Search NASA⌕ Search

SEARCH · Search NASA

Results for “high precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

High-precision laser distance measurement in support of lunar laser ranging at Haleakala, Maui, 1976-1977

The Hawaii Institute of Geophysics has implemented a comprehensive geodetic-geophysical support program to monitor local and regional crustal deformation on the island of Maui. Presented are the actual laser-measured line lengths and new coordinate computations of the line terminals, and the internal consistency of the measured line lengths is discussed. Several spacial chord lengths have been reduced to a Mercator plane, and conditioned adjustments on that plane have been made.

Berg, E.↗

High-precision infrared sky survey at wavelength 2.7 microns

Preliminary results of an infrared survey of the equatorial sky zone (declinations 10 S to 10 N) with U.S. Air Force satellite sensors show that positions of previously unknown infrared sources are measured with an rms accuracy of 4 arc seconds, which is six times better than the best previous infrared survey. The search area per source for further study is thus 36 times smaller, so that identification of the infrared sources with optical objects in catalogs and sky photographs is facilitated, as is reacquisition of the sources with ground-based infrared telescopes. The survey extends the content of near-infrared source catalogs to lower flux densities and adds information at a wavelength not observable from the ground. Objects found in the survey include cool giants and supergiants, long-period and semi-regular variable stars, and sources identified with faint red stars visible on the Palomar Observatory Sky Survey.

Sweeney, L. H.↗

Assessment of atmospheric height uncertainties for high precision satellite altimeter missions to monitor ocean currents

The influence of the atmosphere on nadir directed signal associated with satellite altimeters are examined. Frequencies at 6, 13.5, and 35 GHz are selected so as to provide a parameter study. Uncertainties are summarized in both existing and proposed techniques which establish ionospheric and tropospheric height corrections. The error summary thus gives values describing the best you can do in height resolution (as dictated by atmospheric parameters) for a satellite borne altimeter system. The results presented reflect data gleaned from the literature, at large, as well as from the existing body of published literature associated with the Seasat A Altimeter Experiment. Specifically considered are: (1) the effects of precipitation on altimeter signals, (2) range errors due to refractive index variations in both the clear atmosphere (convective and nonconvective) and clouds, and (3) range errors introduced by the ionosphere. A preliminary analysis is pursued establishing the feasibility of incorporating rain rate range gates in a future satellite-borne altimeter system.

Goldhirsh, J.↗

Advances in the stability of high precision crystal resonators

Advances in technology directed toward minimizing the temporal changes in frequency of crystal resonators are described. Specific emphasis is placed on reducing their susceptibility to temperature, acceleration, and other environmental effects.

Ballato, A.↗

Gamma ray bursts: A review of recent high-precision measurements

Recent measurements and discoveries in gamma ray bursts and transients are reviewed including observations of the red shifted annihilation line in two kinds of slow transients (in 'classical' gamma ray bursts and in the unique 1979 March 5th event); of red shifted nuclear lines in a slow transient and in one gamma ray burst; and of the positions of precise source locations of gamma ray bursts and of the March 5th event, within the supernova remnant N49 in the Large Magellanic Cloud.

Cline, T. L.↗

High precision attitude determination for Magsat

A two phase approach to attitude determination software development is introduced. The prelaunch planning and software activities connected with the development and testing of the baseline system for processing nominal attitude data for MAGSAT are described and postlaunch analysis and modifications are outlined. Attitude data processing began 5 months after launch so that postlaunch anomalies could be accounted for. Another advantage of the two phase approach is that costs are reduced because the system is not burdened with software dealing with all possible contingencies. A definitive, continuous, time history of the three axis attitude of the spacecraft was generated to a precision of 20 arc sec (one standard deviation), in each axis. Sensor alignment determinations were done continuously because of the deletrious effects of changing alignments on attitude precision.

Abshire, G.↗

Developments in high-precision gamma-ray burst source studies

The source location data analyzed by the first and second interplanetary gamma ray burst spacecraft networks are reviewed. The possibilities of additional networks and of related studies in other disciplines, and the prospects for real time optical transient observations and for the definition of gamma ray burst sources by optical transient astronomy are also reviewed.

Cline, T. L.↗

Developments in high-precision gamma-ray burst source studies

The source location data analyzed by the first and second interplanetary gamma ray burst spacecraft networks are reviewed. The possibilities of additional networks and of related studies in other disciplines, and the prospects for real time optical transient observations and for the definition of gamma ray burst sources by optical transient astronomy are also reviewed. Previously announced in STAR as N82-31290

Cline, T. L.↗

Characteristics and capacities of the NASA Lewis Research Center high precision 6.7- by 6.7-m planar near-field scanner

A very precise 6.7- by 6.7-m planar near-field scanner has recently become operational at the NASA Lewis Research Center. The scanner acquires amplitude and phase data at discrete points over a vertical rectangular grid. During the design phase for this scanner, special emphasis was given to the dimensional stability of the structures and the ease of adjustment of the rails that determine the accuracy of the scan plane. A laser measurement system is used for rail alignment and probe positioning. This has resulted in very repeatable horizontal and vertical motion of the probe cart and hence precise positioning in the plane described by the probe tip. The resulting accuracy will support near-field measurements at 60 GHz without corrections. Subsystem design including laser, electronic and mechanical and their performance is described. Summary data are presented on the scan plane flatness and environmental temperature stability. Representative near-field data and calculated far-field test results are presented. Prospective scanner improvements to increase test capability are also discussed.

Sharp, G. R.↗

High precision active nutation control for a flexible momentum biased spacecraft

The controller design for the Solar Dynamics Observatory (SDO) is presented. SDO is a momentum biased spacecraft with three flexible appendages. Its primary scientific instrument, the solar oscillations imager (SOI), is rigidly attached to the spacecraft bus and has arc-second pointing requirements. Meeting these requirements necessitates the use of an active nutation controller (ANC) which is here mechanized with a small reaction wheel oriented along a bus transverse axis. The ANC does its job by orchestrating the transfer of angular momentum out of the bus transverse axes and into the momentum wheel. A simulation study verifies that the controller provides quick, stable, and accurate response.

Laskin, R. A.↗

High Precision Measurement of Stellar Radial Velocity Variations

A prototype instrument for measurement of stellar radial velocity variations to a precision of a few meters per second is discussed. The instrument will be used to study low amplitude stellar non-radial oscillations, to search for binary systems with large mass ratios, and ultimately to search for extrasolar planetary systems. The instrument uses a stable Fabry-Perot etalon, in reflection, to impose a set of fixed reference absorption lines on the stellar spectrum before it enters the coude spectrograph of the McDonald Observatory 2.7-m telescope. The spectrum is recorded on the Octicon detector, which consists of eight Reticon arrays placed end to end. Radial velocity variations of the star are detected by measuring the shift of the stellar lines with respect the artificial Fabry-Perot lines, and correcting for the known motions in the solar system.

Cochran, W. D.↗

GPS navigation experiment using high precision GPS timing receivers

Global Positioning System (GPS) Time Transfer receivers were developed by the Naval Research Laboratory (NRL) to provide synchronization for the NASA Global Laser Tracking Network (GLTN). The capabilities of the receiver are being expanded mainly through software modification to: Demonstrate the position location capabilities of a single channel receiver unsign the GPS C/A code; and Demonstrate the time/navigation capability of the receiver onboard a moving platform, by sequential tracking of GPS satellites.

Buisson, J. A.↗

High precision GPS orbit determination using March 1985 demonstration data

Preliminary orbit determination for satellites in the U.S. Department of Defense's Global Positioning System has been performed using GPS carrier phase data collected in March-April 1985 at 10 sites in the continental United States. The data were analyzed using a new data processing software package called GIPSY (GPS Inferred Positioning SYstem) and with existing covariance analysis software. Data from one day have been processed with average formal position errors of 1.4 to 3.6 meters. The true errors are probably somewhat larger. Covariance results are presented which suggest that the orbits can be obtained with formal errors under 2 meters after certain software issues are resolved.

Bertiger, W.↗

Method of high-precision microsampled blood and plasma mass densitometry

The reliability of the mechanical oscillator technique for blood and plasma density measurements on samples of volumes less than 0.1 ml is examined, and a precision of 0.001 g/l is found if plasma-isodensic heparin solution and siliconized densitometers are employed. Sources of measurement errors in the density determinations include storage of plasma samples, inhomogeneity of blood samples, and density reading before adequate temperature equilibration. In tests of plasma sample storage, the best reproducibility was obtained with samples kept at 4 C. Linear correlations were found between plasma density and plasma protein concentration, blood density and blood hemoglobin concentration, and erythrocyte density and MCHC.

Hinghofer-Szalkay, H.↗

High precision low resolution spectrophotometry of Comets Giacobini-Zinner and Halley

Optical window (300 to 1000 nm) observations were made of Comet Halley during 12 to 14 Mar. 1986 by a scanning spectrometer. The results provide accurate spectrophotometric measurements of the principal molecular bands from the 308 nm OH through the 918 nm CN emissions. The observations can be used to tie space derived ultraviolet and groundbased infrared observations to the optical observations and to one another. Additional observations were made of comet Giacobini-Zinner on 30 September 1985 of the same OH band and the 388 nm band of CN. The Swan band sequence ratios are used to test the best models of C2, with different ratios favoring different models, calling into question the assumptions of these very complete models.

Odell, C. R.↗

A high-precision ab initio determination of the equilibrium geometry and force field of HOC(+)

The results of an ab initio molecular orbital investigation of the isoformyl cation, HOC(+), shape are reported. The effects of expanding the basis set to near the Hartree-Fock limit and of electron correlation were examined, and the results indicate that near the Hartree-Fock limit the HOC(+) is linear. An analytic potential function is presented, from which the calculated rotational energies are only 0.03 percent different from the experimental values. This represents a nearly two orders of magnitude reduction in error from earlier work.

Defrees, D. J.↗