs. Unlike calorimetric energy-balance approaches or optical diagnostics, the method relies primarily on routinely measured facility quantities combined with explicit thermochemical closure. Thermochemical states are obtained using NASA’s open-source Chemical Equilibrium with Applications (CEA) code, enabling construction of a chemistry-consistent relation between characteristic velocity, total enthalpy, and total temperature under equilibrium or frozen assumptions. A discharge coefficient is self-calibrated using cold-flow (arc-off) operation data and applied to hot-flow (arc-on) measurements, enabling upstream losses to be accounted for without empirical correlations. The framework is applied to air, N 2 , and CO 2 –N 2 arc-jet flows and demonstrates expected trends for the inferred thermochemical states as function of arc power, specific energy input, mass-flow, heater configuration, and test gas. In the air limit, under equilibrium assumptions, the method recovers the classical high-enthalpy asymptotic correlation of Winovich with a mean residual of 4.4%, demonstrating compatibility with established sonic-flow scaling, while extending applicability to arbitrary multi-species mixtures and non-equilibrium chemistry. The framework provides a mixture-flexible methodology for determining bulk thermochemical states in modern arc-jet environments using routine facility pressure, mass-flow, gas-composition, and nozzle-geometry information together with a cold-flow calibration.

stagnation heat flux↗

Thermochemically-Closed Sonic-Flow Inversion for Enthalpy and Temperature in Multispecies Arc-Jet Flows

A thermochemically-closed sonic-flow inversion framework (TSIF) is developed to infer bulk enthalpy and total temperature upstream of a choked nozzle in arc-jet flows. The formulation recasts a pressure-rise total enthalpy quantification technique as an inverse problem in characteristic-velocity c * space using measured mass flow rate, upstream total pressure, gas composition, and nozzle throat geometry as inputs. Unlike calorimetric energy-balance approaches or optical diagnostics, the method relies primarily on routinely measured facility quantities combined with explicit thermochemical closure. Thermochemical states are obtained using NASA’s open-source Chemical Equilibrium with Applications (CEA) code, enabling construction of a chemistry-consistent relation between characteristic velocity, total enthalpy, and total temperature under equilibrium or frozen assumptions. A discharge coefficient is self-calibrated using cold-flow (arc-off) operation data and applied to hot-flow (arc-on) measurements, enabling upstream losses to be accounted for without empirical correlations. The framework is applied to air, N 2 , and CO 2 –N 2 arc-jet flows and demonstrates expected trends for the inferred thermochemical states as function of arc power, specific energy input, mass-flow, heater configuration, and test gas. In the air limit, under equilibrium assumptions, the method recovers the classical high-enthalpy asymptotic correlation of Winovich with a mean residual of 4.4%, demonstrating compatibility with established sonic-flow scaling, while extending applicability to arbitrary multi-species mixtures and non-equilibrium chemistry. The framework provides a mixture-flexible methodology for determining bulk thermochemical states in modern arc-jet environments using routine facility pressure, mass-flow, gas-composition, and nozzle-geometry information together with a cold-flow calibration.

inviscid theory↗

Scramjet sidewall burning: Preliminary shock tunnel results

Experiments performed with a two dimensional model scramjet with particular emphasis on the effect of fuel injection from a wall are reported. Air low with a nominal Mach number of 3.5 and varied enthalpies was produced. It was found that neither hydrogen injection angle nor combustor divergence angle had any appreciable effect on thrust values while increased combustor length appeared to increase thrust levels. Specific impulse was observed to peak when hydrogen was injected at an equivalence ratio of about 2. Lowering the Mach number of the injected hydrogen at low equivalence ratios, less than 4, appeared to benefit specific impulse while hydrogen Mach number had little effect at higher equivalence ratios. When a 1:1 mixture by volume of nitrogen and oxygen is used instead of air as a test gas, it is found that hydrogen combustion is enhanced but only at high enthalpies.

Morgan, R. G.↗

Measurement of material recession and shock standoff in plasma windtunnel using neural nets

Arcjets are plasma wind tunnels used to test the performance of heatshield materials for spacecraft atmospheric entry. These facilities present an extremely harsh flow environment with heat fluxes up to 10^9 W/m^2 for up to 30 minutes. The plasma is low-temperature (~1 eV) but high pressure (> 10 kPa) creating high-enthalpy supersonic flows similar to atmospheric entry conditions. Typically, material samples are measured before and after a test to characterize the total recession. However, this does not capture time-dependent effects such as material expansion and non-linear recession. This work will present new analysis of arcjet test videos which measure both the time-dependent 2D recession of the material samples and the shock standoff distance. New results showing non-linear material erosion rates will be highlighted. The material and shock edges are extracted from the videos by training and applying a convolutional neural network. Due to the consistent camera settings, the machine learning model achieves high accuracy (~99%) on new data with only a small number of training frames (~80). The new results will be discussed in the context of temperature dependent plasma-surface interaction.

Magnus A Haw↗

Measurement of Material Recession and Shock Standoff in Plasma Windtunnel using Neural Nets

Arcjets are plasma wind tunnels used to test the performance of heatshield materials for spacecraft atmospheric entry. These facilities present an extremely harsh flow environment with heat fluxes up to 109 W/m2 for up to 30 minutes. The plasma is low-temperature (∼1 eV) but high pressure (> 10 kPa) creating high-enthalpy supersonic flows similar to atmospheric entry conditions. Typically, material samples are measured before and after a test to characterize the total recession. However, this does not capture time-dependent effects such as material expansion and non-linear recession. This work will present new analysis of arcjet test videos which measure both the time-dependent 2D recession of the material samples and the shock standoff distance. The results show non-linear time-dependent effects are present for some conditions. The material and shock edges are extracted from the videos by training and applying a convolutional neural network. Due to the consistent camera settings, the machine learning model achieves high accuracy (± 2 px) relative to manually segmented images with only a small number of training frames (80).

Neural network↗

Flow Characterization Studies of the 10-MW TP3 Arc-Jet Facility: Probe Sweeps

This paper reports computational simulations and analysis in support of calibration and flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted in the NASA Ames 10-MW TP3 facility using flat-faced stagnation calorimeters at six conditions corresponding to the steps of a simulated flight heating profile. Data were obtained using a conical nozzle test configuration in which the models were placed in a free jet downstream of the nozzle. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were also performed at these arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. Two different sets of pitot pressure and heat probes were used: 9.1-mm sphere-cone probes (nose radius of 4.57 mm or 0.18 in) with null-point heat flux gages, and 15.9-mm (0.625 in) diameter hemisphere probes with Gardon gages. The probe survey data clearly show that the test flow in the TP3 facility is not uniform at most conditions (not even axisymmetric at some conditions), and the extent of non-uniformity is highly dependent on various arc-jet parameters such as arc current, mass flow rate, and the amount of cold-gas injection at the arc-heater plenum. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. Comparisons of computations with the experimental measurements show reasonably good agreement except at the extreme low pressure conditions of the facility envelope.

Goekcen, Tahir↗

Flow Characterization Studies of the 10-MW TP3 Arc-Jet Facility: Probe Sweeps

This paper reports computational simulations and analysis in support of calibration and flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted in the NASA Ames 10-MW TP3 facility using flat-faced stagnation calorimeters at six conditions corresponding to the steps of a simulated flight heating profile. Data were obtained using a conical nozzle test configuration in which the models were placed in a free jet downstream of the nozzle. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were also performed at these arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. Two different sets of pitot pressure and heat probes were used: 9.1-mm sphere-cone probes (nose radius of 4.57 mm or 0.18 in) with null-point heat flux gages, and 15.9-mm (0.625 in) diameter hemisphere probes with Gardon gages. The probe survey data clearly show that the test flow in the TP3 facility is not uniform at most conditions (not even axisymmetric at some conditions), and the extent of non-uniformity is highly dependent on various arc-jet parameters such as arc current, mass flow rate, and the amount of cold-gas injection at the arc-heater plenum. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. Comparisons of computations with the experimental measurements show reasonably good agreement except at the extreme low pressure conditions of the facility envelope.

CFD↗