Search NASA⌕ Search

SEARCH · Search NASA

Results for “hybrid heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Performance and Total Cost of Ownership of a Fuel Cell Hybrid Mining Truck

The main objective of this work was to investigate the potential of hydrogen and fuel cells replacing diesel and internal combustion engines in the ultraclass haul trucks deployed in the mining sector. Performance, range, durability, and cost are the main criteria considered for comparing the two fuels and engine options. Fuel cell system (FCS) performance is characterized in terms of heat rejection, efficiency, and fuel consumption for a hybrid platform equivalent to a 3500 hp diesel engine operating on a representative open pit mining duty cycle. A hybrid platform was chosen because the heat rejection, with a constrained radiator frontal area, limits the maximum fuel cell-rated power by about 50% compared to that of the diesel truck. The hybrid powertrain was 81–88% more efficient than the diesel powertrain on the truck duty cycle. A liquid hydrogen storage system is required for an equal range or time between refilling, but the packaging remains a challenge. Fuel cell and battery durability were evaluated for their performance degradation and lifetime. Achieving a fuel cell lifetime comparable to the time between major overhauls for diesel trucks necessitates the oversizing of the membrane-active area, catalyst overloading, and voltage clipping. For an equal lifetime, the battery must be oversized to control its depth of discharge and charge/discharge rates. A total cost of ownership (TCO) analysis considering the initial capital expenditures, as well as the lifetime cost of fuel, operation, and maintenance, indicates that fuel cells and hydrogen can compete with diesel. A breakeven fuel cost for TCO parity is obtained if H2 is available at USD 5.79–6.85/kg vs. diesel at USD 3.25/gal and the FCS-specific cost is USD 323/kW e relative to USD 250/kW for a diesel genset. Volume manufacturing is required for FCS cost reduction. High volume is possible through the standardization, modularity, and proliferation of class 8 long-haul truck systems across different heavy-duty applications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Renewable Thermal Energy Systems Designed for Industrial Process Solutions in Multiple Industries

Industrial decarbonization is a key area that must be accelerated, to foster the removal of fossil fuels from the provision of heat, especially at low temperatures less than 300 degrees C. This paper looks at the results of two case studies for understanding the economics and potential for renewable thermal energy systems (RTES), particularly in hybrid configurations to provide industrial process heat (IPH). The first case study looks at heat pumps for district heating, and the second, the use of linear Fresnel collectors (LFCs) coupled with phase change material (PCM) thermal energy storage (TES) for direct steam generation (DSG). Using district heat as an input for the heat pump, three cases were run harvesting energy from ambient water (5 degrees C), sewage water (20 degrees C), and a solar collector (35 degrees C). Accounting for elevated costs of infrastructure for each heat source, the levelized cost of heat (LCOH) of the first case study ranged from $4-$15 per million British Thermal Units (MMBTU). For the second case study modeling LFCs with PCM and TES, the results show that a LCOH of $9-$15 per MMBTU is possible, depending on the direct normal irradiance.

concentrated solar thermal↗

Renewable Thermal Energy Systems Designed for Industrial Process Solutions in Multiple Industries: Preprint

Industrial decarbonization is a key area that must be accelerated, to foster the removal of fossil fuels from the provision of heat, especially at low temperatures less than 300 degrees C. This paper looks at the results of two case studies for understanding the economics and potential for renewable thermal energy systems (RTES), particularly in hybrid configurations to provide industrial process heat (IPH). The first case study looks at heat pumps for district heating, and the second, the use of linear Fresnel collectors (LFCs) coupled with phase change material (PCM) thermal energy storage (TES) for direct steam generation (DSG). Using district heat as an input for the heat pump, three cases were run harvesting energy from ambient water (5 degrees C), sewage water (20 degrees C), and a solar collector (35 degrees C). Accounting for elevated costs of infrastructure for each heat source, the levelized cost of heat (LCOH) of the first case study ranged from $4-$10 per million British Thermal Units (MMBTU). For the second case study modeling LFCs with PCM and TES, the results show that a LCOH of $9-$15 per MMBTU is possible, depending on the direct normal irradiance.

concentrated solar thermal↗

Hybrid Natural Gas Geothermal Combined Cycle Power Plant Analysis

Low temperature geothermal resources, including those associated with oil and gas production, are an underutilized source of low carbon energy. The present work investigates coupling of low-temperature geothermal resources with concentrating solar and/or natural gas energy sources to increase the number of locations at which power generation from low temperature geothermal resources would be technically and economically viable. Stand-alone and hybrid geothermal power cycles are simulated using SimTech IPSEpro process modeling software. Design point strategies for a hybrid power cycle that may operate with either a single heat source or two simultaneous heat input sources are considered. Additionally, off-design power plant operation is investigated to consider the impacts of the heat source availability and ambient temperature variations. The off-design analysis utilizes a modeling tool that predicts power plant performance at each time step as a function of topping cycle heat input (from gas or solar), bottoming cycle heat input (from geothermal), and ambient temperature. Addition of a steam topping cycle to an organic Rankine cycle geothermal power plant provides opportunities to increase the efficiency and power output relative to a stand-alone geothermal power plant. Additionally, use of the waste heat from gas turbine power generation in a geothermal bottoming cycle provides opportunities to increase the amount of power generation associated with each unit of carbon dioxide emitted. This paper will describe the hybrid plant configuration evaluated, discuss the predicted power cycle performance, and compare with stand-alone natural gas and geothermal power generation cases. The power cycle investigated is expected to be applicable for use with conventional hydrothermal resources as well as with geologic thermal energy storage applications and/or enhanced geothermal systems. The steam topping cycle could use a concentrated solar heat source for fully renewable hybrid plant configuration. A plant initially constructed with a natural gas topping cycle heat source could be converted to a solar heat source part way though the power cycle operational life to achieve life cycle carbon emission reductions.

concentrating solar power↗

Techno-Economic Analysis of Greenfield Geothermal Hybrid Power Plants using a Solar or Natural Gas Steam Topping Cycle

The relatively low generation costs associated with wind, solar PV, and natural gas power plants make it challenging for geothermal power plants to produce and sell the power that has the reliability and sustainability characteristics that are greatly needed in US power markets. This is especially true for geothermal resources with low to medium temperatures, which results in relatively low thermal efficiency and generation costs that are higher than those for wind, solar PV, and natural gas. This analysis evaluates solar thermal- and natural gas combustion waste heat recovery-based topping cycle hybridization of geothermal binary power plants. This approach provides several benefits that may allow geothermal power plants to generate power at more competitive costs. First, the addition of solar thermal energy or natural gas combustion waste heat input to a geothermal power plant provides additional heat input that can be converted to electrical power. Second, the temperature level of the heat obtained from concentrating solar collectors or natural gas combustion exhaust is higher than that of geothermal heat, which provides opportunities for improving the efficiency of the conversion of thermal energy to electrical power. Third, the ease with which solar thermal systems integrate with energy storage and the flexibility of natural gas means power generation can occur during peak demand periods.

14 SOLAR ENERGY↗

RF antenna helicity dependent particle heating in a helicon source

Experiments have demonstrated that ion phenomena, such as the lower hybrid resonance, play an important role in helicon source operation. Damping of the slow branch of the bounded whistler wave at the edge of a helicon source (i.e. the Trivelpiece-Gould mode) has been correlated with the creation of energetic electrons, heating of ions at the plasma edge, and anisotropic ion heating. Here we present ion velocity distribution function measurements, electron density and temperature measurements, and magnetic fluctuation measurements on both sides of an m = |1| helical antenna in a helicon source as a function of the driving frequency, magnetic field strength, and magnetic field orientation relative to the antenna helicity. Significant electron and ion heating (up to two times larger) occurs on the side of the antenna consistent with the launch of the m = +1 mode. The electron and ion heating occurs within one electron skin depth of the plasma edge, where slow wave damping is expected. The source parameters for enhanced particle heating are also consistent with lower hybrid resonance effects, which can only occur for Trivelpiece-Gould wave excitation.

wave modes↗

Shear-based deformation processing of age-hardened aluminum alloy for single-step sheet production

Shear-based deformation processing by hybrid cutting-extrusion and free machining are used to make continuous strip, of thickness up to one millimeter, from low-workability AA6013-T6 in a single deformation step. The intense shear can impose effective strains as large as 2 in the strip without pre-heating of the workpiece. The creation of strip in a single step is facilitated by three factors inherent to the cutting deformation zone: highly confined shear deformation, in situ plastic deformation-induced heating and high hydrostatic pressure. The hybrid cutting-extrusion, which employs a second die located across from the primary cutting tool to constrain the chip geometry, is found to produce strip with smooth surfaces (S a < 0.4 μm) that is similar to cold-rolled strip. The strips show an elongated grain microstructure that is inclined to the strip surfaces – a shear texture – that is quite different from rolled sheet. Furthermore, this shear texture (inclination) angle is determined by the deformation path. Through control of the deformation parameters such as strain and temperature, a range of microstructures and strengths could be achieved in the strip. When the cutting-based deformation was done at room temperature, without workpiece pre-heating, the starting T6 material was further strengthened by as much as 30% in a single step. In elevated-temperature cutting-extrusion, dynamic recrystallization was observed, resulting in a refined grain size in the strip. Implications for deformation processing of age-hardenable Al alloys into sheet form, and microstructure control therein, are discussed.

36 MATERIALS SCIENCE↗

Species‐Specific Epigenetic Signature Associates With Heat Stress Tolerance in the Perennial Tree Species Populus

Epigenetic regulation in annual plants is recognized as a key component of recurring stress acclimation and adaptation, but reports on perennial tree species are limited. In this study, two contrasting tree species, Populus trichocarpa and Populus deltoides, and an F1 hybrid cross between them showed species-specific epigenetic and physiological responses to heat stress (42°C) following priming (35°C). By analyzing whole-genome methylation, transcriptomics, proteomics, metabolomics, and photosynthesis parameters, we found that P. deltoides expresses specific epigenetic signatures in response to heat, resulting in improved photosynthetic efficiency compared to P. trichocarpa. Conversely, P. trichocarpa displayed stress signaling and defense mechanisms that could not sustain a net assimilation rate despite maintaining higher gas exchange. Heat stress following priming in hybrid plants increased transcript levels of thermotolerance-related transcription factors, such as SPL12. Selected regions in the promoter of SPL12 showed differential methylation between direct heat stress and priming followed by heat stress. As a result, upregulation of downstream genes and associated increases in protein and metabolite abundance for stress adaptation were exhibited. Consequently, hybrid plants showed enhanced photosynthesis and gas exchange rates, a trait lacking in P. trichocarpa. These results imply that priming may not be universally effective in enhancing plant performance under stress, particularly in perennial tree species. However, priming can acclimate the perennial tree species P. deltoides to withstand elevated temperature stress better. Our study has demonstrated that priming-based stress adaptation is species-specific but can be attained through crossbreeding, indicating its potential use in breeding programs.

DNA methylation↗

Assessing geothermal/solar hybridization – Integrating a solar thermal topping cycle into a geothermal bottoming cycle with energy storage

Geothermal and concentrating solar power (CSP) technologies typically use heat at different temperatures in their commercial deployments. This enables a technically viable hybridization of a solar topping cycle and a geothermal bottoming cycle at locations where both resources are available. In this article, an underperforming geothermal power system based at Burley, Idaho is used as a baseline to investigate the technical and economic potential of such a hybrid cycle. A direct thermal energy storage (TES) system is also integrated to overcome the intermittency of the solar resource. Design and off-design behavior of key components are modelled to simulate the annual performance of the hybrid system on an hourly basis. The sizing of the solar field and thermal storage is investigated and is seen to significantly impact the annual electricity generation and efficiency. Various cost scenarios for the solar field and thermal energy storage are investigated. An economic metric - levelized cost of electricity (LCOE) - is used to optimize the solar field sizing and TES capacity. The hybrid plant converts the additional solar heat input into additional work with an efficiency of 32.9%. Retrofitting a geothermal plant with solar and eight hours of energy storage can achieve an LCOE of 0.136 $/kWhe in current cost scenarios and 0.081 $/kWhe in a future cost reduction scenario. Although the hybrid system cannot directly compete with current PV systems without batteries, it has an LCOE 32% lower than that of a PV-battery system. This paper provides insights into the research and development of the future grid with a high renewable energy penetration and encourages further study of energy hybridization for improved efficiencies and economics.

15 GEOTHERMAL ENERGY↗

Performance of an Isobaric Hybrid Compressed Air Energy Storage System at Minimum Entropy Generation

Efficient, large-scale, and cost-effective energy storage systems provide a means of managing the inherent intermittency of renewable energy sources and drastically increasing their utilization. Compressed air energy storage (CAES) and its derivative architectures have received much attention as a viable solution; however, optimization objectives for these systems have not been thoroughly investigated in the literature. In this work, a hybrid thermal and compressed air energy storage (HT-CAES) system is investigated that mitigates the shortcomings of the otherwise attractive conventional CAES systems and its derivatives—shortcomings such as strict geological locations, low energy densities, and the production of greenhouse gas emissions. The HT-CAES system allows a portion of the available energy to operate a compressor and the remainder to be converted and stored in the form of heat through joule/resistive heating in a high-temperature, sensible, thermal energy storage medium. Internally reversible and irreversible HT-CAES system assumptions were investigated, in addition to regenerative and non-regenerative design configurations. Several system optimization criteria were examined—including maximum energy efficiency, maximum exergy efficiency, maximum work output, and minimum entropy generation—with a focus on whether the latter may lead to conclusive design guidelines in a real system. It is shown that an HT-CAES system designed based on a minimum entropy generation objective may operate at a lower energy and exergy efficiency as well as lower output power than otherwise achievable. Furthermore, optimization objective equivalence is shown to be limited to certain design conditions.

25 ENERGY STORAGE↗

A Hybrid Heavy Duty Diesel Power System for Off-Road Applications—Concept Validation

A multiyear power system R&D program was completed with the objective of developing an off-road hybrid heavy duty diesel engine with front end accessory drive-integrated energy storage. This system was validated to deliver 10.5–25.6% reduction in fuel consumption over current Tier 4 Final-based 18L diesel engines, over various off-road machine application cycles. The power system consisted of a downsized heavy-duty diesel 13L engine containing advanced combustion technologies, capable of elevated peak cylinder pressures and thermal efficiencies, thermal barrier coatings, exhaust waste heat recovery via SuperTurbo™ turbocompounding, and hybrid energy assisting and recovery through both mechanical and electrical systems. Following the concept definition, design, and analysis phases of the program, the final phase focused on building and validating the performance and efficiency in laboratory tests. While aspects of the system such as start/stop and reduced off-road cooling package energy losses were only analytically evaluated, the main 13L concept engine with full hybrid system was successfully built and tested in steady-state and in transient certification and real-world application cycles. Extensive simulations in Caterpillar's DYNASTY™ software environment utilized the validation test data to assess performance more fully and confidently over varied cycles and strategies. An average fuel consumption reduction of 17.9% was realized, and the majority (~13%) of the benefit stemmed from the core concept 13L engine. In conclusion, a total cost of ownership analysis provides context to commercial viability and where adoption focus should be placed.

33 ADVANCED PROPULSION SYSTEMS↗

A Multiscale Approach to Simulate Non‐Isothermal Multiphase Flow in Deformable Porous Materials

Coupled thermal, hydraulic, and mechanical processes in porous materials play important roles in several energy and environmental technologies. The Darcy-Brinkman-Biot (DBB) framework has proven effective in modeling multiphase fluid flow in deformable porous solids across both pore and Darcy scales, including in systems where fractures coexist with a porous matrix. In this study, we extend the DBB framework, originally designed for isothermal conditions, to address non-isothermal problems by incorporating an energy conservation equation. The resulting solver, hybridBiotThermalInterFoam, enables simulations of coupled multiphase fluid flow, heat transfer, and solid deformation in hybrid-scale systems containing both solid-free regions and ductile porous domains. The new solver is validated through comparisons with analytical solutions and, also, against established heat transfer solvers chtMultiRegionFoam and compressibleInterFoam. Further, a series of 2D and 3D case studies, including two-phase heat transfer in solid-free, static, or deformable porous media, highlights the solver's capacity to simulate complex flow dynamics and heat transport in systems involving high mobility ratios, viscous fingering, and fracture propagation. Our results establish the feasibility of incorporating thermal effects in simulations of a wide variety of energy geotechnics and environmental applications, including enhanced hydrocarbon recovery, soil remediation, and enhanced geothermal energy systems.

04 OIL SHALES AND TAR SANDS↗

Hierarchical thermal-conductive polymer nanocomposites for thermal management

Managing heat in electrical conductors is a major challenge to meet the demands for sustainable energy use and electrical reliability, most notably power electronics and energy-critical electrical machines. Achieving such disparate functionalities, such as high temperature thermal and electrical reliability, require rational design and manufacturing of thermal conductor material and its hierarchical structures. Here we present hierarchical thermal-conductive nanocomposites, consisting of nanostructured ceramic conformal coating and aligned ultrahigh molecular weight polyethylene fiber, to tailor heat dissipation in electric conductors. The hybrid aligned thermal interface exhibits a highly desirable temperature dependent anisotropic high thermal conductivity with 0.98W m –1 K –1 and dielectric strength with 3.4. In addition, electrically insulating thermal interfaces demonstrate high-performing and reliable electrical systems under the dynamic load conditions. The surface temperature of heterogeneous ceramic-polymer encapsulated conductor is 17.8 °C lower than that of polymer-encapsulated conductor at the same electrical load. Consequently, the findings shown here hold great promises for directing heat extraction in electrical machine systems, advancing thermal management for emerging electronic applications.

36 MATERIALS SCIENCE↗

Solid-state crystallization of metal organic frameworks within mesoporous materials methods and hybrid materials thereof

A method, comprising i) contacting an aqueous solution of an organic ligand salt of the formula A X (L −X ) with a mesoporous material (MPM) to form an impregnated mesoporous salt material of the formula A X (L −X )/MPM, ii) treating the impregnated mesoporous salt material with an aqueous acidic solution to form an impregnated mesoporous acid material of the formula H X (L −X )/MPM, iii) contacting an aqueous solution of a metal precursor of the formula M +y (B)y with the impregnated mesoporous acid material to form an impregnated mesoporous metal organic framework precursor of the formula [M +y (B) y ][H x (L −x )]/MPM, and iv) at least one of 1) heating the impregnated mesoporous metal organic framework precursor in the absence of a solvent or 2) exposing the impregnated mesoporous metal organic framework precursor to a volatile vapor in the absence of a solvent such that the heating or the exposing forms a hybrid material of the formula (M +y L −x )/MPM, wherein the hybrid material comprises a nano-crystalline metal organic framework (MOF) embedded within the mesoporous material.

Minguez, Ignacio Luz↗

Thermal management of a high temperature sodium sulphur battery stack

The sodium sulfur battery is an advanced secondary battery with high potential for grid-level storage due to their high energy density, low cost of the reactants, and high open-circuit voltage. However, as the operating temperature of the battery is high (about 300 °C), effective thermal management is required to prevent thermal runaway under high current density operation. Here, to develop efficient thermal management strategies, a detailed, thermo-electrochemical, non-isothermal, distributed dynamic model of a sodium-sulfur battery stack is developed. Models of three thermal management strategies are developed and analyzed in this work: active cooling, passive cooling, and hybrid cooling. The active cooling strategy uses air as the cooling medium whereas, the passive cooling strategy uses a phase change material. In the hybrid cooling strategy, both active and passive cooling strategies are used. Due to the high operating temperature of the sodium sulfur batteries, the rejected heat can be utilized effectively and consequently a high variability in the heat rejection rate may not be acceptable. Performance of these strategies is analyzed under high current density operation by evaluating the variability in the cell temperature during charge/discharge cycles, temperature difference between the cells based on their locations, and variability in the heat rejection rate. The phase change-based hybrid thermal management strategy with an embedded controller maintained the temperature variation within ±/- 2.8 °C. Considering the tradeoff between the capital cost for PCM, fan power requirement, and variability in the heat rejection rate, the optimal quantity of the PCM and the maximum air velocity for the maximum current density of 260 mA/cm 2 (0.55 C-rate) were found be 0.74 g/Wh and 3 m/s, respectively.

25 ENERGY STORAGE↗

Technical, economic, and load-following capabilities assessment of grid-connected geothermal and geothermal-solar hybrid systems

The technical and economic performance as well as the load-following capabilities of grid-connected geothermal hybrid systems were assessed in this work. The analyzed geothermal hybrid configuration is composed of a binary geothermal plant integrated with a concentrating solar-thermal system and underground thermal energy storage (UTES) through a primary heat exchanger. Physics-based models for the hybrid system for plant generation capacities of 1, 25, and 50 MW were developed from validated models for each subsystem. Also, an economic model was developed that accounts for different hybrid system capabilities, solar field sizes, and thermal storage duration. The advantage of the geothermal hybrid system was assessed by comparing the performance with the baseline benchmark geothermal plant with a similar configuration and generation capacity. It was found that hybridizing geothermal plants with concentrating solar and thermal energy storage not only improves the thermal efficiency by up to 8 percentage points when additional heat from the solar-UTES loop rises the evaporator temperatures from 70 to 125 °C, but also enhances the load-following capability for the geothermal plant, which can meet a typical residential load profile with a power rate of change 0.25 kW/s with an absolute error under 13 kW for a 1 MW plant. Other benefits of hybridization include resource preservation and a potential LCOE reduction of up to 56% for a 50 MW geothermal hybrid plant having a 50% solar share, a 1.4 solar multiple, and 24-h storage capacity. The results presented in this work demonstrate that hybridizing geothermal systems transforms them into a flexible and cost-effective solution for addressing the dynamic requirements of modern electric grids.

15 GEOTHERMAL ENERGY↗

Decayheatml

This code is designed to predict and analyze the decay heat generated in molten salt reactors (MSRs) using a hybrid approach that combines machine learning and segmented polynomial fitting. The accurate prediction of decay heat is essential for reactor safety and the optimization of spent fuel storage. The code operates through several key components: 1) Data Architecture: It incorporates a modular data architecture that handles various MSR-specific operational parameters such as power density, humidity content, and air ingress. These parameters are sampled using Sobol sequences to ensure comprehensive coverage of operational uncertainties. 2) Machine Learning Framework: The code employs a diverse set of machine learning models, including polynomial regression, decision trees, random forests, gradient boosting, support vector regression, k-nearest neighbors, multi-layer perceptrons, and symbolic regression. These models are trained to predict decay heat over a wide temporal range, from immediate shutdown up to 10,000 years. 3) Region-Optimized Training: The temporal domain is divided into multiple regions, each modeled separately to capture distinct decay heat characteristics across different time scales. This approach significantly improves the accuracy and interpretability of predictions. 4) Segmented Polynomial Interpretation (SPI): The SPI method translates machine learning predictions into piecewise polynomial equations. These equations are physically interpretable and can be directly integrated into existing engineering workflows and safety analyses. 5) Front-End Interfaces: The code includes both a Jupyter notebook interface for research development and a Streamlit web application for operational deployment. These interfaces allow users to interactively explore decay heat predictions, adjust operational parameters, and visualize results in real-time. 6) Applications: The framework supports various applications, including safety system validation and spent fuel container optimization. It enables real-time evaluation of worst-case decay heat scenarios, informing the design of passive safety systems and optimizing container designs for long-term storage. Overall, this code provides a robust, accurate, and user-friendly tool for predicting decay heat in MSRs, enhancing reactor safety, and optimizing spent fuel management.

Retamales, Mauricio Eduardo Tano [Idaho National L↗

Lower‐Hybrid Wave Structures and Interactions With Electrons Observed in Magnetotail Reconnection Diffusion Regions

Abstract We investigate waves close to the lower‐hybrid frequency in 12 magnetotail reconnection electron diffusion region (EDR) events with guide field levels of near‐zero to 30%. In about half of the events, the wave vector has a small component along the current sheet normal, consistent with known lower‐hybrid drift wave properties, but the perpendicular magnetic field fluctuations can be comparable or greater than the parallel component, a feature unique to the waves inside and adjacent to EDRs. Another new wave property is that the wave vector has a significant component along the current sheet normal in some events and completely along the normal for one event. In 1/4 of the events, the term has a significant contribution to the wave electric field, possibly a feature of lower‐hybrid waves more likely to exist in the diffusion region than further away from the X‐line. Electron temperature variations are correlated with the wave potential, due to wave electric field acceleration and crossings at the corrugated separatrix region with different amounts of mixing between reconnection inflowing and outflowing populations. The latter also leads to the anti‐correlation between parallel and perpendicular temperature components. Using four‐spacecraft measurements, the magnetic field line twisting is demonstrated by the correlated fluctuations in and . The lower‐hybrid wave in the EDR of weak guide field reconnection may be generated near separatrices and penetrate to the mid‐plane or locally generated, and the latter possibility is beyond the prediction of previous reconnection simulations.

79 ASTRONOMY AND ASTROPHYSICS↗