At least 127 records · Page 7

Microphone Corrections for Accurate In-Flow Acoustic Measurements at High Frequency

Acoustic analysis of aircraft components through small-scale experiments in wind tunnels requires in-flow acoustic measurements at high frequencies. This high frequency information is shifted to lower frequencies during the geometric scaling process. As a result, models of scale one tenth and smaller require frequency information of up to at least 100 kHz to resolve the midpoint of the full-scale equivalent audible range. Farfield acoustic measurements of frequencies higher than 100 kHz are prohibitively difficult to make due to the physical limitations of atmospheric propagation over large distances and the delicacy of the required instruments. Even measurements up to 100 kHz require special corrections and calibration procedures to maintain sufficient accuracy. In-flow microphone measurements at high frequencies require additional consideration due to the presence of the aerodynamic microphone forebody which protects the microphone diaphragm from flow impingement. The screen located at the forebody surface attenuates the high frequency acoustic waves and must be accounted for. The purpose of this paper is to present procedures for calibrating and correcting high frequency acoustic measurements to retain high accuracy. Specifically, this paper gives calibration procedures and examples of typical data for calibrating or correcting for five physical effects. These effects include the frequency response of the entire acoustic data acquisition system, intrusion of the microphone into the acoustic field, forebody screen attenuation, directionality of microphone forebody response and atmospheric absorption.

Allen, Christopher S.↗

Development of the NASA High-Altitude Imaging Wind and Rain Airborne Profiler

The scope of this paper is the development and recent field deployments of the High-Altitude Imaging Wind and Rain Airborne Profiler (HIWRAP), which was funded under the NASA Instrument Incubator Program (IIP) [1]. HIWRAP is a dual-frequency (Ka- and Ku-band), dual-beam (300 and 400 incidence angles), conical scanning, Doppler radar system designed for operation on the NASA high-altitude (65,000 ft) Global Hawk Unmanned Aerial System (UAS). It utilizes solid state transmitters along with a novel pulse compression scheme that results in a system with compact size, light weight, less power consumption, and low cost compared to radars currently in use for precipitation and Doppler wind measurements. By combining measurements at Ku- and Ka-band, HIWRAP is able to image winds through measuring volume backscattering from clouds and precipitation. In addition, HIWRAP is also capable of measuring surface winds in an approach similar to SeaWinds on QuikScat. To this end, HIWRAP hardware and software development has been completed. It was installed on the NASA WB57 for instrument test flights in March, 2010 and then deployed on the NASA Global Hawk for supporting the Genesis and Rapid Intensification Processes (GRIP) field campaign in August-September, 2010. This paper describes the scientific motivations of the development of HIWRAP as well as system hardware, aircraft integration and flight missions. Preliminary data from GRIP science flights is also presented.

Li, Lihua↗

Tropical rainfall measuring mission (TRMM)

By measuring rainfall in the tropics, the Tropical Rainfall Measuring Mission (TRMM) will make possible the understanding of the heat engine that drives the global weather. The TRMM mission parameters are given, and the spacecraft is described. The instruments are examined, including the precipitation radar, TRMM microwave radiometer, and Advanced Very High Frequency Radiometer. The mission life is addressed, including atmospheric data, fuel consumption, and life extension methods. The spacecraft interfaces, payload configuration, and deployment sequence are considered. The subsystems are described, including propulsion, power, command, data handling, and tracking. A Japanese Experimental Data Relay Tracking Satellite experimental package working with TRMM is briefly addressed.

Keating, Thomas↗

Application of the Hilbert-Huang Transform to the Search for Gravitational Waves

We present the application of a novel method of time-series analysis, the Hilbert-Huang Transform, to the search for gravitational waves. This algorithm is adaptive and does not impose a basis set on the data, and thus the time-frequency decomposition it provides is not limited by time-frequency uncertainty spreading. Because of its high time-frequency resolution it has important applications to both signal detection and instrumental characterization. Applications to the data analysis of the ground and space based gravitational wave detectors, LIGO and LISA, are described.

Camp, Jordan B.↗

Dual-Polarization, Sideband-Separating, Balanced Receiver for 1.5 THz

A proposed heterodyne receiver would be capable of detecting electromagnetic radiation in both of two orthogonal linear polarizations, separating sidebands, and providing balanced outputs in a frequency band centered at 1.5 THz with a fractional bandwidth greater than 40 percent. Dual polarization, sideband-separating, and balanced-output receivers are well-known and have been used extensively at frequencies up to about 100 GHz; and there was an earlier proposal for such a receiver for frequencies up to 900 GHz. However, the present proposal represents the first realistic design concept for such a receiver capable of operating above 1 THz. The proposed receiver is intended to be a prototype of mass-producible receiver units, operating at frequencies up to 6 THz, that would be incorporated into highly sensitive heterodyne array instruments to be used in astronomical spectroscopic and imaging studies.

Chattopadhyay, Goutman↗

Crane-Load Contact Sensor

An electronic instrument has been developed as a prototype of a portable crane-load contact sensor. Such a sensor could be helpful in an application in which the load rests on a base in a horizontal position determined by vertical alignment pins (see Figure 1). If the crane is not positioned to lift the load precisely vertically, then the load can be expected to swing once it has been lifted clear of the pins. If the load is especially heavy, large, and/or fragile, it could hurt workers and/or damage itself and nearby objects. By indicating whether the load remains in contact with the pins when it has been lifted a fraction of the length of the pins, the crane-load contact sensor helps the crane operator determine whether it is safe to lift the load clear of the pins: If there is contact, then the load is resting against the sides of the pins and, hence, it may not be safe to lift; if contact is occasionally broken, then the load is probably not resting against the pins, so it should be safe to lift. It is assumed that the load and base, or at least the pins and the surfaces of the alignment holes in the load, are electrically conductive, so the instrument can use electrical contact to indicate mechanical contact. However, DC resistance cannot be used as an indicator of contact for the following reasons: The load and the base are both electrically grounded through cables (the load is grounded through the lifting cable of the crane) to prevent discharge of static electricity. In other words, the DC resistance between the load and the pins is always low, as though they were always in direct contact. Therefore, instead of DC resistance, the instrument utilizes the AC electrical impedance between the pins and the load. The signal frequency used in the measurement is high enough (.1 MHz) that the impedance contributed by the cables and the electrical ground network of the building in which the crane and the base are situated is significantly greater than the contact impedance between the pins and the load. The instrument includes a signal generator and voltage-measuring circuitry, and is connected to the load and the base as shown in Figure 2. The output of the signal generator (typically having amplitude of the order of a volt) is applied to the load via a 50-resistor, and the voltage between the load and the pins is measured. When the load and the pins are not in contact, the impedance between them is relatively high, causing the measured voltage to exceed a threshold value. When the load and the pins are in contact, the impedance between them falls to a much lower value, causing the voltage to fall below the threshold value. The voltage-measuring circuitry turns on a red light-emitting diode (LED) to indicate the lower-voltage/ contact condition. Whenever the contact has been broken and the non-contact/higher-voltage condition has lasted for more than 2 ms, the voltage-measuring circuitry indicates this condition by blinking a green LED.

Youngquist, Robert↗

Operational Parameters, Considerations, and Design Decisions for Resource-Constrained Ion Trap Mass Spectrometers

Mass spectrometers are increasingly finding applications in new and unique areas, often in situations where key operational resources (i.e. power, weight and size) are limited. One such example is the Mars Organic Molecule Analyzer (MOMA). This instrument is a joint venture between NASA and the European Space Agency (ESA) to develop an ion trap mass spectrometer for chemical analysis on Mars. The constraints on such an instrument are significant as are the performance requirements. While the ideal operating parameters for an ion trap are generally well characterized, methods to maintain analytical performance with limited power and system weight need to be investigated and tested. Methods Experiments have been performed on two custom ion trap mass spectrometers developed as prototypes for the MOMA instrument. This hardware consists of quadrupole ion trap electrodes that are 70% the size of common commercial instrumentation. The trapping RF voltage is created with a custom tank circuit that can be tuned over a range of RF frequencies and is driven using laboratory supplies and amplifiers. The entire instrument is controlled with custom Lab VIEW software that allows a high degree of flexibility in the definition of the scan function defining the ion trap experiment. Ions are typically generated via an internal electron ionization source, however, a laser desorption source is also in development for analysis of larger intact molecules. Preliminary Data The main goals in this work have been to reduce the power required to generate the radio frequency trapping field used in an ion trap mass spectrometer. Generally minimizing the power will also reduce the volume and mass of the electronics to support the instrument. In order to achieve optimum performance, commercial instruments typically utilize RF frequencies in the 1 MHz range. Without much concern for power usage, they simply generate the voltage required to access the mass range of interest. In order to reduce the required RF voltage (and power), operation of the ion trap at lower RF frequencies has been investigated. Surprisingly, the performance of the instrument has only been slightly degraded at RF frequencies all the way down to 500 kHz. Mass resolution is relatively stable to this point and depending on the resonant ejection point used, the peak intensity is also quite stable. To date only masses up to m/z 200 have been fully investigated, however, additional studies are planned to verify the performance with higher mass ions. The lower frequency and voltage should reduce the pseudo potential well depth, eventually affecting the trapping efficiency of the instrument -- effect that could manifest itself in significantly limiting the mass range of trapped ions. Other methods to reduce the RF power while maintaining analytical performance are also under investigation. This includes ion ejection at lower q(sub z) values to access a given mass with a lower RF voltage. The loss of mass resolution at lower q(sub eject) points has been measured and current work is underway to leverage scan speed and the use of non-linear resonances in order to counter this trend. The overall trap performance under this range of operating conditions will be presented with a goal of identifying what trade-offs are acceptable.

Danell, Ryan M.↗

High-resolution spectrograms of ion acoustic waves in the solar wind

High-resolution, frequency-time spectrograms of ion acoustic waves in the solar wind obtained by the Voyager spacecraft at distances of up to 1.7 AU are examined. The plasma wave instrument on board the Voyager spacecraft used to acquire the spectra employs an electric dipole antenna with a 16-channel step frequency receiver and a high-bit-rate waveform receiver to detect and measure the electric field of plasma waves. Voyager spectrograms show that the ion acoustic waves consist of narrowband, rapidly varying bursts, lasting a few seconds or less, usually in the range between the plasma ion and electron frequencies. Spectrograms taken at 1.7 AU are shown to be essentially identical to similar measurements taken upstream of the earth's magnetosphere, which are produced by suprathermal protons streaming into the solar wind from the bow shock, and to those taken upstream of interplanetary shocks.

Kurth, W. S.↗

Intercomparison between Nimbus-7 cirrus cloud data and ERB measurements

Nimbus-7 and Earth Radiation Budget (ERB) data were compared with the quantity of high, thin cirrus clouds over a 6 yr period. Three separate data analysis techniques are described which were used to derive cloud cover and total upwelling radiance values from the satellite data. Zonal average cirrus clouds amounts are compared with surface observations and SAGE satellite data, and comparisons are made between the cloud amount estimates made with ERB data and data from other Nimbus-7 instruments. All Nimbus-7 instrumental data indicated cloud amounts and frequency of occurrence patterns which were commensurate with surface observations, except in high latitude zones.

Yeh, H. Y. M.↗

RXTE Observation of Cygnus X-1: TIming Analysis - Report 2

We present timing analysis for a Rossi X-ray Timing Explorer (RXTE) observation of Cygnus X-1 in its hard/low state. This was the first RXTE observation of Cyg X-1 taken after it transited back to this state from its soft/high state. RXTE's large effective area, superior timing capabilities, and ability to obtain long, uninterrupted observations have allowed us to obtain measurements of the power spectral density (PSD), coherence function, and Fourier time lags to a decade lower in frequency and half a decade higher in frequency than typically was achieved with previous instruments. Notable aspects of our observations include a weak 0.005 Hz feature in the PSD coincident with a coherence recovery; a 'hardening' of the high-frequency PSD with increasing energy; a broad frequency range measurement of the coherence function, revealing rollovers from unity coherence at both low and high frequency; and an accurate determination of the Fourier time lags over two and a half decades in frequency. As has been noted in previous similar observations, the time delay is approximately proportional to f(exp -0.7), and at a fixed Fourier frequency the time delay of the hard X-rays compared to the softest energy channel tends to increase logarithmically with energy. Curiously, the 0.01-0.2 Hz coherence between the highest and lowest energy bands is actually slightly greater than the coherence between the second highest and lowest energy bands. We carefully describe all of the analysis techniques used in this paper, and we make comparisons of the data to general theoretical expectations. In a companion paper, we make specific comparisons to a Compton corona model that we have successfully used to describe the energy spectral data from this observation.

Nowak, Michael A.↗

Instrumentation for measuring low-level currents/voltages

Instrumentation consists of high-output resistance voltage measuring amplifier (electrometer) and current-to-frequency converter (current digitizer) coupled to set of timers and counters. Digital display of time-averaged signals with amplitudes varying over 11 decades is possible.

Richmond, R. G.↗

The N.A.C.A. Optical Engine Indicator

An optically recording engine-pressure indicator of simple and rugged construction has been developed for use in high-pressure and high temperature combustion research. This instrument is of the diaphragm type and has a natural frequency of about 10,000 cycles per second.

Tozier, Robert E↗

Acoustic Treatment Design Scaling Methods: Analytical and Experimental Data Correlation - Volume 5

The primary purpose of the study presented in this volume is to present the results and data analysis of in-duct transmission loss measurements. Transmission loss testing was performed on full-scale, 1/2-scale, and 115-scale treatment panel samples. The objective of the study was to compare predicted and measured transmission loss for full-scale and subscale panels in an attempt to evaluate the variations in suppression between full- and subscale panels which were ostensibly of equivalent design. Generally, the results indicated an unsatisfactory agreement between measurement and prediction, even for full-scale. This was attributable to difficulties encountered in obtaining sufficiently accurate test results, even with extraordinary care in calibrating the instrumentation and performing the test. Test difficulties precluded the ability to make measurements at frequencies high enough to be representative of subscale liners. It is concluded that transmission loss measurements without ducts and data acquisition facilities specifically designed to operate with the precision and complexity required for high subscale frequency ranges are inadequate for evaluation of subscale treatment effects.

Chien, W. E.↗

MgB2 Thin-Film Bolometer for Applications in Far-Infrared Instruments on Future Planetary Missions

A SiN membrane based MgB2 thin-film bolometer, with a non-optimized absorber, has been fabricated that shows an electrical noise equivalent power of 256 fW/square root Hz operating at 30 Hz in the 8.5 - 12.35 micron spectral bandpass. This value corresponds to an electrical specific detectivity of 7.6 x 10(exp 10) cm square root Hz/W. The bolometer shows a measured blackbody (optical) specific detectivity of 8.8 x 10(exp 9) cm square root Hz/W, with a responsivity of 701.5 kV/W and a first-order time constant of 5.2 ms. It is predicted that with the inclusion of a gold black absorber that a blackbody specific detectivity of 6.4 x 10(exp 10) cm/square root Hz/W at an operational frequency of 10 Hz, can be realized for integration into future planetary exploration instrumentation where high sensitivity is required in the 17 - 250 micron spectral wavelength range.

Lakew, B.↗

The Polar Plasma Wave Instrument

The Plasma Wave Instrument on the Polar spacecraft is designed to provide measurements of plasma waves in the Earth's polar regions over the frequency range from 0.1 Hz to 800 kHz. Three orthogonal electric dipole antennas are used to detect electric fields, two in the spin plane and one aligned along the spacecraft spin axis. A magnetic loop antenna and a triaxial magnetic search coil antenna are used to detect magnetic fields. Signals from these antennas are processed by five receiver systems: a wideband receiver, a high-frequency waveform receiver, a low-frequency waveform receiver, two multichannel analyzers; and a pair of sweep frequency receivers. Compared to previous plasma wave instruments, the Polar plasma wave instrument has several new capabilities. These include (1) an expanded frequency range to improve coverage of both low- and high-frequency wave phenomena, (2) the ability to simultaneously capture signals from six orthogonal electric and magnetic field sensors, and (3) a digital wideband receiver with up to 8-bit resolution and sample rates as high as 249k samples s(exp -1).

Gurnett, D. A.↗

Application of OMI, SCIAMACHY and GOME-2 Satellite SO2 Retrievals for Detection of Large Emission Sources

Retrievals of sulfur dioxide (SO2) from space-based spectrometers are in a relatively early stage of development. Factors such as interference between ozone and SO2 in the retrieval algorithms often lead to errors in the retrieved values. Measurements from the Ozone Monitoring Instrument (OMI), Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY), and Global Ozone Monitoring Experiment-2 (GOME-2) satellite sensors, averaged over a period of several years, were used to identify locations with elevated SO2 values and estimate their emission levels. About 30 such locations, detectable by all three sensors and linked to volcanic and anthropogenic sources, were found after applying low and high spatial frequency filtration designed to reduce noise and bias and to enhance weak signals to SO2 data from each instrument. Quantitatively, the mean amount of SO2 in the vicinity of the sources, estimated from the three instruments, is in general agreement. However, its better spatial resolution makes it possible for OMI to detect smaller sources and with additional detail as compared to the other two instruments. Over some regions of China, SCIAMACHY and GOME-2 data show mean SO2 values that are almost 1.5 times higher than those from OMI, but the suggested spatial filtration technique largely reconciles these differences.

SO2 retrievals↗

The WISP/HF system for Spacelab

The high frequency part of the waves in space plasmas system, WISP/HF, is a flexible shuttle Spacelab instrument for transmitting, receiving, and processing signals in the 0.3 to 30 MHz range. It permits a wide range of plasma wave experiments in the ionosphere including studies of the transmitting antenna, fundamentals of electromagnetic (EM) and electrostatic (ES) waves in magnetoplasmas, instabilities and nonlinearities, and remote sounding of ionospheric structure. Collaborative investigations involving other WISP equipment (e.g., antenna and propagation studies with the WISP/VLF system) or other Spacelab facilities (e.g., beam plasma interactions using charged particle guns) are envisaged. A few specific examples illustrate the relevance of WISP/HF to current scientific interest. The overall goal is to help build a comprehensive understanding of plasmaspheric wave physics through group studies.

James, H. G.↗

Comet nucleus gamma-ray spectrometer penetrator - An in situ nucleus composition experiment

An engineering design study of a comet nucleus penetrator system for in situ determinations of comet composition is presented. The system is designed for participation in the Comet Rendezvous/Asteroid Flyby mission to comet Kopff in 1996. The instrumentation payload of the penetrator system will include a passive gamma-ray spectrometer; a high frequency response accelerometer for measurements of the impact deceleration profile of the system as it penetrates to the nucleus of the comet; and several thermocouples mounted along the length of the penetrator to measure temperature and temperature gradients. The mechanical, electrical and thermal interfaces between the penetrator and the Mariner Mark II spacecraft are described. A series of line drawings is provided which illustrates the proposed configuration of the system.

Swenson, B. L.↗