Search NASA⌕ Search

SEARCH · Search NASA

Results for “high precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

An R Shiny graphical user interface for analyzing, visualizing, and interpreting high precision mass spectrometric data

There is currently a lack of software that meets the needs for the analysis of raw data produced by modern isotope ratio mass spectrometers for both R&D and routine use at SRNL and other US national labs • Needs to accommodate multiple isotope systems, instruments, and manufacturers • Include modern statistical methods and handling/visualization of uncertainty • Flexible software with transparent (no “black box”) and reproducible methods • This project is inspired by existing discipline-specific data analysis software (e.g., Tripoli1 , ET_Redux2 , IsoplotR3) used in the geochemical community • Our goal is to build an open source data analysis software package that focuses on flexibility, transparency, and reproducibility

Labone, Elizabeth↗

Comments on the paper “Eliminating beam-induced depolarizing effects in the hydrogen jet target for high-precision proton beam polarimetry at the Electron-Ion Collider” (Part I)

A critical review of the methodology used in F. Rathmann et al., Phys. Rev. Accel. Beams 29, 021001 (2026), to evaluate beam-induced depolarization of the Atomic Polarized Hydrogen Gas Jet (HJET) target at the Electron–Ion Collider (EIC) is presented. It is shown that several key assumptions underlying that analysis—including the introduction of a photon emission threshold, the application of Fermi’s Golden Rule to coherent hyperfine transitions, the interpretation of power broadening as a physical linewidth increase, and the treatment of spatial magnetic fields—are either incorrect or internally inconsistent. As a consequence, the predicted large depolarization effects are demonstrated to be artifacts of the adopted methodology rather than genuine physical phenomena. A consistent quantum-mechanical treatment based on the time-dependent Schrödinger equation shows that beam-induced depolarization probabilities at the EIC are negligibly small.

43 PARTICLE ACCELERATORS↗

Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips

The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.

36 MATERIALS SCIENCE↗

Cloud Atlas: High-precision HST/WFC3/IR Time-resolved Observations of Directly Imaged Exoplanet HD 106906b

HD 106906b is an ∼11M{sub Jup}, ∼15 Myr old directly imaged exoplanet orbiting at an extremely large distance from its host star. The wide separation (7.″11) between HD 106906b and its host star greatly reduces the difficulty in direct-imaging observations, making it one of the most favorable directly imaged exoplanets for detailed characterization. In this paper, we present HST/WFC3/IR time-resolved observations of HD 106906b in the F127M, F139M, and F153M bands. We have achieved ∼1% precision in the lightcurves in all three bands. The F127M lightcurve demonstrates marginally detectable (2.7σ significance) variability with a best-fitting period of 4 hr, while the lightcurves in the other two bands are consistent with flat lines. We construct primary-subtracted deep images and use these images to exclude additional companions to HD 106906 that are more massive than 4 M{sub Jup} and locate at projected distances of more than ∼500 au. We measure the astrometry of HD 106906b in two HST/WFC3 epochs and achieve precisions better than 2.5 mas. The position angle and separation measurements do not deviate from those in the 2004 HST/ACS/HRC images for more than 1σ uncertainty. We provide the HST/WFC3 astrometric results for 25 background stars that can be used as reference sources in future precision astrometry studies. Our observations also provide the first 1.4 μm water band photometric measurement for HD 106906b. HD 106906b’s spectral energy distribution and the best-fitting BT-Settl model have an inconsistency in the 1.4 μm water absorption band, which highlights the challenges in modeling atmospheres of young planetary-mass objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Photometric Objects Around Cosmic Webs (PAC) Delineated in a Spectroscopic Survey. IV. High-precision Constraints on the Evolution of the Stellar–Halo Mass Relation at Redshift z < 0.7

Taking advantage of the Photometric objects Around Cosmic webs method developed in Paper I, we measure the excess surface density $\overline{n}$ 2 w p of the photometric objects around spectroscopic objects down to stellar masses 10 8.0 M ⊙ , 10 9.2 M ⊙ , and 10 9.8 M ⊙ in the redshift ranges of z s < 0.2, 0.2 < z s < 0.4, and 0.5 < z s < 0.7, respectively, using data from the DESI Legacy Imaging Surveys and spectroscopic samples from the Sloan Digital Sky Survey (i.e., the Main, LOWZ, and CMASS samples). We model the measured in an N-body simulation, using the abundance matching method, and we constrain the stellar–halo mass relations (SHMRs) in the three redshift ranges to percent levels. With the accurate modeling, we demonstrate that the stellar mass scatter for a given halo mass is nearly a constant, and that the empirical form of Behroozi et al. describes the SHMR better than the double-power-law form at low mass. Our SHMR accurately captures the downsizing of massive galaxies from z s = 0.7, while it also indicates that small galaxies are still growing faster than their host halos. The galaxy stellar mass functions (GSMFs) from our modeling are in perfect agreement with the model-independent measurements in Paper III, although the current work extends the GSMFs to a much smaller stellar mass. Based on the GSMFs and the SHMRs, we derive the stellar mass completeness and halo occupation distributions for the LOWZ and CMASS samples, which are useful for correctly interpreting their cosmological measurements, such as galaxy–galaxy lensing and redshift space distortion.

79 ASTRONOMY AND ASTROPHYSICS↗

An R shiny graphical user interface for highprecision mass spectrometric data analysis

• There is currently a lack of software that meets the needs for the analysis of raw data produced by modern isotope ratio mass spectrometers for both R&D and routine use at SRNL and other US national labs • Needs to accommodate multiple isotope systems, instruments, and manufacturers • Include modern statistical methods and handling/visualization of uncertainty • Flexible software with transparent (no “black box”) and reproducible methods • This project is inspired by existing discipline-specific data analysis software (e.g., Tripoli1 , ET_Redux2, IsoplotR3) used in the geochemical community • Our goal is to build an open source data analysis software package that focuses on flexibility, transparency, and reproducibility

LABONE, ELIZABETH↗

Jefferson Lab High Precision Proton Radius Measurement Experiment: PRad

Proton is not a point-like particle; it has a finite size and an internal structure. The proton charge radius is usually measured through two different methods: using spectroscopy of hydrogen atoms, or through electron-proton (e - p) elastic scattering at low momentum transfer. In 2010, Phol et al [1] published a new measurement for proton charge radius obtained using the spectroscopy method from muonic hydrogen atoms. An ordinary hydrogen (H) atom is a bound state of an electron orbiting a proton. Likewise, a muonic hydrogen atom has a muon orbiting a proton. Since a muon has 200 times more mass than an electron, resulting in a much smaller orbiting radius, its orbit is much more sensitive to the proton charge distribution in space than the electron’s of an ordinary H-atom. Thus, the measurement from muonic hydrogen provides a 10 times more precise result than the previous methods. The radius from the muonic hydrogen measurement reported in [1] was significantly smaller than all the p

Bai, Xinzhan↗