Search NASA⌕ Search

SEARCH · Search NASA

Results for “hot water”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Demonstration of μCHP in Light Commercial Hot Water Applications

Internal combustion engine driven combined heat and power (CHP) systems produce power while the waste heat is recovered and used for another purpose. For µCHP systems (less than 50kWe output) overall efficiencies can reach over 90% for products currently on the market throughout the world. On a fuel basis this offers an advantage over using grid-based power and another fuel for heat. Additionally, the cost of natural gas on an energy unit basis is significantly less expensive than electric power. This difference can lead to substantial savings for the end user of a CHP system. In some parts of the world, particularly Germany and Japan, µCHP has become a common part of the heat and distributed generation equipment mix. Market analysis conducted in 2012 showed that in North America there is potential of a 5,300 units per year market for µCHP, resulting in an annual energy savings of approximately 13.5 TBtu and more than $84 million in annual customer savings. However, µCHP still has not seen much market penetration in North America. This study helps to identify some of the reasons why, address roadblocks that still need to be overcome and provide experience to established best practices. Nine commercial sites were initially identified (fitness club, surgical center, senior community, resort and spa, commercial laundry, two multi-family housing, restaurant and manufacturing facility). Systems from two different manufacturers were installed at five sites total, but due to unforeseen circumstances, only three of those sites were finally commissioned: test data were collected by Oak Ridge National Laboratory. While not all systems were installed as intended, the project resulted in the following key findings: Micro combined heat and power is an unfamiliar technology for building owners and plumbing and electrical contractors that serve the buildings most suited for µCHP. Manufacturers will need to be aggressive in providing training and providing broad support to successfully bring the technology to market.; The proper integration of µCHP into other building systems is the most critical part of a successful installation. Manufacturers will need to be able to provide the expertise to train, advise and support the mechanical contractors during the design and installation of the heat integration system.; Regulations governing µCHP varies across the country. There are a few UL standards (UL 2200 and UL 1741) that apply nationally. Emissions are governed by EPA except in California where the California Air Resources Board (CARB) has established their own standard. Requirements that dictate installation and interconnection are dependent on local building codes and local utility processes and requirements. Some out of date building codes do not offer clear guidance for these requirements, leading to confusion. This makes developing training and determining broadly applicable best practices difficult.; Installation costs of µCHP are a key factor in making an installation successful. It is critical that these costs and all national, state and local regulations be understood and accounted for by all parties involved in the installation before a project is undertaken.; A robust customer service organization is important to meet the needs of the customers. These systems require annual maintenance and service and local capability is needed to keep costs inline.

03 NATURAL GAS↗

Salts in Hot Water: Developing a Scientific Basis for Supercritical Desalination and Strategic Metal Recovery

Given the steady growth in world population and the ever-increasing fresh water demand, the only sustainable water supply option is desalination. Conceptually, desalination is very simple - just separate dissolved salts from water. While desalination research programs have existed since the 1960s and have resulted in a multitude of approaches, realizing affordable desalination has proven to be a challenge. Our goal is to meet this challenge using low cost heat sources to drive a liquid-discharge-free desalination process that can be co-mingled with the extraction of economically valuable co-products. High temperatures and pressures will be used to manipulate water’s properties, such as the dielectric constant, and hence its ability to solvate ions. Selective precipitation/recovery of valuable metal co-products creates new revenue streams (i.e., cost offsets). We will develop the scientific understanding necessary to control salt precipitation from supercritical seawater, inland brines, and water commonly co-produced with oil and gas. Atomistic simulations will be used to understand at a molecular level the changes in hydrogen bonding and ion solvation that occur as we increase the temperature and/or pressure and change the density and ion concentration. Our simulation results will also aid in the interpretation of experimental data and guide the development of applied thermodynamic models for engineering design calculations.

58 GEOSCIENCES↗

Salts in Hot Water: Developing a Scientific Basis for Supercritical Desalination and Strategic Metal Recovery

The w21_superdesal project is part of an LDRD-DR on supercritical desalination (20190057DR). The goal of the simulation work is to use atomistic simulations to understand at a molecular level the changes in hydrogen bonding and ion solvation that occur as we increase the temperature and/or pressure and change the density and ion concentration. Our simulation results will also aid in the interpretation of experimental data and guide the development of applied thermodynamic models for engineering design calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Air-liquid solar collector for solar heating, combined heating and cooling, and hot water subsystems

A collection of quarterly reports consisting of the installation and layout design of the air collector system for commercial applications, completion of the preliminary design review, detailed design efforts, and preparation of the verification test plan are given. Performance specifications and performance testing of a prototype model of a two manifold, 144 tube air collector array is presented.

Source record↗

System design package for SIMS prototype system 4, solar heating and domestic hot water

The system consisted of a modular designed prepackaged solar unit, containing solar collectors, a rock storage container, blowers, dampers, ducting, air-to-water heat exchanger, DHW preheat tank, piping, and system controls. The system was designed to be installed adjacent to a small single family dwelling. The description, performance specification, subsystem drawings, verification plan/procedure, and hazard analysis of the system were packaged for evaluation.

Source record↗

Solar heating, cooling, and hot water systems installed at Richland, Washington

The project described is part of the U. S. Department of Energy's solar demonstration program, and became operational in April 1978. The solar system uses 6,000 square feet of flat-plate liquid collectors in a closed loop to deliver solar energy through a liquid-liquid heat exchanger to the building heat-pump duct work or 9,000-gallon thermal energy storage tank. A 25-ton Arkla solar-driven absorption chiller provides the cooling, in conjunction with a 2,000 gallon chilled water storage tank and reflective ponds on three sides of the building surplus heat. A near-by building is essentially identical except for having conventional heat-pump heating and cooling, and can serve as an experimental control. An on-going public relations program was provided from the beginning of the program, and resulted in numerous visitors and tour groups.

Source record↗

Solar-heating and hot water system--St. Louis, Missouri

Sunlight supplies about half heat energy needs of small office. System includes six tilt-adjustable commercial collectors and 1,000 gallon energy storage tank. Report contains description of system and components, drawings and photographs, manufacturer's data, and related material.

Source record↗

Economic evaluation of a solar hot-water-system

Analysis shows economic benefits at six representative sites using actual data from Tempe, Arizona and San Diego, California installations. Model is two-tank cascade water heater with flat-plate collector array for single-family residences. Performances are forecast for Albuquerque, New Mexico; Fort Worth, Texas; Madison, Wisconsin; and Washington, D.C. Costs are compared to net energy savings using variables for each site's environmental conditions, loads, fuel costs, and other economic factors; uncertainty analysis is included.

Source record↗

Hot-water aquifer storage: A field test

The basic water injection cycle used in a large-scale field study of heat storage in a confined aquifer near Mobile, Alabama is described. Water was pumped from an upper semi-confined aquifer, passed through a boiler where it was heated to a temperature of about 55 C, and injected into a medium sand confined aquifer. The injection well has a 6-inch (15-cm) partially-penetrating steel screen. The top of the storage formation is about 40 meters below the surface and the formation thickness is about 21 meters. In the first cycle, after a storage period of 51 days, the injection well was pumped until the temperature of the recovered water dropped to 33 c. At that point 55,300 cubic meters of water had been withdrawn and 66 percent of the injected energy had been recovered. The recovery period for the second cycle continued until the water temperature was 27.5 C and 100,100 cubic meters of water was recovered. At the end of the cycle about 90 percent of the energy injected during the cycle had been recovered.

Parr, A. D.↗

Solar hot water system installed at Mobile, Alabama

The system consists of six rows of ten collectors and three rows of eleven collectors (1990 square feet) mounted on the roof. Griswald flow control valves were installed to regulate the flow to each row. Two Heliotrope electronic thermometers with a combined capability of measuring the temperatures of 22 different locations were installed for monitoring purposes.

Source record↗

Thermographic detection of disbonds

The presence of disbonds significantly decreases the integrity of many laminated structures used in aerospace applications. A thermographic technique is presented which is able to detect subsurface delamination. The technique uses one of several heat sources (such as hot water, hot air, IR lamps, etc.) to increase the surface temperature of the structure. The subsequent temperature profiles of the surface are detected with an IR camera. A novel spatial filter developed at NASA-Langley eliminates the effects of uneven heating to give clear images of the subsurface delaminations. Defects are detectable in samples as diverse as solid rocket motor samples and laminated wood for wind tunnel blades. Numerical simulations are presented for comparison with experiment results.

Winfree, William P.↗

Solafern solar system design brochure

A complete residential solar space heating and hot water system is described. Low maintenance, durable, and efficient air heating collectors are used. The collectors have a selective absorber and a tempered glass cover nearly one-quarter of an inch thick with an aluminum frame. The solar energy can be delivered directly to the living area when there is a demand; otherwise, it is stored in the form of hot water. Hot water storage is accomplished through the use of an air-to-water exchanger. The hot water storage is used simultaneously to preheat the domestic hot water, as well as to store energy for space heating.

Source record↗