Search NASA⌕ Search

SEARCH · Search NASA

Results for “high purity isotopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Ra-226 extraction and purification from simulated uranium tailings

Growing demand for Ac-225 has outstripped current production, increasing interest in alternative production routes. Furthermore, these often rely on irradiations of Ra-226, yet Ra-226 supplies are also limited. Uranium tailings provide an abundant source of Ra-226, though separation from these complex matrices remains challenging. A laboratory-scale process was developed to recover Ra-226 from simulated U-tailings. After acid leaching, Ra remained adsorbed on refractory oxides and silicates. An additional CaCl₂ leach of the residue raised recovery to ~ 64%. Subsequent purifications, including precipitation, ion-exchange, and extraction chromatography (TK101), achieved chemical yields up to 73 ± 7%, producing 7.68 ± 0.1 µCi of high-purity Ra-226.

and nuclear chemistry↗

Design Report on the MiniFuel Instrumented Test Apparatus for Understanding Radiation Effects

Most nuclear fuels irradiations at Oak Ridge National Laboratory (ORNL) over the past decade have been conducted using MiniFuel—a static capsule design employing subscale fuel specimens to collect separate-effects irradiated fuel performance data. Irradiation conditions for MiniFuel experiments are predicted pre-test using reactor physics, and thermal models are verified post-irradiation via SiC dilatometry and various spectrometry methods. Relevant fuel performance parameters are also observed post-irradiation in a hot cell, thereby providing a single data point for each parameter representing the cumulative effects of the irradiation conditions. Substantially more data can be harvested from a single test and within a shorter duration by instrumenting irradiation vehicles and measuring desired quantities in situ. This report presents the design and analysis of the MiniFuel INstrumented Irradiation Test Apparatus for Understanding Radiation Effects (MINITAURE)—an instrumented test rig based on the separate-effects MiniFuel concept that aims to capture fission gas release (FGR) and thermal conductivity degradation of fuel specimens during irradiation in the High Flux Isotope Reactor (HFIR). MINITAURE will be integrated with the Materials Irradiation Facility (MIF) located in the HFIR building outside the reactor containment. The MIF will act as the instrumentation and control center for the experiment, enabling real-time feedback from in situ sensors and control of irradiation temperatures via a gas delivery system. Two unique capsule designs were developed to capture each phenomenon: the thermal conductivity capsule, which uses a thermopile method to estimate fuel specimen thermal conductivity, and the fission gas release capsule, which will have continuous flowing gas communication to high-purity germanium detectors that are housed in the MIF for monitoring FGR. This report details the reactor physics and heat transfer modeling activities that were used to inform the experiment design and predict capsule performance. It also describes out-of-pile activities conducted to stand up this new capability and verify the measurement techniques. Modeling efforts to date have demonstrated the feasibility of the in situ measurement techniques and supported the development of the MINITAURE assembly configuration. Out-of-pile testing of the thermal conductivity measurement shows promise in capturing relative changes in thermal conductivity. However, significant errors exist in the measured absolute value, posing a need for further refinement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

UCGretina geant4 simulation of the GRETINA Gamma-Ray Energy Tracking Array

UCGretina, a geant4 simulation of the GRETINA gamma-ray tracking array of highly-segmented high-purity germanium detectors is described. We have developed a model of the array, in particular of the Quad Module and the capsules, that gives good agreement between simulated and measured photopeak efficiencies over a broad range of gamma-ray energies and reproduces the shape of the measured Compton continuum. Both of these features are needed in order to accurately extract gamma-ray yields from spectra collected in in-beam gamma-ray spectroscopy measurements with beams traveling at v / c ≳0.3 at the National Superconducting Cyclotron Laboratory and the Facility for Rare Isotope Beams. In the process of developing the model, we determined that millimeter-scale layers of passive germanium surrounding the active volumes of the simulated crystals must be included in order to reproduce measured photopeak efficiencies. In conclusion, we adopted a simple model of effective passive layers and developed heuristic methods of determining passive-layer thicknesses by comparison of simulations and measurements for a single crystal and for the full array. Prospects for future development of the model are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for double-β decay of 76 Ge to excited states of 76 Se with the Majorana Demonstrator

The M AJORANA DEMONSTRATOR is a neutrinoless double-β decay search consisting of a low-background modular array of high-purity germanium detectors, ~2/3 of which are enriched to 88% in 76 Ge. The experiment is also searching for double-beta decay of 76 Ge to excited states (e.s.) in 76 Se. 76 Ge can decay into three daughter states of 76 Se, with clear event signatures consisting of a ββ-decay followed by the prompt emission of one or two γ rays. This results with high probability in multi-detector coincidences. In this work, the granularity of the DEMONSTRATOR detector array enables powerful discrimination of this event signature from backgrounds. Using 41.9 kg yr of isotopic exposure, the DEMONSTRATOR has set world leading limits for each e.s. decay of 76 Ge, with 90% CL lower half-life limits in the range of (0.75–4.0) × 10 24 yr. In particular, for the 2ν transition to the first 0 + e.s. of 76 Se, a lower half-life limit of 7.5 × 10 23 yr at 90% CL was achieved.

59 ≤ A ≤ 89↗

First on-line detection of radioactive fission isotopes produced by laser-accelerated protons

Abstract The on-going developments in laser acceleration of protons and light ions, as well as the production of strong bursts of neutrons and multi- $$\hbox {MeV}$$ MeV photons by secondary processes now provide a basis for novel high-flux nuclear physics experiments. While the maximum energy of protons resulting from Target Normal Sheath Acceleration is presently still limited to around $$100 \, \hbox {MeV}$$ 100 MeV , the generated proton peak flux within the short laser-accelerated bunches can already today exceed the values achievable at the most advanced conventional accelerators by orders of magnitude. This paper consists of two parts covering the scientific motivation and relevance of such experiments and a first proof-of-principle demonstration. In the presented experiment pulses of $$200 \, \hbox {J}$$ 200 J at $$\approx \, 500 \, \hbox {fs}$$ ≈ 500 fs duration from the PHELIX laser produced more than $$10^{12}$$ 10 12 protons with energies above $$15 \, \hbox {MeV}$$ 15 MeV in a bunch of sub-nanosecond duration. They were used to induce fission in foil targets made of natural uranium. To make use of the nonpareil flux, these targets have to be very close to the laser acceleration source, since the particle density within the bunch is strongly affected by Coulomb explosion and the velocity differences between ions of different energy. The main challenge for nuclear detection with high-purity germanium detectors is given by the strong electromagnetic pulse caused by the laser-matter interaction close to the laser acceleration source. This was mitigated by utilizing fast transport of the fission products by a gas flow to a carbon filter, where the $$\upgamma$$ γ -rays were registered. The identified nuclides include those that have half-lives down to $$39 \, \hbox {s}$$ 39 s . These results demonstrate the capability to produce, extract, and detect short-lived reaction products under the demanding experimental condition imposed by the high-power laser interaction. The approach promotes research towards relevant nuclear astrophysical studies at conditions currently only accessible at nuclear high energy density laser facilities.

07 ISOTOPE AND RADIATION SOURCES↗

Production of High Specific Activity 155 Tb, 161 Tb and 203 Pb for Research and Clinical Applications: Effective Target Design, Target Material Recycling and Radioisotope Separation (Final Technical Report)

The overall objectives of this project were (1) to develop methods for the production and separation of a diagnostic and therapeutic or “theranostic” pair of radioisotopes, terbium-155 ( 155 Tb) and terbium-161 ( 161 Tb) and (2) to train graduate students and postdoctoral fellows in technologies and methods used in radionuclide production. Radionuclides can be incorporated into drugs called radiopharmaceuticals that target a specific disease (e.g., cancer). The need for theranostic radionuclides is escalating with the clinical translation of radiopharmaceuticals due to their implementation in personalized medicine, which has demonstrated enhanced patient treatments. High purity and high specific activity radionuclides are critical for theranostic agent development, for example to maintain diagnostic image quality, to minimize radiation dose to the patient, and to increase uptake in the targeted tissue (e.g., tumor), especially in the case of receptor- and antigen-targeted agents. The 155 Tb (diagnostic) and 161 Tb (therapeutic) radioisotopes that were generated through this project are a theranostic pair with demonstrated potential for the development and translation into individualized, targeted, and dosimetry-driven radiotherapies. However, the development of such radiotherapies has been hindered by the lack of a routine and reliable supply of these isotopes in the United States. Methods for the production, separation, and supply of 155 Tb and 161 Tb were investigated and developed in this project. Further, the strong emphasis throughout the project on the training of graduate students and postdoctoral fellows has helped to ensure and enhance the nuclear science workforce through the training of the next generation of highly qualified scientists in nuclear and radiochemistry. This grant also continued a collaboration between scientists at the University of Washington (UW), the University of Missouri (MU) and Brookhaven National Laboratory (BNL). All three institutions were involved in the project, but to different degrees on the various tasks through which the overall objectives were met.

07 ISOTOPE AND RADIATION SOURCES↗

Gamma-ray spectrometry analysis methods for radioisotope dissolution and mixing for nuclear forensics applications

We report the production of surrogate nuclear explosive debris involves the dissolution of irradiated fissile material, elemental isolation, and recombination based on required fission product ratios. Gamma-ray spectrometry is used following each step to assess the radioactive fission product inventory. A high-purity germanium detector is used to measure each sample, and the detector efficiencies are determined prior to sample measurements. Through radiochemical techniques, elements are isolated and recombined into samples with specific fission product ratios. As a result, a matrix-based approach can account for imperfect chemical separations to calculate the proper mixture volumes to obtain intended volatile-to-refractory fission product ratios, or R-values.

07 ISOTOPE AND RADIATION SOURCES↗

Exploring rapid chemical separations of Sc-47 produced from photonuclear reactions on natural vanadium targets

Scandium-47 ( 47 Sc) production via bremsstrahlung irradiation of natural vanadium targets offers significant advantages for producing high purity 47 Sc; this work evaluates several rapid dissolution and chemical separation techniques for recovering high purity 47 Sc from irradiated vanadium. Here, techniques developed are combined into a simple, gram-scale, semi-automated target processing system that enables 47 Sc recovery from irradiated vanadium targets with chemical yields as high as 93 ± 3% and 47 Sc/V separation factors of 6 ± 3 ·10 11 within 90 min total processing times. Future research into H 2 O 2 resistant separation techniques and their applicability for direct process coupling to chelation are recommended.

07 ISOTOPE AND RADIATION SOURCES↗

High purity 47 Sc production using high-energy photons and natural vanadium targets

We report Scandium-47 ( 47 Sc) is of high value for targeted radiotherapy and theranostics; we report a novel, cost-effective approach to produce extremely high-purity 47 Sc via photonuclear irradiation of natural vanadium. Irradiations at bremsstrahlung end-point energies below 26 and at 38 MeV produce > 99.99% and 98.8 ± 3.1% pure 47 Sc (respectively). Linear scaling of experimental data suggests producing 100+ mCi quantities of 47 Sc may be feasible via this approach. Future research into refinement and scale-up to support pre-clinical and clinical research with this production pathway is recommended.

07 ISOTOPE AND RADIATION SOURCES↗

Assessment of Impurities in Neptunium Metal Using Double-Focusing SF-ICP-MS

In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing, with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of narrower slits

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of the 70 Ge( d , n ) 71 As cross section from 2.1 MeV to 10 MeV

This work reports experimental 70 Ge(d,n) 71 As cross sections producing Arsenic-71 (t 1/2 = 65.3 h, 28% β + ), a potentially useful diagnostic radionuclide. Target stacks containing two nat Ge foils, a nat Ni monitor foil, and an Al degrader were irradiated with 5.5–10 MeV deuterons using an FN Tandem Van de Graaff accelerator. 71 As and 61 Cu, 56 Co, and 58 Co (from nat Ni(d,x)) were quantified in the foils by high purity germanium gamma spectrometry. Furthermore, the measured cross sections are larger than previously reported and suitable for producing preclinical quantities of diagnostic radiopharmaceuticals.

07 ISOTOPE AND RADIATION SOURCES↗

Extraction and isotopic analysis of medium molecular weight hydrocarbons from Murchison using supercritical carbon dioxide

The large variety of organic compounds present in carbonaceous chondrites poses particular problems in their analysis not the least of which is terrestrial contamination. Conventional analytical approaches employ simple chromatographic techniques to fractionate the extractable compounds into broad classes of similar chemical structure. However, the use of organic solvents and their subsequent removal by evaporation results in the depletion or loss of semi-volatile compounds as well as requiring considerable preparative work to assure solvent purity. Supercritical fluids have been shown to provide a powerful alternative to conventional liquid organic solvents used for analytical extractions. A sample of Murchison from the Field Museum was analyzed. Two interior fragments were used; the first (2.85 g) was crushed in an agate pestel and mortar to a grain size of ca. 50-100 micron, the second (1.80 g) was broken into chips 3-8 mm in size. Each sample was loaded into a stainless steel bomb and placed in the extraction chamber of an Isco supercritical fluid extractor maintained at 35 C. High purity (99.9995 percent) carbon dioxide was used and was pressurized using an Isco syringe pump. The samples were extracted dynamically by flowing CO2 under pressure through the bomb and venting via a 50 micron fused filica capillary into 5 mls of hexane used as a collection solvent. The hexane was maintained at a temperature of 0.5 C. A series of extractions were done on each sample using CO2 of increasing density. The principal components extracted in each fraction are summarized.

Gilmour, Iain↗

Production of Radiohalogens: Bromine and Astatine for Imaging and Therapy

Objective: This collaborative proposal between the University of Alabama at Birmingham (UAB), University of Wisconsin, Madison (UWisc) and the University of Pennsylvania (Penn) aims to research the efficient production of high purity, clinical grade radiohalogens for preclinical and translational applications by optimizing the cyclotron targetry and separation chemistry of 76,77Br and 211At for use in imaging and therapy. Proposed Research and Methods: During the course of this project, faculty and trainees at our three institutions will use the complementary infrastructure available to examine the 76Se(p,n)76Br, 77Se(p,n)77Br, 78Se(p,2n)77Br, natAs(α,2n)77Br ,80Kr(p,α)77Br and 209Bi(α, 2n)211At reactions as routes to the production of these valuable radiohalogens for imaging and therapy. Working together we aim to optimize both solid and gas targetry, including reclamation of expensive enriched material. We will develop high yielding recovery processes based on dry distillation and ion exchange techniques. We will also create a comprehensive set of quality control procedures to ensure we are producing our radioisotopes in the highest radiochemical and chemical purity possible. By bringing three institutions together to perform research and development we provide the unique opportunity to build an everlasting cooperative culture in the field of nuclear medicine research by enabling academic centers to delve into the fields of radiohalogen chemistry. In addition, each institution involved holds different skills and expertise and a collaborative grant will facilitate the cross-pollination of ideas, techniques, and build strong bonds that unite under the DOE mission. Additionally, our work does not stop at the completion of this proposal, rather this proposal allows us to gain the momentum needed to get our research and developmental efforts off the ground thereby creating a network of three institutions dedicated to the advancement of isotope production for medical research.

07 ISOTOPE AND RADIATION SOURCES↗

Single-Step Conversion of Ethanol to n-Butene over Ag-ZrO2/SiO2 Catalysts

Ethanol is a promising platform molecule for production of a variety of fuels and chemicals. Of particular interest is producing middle distillate fuels (i.e., jet and diesel blendstock) from renewable ethanol feedstock. State-of-the-art alcohol-to-jet technology requires multiple process steps based on catalytic dehydration of ethanol to form ethylene, followed by sometimes a multi-step oligomerization, and then hydrotreatment and distillation. Here we report on a new catalytic route in which ethanol is directly converted to n-butene (1- and 2-butene mixtures) over Ag-ZrO2/SBA-16, thus offering the potential for a reduction in the number of required processing steps versus conventional alcohol-to-jet technology. This catalyst system provides the balanced metal and Lewis acid sites required to selectively facilitate a cascading sequence of reactions that includes dehydrogenation, aldol condensation, Meerwein–Ponndorf–Verley reduction, dehydration, and hydrogenation. High conversion and selectivity toward either n-butene or 1,3-butadiene is achieved by tuning the hydrogen feed partial pressure and other process/catalyst parameters. With sufficient hydrogen partial pressure 1,3-butadiene is completely and selectively hydrogenated to form n-butene. The reaction mechanism was elucidated through operando-nuclear magnetic resonance investigations coupled with reactivity measurements. Combined experimental-computational investigation reveals how changes in silver and zirconium composition and the silver oxidation state affects reactivity under controlled hydrogen partial pressures and after prolonged run times. Finally, catalyst effectiveness also was demonstrated when using wet ethanol feed, thus highlighting process flexibility in terms of feedstock purity requirements. This work was financially supported by the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy, Bioenergy Technologies Office, and was performed at the Pacific Northwest National Laboratory (PNNL) under Contract No. DE-AC05-76RL01830 and the National Renewable Energy Laboratory under Contract No. DE-AC36- 08GO28308. Part of the work conducted by S. A. Akhade was performed under the auspices of the U.S. DOE at Lawrence Livermore National Laboratory under Contract No. DE-AC52-07NA27344. This work was partly supported through the PNNL-WSU Distinguished Graduate Research Program for ADW. NMR and XPS experiments were performed using EMSL (grid.436923.9), a DOE Office of Science User Facility sponsored by the Office of Biological and Environmental Research

Dagle, Vanessa↗

Investigation of ASIC-based signal readout electronics for LEGEND-1000

LEGEND, the Large Enriched Germanium Experiment for Neutrinoless ββ Decay, is a ton-scale experimental program to search for neutrinoless double beta (0νββ) decay in the isotope 76 Ge with an unprecedented sensitivity. Building on the success of the low-background 76 Ge-based GERDA and Majorana Demonstrator experiments, the LEGEND collaboration is targeting a signal discovery sensitivity beyond 10 28 yr on the decay half-life with approximately 10 t∙yr of exposure. Signal readout electronics in close proximity to the detectors plays a major role in maximizing the experiment's discovery sensitivity by reducing electronic noise and improving pulse shape analysis capabilities for the rejection of backgrounds. However, the proximity also poses unique challenges for the radiopurity of the electronics. Application-specific integrated circuit (ASIC) technology allows the implementation of the entire charge sensitive amplifier (CSA) into a single low-mass chip while improving the electronic noise and reducing the power consumption. In this work, we investigated the properties and electronic performance of a commercially available ASIC CSA, the XGLab CUBE preamplifier, together with a p-type point contact high-purity germanium detector. We show that low noise levels and excellent energy resolutions can be obtained with this readout. Moreover, we demonstrate the viability of pulse shape discrimination techniques for reducing background events.

47 OTHER INSTRUMENTATION↗

In-Situ Reaction Monitoring for Lunar Applications Utilizing a Single Quadrupole Residual Gas Analyzer

With a revived focus to create a permeant presence on the moon and in preparation for future Mars exploration, it is imperative that all re-sources are utilized to their fullest potential. In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable independent operation of missions while minimally relying on the complex supply chain created between the Earth, moon and Mars. One of the most critical resources that have been identified for ISRU is the creation of liquid oxygen (O2) for not only breathable air, but also for rocket fuel. On the moon and potentially Mars, one of the most O2 rich resources is in the presence of regolith. Although there are numerous minerals within regolith and various processes to extract O2, this is not the scope of this paper. Since the O2 extraction method can vary, a critical standardized analytical method is needed to verify O2 (or oxygenated precursor compounds) for extraction efficiency and purity. Our group utilizes a modified consumer off-the-shelf (COTS), Residual Gas Analyzer (RGA) Single Quadrupole Mass Spectrometer (QMS). Due to the current field mission requirements, the gas analysis module will need to rely only on mass-to-charge ratios (m/z) and peak intensities to differentiate and quantitate targeted gas-phase reactants or products, i.e. carbon monoxide (CO), carbon dioxide (CO2), methane (CH4) and hydrogen (H2). However, due to solar wind implanted volatiles and various other compounds present in lunar regolith, such as nitrogen (N2), helium (He), and deuterium (D2), deconvolution and quantification of isobaric compounds becomes quite difficult. Specifically, the presence of N2 makes quantification of CO, an oxygenated precursor, difficult due to both compounds having a peak at m/z 28. Approaches to differentiate isobaric components: Initially, the solution to overcome isobaric overlap was to use isotopic ratios, particularly be-tween carbon-13 and nitrogen-15. Although limited literature discuss isotopic composition and attempt to quantify the ratios, variation is particularly high and limited to a few lunar regolith samples. The following were identified as potential approaches to quantify isobaric species, N2 and CO, using our RGA. Threshold Ionization. CO and N2 both have peaks at m/z 28, but only N2 is capable of producing a peak at m/z 7. While a N2 peak at m/z 7 is generally rare, instrument parameters can be optimized in order to maximize the peak intensity. Typically a standard ionization energy of 70 eV is used to monitor a batch process and would produce reliable results for a majority of the reactants or products that we are interested in quantifying. However, to analyze the rare molecular fragment of N2 (N2+ at m/z 7), a different ionization energy may be beneficial. Threshold Ionization Mass Spectrometry (TIMS) will be explored to optimize the N2+ peak at m/z 7 by varying parameters such as ionization energy and pressure. Therefore, a quantitative value at m/z 7 will be used to determine the product gas concentration of N2, which will be subtracted from the total concentration determined at m/z 28 enabling us to approximate the amount of CO. Secondary Detector (infrared gas detector, IR). Another approach to quantitate and differentiate be-tween isobaric components is to leverage alternative modes of detection. Unlike mass spectrometry, which generally uses a separation step prior to analysis (i.e. gas chromatography), IR produces energy that is specifically absorbed depending on the bond and configuration of the molecule. This technique could be leveraged since it is generally only active on non-symmetric molecules, i.e. CO. Utilizing concentrations of CO determined from another detector could help correct concentrations of CO obtained from the QMS. However, the inclusion of another detector adds additional mission requirements, such as power, software changes and avionics updates that add additional cost and schedule requirements.

mass spectrometry↗

Natural and enriched Cr target development for production of Manganese-52

52 Mn is a promising PET radiometal with a half-life of 5.6 days and an average positron energy of 242 keV. Typically, chromium of natural isotope abundance is used as a target material to produce this isotope through the nat/52 Cr(p,n) 52 Mn reaction. While natural Cr is a suitable target material, higher purity 52 Mn could be produced by transitioning to enriched 52 Cr targets to prevent the co-production of long-lived 54 Mn (t 1/2 = 312 day). Unfortunately, 52 Cr targets are not cost-effective without recycling processes in place, therefore, this work aims to explore routes to prepare Cr targets that could be recycled. Natural Cr foils, metal powder pellets, enriched chromium-52 oxide and Cr(III) electroplated targets were investigated in this work. Each of these cyclotron targets were irradiated, and the produced 52 Mn was purified, when possible, using a semi-automated system. An improved purification by solid-phase anion exchange from ethanol-HCl mixtures resulted in recoveries of 94.5 ± 2.2% of 52 Mn. The most promising target configuration to produce a recyclable target was electroplated Cr(III). This work presents several pathways to optimize enriched Cr targets for the production of high purity 52 Mn.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Separation of rare earth element radioisotopes by reverse-phase high-speed counter-current chromatography

Analytical scale purification of rare earth element (REE) radioisotopes is typically accomplished using cation-exchange resins (e.g. AG 50W-X8) and high-performance liquid chromatography (HPLC). Despite the variety of improvements made since the development of this separation process in the 1950s, nearest neighbor separations remain a challenge, as does the issue of irreversible sample adsorption. Herein, we report a study that evaluates the potential of high-speed counter-current chromatography (HSCCC) as an alternative method for purifying REE elements, with specific reference to separations of fission product REE of interest to nuclear forensics. Complementary HSCCC REE separation experiments, one spiked with radiotracer and REE fission product activity, allowed for in depth analysis of resulting fractions from both an elemental (inductively coupled plasma atomic emission spectroscopy, ICP-AES) and radiological (gamma-ray spectrometry, beta counting) purity perspective. The highly reproducible nature of separation profiles generated from HSCCC instruments was leveraged to simplify work-up of samples containing radioisotopes. Subsequent radioanalytical evaluation revealed minimal carryover of Eu into neighboring Sm and Tb fractions (as indicated by presence of 150Eu), and trace contamination of the Tb fraction with Y (as indicated by presence of 91Y). Subtle differences in stationary phase retention across the two columns were reflected in significant variations in decontamination factors of duplicate parallel separations. Furthermore, these differences paired with obtained distribution of radioisotopes provided valuable insights into future improvements. Collectively, this study represents a significant step forward in development of HSCCC technology for task specific REE radioisotope purification.

07 ISOTOPE AND RADIATION SOURCES↗